| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.5 LAdmitted-Finance | ₹92.5 L | L1 | Admitted-Finance |
| 2 | L2₹96.8 LAdmitted-Finance 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | ₹96.8 L | L2 | Admitted-Finance |
| 3 | L3₹1.1 CrAdmitted-Finance PLOT NO 13 SHAKTI KHAND II INDRAPURAM GHAZIABAD 201014 | GHAZIABAD | UTTAR PRADESH | 201014 | ₹1.1 Cr | L3 | Admitted-Finance |
| 4 | L4₹1.2 CrAdmitted-Finance G 102 PLOT NO 123 SECTOR 06 VAISHALI GHAZIABAD U P 2010 | 2010 | ₹1.2 Cr | L4 | Admitted-Finance |
| 5 | L5₹1.2 CrAdmitted-Finance 8 34A FATHIMAPURAM TAMILNADU | TAMILNADU | ₹1.2 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Aditya Techno Products Private Limited L4 | FATHIMA ENGINEERING.COM L5 | MPC ELECTRICALS AND ENGINEERS L6 | DQBYDT PVT LTD L3 | ABHISHEK INTEGRATIONS LIMITED L2 | Reliable Engineers L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.10 | Supply and laying of 3x240Sqmm, 22KV, HTUG Cable with stranded compacted circular aluminium conductor, XLPE insulated, sheathed, extruded semi conducting compound followed by a layer of copper tape, cores laid up with fillers, wrapped layer of copper tape, thermoplastic tape inner sheathed single galvanized flat steel strip armoured and overall confirming to IS:7098(II)/1985, in a trench to be excavated/trench along with making suitable cushioning/clamping arrangement as directed by the Engineer in charge. | 800 | Mtr | 2,247 ₹18.0 L | 2,275 ₹18.2 L | 3,500 ₹28 L | 2,600 ₹20.8 L | 2,570 ₹20.6 L | 1,300 ₹10.4 L |
| 2.10 | Supply and laying of 3x120Sqmm, 22KV, HTUG Cable with stranded compacted circular aluminium conductor, XLPE insulated, sheathed, extruded semi conducting compound followed by a layer of copper tape, cores laid up with fillers, wrapped layer of copper tape, thermoplastic tape inner sheathed single galvanized flat steel strip armoured and overall confirming to IS:7098(II)/1985, in a trench to be excavated/trench along with making suitable cushioning/clamping arrangement as directed by the Engineer in charge. | 1,200 | Mtr | 1,559 ₹18.7 L | 1,596 ₹19.2 L | 2,420 ₹29.0 L | 1,800 ₹21.6 L | 1,702 ₹20.4 L | 1,200 ₹14.4 L |
| 3.10 | Charges for excavation/removal and re-routing and relaying of various sizes of 3x70/120/240Sqmm HT/LT Cables available at an existing trench/excavation/removal and refixing of RCC slab and re-routing the same cables in a trench to be excavated/trench along with making suitable cushioning/clamping arrangement as directed by the Engineer in charge. Removal of cable and rerouting the same to sprinkler pump house for alternative power supply. | 7,600 | Mtr | 325 ₹24.7 L | 400 ₹30.4 L | 440 ₹33.4 L | 200 ₹15.2 L | 60 ₹4.6 L | 450 ₹34.2 L |
| 4.10 | Supply & providing 3x240sqmm, 22KV HTUG Heat shrinkable straight through and making good of the existing earth in a good condition. | 4 | Set | 53,895 ₹2.2 L | 22,150 ₹88,600 | 22,400 ₹89,600 | 8,190 ₹32,760 | 46,155 ₹1.8 L | 29,000 ₹1.2 L |
| 5.10 | Supply & providing 3x120sqmm, 22KV HTUG Heat shrinkable straight through jointing kit and making good of the existing earth in a good condition. | 4 | Set | 48,618 ₹1.9 L | 20,440 ₹81,760 | 21,500 ₹86,000 | 6,000 ₹24,000 | 42,815 ₹1.7 L | 25,000 ₹1 L |
| 6.10 | Supply and laying of 31/2 x 240 sqmm, PVC armoured aluminium LTUG Cable in a trench to be excavated/trench along with making suitable cushioning/clamping arrangements as directed by the Engineer in charge. It is also using interconnecting from SS.13/16 to SDB. | 2,550 | Mtr | 1,519 ₹38.7 L | 1,603 ₹40.9 L | 1,700 ₹43.4 L | 1,980 ₹50.5 L | 1,635 ₹41.7 L | 860 ₹21.9 L |
| 7.10 | Supply, erection, testing and commissioning of Stainless-Steel floor mounting type pillar box along with providing suitable foundation concrete and required bolt and nuts for fixing the distribution panel as per the technical specifications. | 3 | Set | 3,70,000 ₹11.1 L | 1,85,000 ₹5.5 L | 3,50,000 ₹10.5 L | 51,000 ₹1.5 L | 1,68,850 ₹5.1 L | 3,00,000 ₹9 L |
| 8.10 | Supply and fixing of brass cable gland for 31/2x240sqmm PVC armoured LTUG Cable with earth connection. | 30 | Set | 2,690 ₹80,700 | 1,850 ₹55,500 | 1,250 ₹37,500 | 4,000 ₹1.2 L | 1,830 ₹54,900 | 540 ₹16,200 |
| 9.10 | Earthing as per the ISI Specification: Earthing with 1.5Mtr length, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc., with charcoal/coke/salt as required. | 6 | Set | 6,700 ₹40,200 | 16,500 ₹99,000 | 21,000 ₹1.3 L | 6,500 ₹39,000 | 7,020 ₹42,120 | 4,800 ₹28,800 |
Tender Value
₹97.9 L
EMD Value
₹2.0 L
Closing Date
8 Dec 2025, 3:00 pmClosed
CME
CME CME chamber VOCPA
Removal and relaying of HT/LT UG Cables for widening of Approach Road from Green Gate to entrance of 7th Berth of VoCPA
2025_VOCPT_255492_1
MEE/ELEC0ESTW/44/2025/Mech SE1/7963
Open Tender
Electrical Works
120 days
VOCPA
As per the tender conditions
17 documents required · 17 mandatory
₹0
₹2.0 L
Yes
7 Apr 2026
14 Nov 2025
9 Dec 2025
14 Nov 2025
8 Dec 2025
14 Nov 2025
Supply and laying of 3x240Sqmm, 22KV, HTUG Cable with stranded compacted circular aluminium conductor, XLPE insulated, sheathed, extruded semi conducting compound followed by a layer of copper tape, cores laid up with fillers, wrapped layer of copper tape, thermoplastic tape inner sheathed single galvanized flat steel strip armoured and overall confirming to IS:7098(II)/1985, in a trench to be excavated/trench along with making suitable cushioning/clamping arrangement as directed by the Engineer in charge.
Supply and laying of 3x120Sqmm, 22KV, HTUG Cable with stranded compacted circular aluminium conductor, XLPE insulated, sheathed, extruded semi conducting compound followed by a layer of copper tape, cores laid up with fillers, wrapped layer of copper tape, thermoplastic tape inner sheathed single galvanized flat steel strip armoured and overall confirming to IS:7098(II)/1985, in a trench to be excavated/trench along with making suitable cushioning/clamping arrangement as directed by the Engineer in charge.
Charges for excavation/removal and re-routing and relaying of various sizes of 3x70/120/240Sqmm HT/LT Cables available at an existing trench/excavation/removal and refixing of RCC slab and re-routing the same cables in a trench to be excavated/trench along with making suitable cushioning/clamping arrangement as directed by the Engineer in charge. Removal of cable and rerouting the same to sprinkler pump house for alternative power supply.
Supply & providing 3x240sqmm, 22KV HTUG Heat shrinkable straight through and making good of the existing earth in a good condition.
Supply & providing 3x120sqmm, 22KV HTUG Heat shrinkable straight through jointing kit and making good of the existing earth in a good condition.
Supply and laying of 31/2 x 240 sqmm, PVC armoured aluminium LTUG Cable in a trench to be excavated/trench along with making suitable cushioning/clamping arrangements as directed by the Engineer in charge. It is also using interconnecting from SS.13/16 to SDB.
Supply, erection, testing and commissioning of Stainless-Steel floor mounting type pillar box along with providing suitable foundation concrete and required bolt and nuts for fixing the distribution panel as per the technical specifications.
Supply and fixing of brass cable gland for 31/2x240sqmm PVC armoured LTUG Cable with earth connection.
Earthing as per the ISI Specification: Earthing with 1.5Mtr length, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc., with charcoal/coke/salt as required.
stage.html
html • 0.04 MB
techsummary_294354.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
tenderhtltcablerem.pdf
Tender Documents • 1.08 MB
BOQ_294354.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid