Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹69.2 L
EMD Value
₹1.4 L
Closing Date
3 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
PROJECT
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N OR 'V' Whichever is less; where. V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information , along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria:As per clause no. 10.1 of GCC April 2022(a) The tenderer must have successfully completed or substantially completed any one of thefollowing categories of work(s) during last 07 (seven) years, ending last day of month previous to theone in which tender is invited:(i) Three similar works each costing not less than the amount equal to 30% of advertisedvalue of the tender, or(ii) Two similar works each costing not less than the amount equal to 40% of advertisedvalue of the tender, or(iii) One similar work costing not less than the amount equal to 60% of advertised value ofthe tender.The Similar nature of work are as below.Supply, installation, commissioning & Testing of Fire Detection & Alarm System OR Fire Detection & Alarm and Suppression System OR Any Indoor or combined Indoor & outdoor signal or Telecom or S&T work wlhich include supply, installation, testing and commissioning of Fire Detection & Alarm System OR Fire Detection & Alarm and Suppression System.
4 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tender document, Scope of work & GCC 2014 are attached with the tender.
Supply & installation of Seamless CCOE Cylinder for gas based fire suppression system as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 for the Distributed Electronic Interlocking (Centrlised EI+ 3OC cabins) at BSL Passenger Yard.
BSL-SNT-PROJ-04-2026-27~CR
BSL-SNT-PROJ-04-2026-27
Open
Works - General
4 Months
Unknown (Unspecified Location)
₹0
₹1.4 L
12 Oct 2026
12 Oct 2026
20 Oct 2026
70 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 69,17,076.49 | ||
| — | 5.00 | — | — | ||
| Supply of 120 Ltrs. Seamless CCOE Cylinder for gasbased fire suppression system asper RDSOspecification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest. (Inspection by RDSO) | — | — | — | 2,53,037.67 | |
| — | 3.00 | — | — | ||
| Supply of 80 Ltrs.Seamless CCOE Cylinder for gasbased fire suppression system asper RDSOspecification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest. (Inspection by RDSO) | — | — | — | 1,09,873.66 | |
| — | 723.00 | — | — | ||
| Cummlative Supply of Clean agent gas ( FK-5-1-12) filled in item no 1&2 as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO) | — | — | — | 9,41,495.25 | |
| — | 4.00 | — | — | ||
| Centralized Master Cylinder Kit ( 50 Bar ) Assembly consisting of : 1. Pr.Gauge + Low Pr. Supervisory Switch- 1 Nos. 2.Electromagnetic Actuator - 1 No, 3.Mannual cum Pneumatic Actuator - 1 No.,4.Flexible Discharge Hose - 1 No, (Inspection by RDSO) | — | — | — | 81,387.9 | |
| — | 4.00 | — | — | ||
| Centralized Slave Cylinder Kit ( 50 Bar ) Assembly consisting of: 1. Pr.Gauge + Low Pr. Supervisory Switch- 1 Nos. 2.Flexible Actuation Hose - 1 Nos, (Inspection by RDSO) Set1 61,902.50 | — | — | — | 59,684.46 | |
| — | 8.00 | — | — | ||
| Supply of Bleed Valve as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO) | — | — | — | 22,316.63 | |
| — | 4.00 | — | — | ||
| "Supply of Check Valve as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)" | — | — | — | 48,832.74 | |
| — | 10.00 | — | — | ||
| Supply of Nozzles as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO) | — | — | — | 36,624.53 | |
| — | 16.00 | — | — | ||
| Supply of Wall mount Cylinder bracket as RDSO/SPN/218/2016 Ver 1.0-d2 orlatest (Inspection by Consignee) | — | — | — | 7,596.23 | |
| — | — | — | RDSOspecification | ||
| — | 8.00 | — | — | ||
| — | — | — | 59,684.44 | ||
| — | Supply | of Discharge Pressure Ver 1.0- d2 orlatest (Inspection | — | ||
| — | — | — | RDSOspecification | ||
| — | 4.00 | — | — | ||
| Supply of Gas Release Panel as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO) | — | — | — | 27,129.29 | |
| — | 4.00 | — | — | ||
| "Supply of Warning Sign board as per RDSOspecificationNo.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by Consignee) " | — | — | — | 8,138.8 | |
| — | 8.00 | — | — | ||
| "Manual Release Switch as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0- d2 or latest (Inspection by RDSO)" | — | — | — | 19,688.34 | |
| — | 8.00 | — | — | ||
| Abort Switch as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspectionby RDSO) | — | — | — | 19,688.34 | |
| — | 4.00 | — | — | ||
| Sounder cum Strobe as per RDSO specificationNo.RDSO/SPN/217/2018 Ver 2 or latest (Inspection by RDSO) | — | — | — | 8,138.8 | |
| — | 8.00 | — | — | ||
| Lock-Off Valve as per RDSO specification No.RDSO/SPN/ 218/ 2016 Ver 1.0-d2 or latest(Inspection by RDSO) | — | — | — | 24,619.09 | |
| — | 26.00 | — | — | ||
| Motion Sensor as per RDSO specificationNo.RDSO/SPN/ 218/2016 Ver 1.0-d2 or latest(Inspection by RDSO) | — | — | — | 1,16,987.93 | |
| — | 8.00 | — | — | ||
| Addressable Monitor Module as per RDSO Spec.No.RDSO/SPN/217/2018 Ver. 2.0 or latest. (Inspectionby RDSO) | — | — | — | 13,532.08 | |
| — | 12.00 | — | — | ||
| Addressable Relay Module as per RDSOSpec.No.RDSO/SPN/217/20 1 8 Ver . 2 . 0 or latest.(Inspection by RDSO) | — | — | — | 20,298.12 | |
| — | 3000.00 | — | — | ||
| 2 Core cable 1 . 5 Sq mm Armored/Unarmored FireSurvival ( circuit Integrity) Cable as per RDSOS pec.No.RDSO/SPN/217/2018 Ver.2.0 or latest.(Inspection by RDSO) | — | — | — | 1,58,711.49 | |
| — | 4.00 | — | — | ||
| "Supply of C.S.Pipes forged Fittings, Manifold & CylinderStand with testing asper RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest(Inspection by RDSO) " | — | — | — | 1,62,775.81 | |
| — | 8.00 | — | — | ||
| UL/Vds flow calculation (INSPECTION AGENCY CONSIGNEE) | — | — | — | 61,184.23 | |
| — | 48.00 | — | — | ||
| Supply of In-cabinet Automatic Fire SuppressionSystem ( ICAFSS) system as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 o r latest DirectLow Pressure (DLP-Maximum operating pressure 13.5bar @ 21 deg) Clean agent ( NOVEC-1230) 2 Kg System, supplied complete with differential pressurevalve, clean agent, Pressure Gauge, Pressure switch formonitoring system pressure, end plug with panelmounting bracket (inspection by RDSO) | — | — | — | 37,80,721.89 | |
| — | 240.00 | — | — | ||
| "Supply of Linear Pneumatic Heat detection tube kit,(Standard) for In- cabinet Automatic Fire SuppressionSystem (ICAFSS) system as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)" | — | — | — | 1,13,943.41 | |
| — | 4.00 | — | — | ||
| Supply of Master Control Unit ( In-cabinet monitoringpanel(ICMP) for Incabinet Automatic Fire SuppressionSystem (ICAFSS) system as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO) | — | — | — | 46,131.75 | |
| — | 4.00 | — | — | ||
| Installation, testing and commissioning of Pipes,Fittings, Manifold & Cylinder Stand Total FloodingAutomatic Fire Suppression system (TFAFSS) (INSPECTION AGENCY CONSIGNEE) | — | — | — | 92,239.63 | |
| — | 4.00 | — | — | ||
| Integrity test for Automatic Fire Suppression System (TO BE INSPECTED CONSIGNEE) | — | — | — | 1,62,775.81 | |
| — | 48.00 | — | — | ||
| "Installation, Testing and Commissioning of In- CabinetAutomatic FireSuppression System (INSPECTION AGENCY CONSIGNEE)" | — | — | — | 1,30,220.67 | |
| — | 4.00 | — | — | ||
| Supply of Motorized Fire Damper with relayarrangement for tripping of Exhaust fan (INSPECTION AGENCY CONSIGNEE) | — | — | — | 89,426.66 | |
| — | 4.00 | — | — | ||
| Installation of Motorized Fire Damper with relayarrangement for tripping of Exhaust fan (INSPECTION AGENCY CONSIGNEE) | — | — | — | 16,069.8 | |
| — | 4.00 | — | — | ||
| Supply of Self contained breathing apparatus & FireProtective dress as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (INSPECTION AGENCY CONSIGNEE) | — | — | — | 1,95,164.16 | |
| — | 4.00 | — | — | ||
| "Installation of Self contained breathing apparatus &Fire Protective dress as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest " | — | — | — | 5,334.74 | |
| — | 4.00 | — | — | ||
| SITC of Tripping arrangement for Shutdown of AirConditioners during Fire condition (INSPECTION AGENCY CONSIGNEE) | — | — | — | 23,622.14 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC April 2022
ATTACHMENT
GCCcorrectionslip_compressed.pdf GCC correction Slip
ATTACHMENT
GCC_April-2022_2022__POLICY_27_04_22.pdf
ATTACHMENT
GCCcorrectionslip_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .