Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹23.2 L+₹52,035 (2.30%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹27.9 L+₹5.2 L (23.1%)Rejected-Finance | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹34.2 L+₹11.6 L (51.1%)Rejected-Finance 7 2 S F ARIHANT ARCADE CENTRAL MARKET SHASTRI NAGAR MEERUT U P 250004 | MEERUT | MEERUT | UTTAR PRADESH | 250004 | L4 | Rejected-Finance In order but L4 |
Tender Value
Refer Docs
EMD Value
₹65,200
Closing Date
10 Nov 2022, 6:00 pmClosed
GE(U) E/M Meerut Cantt
Roorkee road Meerut Cantt
TENDER FOR ITEM RATE CONTRACT FOR CLEANING OF OHT AND UG SUMPS USING MODERN TECHNIQUES AND COMPOUNDS INCLUDING REPAIR/MAINT OF DAMAGED INTERNAL WIRING OF PUMP HOUSES IN SOUTH AREA UNDER AGE E/M WS AT GE (U) MEERUT CANTT.
2022_MES_548421_2
8434/E8
Open Tender
Civil Works - Water Works
Works
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE(U) E/M Meerut
₹65,200
Yes
15 Dec 2022
20 Oct 2022
12 Nov 2022
20 Oct 2022
10 Nov 2022
27 Oct 2022
Amount
M&L multiple stage cleaning and sterilization inside the existing RCC overhead tank of capacity 25000 gallon through bacteriological treatment by using TERBAC G10, TERBAC G5, TERBAC 065/E-in-C's Branch approved chemical as recommended by Engr-in-Charge and ULTRA VOILET RAY at Pump house at any height (as per site requirement), including suitable steging/scalfolding multi stage of clening are as under follows:- (a) First stage is to drain out the water by using high capacity pump of dewatering system. (b) Second stage is cleaning all the stage formation inside the tank by using TERBAC G10 a laboratory tested branded chemical/ E-in-C's Branch approved chemical as recommeded by Engr-in-Charge. (c) Third stage is scrubbing the walls and floor with mechanised scrubber and fresh water cleaning high speed jet pump (Rotary & flat) to remove all scalling algae and other formed particles on internal surfaces of the tank completely. (d) Fourth stage and first bactria screening is slatrilisation by using TERBAC G5, Laboratory certified branded helogen compuond E-in-C's Branch approved chemical as recommended by Engr -in-Charge,
Test certificate from government laboratory monitoring suitability for starlization should be submitted to the office before using stralisation. (e) Fifth stage is cleaning the floolr of water tank by heavy duty industrial vaccume cleaners and sludge succor having maximum 1200 watt with suitable heavy duty rugged motor to free any foreign and loose particales of any nature duty UV radiation which shall have 360 degree sterilization within the tank to kill all suspended bacteria (The radiation shall be portable and effective for sterilization of drinking water tanks for dimention of floating and suspended bacteria.) (f) Sixth stage is the second bacterial screening is slatrilisation by using Ultra voilet ray ejector covering 360 degree with in the tank and kills all suspended bacteria (g) Seventh stage of cleaning and third bacteria screening is to sterlizes the floor, roof and wall of the water tank by using laboratory certified branded strong oxidizing agernt TERBAC 65 of M/S Ray's clean tech or equivalanet any non toxic bio-degredable eco-friendly anti-bacterial agent
certified by a Govt. approved laboratory to disinfect the over head tank from all harmful pathogens. (h) Cleaning of external and internal surfaces, lid wall of the tank, structure free from all scales and other particles any algae, hives and any type of vegetation of any other unwanted matters, scrapping of old paint and painting with two coats of cement based water proof apex paint complete all as directed. (j) A Board of appropriate size and colour as directed by Engr-in-Charge and of non degradeable material with printed details as under :- (k) (i) CA No (ii) Name of applicant (iii) Name of the contractor (iv) Columns for date of cleaning and expiry date will be written or printed on the sticker by permanent marking ink. (l) Testing of water sample of OHT each before as well as after cleaning which is to be include the following tests : bacterial, biological , chemical , hardness test, through a NABL certified laboratory.
Note : (i) All required safety equipemnts (Gumboot, helmets, safety belts, safety foogles, torch light etc) and necessary insurance for safety of working staff to execute the work is responsibility of the contractor. (i) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that is deemed to be inclusive in the unit rate and electricity/diesel shall not be provided by the MES. (iii) Contractor will not be allowed more than one day to do the work inside of the each OH tank /UG sump to prevent interruption of water supply to the users.
All as per item No 1 above but the capacity of the tank is 50000 gallon
All as per item No 1 above but the capacity of the tank is 100000 gallon
All as per item No 1 above but the capacity of the tank is 200000 gallon
Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets light fitting etc removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per condition seprately) and making good disturbed surfaced of wall , floors etc complete all as specified and as directed by Engr-in-Charge.
Taking down carefully sub-main wiring of any type/description including battens/ casing caping on surface and making good to the disturbed surface to match the existing, complete all as specified and as directed by Engr-in-Charge.
M&L Point wiring surface type with 1.5 sqmm (nominal area) PVC insulated stranded single core unsheathed FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 1.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLS copper cable as earth continuity wire connecting to common earth point with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulatros etc complete) for One light point or one fan point or exhaust fan controlled by one switch complete all as specified and as directed
-ditto- but for one 3 pin socket outlet, 6 Amp on the same board with other switches
-ditto- but for one 3 pin socket outlet, 6 Amp on the independent board with other switches
M&L Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLS copper cable as earth continuity wire connecting to common earth point (with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting socket combination for 5 pin, 16 Amp on independent board complete all as specified and as directed.
M&L Sub main wiring with 4.0 sqmm (Nominal area) FRLS with two runs of single core PVC insulated stranded unsheathed copper conductor cable upto and including 1100 V grade drawn through PVC casing capingfixed to wall/ ceilling etc incl one runs 4.0 sqmm (nominal area) single core, FRLS PVC insulated stranded unsheathed copper conductor as earth wire and duly connected to common earth point etc. complete all as specifed and as directed. Note: Two runs of 4 sqmm single core cable, one run of 4.0 sqmm earth continuity wire and one run of PVC casing caping shall be measured as one length.
M&L Sub main wiring with 2.5 sqmm (Nominal area) FRLS with two runs of single core FRLS PVC insulated stranded unsheathed copper conductor cable upto and including 1100 V grade drawn through PVC casing capingfixed to wall/ ceilling etc incl one runs 2.5 sqmm (nominal area) single core, FRLS PVC insulated stranded unsheathed copper conductor as earth wire and duly connected to common earth point etc. complete all as specifed and as directed. Note: Two runs of 2.5 sqmm single core cable, one run of 2.5 sqmm earth continuity wire and one run of PVC casing caping shall be measured as one length.
S&F surface and wall mounted LED batten, 1 X 20 Watt in extruded aluminium housing, with polycarbonate diffuser & integrated electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper conductor cable of suitable size incl taking down existing fitting complete all as specified and directed. (MAKE: HAVELLS, Model: Endure Linear Neo / HALONIX, Cat No: HLB-03-20CW-AL / SURYA, Cat No: SLE BTN T8 20W or equivalent model in BAJAJ / JAQUAR / PHILIPS)
S&F stepped type fan regulator for ceiling fan of sweep 1200/1400 mm stepped type 230 volts, 100 watt flush mounted complete all as specified and as directed.
M&L Ceiling rose, surface type polycarbonate/bakelite, 65 x 50 mm three terminals, conforming to IS, complete all as specified and as directed
S&F Switch piano, flush type 5 amps, 240 volts, single pole, one way, conforming to IS complete all as specified and as directed.
S&F Socket outlet 2 in 1, 5 pin 5 Amps flush type conforming to IS complete all as specified and as directed.
S&F Switch piano, flush type 15 amps, 240 volts, single pole, one way, conforming to IS complete all as specified and as directed.
S&F Socket outlet 2 in 1, 6 pin, 15 Amp flush type 240 volts, single pole, one way, conforming to IS complete all as specified and as directed.
S&F in repairs SPN DB, IP 43 protection, double door, 240 volts, 4 way including taking down existing DB complete all as specified and directed. (MAKE : LEGRAND, Cat No. 507610/ L&T, Cat No. DBSPN004DD / ABB, Cat No. NSYN8690SPN0M04 / SCHNEIDER, Cat No. NBKRENSNDD04 or equivalent model in INDO ASIAN / HAGER / C&S / HAVELLS) (NOTE : DB & MCB shall be of same manufacturer)
Supply and fixing inrepair LED street light fitting 70Watt230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete.all as specified and directed
Taking out old unserviceable post top lantern of any type and supply and fixing of post top lantern Clear/Milky defuser, spun cover, Die cast, IP 65, Module with LED. The lantern to include 25 watt LED light/bulb fitting(Warm/White) complete all as specified and directed by Engr-in-Charge Note: The rate quoted are deemed to include cost of fittings,bolts, nur, brackets CA required & all other labour/accessories
Supply and fixing 06 Sqmm flat twin core, 1100 Volts grade, heavy duty, Aluminium stranded conductor cable served with PVC inner sheathing and overall PVC insulated for service connections complete all as specified and directed.
M/S KRISHNA KAVYANSH BROTHERS
AARYANS GLOBAL INDIA
AEGIS INTERNATIONAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .