| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹25.6 L+₹2.3 L (10.0%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | L2 | Rejected-Finance High Rates | |
| 3 | L3₹26.8 L+₹3.5 L (15.1%)Rejected-Finance | L3 | Rejected-Finance High Rates | |
| 4 | L4₹27.3 L+₹4.0 L (17.1%)Rejected-AOC | L4 | Rejected-AOC High Rates | |
| 5 | L5₹27.5 L+₹4.2 L (18.1%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | L5 | Rejected-Finance High Rates |
Tender Value
₹26.6 L
EMD Value
₹53,200
Closing Date
8 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (MCTE) MHOW
GE (MCTE) MHOW 453441 MP
ADDN/ALTN OF PATHWAY IN AIR FD COMPLEX AT MCTE MHOW AND PROVN OF STORE ROOM AT FCTS AND IT WG UNDER GE (MCTE) MHOW
2021_MES_436090_1
GE(MCTE)/MHOW/01(T) OF 2021-22
Open Tender
Civil Works
Works
180 days
GE (MCTE) MHOW
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
Yes
GE (MCTE) MHOW
₹53,200
Yes
24 May 2021
13 Apr 2021
10 May 2021
13 Apr 2021
8 May 2021
26 Apr 2021
60 days
Amount
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out hard/dense soil.
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth; for foundation etc. and getting out in hard/ dense soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point
M&L PCC 1:4:8 type D-2 ( 40mm graded stone off ) in foundation , filling and mass concrete .
M&L for mild steel TMT bars 10mm dia and over cut to lengh bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or or securing clips all speicfied and directed.
All as per item 6 above but 6mm to 8mm dia bars
Ditto, but 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M & L Treating the bottom and sides of excavation at the rate of 5 ltrs of emulsion per Square metre of surface area with ATT.
M & L Treating the back fill in contract with foundation @ 7.5 ltr of emulsion per Sqm of vertical surface area with ATT.(Area of the sub struction in contact with backfill to be measured)
M & L Treating the top surface of the filled earth @ 5.00 ltr of emulsion per Sqm of surface area with ATT.
M & L Treating the soil under the plinth protection at the rate of 5 ltrs of emulsion per Square metre of surface area with ATT.
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams ; and similar work; vertical or to batter
Use & Waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for fair finished Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc. 20cm wide.
M&L RCC (nominal mix) Type B11:2:4 (20 mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M&L RCC (nominal mix) Type B11:2:4 (20 mm graded aggregate) as in Columns, pillars, piers, posts and struts
M&L RCC (nominal mix) Type B11:2:4 (20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L RCC (nominal mix) Type B11:2:4 (20 mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span.
Use and wasre of Formwork to chullah hoods, chajjas, troughs and similar items including edges .
M&L RCC (nominal mix) Type B11:2:4 (20 mm graded aggregate) as in chajjas
M&L Brickwork with fly ash bricks,straight or curved on plan exc 6 m mean radius built in CM 1:4 all as specified and directed.
M&L for 15mm thick rendering in two layers 10mm thick in CM 1:6 and 5mm thick in CM 1:4 with WPC on fair faces of brick or concrete surfaces finished even and smooth Note: WPC measured and paid separately
M&L for 15mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and smooth all as specifid and directed.
M&L for 10mm thick rendering in ceiling ,CM 1:3 on fair faces of brick or concrete surfaces finished even and smooth on soffits of slab
M&L for preparation of new plastered surfaces of ceiling and applying three coat white wash.
M & L preparation of walls newly plastered surfaces & applying two coats of cement based paint over a coat of cement primer.
M &L for preparation of newly plastered surface and applying two coats of distemper oil emulsion over a coat of primer and applying 3 mm thick wall care putty for smooth finished of the surface on wall complete all as specified and directed.
M/L for providing hard core of broken sand stone /boulders n.exc 63mm gauge, deposited spread and levelled in layers n.exc 15cm thick watered and rammed to true surface.
M&L for 75mm thick PCC 1:3:6 type C1 (20mm graded aggregate) as in plinth protection
M&L 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate).
M&L Machine pressed precast conctete interlocking paver block , coloured glosy finisehed any shape and size confirming to IS 15658-2006 of 60 mm thickness , M-35 Grade over and including 50mm thick stone dust, incl side locking with PCC 1:2:4 type B1 all as specified and directed.
M&L Cement concrete 1:2:4, type B1 (20mm graded stone aggregate) for 40mm thick floor surface finished even and smooth with out using extra cement complete.
S&F Pressed steel frames for doors size 125x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified
S&F Factory made 35mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass/wire mesh, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats
S&F 35 mm thick second class hard wood rail and style plain framed factory made panelled shutter (two panel) with lock rail and panel of 12 mm BWP commerical ply . The size of rail and stile as per IS : 1003 (part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm fixed with stainless steel wire staples/beeds.
M&L Providing, cement concrete type B-0 1:2:4 (12.5mm graded stone aggregate for filling of Pressed steel frame etc, rounded or chamfered on edges complete as specified, supplied and fixed
S & F Aluminimum anolised barrel tower bolt of extroded section 150mm long , complete all as specified and directed
S & F Aluminum handle cast type anodized size 150 mm long, complete all as specified and directed.
S&F 300mm aluminium alloy, anodized, sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy
S&F in repair door spring with 300mm mild steel rat rail rod pattern of standard quality including roller and roller plate complete Helical spring)
M & L for preparation of newly surfaces of wood over 10 cm width or girth and applying two coats synthetic enamel paint over a coat of primer complete all as specified and directed.
Preparation of New Steel surface and applying two coats of synthetic enamel paint over a coat of red oxide over 10 cm width or girth.
M&L for 10mm thick rendering in CM 1:3 on fair faces of brick or concrete surfaces finished even and smooth on roof of slab with WPC.
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for Non approachable roofs-
(a) Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster.
(b) One layer of APP based polymeric water proofing membrane of weight not less than 3 kg/Sqm consisting 3mm thick reinforced with polyster non wove fabric shall be unrolled surfaces with lap of 100 mm and the over lap shall be sealed by flame.
(c) Applying two coats of aluminum paint on top of membrane @ 0.10Kg/Sqm.
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering.
Providing and fixing of double rebate openable/fixed windows made of galvanized steel colour coated/powder coated (base steel as per IS 513 of “D" quality, galvanized as per IS 277 with zinc of 120 grams/sqm) with total thickness of coating 0.58 microns, primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, outer frame section 72 x 55 mm, centre mullion section 72 x 50 mm, shutter section 47 x 20 mm,fly mesh section 40 x 20 mm and the fixed glass beading section 12 x 12 mm, outer frame and mullions shall consists rebate for glazed shutter, fly mesh and 20 mm provision for guard bars/grills, the sections cut to length mitre joined with corner bracket,
centre mullions fixed with mullion cap, stay, handles, latch, 2 Nos of heavy duty stainless steel pivot hinges per shutter and panelled with 5mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade), fitted using EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing windows in the concrete/masonry wall by means of self-expanding screws, including 10mm Square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. complete as per the direction of Engineer in Charge.Make NCL Window
M&L Non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15 mm thick screed bed in CM 1:6
M&L Non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm inin wall/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 Complete all as specified
M/L for brick work with kiln burnt bricks built in cm (1:6) using sub class 'B' bricks of compressive strength not less than 35 Kg/Sqcm straight or curved on plan exceeding 6 mtr mean radius with old size bricks all shown on drawing and as specified.
M & L preparation of walls newly plastered surfaces & applying three coats of white wash.
M & L 50 mm thick PCC type B-2 1:2:4 ( 40mm graded stone aggt) in top layer of floor to be finished even and smooth with using extra cement.
Supply and lay XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts grade of size 35 sq mm 4 core, cross sectional area lay trenches/wall/poles/ducts/pipes or through sleeve etc including connecting/jointing with lugs and testing all as specified and directed by Engineer-in-Charge.
Supply and install ON LOAD change over switch 415V in sheet metal enclosures 4 pole of current rating 160 Amps, incl all connections complete all as specified and as directed.
Supply and Fix in repairs flush mounting factory made Vertical FP DB, IP-42 Protection -IK 09 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for 100-125 amps MCCB as incomer and SP/TP MCBs as out going 4 way complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 pole, 415 volts, in the panel and connection with using aluminum lugs complete all as specified and directed for 125 Amps rating, 16 KA breaking capacity.
Supply laying and jointing GI pipe 'light grade' 40 mm bore in trenches/under floors or roads/ along poles/ on wall incl clamps for protection of cables incl fittings complete all as specified and directed.
M & L for clean and dry sand (un washed) in trenches incl spreading and levelling for cushioning of UG cable complete all specified and directed.
M & L for brick size sub class ‘B’ (straight or curved on plan exceeding 6 mtr min radious build in cement mortar 1:6), laid flat in trenches for protection of cable complete all as specified and directed.
M&L for Sub main wiring in repairs with two runs of single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25 mm dia including one run of PVC insulated unsheathed 6.0 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall all as specified and directed. Note: Two runs of single core PVC insulated copper cable 6 sqmm size with one run of 6 sqmm copper earth cable and one run of PVC conduit 25 mm dia shall be measured as one unit length for purpose of payment.
M&L of earthing complete with GI steel earth plate electrode 60cm x 60cmx6.0mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI strip 32x6mm by means of nuts, bolts checks nuts and washers made of GI earth wire protected by GI pipe 40mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 using 20mm graded aggregate, pre-cast RCC (1:2:4) type-B, over slab 30cmx30cmx10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 3 of MES schedule Part-I and testing after completion.
M & L for Point wiring in repairs including with PVC insulated FRLS PVC unsheathed electric cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area for phase/neutral in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall & incl 1.5 sqmm green FR PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including galvanised boxes with bakelite sheet for mounting switches, sockets, fan regulators etc for the following :-
(a) One light/fan point controlled by one switch
(b) One 5amps socket out let point controlled by one switch on same board with other switches.
(c) One 5amps socket out let point on independent board controlled by one switch.
All as per item no 01 here in before but using pvc insulated unsheathed 2.5 sqmm cross sectional area cable for phase /neutral & for earth 2.5 Sq mm green PVC insulated cable for 15 amps socket point on independent board controlled by one switch.
S&F switch piano flush button single pole one way 5 Amp 240 volt complete as directed.
Supply and fix in repairs Socket outlet, multi purpose, 2 in 1, 3 Pin 5 Amps complete all as specified.
S&F switch piano flush button single pole one way 15 Amp 240 volt complete as directed.
S&F socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete as directed.
S&F ceiling rose surface bakelite three terminal complete all as directed.
Supply and fix LED tube lightfitting,1x20 Watt, 6000K, suitable for wall mounting wih aluminium housing & intregated electronic drivers , complete all as specified and directed.
Supply & Fix Electric ceiling fan capacitor type 1200 mm sweep, 230 Volts single phase, ISI marked,Energy efficient,white in colour, complete with all accessories like down rod, clamps etc all as specified and directed by Engr-in-Charge.
S&F for energy saving recess/surface mounted luminaire 36 W,Slim type(Edge-lite type) incl LED Driver, high efficiency, Ultra modern designed LED Luminaire which provides soft- glare free light and symmetrical illumination, suitable for Armstrong/Grid ceiling of 600X600 mm incl required suitable size of ceiling cut out, incl Provn of three core cable of copper conductor of size 1.5 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on ceiling including cutting, grooving with proper finish and making good, disturbed surface with all fixing arrangement complete all as directed (Make-Havells Cat No.ENDURASLIMPROPLUS2X2PLR28/36WLED840MOD or equivalent in Crompton/Philips.
Supply and fix single door SPN DB eight ways of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed by Engr-in-Charge.
Supply and fix MCB SPN 6 to 32 amps 10 KA, 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge.
Supply and fix MCB SP 6 to 32 amps 10 KA, 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge.
S&F( in building peripheri) energy efficient, compact street lighting 25 Watt LED with deep drawn Alluminium housing complete with conncting wire and provision of GI bracket, clamp, nuts, bolts grounded in wall incl all fixing arrangement complete as directed by Engr-In charge.
sunway associates
M/S UnitedConstruction
Goyal Construction
ss construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .