Loading…
Loading…
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
12 Sept 2026, 5:00 pm
Garrison Engineer
Garrison Engineer AF Thanjavur
REPAIR, MAINTENANCE OF EXTERNAL ELECTRIFICATION NETWORK AT DOMESTIC AREA AND CONNECTED WORKS AT AF STN THANJAVUR
2026_MES_785883_1
8305/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer AF Thanjavur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer
₹58,000
22 Aug 2026
22 Aug 2026
19 Sept 2026
22 Aug 2026
12 Sept 2026
5 Sept 2026
22 Aug 2026 - 28 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fix in replacement Off load/bypass change over switch 200 amps 415 volts 4 pole 50 Hz in sheet metal with out side handle operated complete all as per C&S cat part No CSCSCF200CO4 or equivalent as specified in PS complete all as specified and as directed. | 1 | Each | - | - |
| 2 | Supply and fix in replacement Off load/bypass change over switch 100 amps 415 volts 4 pole 50 Hz in sheet metal with out side handle operated complete all as per C&S cat part No CSCSCF100CO4 or equivalent as specified in PS complete all as specified and as directed. | 1 | Each | - | - |
| 3 | Supply and fix in replacement On load change over switch 200 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated completeall as per C&S cat part No CSCS200NM4CO or equivalent as specified in PS complete all as specified and as directed. | 1 | Each | - | - |
| 4 | Supply and fix in replacement On load change over switch 160 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated completeall as per C&S cat part No CSCS160NM4CO or equivalent as specified in PS complete all as specified and as directed. | 1 | Each | - | - |
| 5 | Supply and fix in replacement On load change over switch 125 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated completeall as per C&S cat part No CSCS125NM4CO or equivalent as specified in PS complete all as specified and as directed. | 2 | Each | - | - |
| 6 | Supply and fix in replacement On load change over switch 100 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated completeall as per C&S cat part No CSCS100NM4CO or equivalent as specified in PS complete all as specified and as directed. | 1 | Each | - | - |
| 7 | Supply and fix in replacement MCCB 4 pole adjustable type 630 amps rupturing capacity 65 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CS630NFMU4P or equivalent as specified in PS complete all as specified and as directed. | 2 | Each | - | - |
| 8 | Supply and fix in replacement MCCB 4 pole adjustable type 400 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSE3NN400ATM4P or equivalent as specified in PS complete all as specified and as directed. | 4 | Each | - | - |
| 9 | Supply and fix in replacement MCCB 4 pole adjustable type 320/350 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSE3NN400ATM4P or equivalent as specified in PS complete all as specified and as directed. | 3 | Each | - | - |
| 10 | Supply and fix in replacement MCCB 4 pole adjustable type 250 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSE2SX250ATM4P or equivalent as specified in PS complete all as specified and as directed. | 4 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TenderDocuments8305.pdf
Tender Documents • 1.19 MB
BOQ_880653.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].