Emergency lighting and accessories (Portable Emergency Lighting System Tower type with Battery Bank Emergency Lighting And Accessories (Portable Emergency Lighting System Tower Type With Battery Bank ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Portable emergency lighting system consisting Rechargeable Battery Bank
Charging unit with charging cables
Mobile (from vehicle) charging kit and cables
Tower/Telescopic collapsible mast/Vertical mast
LED Luminaire
Supporting kits
Tool Kits
Storage box for tool kits (Tool kit list to be furnih by seller at the time of supply) Yes - Type of battery Rechargeable - Chemistry of battery Lithium ion SMF Lead acid battery
Lithium ion Battery capacity (minimum) 12 Ah As per GeM Catalogue. Minimum continuous working hours 8 hours 2 hours
4 hours
8 hours
10 hours
12 1/7 hours
18 hours Minimum System Lumens 5000 As per GeM Catalogue. IP rating of LED Luminaire IP65 IP54
IP65
IP66
IP67
IP68 Ruggedised Storage Box for main equipment Yes - TOWER CONSTRUCTION Maximum of height of Tower/telescopic collapsible mast/Vertical Mast with light source (in meters from base ground level) 2 metre 1 metre
2 metre
3 metre
4 metre
5 metre
6 metre
8 metre Material of Tower/lel escopic/Vertical Mast Aluminium Aluminium
Mild steel
Galvanised Iron
Fiber
Stainless steel Minimum thickness of Tower/lelescopic collapsible mast/Vertical Mast material (+/-5%) 3 mm - Method of step up and step down of To wer/lelescopic/Vertic al Mast Winch mechanism Pnumatic
Hydraulic
Motorised
Winch mechanism Step up and step down time of Tower/lelescopi c/Vertical Mast </=2 Minutes - The strength of the Tower/telescopic collapsible mast/Vertical Mast tower is to provide support for it to remain erect at wind speed of 40 km/hr - BATTERY CONSTRUCTION Number of battery 1 - Battery voltage 12 Volt - Battery bank construction shall have inbuilt charging arrangement with charging cables Yes - System must have Battery charging arrangement with AC power source input and with DC power source input with necessary Yes - 2/7 cables Additional charging cable and kits for battery charging from automobile vehicles (Mobile charging option) Yes - Warranty card for battery 1 Year - System shall also work on 220/240V
50 Hz AC supply and for connecting to the mains shall have provision for 15 Amps 3 Pin/2 pin Socket and a suitable lead wire with plugs at both ends Yes - LED LUMINAIRE CONSTRUCTION LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes - Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes - LED Modules as per the IS: 16103(Part-2)/2012 Yes - Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt - LED chip Efficacy ≥130 Lm/Watt - Colour temperature (+/-500K) 6000K - Working life for LED (Minimum 50
000 burning hours as per LM-80 report) >/= 50
000 burning hours - Colour Rendering Index(CRI) ≥70 - Optic lense materal (UV stabilised) Poly carbonate lense - The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes - 3/7 The luminaire body must be corrosion resistant powder coated Yes - All fastners must be of stainless steel Yes - Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 latest IP67 - Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover/polycarbonate and the metal housing to exclude the entry of the dust
water
insects etc.
Yes - Luminaries light transparency should be of Toughened glass Yes - Toughned transparent glass/poly carbonate cover thickness >/=4 mm - Toughned Glass polycarbonate shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes - Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes - Operating temperature range -10 deg C to +50 deg C - "Manufactures Name and and brand on the aluminium die cast body " Engraved/Embossed - Date of manufacture (month-year)
and lot number as identification mark inside each unit and the outside of each Yes - 4/7 packaging box REPORTS AND CERTIFICATION Availability of type tet reports from Central Government Laboratory/NABL Accrediated/ILAC Laboratory for complete Portable emergency lighting system including for Engine
Alternator and Luminaires as per relevant IS specifications as applicable Yes - Luminaire System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes - Availability for LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government NABL/ILAC accrediated lab. (Reports shall be furnish on demany by buyer/Consignee) Yes - Availability of LM 80 & TM 21 (Ref. IS:16105:2012) Report and Photo biological report for LED report from Central Government NABL/ILAC accrediated lab. (LM-80 report shall have the Pohoto Biological report of the LED Chip being used in the luminaire) (Reports shall be furnish on demany by buyer Consignee) Yes - LED Luminaire shall have Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 or as applicable for portable emergency lighting Yes - 5/7 system as on date Total Weight of complete system (Must declare) in Kg </=10 Kg - Warranty for complete system 1 Year - Storage battery shall have Complusory Registration(CRS) of BIS as per IS 16270 : 2014 as applicable as on date Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Harin Bahoo Arun 413001
DRM OFFICE CENTRAL RAILWAY SOLAPUR 2 15