CPO-SOUTH ZONE
This Tender is for carrying out works related installation of Linear lighting at retail outlets located under
2500023481-HD-07750
5100023481
Open Tender
Two Bid
Unknown (Unspecified Location)
₹0
Exempted
5 Nov 2025
15 Oct 2025
5 Nov 2025
5 Nov 2025
16 Oct 2025 - 25 Oct 2025
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | Removal of False Cei | Removal of False Cei — Removal of False ceiling at Retail outlets. thecostincludesScaffolding charges, Electricity etc ifany.Theceiling material removed should be in a position toberefixedwithout any damage. | - | square meter |
| 2 | Supply&fixing newfal | Supply&fixing newfal — Providing <(>&<)> fixing false ceiling system of Trac 150Fexterior grade or approved equivalent of 0.5mmthickgalvanised steel with stove enameled coil coatedfinishinter locking ceiling panels, carriers, suspensionsystemand edge closure as per the followingspecific ation.Supplying and installation of exterior grade150 F ceilingsystem comprising of 150 mm x 17 mm deeppanels roll formedout of 0.5 mm galvanised steel with stoveenameled coilcoated finish. The panels shall be pre-treatedand coilcoated on one side in manufacturers standard colourshadesas approved by the Architect/ Engineer in charge. Therearside of the panel shall be given a coat of primer andawash coat while the finished side shall be given a coatofprimer and finish colour coat in polyster paint for amin.dry film thickness of 20 microns, fixed on to therollformed carriers 34.5 mm x 488 mm deep out of 6 mmthickGalvanised steed with prongs to hold panels in themoduleof 150 mm at maximum 1.2 mts. C/C. The carriers tobesuspended from roof truss by rigid suspension angles aspermanufacturer's recommendation. Panels shall be suppliedincustom length upto maximum of 5 mts. Job alsoincludesproviding ceiling flashing using factory formed 0.5mmthick Polyster coated galvanised steel material. Rateshallbe including providing flashing to cover gap if anybetweenilluminated banding and false ceiling. | - | square meter |
| 3 | Refixing of Old fals | Refixing of Old fals — Refixing of the Old false ceiling in good conditions asperthe advise of Engineer Incharge | - | square meter |
| 4 | Removal of Roofing | Removal of Roofing — REMOVAL AND STACKING OF THE EXISTING CANOPY ROOFINGMATERIALAND ROOFING SYSTEM AND STACKING THE REMOVEDROOFING MATERIALMATERIAL AT UN OBJECTIONABLE PLACE AT THERETAIL OUTLET ASDIRECTED BY THE EIC AND THE CONSULTANT.THE MATERIAL REMOVEDFROM THE EXISTING CANOPY TO BE STACKPROPERLY WITH INDEXINGTHE MATERIAL GOOD FOR INSPECTION | - | square meter |
| 5 | Supply&fixing Newroo | Supply&fixing Newroo — """""""Supply and fixing Clippon Roofing System:Roofingbasematerial should be of cold rolled steel of 0.55 mmthickand conform to ASTM:A 446 having yield stress of 275MPA .The coating should be Aluminum and Zinc alloycomprising55% Al , 43.5 Zinc <(>&<)> 1.5 % Silicon , as per ASTM:A 792 .The coating mass should not be less than 150 Gmsper SqM(total of both sides). For, bare galvalume, TCTshould notbe less than 0.55 mm . Sheets shall have approvedside lapswith top sheets facing away from the prevailingweather.Necessary profiled filler box should be provided athigherlevel of roof sheeting and at valley gutter to ensurewatertightness in the profiled gaps . The fixing ofroofingshall be done in such a manner that the roof is notdrilled/ punctured for fixing with the purlins .Refer totheapproved makes given in the Attachment. Flashings,Cappingsand trims:These shall be formed out of samesubstrates asthat of the roofing sheets and shall besupplied instandard lengths of 2.5 M in the required shapesand girthsand fixed by means of hex-head mechanicallygalvanizedstitching screws. Silicon sealant non-hardeningneutralcure type shall be applied at all laps to avoidwaterseepage""""""" | - | square meter |
| 6 | Refixing of Old roof | Refixing of Old roof — CANOPY ROOFING SHEET REFIXING WITH NUT BOLTFIXTURES.Refixing of Clippon Roofing which is good incondition | - | square meter |
| 7 | Disman of Existing G | Disman of Existing G — """""""DISMANTLING AND REMOVING OF EXISTING GUTTERS. CARESHOULDBE TAKEN FOR NOT DAMAGING THE EXISTINGSHEETSAND STRUCTURE. REMOVING AND SHIFTING OF THEREMOVEDMATERIAL AS PER INSTRUCTION OF ENGINEER-IN-CHARGE""""""" | - | Ream |
| 8 | Supply & Fxng AL Gut | Supply & Fxng AL Gut — """""""Providing and fixing 2 mm thick Aluminum Sheet Guttersofrequired shape in slope with 40 mm x 3 mm MS. Bracketsat1000 mm maximum spacing and 8 mm dia G.I. J or Lhooks,boltsand nuts, GI Limpet and bitumen washers ,providing nutbolt joint , sealing the joints with siliconsealanttesting the gutter for leakage by filling wateretc.Complete.(Refer attached Drawing .For allowabletolerancerefer to IS codes""""""" | - | Ream |
| 9 | Refixing of Old Gutt | Refixing of Old Gutt — """""""REFIXING THE GUTTER WITH ABOVE INCLUDING SILICONSEALANTALL ON LAPS. MEASUREMENT : GUTTER LENGTH INRUNNING METERS""""""" | - | Ream |
| 10 | 4C X 2.5 SQMM Copper | 4C X 2.5 SQMM Copper — """""""Supply and laying following size PVC insulated,sheathed,armoured cable of approved make conforming to IS1554:Part1:1988 4CX2.5SQMM COPPER CABLE """"""" | - | Ream |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2500023481-HD-07750.pdf
TENDER_DOCUMENT • 39.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .