Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST RATE QUOTED | |
| 2 | L2₹5.6 L+₹7,938.99 (1.44%)Rejected-Finance | L2 | Rejected-Finance Highest amount quoted | |
| 3 | L3₹5.8 L+₹25,350.48 (4.60%)Rejected-Finance | L3 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
6 Jul 2022, 2:00 pmClosed
Executive_Engineer_PWD_Hooghly_Electrical_Division
HOOGHLY ELECTRICAL DIVISION
Electrical installation works at one no boys hostel, security room and providing LED display board at main entrance gate _ allied works in DIET ,Hooghly
2022_WBPWD_386513_1
WBPWD/EE/HED/NIeT-03/2022-23
Open Tender
Electrical Work/ Equipment
Item Rate
25 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
HOOGHLY ELECTRICAL DIVISION
22 Nov 2022
22 Jun 2022
8 Jul 2022
22 Jun 2022
6 Jul 2022
22 Jun 2022
27 Jun 2022
Amount
Distn. Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal and vertical run embedded in wall] to light / Fan / Call bell point as per GS with following average run.
9 Mtr [5d / E-15 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point as per GS with following average run.
On Board [ 4 (a)(i) / E- 10 ]
S & F PVC rigid conduit (Precision mk) on wall with saddles as per GS.
20 mm size [ 7(a)/ E- 16 ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.
13 mm dia 3 mm thick [ 2 (a)/ E- 2 ]
19 mm dia 3 mm thick [ 3 (a)/ E- 2 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
S & F solderless Copper socket by crimping of Copper wires.
a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
Supplying & Fixing sheet metal box (16 SWG) of the following sizes(in mm ) flushed in wall as along with 3 nos Cu bars with holes on hard rubber & 3 mm thick bakellite cover as per GS
175mm x 100mm x 65mm [10(b)/E-4,(12(c)/E4)]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS
175 x 100 x 65 [11(c)/E-4 ,E5/13(c)]
200 x 150 x 65 [11(d)/E-4 ,E5/13(d)]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+12 Way [Siemens Enclosure(8GB32102RC14)/Schneider Enclosure-(A9HSND12) or equivalent model of Legrand] as per direction of EIC. [ 13 / D- 9 & D-10 ]
2+8 Way [Siemens Enclosure(8GB32102RC10)/Schneider Enclosure-(A9HSND08) or equivalent model of Legrand] as per direction of EIC. [ 13 / D- 9 & D-10 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/KEI/Polycab]
2 Core 10 Sq. mm
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Laying of cable upto 35 sqmm in underground trench as per GS for the following numbers of Cables.
1 No Cable [ 1(a)/ F- 2 ]
Laying only Cable upto 50 sqmm through existing Pole for single, 2, 3, 3½ & 4 core [3(a)/F-1]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
2 Core 10 Sq. mm [7(c)/F4 & 8(b) /F5]
Supply & Fixing 240 V, 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [ 17b/ E-6 ]
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent make CG / Bajaj / Wipro incl. 1no. 18W Master LED Tube
Fixing only single/twin fluorescent/LED light fitting in the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS.[ 14d/C-2 ]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [16/C-2]
Supply of ceiling fans complete with all accessories without regulator. ( Make -Orient-New breeze or equivalent model of CG/Usha-Striker Plus)
a. 900 mm Sweep
Supply & fixing heavy duty Exhaust fan(Make-EPC] of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust incl. s&f louver shutter as per G.S. )
12"( 300mm ) Speed 920 RPM
S & F of MS down rod 14 SWG 20 mm dia MS conduit as per GS
Supplying & Fixing MS fan clamp of two piece type for RCC as per approved specification as per GS. [ 29/D-14 ]
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide [ 30/D-14 ]
Supply & Fixing Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board as per GS [ 18 (a) / E-6 ]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Engraving the deptt. number with 10 mm lettering on the body as per GS. [ 24 (a) / C-3 ]
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS [ 26 (a) / C-3 ]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS [ 22/D-13 ]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
50mm dia [11(d)/F-6]
S&F of 250V timer DB (equivalent to 4 way SPNDB in size) with sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 1 no 24 hr analog time switch( Mk- L & T, cat no- AUTS01ANA00) complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC.
S&F of 250V 24 hr analog time switch( Mk- L & T , cat no- AUTS01ANA00) in exsisting timer including connections as per direction of EIC
S & F of 3 pole power contactor ( Mk- L & T ,MNX 22, cat no- CS94980) in exsisting timer including connections as per direction of EIC
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.[ 18/C-3 ]
Supply & Fixing of 240V, 45W LED Street light luminarie (Crompton Geaves-Cat no.TRP-409-45-57SL-NS-GL-NSGor equivalent make of Philips/Bajaj//wipro) on GI pipe bend as per direction of E.I.C
S/F Stainless Steel water proof looping cable box of size 200x150x100mm having hinged top Cover with rubber gasket lining, railway type mechanical locking anangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same after cuuting wall and mending damages.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
Supply of LED Tube illuminated sign board fabricated by 20'(L)x2'(H)x10"(W) ACP box supported with 50 x 50 x 2.5 mm M.S. square bar all around with 40mm x40mmx 1.62 mm Al. edge angle for front portion only.The back side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 6 mm laser cut Acrylic letters out of which 5 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facia as per the direction of EIC.The sign board should be illuminated by 18W LED Tube lamps (12 nos.) (Type- MAS LED Tube lamp 18 W 2100 lm) with Tube fittings (Phillips make) to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top of prefabricated iron structure as per direction of EIC.
Making heavy scaffolding arrangement for working at a height of 15 ft. with making bamboo structure incl. hiring of bamboos with the help of 1 no. skilled fitter, 3 nos. helpers.
Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint .
One coat of red lead/Zinc chromate priming [7B( c )/H-2]
1st coat of synthetic enamel paint over the primer [7B( d )/H-2]
2nd coat of synthetic enamel paint over the 1st coat[7B( e )/H-2]
M.S. structural work in column beam etc. with simple rolled structural members(e.g. joist, angle chanel,section)
i) For stuctural members of specified sections weighing not less than 22.5 kg per meter.( Page 99, item 1( I ) of PWD schedule)
Supplying M.S. angle (50 x 50 x 5 mm) 4.5 kg/mtr.
Supply of MS base plate (8mmx450mmx450mm) (12kg x2nos. =24 Kg )
Supply of MS base plate (8mmx250mmx400mm) (7kg x2nos. =14 Kg )
Supply of MS Channel (150x75x6mm) 16.79 kg/ mtr.
Supplying M.S. flat (50 x 6 mm)1.2 kg/mtr.
Transportation Charge of above materials without Sign board from Co's workshop to worksite. ( 2.5% of total of item no.-(a-e))
Cutting and drilling holes on MS plate with grinding the plate. This plate is to be fixed with the precutting roof with 6"x0.5" size fastner.
Fabrication charge of the iron structure incl. hiring of welding machine incl. making connection as required.
Add GST @12% Rs.
Add LWC @1% except item no.-12,18,22,41 & 44:- Rs.
R.D.ELECTRICAL ENGINEERING CO
RAKSHIT CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .