Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC | ₹41.9 L Quoted ₹44.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹45.3 L+₹36,600 (0.81%)Rejected-Finance | ₹45.3 L+₹36,600 (0.81%) | L2 | Rejected-Finance Being not lowest tenderer |
| 3 | L3₹45.9 L+₹92,300 (2.05%)Rejected-Finance 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | ₹45.9 L+₹92,300 (2.05%) | L3 | Rejected-Finance Being not lowest tenderer |
| 4 | L4₹47.4 L+₹2.4 L (5.39%)Rejected-Finance | ₹47.4 L+₹2.4 L (5.39%) | L4 | Rejected-Finance Being not lowest tenderer |
| 5 | L5₹51.0 L+₹6.1 L (13.5%)Rejected-Finance | ₹51.0 L+₹6.1 L (13.5%) | L5 | Rejected-Finance Being not lowest tenderer |
| Sl No | Description | Qty | Unit | Neeraj Enterprises L3 | M/S Delhi Engineering Co. L1 | M/S S.K.Electricals L2 | M/s Prakash Enterprises L4 | akenterprises L5 | M/S HARINDER SINGH L6 | SRA Engineering L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for Maintenance of earthing including measurement of Earth resistance and earth to neutral voltage of earthing any type (Chemical/Conventional & Grid earthing) pertaining to various locations with proper calibration earth tester and recording the reading in a register and take appropriate action such as pouring of salt mixed water in earth pit, replacement of blocked rusted funnel, tightening the earth strip through nut, bolts and washers, replacing old rusted worn out nuts and bolts with new complete all as specified and directed. | 5,000 | Jobs | 99 ₹4,95,000 | 90 ₹4,50,000 | 91 ₹4,55,000 | 25 ₹1,25,000 Lowest | 80 ₹4,00,000 | 39 ₹1,95,000 | 80 ₹4,00,000 |
| 2.00Note : (i) The Contractor or his rep will attend the office of AGE E/M (AF) TKD daily for collection of complaint slip at 0900 hrs. (ii) The Contractor must provide manpower (one skilled and one unskilled) to carry out earth pit resistance check of each section of entire area every month and will enter the value of each earth pit and obtain signature of user rep as well as JE E/M (iii) Total one earthing check will be counted as one job (iv) The earth resistance checking equipment including all necessary T&P items shall be provided by the contractor and the cost of the same to be included in the quoted rate. (iv) The cost of material such as funnel, common salt, charcoal dust, magnesium sulphate (MgSO4) etc will be paid under relevant item of this schedule as supply only however the cost of nut bolts shall deemed to be included in the quoted rate. | ||||||||||
| 3.00 | M&L for cleaning all unwanted vegetation from surrounding of earth pit, within the radius of 1 Mtr apart, cleaning inner side and out side of earthing pit complete all as directed. | 800 | Each Job | 10 ₹8,000 | 20 ₹16,000 | 21 ₹16,800 | 45 ₹36,000 | 8 ₹6,400 Lowest | 39 ₹31,200 | 8 ₹6,400 Lowest |
| 4.00 | Supply and fix in replacement Precast (Factory Manufactured) Earthing pit of size 450 mm x 450 mm x 450 mm x 50 mm thickness with Mortar design precast Pit cover, made with RCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1 reinforced XPM of weight not less than 4 Kg/Sqm and plaster work inner or outer etc including taking down old pit cover, excavation complete all as specified.
Make - OM Precast/ Dagar Tiles/ AC Construction/ Venus/ Any other Precast RCC manufacturer | 300 | Each Job | 350 ₹1,05,000 | 500 ₹1,50,000 | 400 ₹1,20,000 | 300 ₹90,000 Lowest | 350 ₹1,05,000 | 499 ₹1,49,700 | 350 ₹1,05,000 |
| 5.00 | Supply only common salt for earthing pit complete all as specified and directed. | 4,200 | Kg | 10 ₹42,000 | 4 ₹16,800 Lowest | 5 ₹21,000 | 10 ₹42,000 | 8 ₹33,600 | 19 ₹79,800 | 8 ₹33,600 |
| 6.00 | Supply only Charcoal dust for earthing pit complete all as specified and directed. | 140 | Kg | 10 ₹1,400 | 100 ₹14,000 | 90 ₹12,600 | 15 ₹2,100 | 8 ₹1,120 Lowest | 19 ₹2,660 | 8 ₹1,120 Lowest |
| 7.00 | Supply only Magnesium Sulphate (MgSo4) for earthing pit complete all as specified and directed. | 1,600 | Kg | 125 ₹2,00,000 | 70 ₹1,12,000 | 65 ₹1,04,000 | 50 ₹80,000 | 125 ₹2,00,000 | 49 ₹78,400 Lowest | 125 ₹2,00,000 |
| 8.00 | Supply and fix earthing indicator made out of Aluminium sheet of size 30 cm x 25 cm, 3mm thickness with support of flat iron frame of size 25 x 4 mm including necessary Earth work, PCC work over and including ine coat of synthetic enamel paint complete all as directed. | 110 | Each | 100 ₹11,000 | 150 ₹16,500 | 100 ₹11,000 | 450 ₹49,500 | 80 ₹8,800 Lowest | 199 ₹21,890 | 80 ₹8,800 Lowest |
| 9.00 | M&L in repair of old existing PCC earthing pit making connection of earth strip including minor adjustment, construction of rectangular/square any size brick boundary along with necessary plastering work with specified colour coding around poly plastic earth pit cover, complete all as specified and directed by Engineer-in-Charge. | 190 | Each Job | 410 ₹77,900 | 500 ₹95,000 | 450 ₹85,500 | 250 ₹47,500 Lowest | 400 ₹76,000 | 299 ₹56,810 | 400 ₹76,000 |
| 10.00 | M&L for one coat painting of old existing earthing pit in existing colour complete all as specified and directed by Engr in charge | 330 | Each Job | 180 ₹59,400 | 100 ₹33,000 Lowest | 150 ₹49,500 | 190 ₹62,700 | 200 ₹66,000 | 149 ₹49,170 | 200 ₹66,000 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
8 Jul 2025, 6:00 pmClosed
GE AF Tughlakabad
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/MAINT OF HIGH MAST LIGHT AND EARTHING INFRASTRUCTURE AND MISC CONNECTED WORKS OF OLD U/S EARTHING LA SYSTEM, EARTHING STRIP, EARTH PIT AND PREVENTIVE MAINT OF E/M INSTALLATIONS INCL PNEUMATIC PRESSURE PIPELINE AT VSB AND TECH AREA, BRD AF TKD
2025_MES_714971_1
GE/TKD-45/2025-26
Open Tender
Civil Works - Others
Item Rate
270 days
GE AF Tughlakabad
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹0
₹84,000
Yes
3 Dec 2025
17 Jun 2025
10 Jul 2025
18 Jun 2025
8 Jul 2025
2 Jul 2025
Amount
Material and labour for Maintenance of earthing including measurement of Earth resistance and earth to neutral voltage of earthing any type (Chemical/Conventional & Grid earthing) pertaining to various locations with proper calibration earth tester and recording the reading in a register and take appropriate action such as pouring of salt mixed water in earth pit, replacement of blocked rusted funnel, tightening the earth strip through nut, bolts and washers, replacing old rusted worn out nuts and bolts with new complete all as specified and directed.
Note : (i) The Contractor or his rep will attend the office of AGE E/M (AF) TKD daily for collection of complaint slip at 0900 hrs. (ii) The Contractor must provide manpower (one skilled and one unskilled) to carry out earth pit resistance check of each section of entire area every month and will enter the value of each earth pit and obtain signature of user rep as well as JE E/M (iii) Total one earthing check will be counted as one job (iv) The earth resistance checking equipment including all necessary T&P items shall be provided by the contractor and the cost of the same to be included in the quoted rate. (iv) The cost of material such as funnel, common salt, charcoal dust, magnesium sulphate (MgSO4) etc will be paid under relevant item of this schedule as supply only however the cost of nut bolts shall deemed to be included in the quoted rate.
M&L for cleaning all unwanted vegetation from surrounding of earth pit, within the radius of 1 Mtr apart, cleaning inner side and out side of earthing pit complete all as directed.
Supply and fix in replacement Precast (Factory Manufactured) Earthing pit of size 450 mm x 450 mm x 450 mm x 50 mm thickness with Mortar design precast Pit cover, made with RCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1 reinforced XPM of weight not less than 4 Kg/Sqm and plaster work inner or outer etc including taking down old pit cover, excavation complete all as specified. Make - OM Precast/ Dagar Tiles/ AC Construction/ Venus/ Any other Precast RCC manufacturer
Supply only common salt for earthing pit complete all as specified and directed.
Supply only Charcoal dust for earthing pit complete all as specified and directed.
Supply only Magnesium Sulphate (MgSo4) for earthing pit complete all as specified and directed.
Supply and fix earthing indicator made out of Aluminium sheet of size 30 cm x 25 cm, 3mm thickness with support of flat iron frame of size 25 x 4 mm including necessary Earth work, PCC work over and including ine coat of synthetic enamel paint complete all as directed.
M&L in repair of old existing PCC earthing pit making connection of earth strip including minor adjustment, construction of rectangular/square any size brick boundary along with necessary plastering work with specified colour coding around poly plastic earth pit cover, complete all as specified and directed by Engineer-in-Charge.
M&L for one coat painting of old existing earthing pit in existing colour complete all as specified and directed by Engr in charge
M&L in replacement for GI brazing (welding) at site to connect loop GI earthing strip of any size after tighten by nut, bolt , washer , checknuts all as specified and as directed by Engr-in-charge. Note : GI brazing should be done any height. Cost of necessary tool/plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rate quoted
M&L in replacement for copper brazing (welding) at site to connect loop copper earthing strip of any size after tighten by nut, bolt, washer, checknuts of brass, complete all as specified and as directed by Engr-in-charge. Note : Copper brazing should be done any height. rate of necessary tool/plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rate quoted.
Supply, Installation, Testing & Commissioning in replacement of Ring Earth Pit which includes the Installation of following : (a) Digging /Auguring /Boring of Five Single Earth Pits of minimum 125 mm dia to the depth of approx. 2.8 meter. (b) Insertion of 17.2 mm x 3000mm Earth Electrode of low carbon steel with molecularly bonding of electrolytic grade copper coating (purity 99.9%) having min. 250 microns thickness shall comply with Specification IEE 80- 2013 & IS 3043-2018 and penetrating it at least 0.2 meter by pushing gently with sledge hammer where the natural soil is assumed for all five pits. (c) Filling of Earth pit with Earth Enhancement Compound (ITPC-EECP15) in slurry form and backfilling. (d) Job of Exothermic Welding Material for bonding the earth system shall be as per RDSO specs, which includes graphite moulds, clamps weld metal powders. (e) Carrying out exothermic weld connection job on the single earth electrode to a copper tape of 150 x 25 x 6 mm.
(f) Carrying out exothermic weld connection job on the copper tape of 150 x 25 x 6 mm of on master Earth Electrode for connecting two 35 Sqmm cables for redundancy. (g) MEEB of size 300 x 25 x 6 mm is to be fixed inside the equipment room with two insulation studs. (h) 300 x 300 x 300 mm (inside dimension) Precast (factory manufactured) RCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate in (Mortar design) 80 mm thick (yellow painted) with steel reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape etc including Mild steel Earth marker with earthing result ,date all as per per AIR HQ Policy No Air HQ/37529/9/1/ERA/W(P&C) dated 21 Nov 16 (j) Except the master earth pit all the remaining earth pits are to be buried in the ground. (k)Digging of trench to min depth of 0.5 m and laying 20 x 3 mm bare copper tape connecting all the five Earth Pits. (l) Routing and laying 20 x 3mm copper tape connecting all the five Earth Pits. (m) Carrying out exothermic weld connections job on all the five Earth Electrodes to Copper tape of size 20 x 3 mm for interconnection of earth pits. (n) It shall be ensured that the distance between any two earth electrodes shall be minimum 3 m and max. Upto twice the length of the Earth Electrode to avoid mutual resistance effects. Make: Kratonite/ITPC-chem/Ashlok/Sofamel/Inpocon/Maltep
Supply only carbon based low resistivity compound .001 ohm meter, backfill compound for maintenance free earthing compound to achieve desired resistance value less than 1 ohms, complete all as specified and directed by Engineer-in-Charge. Make of backfill compound : Curenite or equivalent
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal dust (100 kg) and common salt (300 kg) ,vegetable soil (300 kg), including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe upto 7.5 mtr and watering pipe 20 mm dia light grade with funnel and wire mess including necessary earth work i.e Excavation and removing upto 500 mtr distance , Precast (factory manufactured) RCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC with Precast RCC pit cover (Mortar design) 80 mm thick (yellow painted) with steel reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape etc including Mild steel Earth marker with earthing result ,date all as per plate no.3 of SSR 2009 Page No 497 and AIR HQ Policy No Air HQ/37529/9/1/ERA/W(P&C) dated 21 Nov 16 with dismantling old earthing, complete all as directed and specified. Note : The earth value/result must be less than 5 ohms.
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal dust (100 kg) and common salt (300 kg) ,vegetable soil (300 kg) including GI strip 25 x 4mm as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe upto 7.5 mtr and watering pipe 20 mm dia medium grade with funnel and wire mesh including necessary earth work i.e Excavation and removing upto 500 mtr distance, Precast (factory manufactured) RCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC with Precast RCC pit cover (Mortar design) 80 mm thick (yellow painted) with steel reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape etc including Mild steel Earth marker with earthing result ,date all as per plate no.3 of SSR 2009 Page No 497 and AIR HQ Policy No Air HQ/37529/9/1/ERA/W(P&C) dated 21 Nov 16 with dismantling old earthing, complete all as directed and specified. Note : The earth value/result must be less than 5 ohms.
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal dust (100 kg) and common salt (300 kg),vegetable soil (300 kg) including GI strip 32 x 6mm as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe upto 7.5 mtr and watering pipe 20 mm dia light grade with funnel and wire mesh including necessary earth work i.e excavation and removing upto 500 mtr distance , Precast (factory manufactured) RCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC with Precast RCC pit cover (Mortar design) 80 mm thick (yellow painted) with steel reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape etc including Mild steel Earth marker with earthing result ,date all as per plate no. 3 of SSR 2009 Page No 497 and AIR HQ Policy No Air HQ/37529/9/1/ERA/W(P&C) dated 21 Nov 16 with dismantling old earthing, complete all as directed and specified. Note : The earth value/result must be less than 5 ohms.
Material and labour for Earthing complete with 99.9 % pure copper earth plate electrode 900 x 600 x 5 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal dust (150 kg) and common salt (400 kg),vegetable soil (400 kg), including Copper strip 20 x 3 as earth lead fixed by means of brazing etc and other end connected to the test point including 40 mm dia light grade GI protection pipe upto 7.5 mtr and watering pipe 20 mm dia light grade with funnel and wire mess including necessary earth work i.e Excavation and removing upto 500 mtr distance, Precast (factory manufactured) RCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC with Precast RCC pit cover (Mortar design) 80 mm thick (yellow painted) with steel reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape etc including Mild steel Earth marker with earthing result ,date all as per plate no.3 of SSR 2009 Page No 497 and AIR HQ Policy No Air HQ/37529/9/1/ERA/W(P&C) dated 21 Nov 16 with dismantling old earthing, complete all as directed and specified. Note : The earth value/result must be less than 5 ohms.
Supply and fix in replacement of Air termination, single pointed aluminium rod 12 mm dia and 300 mm long as per site requirement with saddle complete all as directed.
Supply and fixing of copper strip size 20 x 3 mm as earth continuity conductor or main earthing lead fixed to wall on insulator or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed. Note :- Porcelain/suitable insulators with nut, bolts, screws for fixing strip at the span of one meter and for fixing the strip on high rise bldgs not more than 20 Mtrs to be included in the quoted rate, copper earth strip will be connected by brazing only to another any portion of copper strip .
S&F in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 03 Nos 8 mm dia 25 mm long hexagonal bronze head screw complete all as directed.
S&F in replacement of Aluminium strip of size 25 x 3 mm as earth continuity conductor or main earthing lead to wall on insulator or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as directed. Note :- Porcelain/suitable insulators with nut, bolts, screws for fixing strip at the span of one meter and for fixing the strip on high rise bldgs not more than 20 Mtrs to be included in the quoted rate, Aluminium strip should be connected with another portion of strip at the time of fixing by aluminium riveting only.
Supply and fixing in replacement of unserviceable LT Feeder Pillar Box out door type 1.1 KV made out of MS CRCA sheet of size 3.15 mm thick with CRCA sheet powder coated, having 4 Nos Aluminium bus bar of size 200 Amps for phase ( 40 mm x 5 mm ) and 100 Amps ( 20 mm x 5 mm ) for neutral fixed on LT 8 Nos insulators of size 0.60 M x 0.45 M X 0.45 M with 04 legs made out of MS angle 50 X 50 X 5 mm & 0.75 Mtr in length with locking arrangements with SS aldrop each side, front and back opening , danger board, gland suitable for 150 sqmm cable 4 core -02 Nos and including FPB foundation with suitable PCC work and Excavation and incoming and out going connections and testing on completion, complete all as specified and directed.
S&F DMC insulators for earth strip of any size with 02 Nos nut bolts for fixing of copper/aluminium/GI strip, one Nos screws for fixing insulators on wall or roof etc complete all as specified and directed. Note- Earthing strip cross sectional area should not be reduced anywhere at the time of fixing.
Supply and fixing LED Strip rope light, 50 meter length not exceeding number of lamps 120 per meter with max wattage 6.5 / mtr, IP 65 rating for outdoor use warm light inclusive light fitting and driver, 230V, to be flexible design and customizable as per requirement complete all as specified.
Supply and fixing of online change over switch 630 Amps, four pole, 415 Volts, 50 Hz, Standard: IS: 13947 IEC 60947-3, including stainless steel enclosure and fixing with fasteners/screws on wall including disconnecting of old Changeover switch with cables and reconnecting the cables in new changeover switch complete all as specified.
Supply and fixing in replacement energy saving LED Flood light/high bay light of 150 Watt Capacity high pressure die cast aluminium housing with seal toughned glass cover, light source should be multi LED SMD system efficacy should be minimum 100 lumen/watt cool/warm as per site requirement ,voltage range 120 -220 Volts IP -66 driver should be potted / CE certified/R certificate and Driver efficiency 85% including making connection complete all as specified and as directed.
Supply and fixing in replacement energy saving LED Flood light/high bay light of 100 Watt Capacity high pressure die cast aluminium housing with seal toughned glass cover, light source should be multi LED SMD system efficacy should be minimum 100 lumen/watt cool/warm as per site requirement ,voltage range 120 -220 Volts IP -66, driver should be potted / CE certified/R certificate and Driver efficiency 85% including making connection complete all as specified and as directed.
Supply and fixing in replacement energy saving LED Flood light/high bay light of 80 Watt Capacity high pressure die cast aluminium housing with seal toughned glass cover, light source should be multi LED SMD system efficacy should be minimum 100 lumen/watt cool/warm as per site requirement ,voltage range 120 -220 Volts IP -66, driver should be potted / CE certified/R certificate and Driver efficiency 85% including making connection complete all as specified and as directed.
M/S S.K.Electricals (BID ID -3349296)
Neeraj Enterprises (BID ID -3344012)
M/s Prakash Enterprises (BID ID -3349896)
akenterprises (BID ID -3350682)
M/S HARINDER SINGH (BID ID -3351634)
SRA Engineering (BID ID -3351739)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .