Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC 210 14 R B AVENUE KOL 29 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L1 | Accepted-AOC that the bid is L1 | |
| 2 | L2₹31.1 L+₹72 (<0.01%)Rejected-Finance 90 E B C ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹33.9 L+₹2.8 L (9.05%)Rejected-Finance 184 BHUPENDRA ROY ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | L4₹34.4 L+₹3.3 L (10.8%)Rejected-Finance 45 MOTILAL STREET KOLKATA 700013 | KOLKATA | KOLKATA | WEST BENGAL | 700013 | L4 | Rejected-Finance that the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
20 Sept 2021, 10:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE KNHED PW Dte
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Conversion of Ward 3 and Ward 4 of Beliaghata Campus Dr B. Roy PGIPS Kolkata for HDU including AC UPS and DG support for preparedness for next wave of COVID -19 Pandemic Electrical Installation Work
2021_WBPWD_343844_1
WBPWD/EEKNHED/Short/Q/94/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹80,000
14 Nov 2024
14 Sept 2021
22 Sept 2021
14 Sept 2021
20 Sept 2021
16 Sept 2021
120 days
Amount
SITC OF LT SUB- PANEL SITC of LT,Cubicle Type, Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker as per detail specification below. The general construction of the pannel will conform to IS 8623:93 as ammended uptodate. The Degree of IP protection for the enclosure will be IP-42.It will have multi tier arrangement, having necessary cable alley at both end, with rigid and self supporting structure fabricated with sufficient no. of channels & covered by 2mm thick CRCA sheet with base structure by 75x40x4mm channel.
All incoming, outgoing SFUs & Bus Coupler are to be housed in respective compartments with hinged and gasketted doors at the front. All the doors should have pannel lock arrangements in such a fashion that it cannot be unlocked unless the respective feeder remains OFF. The rear of the pannel should have gasketted wire net guard for ventillation and arrangement shall be made for easy access to each compatment by providing rear doors with locking system. The pannel is to be properly gasketted to prevent the dust and vermin. All vertical and horizontal bus bar chamnbers are to be properly arranged and all electrical switches, busbars are to be fixed by MS nut-bolts on suitable hylam board / non - hygroscopic insulators of adequate size and dimensions. The outgoing feeder connections from respective switches are to be made at the rear side of the pannel by means of bus-bar/multicore copper cables, to be terminated on bolted type terminals for cable connections or bush insulators for bus connection
It will be powder coated after seven tank pretreatment process.2 Nos copper strip of size as per IS shall be fixed all around the panel and will be connected to 2 nos copper earth bus bar connected to incoming earth conductor.All tests should be made for the complete panel.The following 415 / 230 Volt Open Execution Type switches with fuses & accessories will be fixed in the panel. (ALL THE INCOMING AND OUTGOING SWITCHES WILL BE OF L & T MAKE )
INCOMING a ) 4 Pole ,415V, 400 A TPN SDFU with 3 Nos 400 A DIN type HBC fuse link (Make-L&T) -1no. b ) 4 Pole ,415V, 400 A TPN Change Over Switch . (Make-L&T) -1 no. BUSBAR 1.415 V, 600 A electrolyte grade tinned copper bus bar with vertical section of size 50mm x10 mm +/-5% for phase & Nutral Bars.The Bus Bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Shrinkable sleeve of suitable size & color as per direction of EIC
OUTGOING 1. 415 V,50Hz, 160A TPN SDFU with 3 Nos 160 A DIN type HBC fuse link (Make-L&T) -- 3 Set 2. 415 V,50Hz, 125A TPN SDFU with 3 Nos 125 A DIN type HBC fuse link (Make-L&T) -- 2 Set
ACCESSORIES A. S&F 3Ph multifunction metering (KWH, KW, KVA, V,I,F,PF) Class 1 accuracy,screw terminals AC/DC wide Voltage power supply 110- 240V, AC ±10% ,50/60 Hz,110-250V DC ±10%(Make-Legrand/L&T)-3 Set 800/5A ,10VA,CL.1 CT (Kappa/AE)- 3 no. 320/5A ,10VA,CL.1 CT (Kappa/AE)- 6 no. 200/5A ,10VA,CL.1 CT (Kappa/AE)- 3 no. R-Y-B LED Indicator Lamp [Legrand/L&T] - 3 Set 6A"C" curve 10KA MCB (MK-Legrand) 6A TP MCB -4 Nos Danger Board
Inter Connection : Interconnection for power to be done by solid copper bar by colored PVC Sleeve of following sizes: i) Incoming terminal to ACB & ACB to Bus Bar by 50x10 mm All interconnection of metering panel to be done by 2.5 sq.mm multistranded copper wire finish with Copper socket by crimping method having marked ferrule for indication
Earthing- A separate earth bolt/Bars-2 Nos will be provided in panel board in both sides as per drawing. Cable alley: Cable entry arrangement will be provided in both side of the cubical panel in vertical possition with appropriate size FRP insulator to support outgoing copper bars indicating phae & Neutral for each outgoing main switches & gland plate must be placed at the bottom of the panel with detechable type as per direction of E.I.C
Painting:The Complete panel board shall be painted by two coats of powder coated paint over two coats of RO primer of approved make and brand and color as per direction of EIC.
Supplying and delivery of 1.1 KV grade armoured Alminium XLPE cable on wall as per G.S. (Make: Gloster/Havells/Nicco) 4 core 240 sqmm(Incomeing cable)
4 core 50 sqmm(Light and Power DB VTPN)
Laying of cable on existing cable tray incl. earthing attachment in 2 x10 SWG GI (Hot DIP) wire, making holes etc. as necy., mending good damages 4 core 240 sqmm
4 core 50 sqmm
Supply and fixing compression type glandcomplete with brass gland brass ring and rubber ring for dust and moisture proof entry of XLPE/PVC armoured cable. 240 sqmm 4core
50 sqmm 4core
Finishing the end of following XLPE/PVC armoured cables bycrimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials 240 sqmm 4core
50 sqmm 4core
Supplying and fixing double door 8 way Vertical TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(as per Make: Legrand/L&T AU/ABB/ Siemens ) INCOMING- Supplying and fixing 415 V, 160A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in DBs and necessary connection -1No.(Make:Legrand) OUTGOING- Supplying and fixing 240V 63A TP MCB of Breaking capacity 10kA & C characteristics on 1din rail of existing DBs and necessary connection-8 nos.(Make: Legrand)
Supplying and fixing 415V 6/10A, 8 way TPN MCBDB (Legrand/L&T make) comprising with of 1no. 63A FP Isolator and 24 nos.,(6- 32)A SP MCB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Supplying and fixing 230V 6/10A, 2+4 way SPN MCBDB (Make: Legrand) comprising of 1no. 20A DP Isolator & 4nos. 6/10A SPMCB double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Supplying and fixing 230V 6/10A, 2+10 way SPN MCBDB (Make: Legrand) comprising of 1no. 40A DP Isolator & 10nos. 6/10A SPMCB double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling ] Avg Run 10 Mtr
Do-----Do------ 5A on board point.
Distn. Wiring in 1.1 Kv gr. Single core stranded ‘FR’ PVC insulated & unsheathed cu. wire (Havells / KEI / Finolex) in 20/32/40 mm size PVC rigid conduit ‘FR (precession) incl. necy. Fitting as reqd. a) 2 x1.5 sqmm + 1x 1.5sqmm for ECC
b) 2 x2.5 sqmm + 1x 1.5sqmm for ECC
c) 2 x 4 sqmm + 1 x 2.5 sqmm for ECC
d) 2 x 6 sqmm + 1 x 4sqmm for ECC
e) 4 x16 sqmm + 2 x 10 sqmm for ECC
Finishing end of copper wire and PVC/Al cable of the fol;owing sizes by crimping method as per GS 16 sqmm
S & F of Single LED Tube light fitting [Make - Philips cat no. TMC 501 P 1 x T-LED / Crompton cat no. IGP161 LT8-16 / Wipro, cat no.WIO921208] complete with 18/20 Watt LED tube lamp [Make - Philips Master LED tube model no.18W 865 T8 I 2100lm / Crompton cat no. LTT8-20 / Wipro cat no.- LL13-181-65SE ] suspended below the ceiling with S&F 2x20mm dia EI conduit up to 25 cm long with 'L' type MS clamp and making connection as to GS.
S & F of Twin LED Tube light fitting [Make - Philips cat no. TMC 501 P 2x T-LED / Crompton cat no. IGP162 LT8-16 / Wipro, cat no.WIO922208 / complete with 2x18/20 Watt LED tube lamps [Make - Philips Master LED tube model no.18W 865 T8 I 2100lm / Crompton cat no. LTT8-20 / Wipro cat no.- LL13-181-65SE ] suspended below the ceiling with S&F 2x20mm dia EI conduit up to 25 cm long with 'L' type MS clamp and making connection as to GS
S&F of 230V 18 watt LED Slim surface panel circular type corresponding fixing in top of the cercular box .(make-Philips cat no- DN9413B LED 15S 6500PSUWHS1 /CG cat no- Cool daylight LCDSPLN-R-18-CDL )
Extra for suspension exceeding 25cm with s & f additional 2 no. 20mm dia conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as reqd. by 2 x 24/ 0.20 mm (1.5 sqmm) flexible copper wire of 1.10mt. length
S&F 240V, 100W rotary step type electronic fan regulator on board with making necy. Connection .(make Anchor)
S & F MS fan clam of two piece type for RC celling as per approved speceification ,fabrication from 40 mm x 9 mm MS Fflat including making good damages to building roof with satisfactory finishing and painting - (As per Drawing no. 475 of PWD Specification Book-May 1991)
S& Fixing 240V 50 Hz 56" sweep (1400 mm) ceiling fan complete with down rod,Canopy,fork etc.(Make- CG-HS plus 5star ) and Fixing the ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by3x1.5 sqmm single core stranded pvc insulated unsheathed copper wire .
Supply & Fixing 1420 rpm 240V AC Heavy duty 12’’ Exhaust Fan including cutting hole & mending good damages .(Make : EPC/CG)
Supply & Fixing 230V 50Hz 400mm sweep heavy duty full metal body /Decorative type wall bracket fan with all accessories on wall with necy. bolts & nuts. ( make- CG/EPC/Cinni)
S & Fixing of extra suspension 3/4 inch 14 SWG M.S Fan downrod ( avg length 3 fit)
S & F 240V,25A,3 pin plug socket 2 module (Legrand,Myrius cat no-673145/Crabtree) without switch & with plug top on 2 Module switch board with top cover plate fixed in wall including s&f switch board and cover plate and making necy. connections with PVC Cu wire and earthing continuity wire etc. [for AC point)
S & F 240V, 4 nos. 16A Plug socket ( Anchor,white) & 2 nos. 6A plug socket ( Anchor,white) with separate 4 nos. 16A Piano key type switch( Anchor,white) & 4 nos. 6A Piano key type switch (Anchor,white),240V LED indicator( colour- RED, make -L&T, cat no-EPLR240A) & 16A switch type SP MCB (legrand / havells) on sheet metal switch board embedded in wall incl. S & F 450 mm x 200 mm x 65 mm MS (16SWG ) Switch board and bakelite top cover ( white) of 3 mm thick by brass screws after making housing for switch by cutting bakelite cover and making necy connection for CU. wire as required.
S & F 240V, 4 nos. 16A Plug socket ( Anchor,black) & 4 nos. 6A plug socket ( Anchor,black) with separate 4 nos. 16A Piano key type switch( Anchor,black) & 4 nos. 6A Piano key type switch (Anchor,black),240V LED indicator( colour- Green, make -L&T, cat no-EPLR240A) & 16A switch type SP MCB (legrand / havells) on sheet metal switch board embedded in wall incl. S & F 450 mm x 200 mm x 65 mm MS (16SWG ) Switch board and bakelite top cover ( Blue) of 3 mm thick by brass screws after making housing for switch by cutting bakelite cover and making necy connection for CU. wire as required.( For UPS board)
S & F 240V, 16 A piano key type switch ( make- Anchor ) on sheet metal switch board (100 mm x 100 mm x 65 mm ) with bakelite top cover by screws after making housing and making necy. Connection for GYSER
S & F 240V, 16 A piano key type Socket( make- Anchor ) on sheet metal switch board (100 mm x 100 mm x 65 mm ) with bakelite top cover by screws after making housing and making necy. Connection for GYSER
S&F multi plug board of size 240 x 200 x 65 mm M.S. Box comprising with 2 No. 250 V 6 pin 20A plug socket with 2 No. 20A piano key type switch, 2 nos. 250V 6A 5 Pin plug socket with 2 nos. 6A Piano Key type switch 1 No. Indicator & (6-16) A fuse (Anchor /Vinay Make) and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
S&F 240V,25A single phase starter 2 module(legrand, Myrius cat no-673031) with 25A switch type DP MCB (C-curve) (legrand/ Crabtree/ North West) with 4 module modular GI box & 4 module frame(legrand Myrius-689009&673224) cover and making necy. Connections with CU wire and earth continuity wire etc.(Make-Legrand/crabtree).
Supply of Single-Phase timer for controlling 1 No. single-ph AC M/C(concealed split) of size 1.5/2 Tr. Consisting of the following: a) 8 way SPN DB-1 No.-Double Door(Make:L&T/ Simence), b) Astronomical Timer, 0-999hrs (Make: L&T), c) DP MCB 250V/32A-1No.(Make: L&T), d) 3-pole power contactor of required rating-1No.(Make: L&T) , e) DB Locking arrangement must be there f) Push Bottom ON/OFF switch individual outer side of DB (There must be bypass mechanism and indication for ON/OFF by indicating Lamp of the AC m/c unit attached to it.)(For Single Air Conditioner Machine )
Supply of 3 ph timer for controlling 1 no. 3-ph A.C. MC(consealed split) of size 5/7.5 Tr. Consisting of the following a) 16 inch. X 12 inch x 6 inch. -double door MS Box b) Astronomical Timer , -999 hrs. (make-Siemens/L&T ) , Cat No. 7PV07321AV20) , C) 4P MCB 415V/63A-1 NO.(make-Siemens/L&T) , Cat no. 5TL44327RC , d) 4P Isolator 1no.(make-Siemens/L&T) , Cat no. 5TL13320 , e) 4 pole power cotactor of required rating -2 no. (make-Siemens/L&T) , Cat no. MNX701597076 type , f) DB locking arrangement must be there , g) 6A MCB , h) Push bottom ON/OFF switch indivisual outer side of DB (There must be bypass mechanism and indication for ON/OFF by indicating lamp of the AC m/c unit attached to it )(For double Air-Conditioner Machine )
S&F 415V, 400A TPN SFU with open Execution (Make : L&T, ) incl. S&F 3 nos. DIN type 400A HRC fuse with SS Enclosure for incoming & outgoing cable fixed at both as per direction of EIC Fixed on wall
S&F 415V, 100 A TPN On load front operated change over with SS enclosure (Make : L&T, Cat. No. CO106300SOO) on angle iron frame on wall fixed for heavy type GI Z clamp with fastner incl. S&F 3 nos. DIN type HRC fuse with S&F special type 2 nos. SS Cable end box (16 SWG) of suitable size for incoming & outgoing cable fixed at both end of SFU with nut, bolt & washer etc. incl. powder coated painting as per direction of EIC
S & F of 240/415 V, 100 A 4pole MCB on din rail of existing DBs & necessary connection ( make- Legrand, Cat no-40652
S & F 220 V 32A SP MCB ( Legrand, C - Curve), 32A, 2P+E (Make: L&T,cat no DBMPS332SD) Industrial plug & socket including 32A industrial top ( make- L&T, cat no- MPS332P) on conceal wall at negative presure motor with necy. Connection as per GS
S & F PVC Gland 32 mm
S & F of 415V, 100 A 4Pole battery terminal/stud with nut,bolt & washer etc. as per direction of EIC.
Supplying & fixing double door SPN MCB Distribution board with IP-42/43 protection , concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter comnnection with sutiable size of copper wire and neutral link & provision for earthing attachment 2+8 way Enclosure (607711) make- Legrand / L&T
S&F (10" x 8 " ) MS Board (Loop Box) with single door system deep 5 inch. With 1 no. channel for 4 pole MCB insulation on wall including necessary interconnection complete
Supply and fixing 240/415 V MCB of breaking capacity 10 KA & C charectyeristics on din rail of existing DBs and necessary connection (make-Legrand) as per GS a) 63A , Four Pole
Supply & instaallation 30 KVA (input 3PH /OutPut 3 Ph) Full Load PF: 09 true on line -Double Conversion IGBT Based Modular UPS System With External isolation Transformer & 30 Mins SMF Battery Back-up ,Power Cabinet With 3 nos of 10 KVA Module to be equiped with ambient temperature
Input Voltage :-380-415 V ,O/P Voltage -380-415 V .Input Frequency :-50 Hz +/-0.1%in free runing & +/-4% in Sync , Wave Form :-Sinusoidal. Minimum Backup at Rated Load - 30 Min ,Over Load :110% for 10 Min, 125% for 4 Minute .
Rippel:less than 2% ;Inverefficiency :>93% ,Battery 12 V Total VAH 25000 (or As Suitabel minimum 30 min Battery Back at rated Load) SMF Battery (VRLA) - Make-Exide/Amar Raja(Quanta) with minimum 2 years warranty;
Input/Output Terminal Conection :3P + N + PE Connection . Protection:-Input/Output over Vboltage ,under voltage,singel phase protection ,DC High under/over voltage ,Battery Charging Over Current ,Output Over load/Short Circuit Oveer temp.
Ups autoon on Mains recovery ,Audio alarm mains fail , Battery Low,pre Alarm Inverter trip ; METERING:-LCD Display for input/Output -Voltage, Frequeency ,Current,battery Voltage & Current
Switch gear :-MCB/MCCB for input ,Battery ,Output Manual Bypass Switch ; Noise Level :<75 Db at 1 mtr distance ;Protection Degree:-IP 21;Cooling -Forced Air ; Standard Warranty :-2 years on site repair or replacement.
Standard Warranty :- 2 years on site repair or replacement,Start up service ,Make-Numeric/AVO/APC/Emmersion
Supply & Fixing of perforated GI cable tray with perforation not more then 17.5% suspended from ceilling incl. S&F GI connector 6mm dia MS suspender, bolts & nuts, steel fastener etc. As required of the following size incl. Al painting of MS support. with 25x25x3 mm angle iron support- 300x50x25mm (18SWG)
Dismaintaling the all old tubelight fittings & all the old electrical equipments of Ward and all material goes to section store as per EIC.
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties) (Defect Libilities Period 01 year from the date of completetation)
SIMPSON AND FERRIS PVT LTD
MODERN ELECTRIC
M/S N. C. HORE
technical_658329.pdf
PDF • 0.27 MB
techsummary_658329.pdf
PDF • 0.27 MB
finance_658329.pdf
PDF • 0.27 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_658329.pdf
PDF • 0.28 MB
AOC.pdf
PDF • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .