| 1 | L1₹13.6 LAccepted-AOC NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L1 | Accepted-AOC FULL FILL THE CONDOITION OF CA | |
| 2 | L2₹15.1 L+₹94,209 (6.63%)Rejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L2 | Rejected-Finance Rejected being not the lowest | |
| 3 | L3₹16.9 L+₹2.7 L (19.3%)Rejected-Finance PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L3 | Rejected-Finance Rejected being not the lowest | |
| 4 | L4₹17.6 L+₹3.4 L (23.8%)Rejected-Finance D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | L4 | Rejected-Finance Rejected being not the lowest |
Tender Value
₹17.8 L
EMD Value
₹35,580
Closing Date
10 Jul 2020, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
Special repair/replacement of BER cooling appliances at air crew room and ships galley and Special repairs to street/security lights at ICGAS Chennai under GE (I) (CG) Chennai
2020_MES_345977_2
8761/GE(I)(CG)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹35,580
Yes
23 Nov 2020
16 Jun 2020
15 Jul 2020
16 Jun 2020
10 Jul 2020
23 Jun 2020
Amount
Disconnecting electric supply from electric sources, taking down split air conditioner up to 2TR capacity with voltage stabilizers without damaging any other equipments and making good and macthing with existing surface complete and including transportation to MES store yard at Fort Saint George with all accessories.Inventory of the ACs/Stabilizers to be prepared and submitted to Engineer-in-charge before disconnecting the same complete all as specified and as directed.
All as per item No 1here in before but Deep freezer 425 litres capacity
All as per item No 1here in before but Refrigerator 180 litres capacity
Supply and Install Hi wall split Air Conditioner units Indoor, outdoor (Copper Condenser coil, Copper cooling coil and evaporator including copper tubing and copper cables for connecting indoor and outdoor units) complete cardless remote control unit and with in-built ioniser and plasma filter for better indoor air quality with BEE 3 Star rating of capacity 1.50 TR ,year of manufacturing 2020 ,filled with Refrigerant gas -410 complete all as specified and as directed. Make: CARRIER/ O GENERAL/ HITACHI Note : The rate quoted by the tenderer shall inclusive of the following provisions :- (i) UPVC drain pipe with insulation not less than 20 mm dia from indoor unit (any floor) to upto ground level/ near to drain to be fixed with proper size base plate with clamps complete. (ii) Copper pipe 20mm dia and 15 mm dia with 20SWG thickness refrigerant Piping with 19 mm thick Closed Cell rubber nitrile, Class "O"- arm-flex insulation and including connection complete up to 3 metre included in this item and beyond 3.00 mtr will be measured & paid separately under respective items. (iii) GI powder coated brackets 16 SWG of required size:02 Nos including grouting with suitable size fastners . (iv) After completion of installation of ACs, the MES No and SM stickers are to be pasted over the indoor and outdoor units of AC as per direction of Engr-in-Charge.
Supply and Install Hi wall split Air Conditioner units Indoor, outdoor (Copper Condenser coil, Copper cooling coil and evaporator including copper tubing and copper cables for connecting indoor and outdoor units) complete cardless remote control unit and with in-built ioniser and plasma filter for better indoor air quality with BEE 3 Star rating of capacity 2.0 TR ,year of manufacturing 2020 ,filled with Refrigerant gas -410 complete all as specified and as directed. Make: CARRIER/ O GENERAL/ HITACHI Note : The rate quoted by the tenderer shall inclusive of the following provisions :- (i) UPVC drain pipe with insulation not less than 20 mm dia from indoor unit (any floor) to upto ground level/ near to drain to be fixed with proper size base plate with clamps complete. (ii) Copper pipe 20mm dia and 15 mm dia with 20SWG thickness refrigerant Piping with 19 mm thick Closed Cell rubber nitrile, Class "O"- arm-flex insulation and including connection complete up to 3 metre included in this item and beyond 3.00 mtr will be measured & paid separately under respective items . (iii) GI powder coated brackets 16 SWG of required size:02 Nos including grouting with suitable size fastners (iv) After completion of installation of ACs, the MES No and SM stickers are to be pasted over the indoor and outdoor units of AC as per direction of Engr-in-Charge.
Supply and fix Copper pipe 20mm dia 20SWG thickness with refrigerant Piping with 19 mm thick Closed Cell rubber nitrile, Class "O"- arm-flex insulation and including connection complete all as specified and as directed.
Supply and fixing of Copper pipe 15mm dia 20SWG thickness with refrigerant Piping with 19 mm thick Closed Cell rubber nitrile, Class "O"- arm-flex insulation and including connection complete all as specified and as directed..
Supply and fix Single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps,240 V complete all as specified and as directed. Make : Indo Asian/L&T/Siemen
Material and labour for Wiring for Circuit / Submain Wiring of FRLS cable size 2 x 6.0 sq.mm along with earth wire of size 1 x 6.0 sq.mm, Single Core, PVC insulated copper conductor (Fire Retardant) Cable in surface/recessed drawn through and including non metallic rigid PVC Conduit of size 25 mm dia complete all as specified and as directed. Note: (i)The rate quoted by the tenderer shall include for cutting chasing and making good existing surfaces (ii) Three runs of 6 Sqmm and one run of PVC conduit shall measured as one unit. (iii) Make of PVC cable:Finolex/Polycab/KEI (iv) Make of PVC Conduit :Avon plast/Garware/Kon seal
Supply and fix 4 star rating refrigerator,electric driven of capacity upto 195 litres or next higher capacity ,single door Direct cool system complete all as specified and as directed. Make:LG/WHIRLPOOL/SAMSUNG/VOLTAS/GODREJ Note:After completion of installation of refrigerator, the MES No and SM No stickers/handwriting with paint as per direction of Engr-in-Charge.
Supply and fix deep freezer hard top of capacity 425 litres or next higher capacity single phase having double door chest freezer with following specification : (i) Robust construction for heavy duty use (ii) Enhanced power saving (iii) High density puff insulation for better holding time. (iv) Heavy duty castor wheels at bottom of freezer complete all as specified and as directed. Make:VOLTAS/GODREJ/BLUE STAR Note:After completion of installation of deep freezer, the MES No and SM No stickers/handwriting with paint as per direction of Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying of UG cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exeeding 25 cm in soil complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 metre and depositing at a level not exc 1.5 metre above the starting point complete all as specified and directed.
Material and labour for M sand filling under and over UG cable including punning and levelling complete all as specified and as directed.
Supply, lay in trenches common burnt fly ash Bricks of size 230 mmx115 mmx75 mm for cable protection complete all as specified and as directed.
Supply and lay in trenches 40 mm dia galvanised iron pipe medium grade including all fittings such as bends belows tee, unions, sockets etc complete all as specified and as directed. Make- TATA/Jindal/Zenith with ISI marked.
Supply and lay cable XLPE Insulated armoured,heavy duty electric cable 1100 Volts grade with aluminium conductor of size 2 core 10 Sqmm conforming to IS specifications complete all as specified and as directed . Make:POLYCAB/CCI/ASIAN/UNIVERSAL Note: Excavation, earth work and cable protection shall be measured and paid separately.
Supply and lay cable XLPE Insulated armoured,heavy duty electric cable 1100 Volts grade with aluminium conductor of size 2 core 16 Sqmm conforming to IS specifications complete all as specified and as directed . Make:POLYCAB/CCI/ASIAN/UNIVERSAL Note: Excavation, earth work and cable protection shall be measured and paid separately.
Supply and lay cable XLPE Insulated armoured,heavy duty electric cable 1100 Volts grade with aluminium conductor of size 4 core 16 Sqmm conforming to IS specifications complete all as specified and as directed . Make:POLY CAB/CCI/ASIAN/UNIVERSAL Note: Excavation, earth work and cable protection shall be measured and paid separately.
Disconnecting , taking out from trenches / pole out lived LT UG cable of any size and taken as credit complete all as specified and as directed. Note : Excavation and earth work will be measured and paid separately.
Supply and fix70 watts or nearest next watt LED Street light fitting new generation and envirnomental friendly long life made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover having top opening separate driver compartment with IP 66 protection ad impact resistance of KO7 and with 10kv built in surge protection device complete including dismantling of old unserviceable fitting complete all as specified and as directed.Make : Philips/crompton/Wipro
Supply and fix 35 watts or nearest next watt LED Post top lantern light fitting new generation energy saving and envirnomental friendly long life asethetically designed with symmetric light distribution spun aluminium landscape luminarie with high power LEDs as light sources including dismantling of old unserviceable fitting complete all as specified and as directed.Make : Philips/crompton/Wipro
Supply and fix 30 watts or nearest next wattLED flood light fitting new generation energy saving and envirnomental friendly long life exclusive innovative die cast aluminium with high power LEDs as light sources suitable for highlighting architectural features of area lighting and also suitable for rough services installations including dismantling of old unserviceable fitting complete all as specified and as directed.Make : Philips/crompton/Wipro
Supply and fix 100 watts or nearest next watt LED Street light fitting new generation and envirnomental friendly long life made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover having top opening separate driver compartment with IP 66 protection ad impact resistance of KO7 and with 10kv built in surge protection device complete including dismantling of old unserviceable fitting complete all as specified and as directed.Make : Philips/crompton/Wipro
Material and labour for special chemical Earthing (bentonite) with copper earth plate electrode of size 900 mm x 600 mm x 5.0mm thick buried directly in ground ( earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to copper earth strip of 32mm x 6.0mm by means of bolts, nuts, check nuts and washers of copper/brass and other connected to earthing test point/equipments as directed including GI/MS sheet wire mesh funnel with watering pipe of 20mm bore light grade galvanised iron and 40mm dia GI pipe medium grade for earth lead protection chemical solution in alternative layers of 15cm compacted thickness all around the earth electrode concrete earth pit in PCC of grade M-10 using 20mm grade aggregate cast iron frame 50mm thick precast cover slab rinforced with 8mm dia deformed bar 15mm c/c and suitable handle of 10mm dia round bar including necessary excavation and erath work in soft/loose soil and disposal of soil to a distance n.exc 50m and necessary testing complete all as shown applicable and as per Electric Plate No 5 of SSR Part II complete all as specified and as directed.
Material and labour for Copper earth strip 32x6 mm Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in to conduit / pipe or fixed to poles or any other location for loop earthing complete all as specified and as directed
Taking down street light / post top lantern / security light fitting luminaires from pole/Building/gate of any type / capacity and repair the fittings by removing unserviceable parts and replacing with new parts as mentioned below to make the fitting operational and fixing back in original position complete all as specfied and as directed.
Supply and fix Pole mounting PVC Junction box (looping box) for street light ,3 phase 4 wire system with internal size 230 mmx170mmx105 mm comprising of PVC connector and one no MCB SP 6 Amps including mounting arrangement complete all as specified and as directed.Make:Sintex code no: GSIB-2014/Hensel.
Note: (i)Working hours shall be from 0900 hrs to 1700 Hrs. (ii) The repair/replacement of cooling appliances shall be carried out by qualified mechanics only. (iii Orginial GST paid PV's/TC for the materials procured for the above BOQ items shall be produced alongwith the payment claimed by the contractor.
RAVI ENTERPRISE
Banyan Engineers and Contractors
lakshmibuilders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .