Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹50.0 L
EMD Value
₹99,900
Closing Date
13 Oct 2026, 6:00 pm3d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE (West) Lucknow
GE (West) Lucknow PIN-226002
REPAIR / COMPREHENSIVE MAINT OF B/R AND E/M SERVICES AT VIVEK VIHAR COLONY UNDER GE (WEST) LUCKNOW
2026_MES_790544_1
GE/W/LKO/T-114 OF 2026-27
Open Tender
Civil Works
Item Rate
270 days
GE (West) Lucknow
As per NIT and Tender documents
8 documents required · 8 mandatory
₹500
Lucknow
₹99,900
Yes
22 Sept 2026
22 Sept 2026
15 Oct 2026
22 Sept 2026
13 Oct 2026
6 Oct 2026
22 Sept 2026 - 29 Sept 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GE (WEST ) Lucknow
Name of Work : REPAIR / COMPREHENSIVE MAINT OF B/R AND E/M SERVICES AT VIVEK VIHAR COLONY UNDER GE (WEST) LUCKNOW
Contract No: GE/W/LKO/T-114 OF 2026-27
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2 M & for Plain Cement Concrete 1:2:4, Type B0 (using 12.5 mm graded granite stone aggregate) in copings, kneelers, including weathering, slightly rounded or chamfered angles and throating, as directed incl demolition of PCC completele all as specififed and directed 1 Cum Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
66 S&F in repair 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and taking down old one complete all as specified and as directed 40 Each Excess(+) Full Conversion INR
130 Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 2.5 Qtl Excess(+) Full Conversion INR
150.1 (c) The complaints related to carpenter works, plumbing works, cement works and welding works against serial item Nos 148 to 150 shall be completed in 48 hours time after lodging/ receipt of complaints. Contractor shall ensure that all the complaints shall be attended and completed within above prescribed schedule/ time period, failing which, a penalty at the rate of double the quoted rate for that particular trade work/complaint per day till the satisfactorily completion of complaint shall be levied on the contractor and recovery for the same shall be affected from contractor's dues. A separate register shall be maintained for recording recovery for compliant not attend with in time period by the JE Remaining clauses pertaining to the register same as per para 150 (a) above. (d) For each complaint, a separate complaint slip shall be prepared by JE/ his representative and handed over to related tradesman, etc. for attending the complaint and after satisfactorily completion of complaint, compaint slip shall be submitted to concerned executive on the date as per Para 150 (b) above, which shall be got signed from the occupant and shall be produced at the time of payment to be made to the contractor. Complaints pertaining to same location and same nature consisting of replacement of maximum two fixtures in one quarter/ office/ building etc.involving movement of particular tradesman shall be measured and paid as one complaint. Replacement of more than two fixtures but multiple of three fixtures or part thereof in one quarter/ office/ building, etc. shall be measured as additional complaint. (e) Ref Para 150 (c) above any compliant of cement work below one Sqm will be given as single complaint, multiple of the same will be given as additional complaint.
150.2 (f) Complaint slip and complaint register etc. shall be provided by the contractor without any extra cost to the department and cost there of shall be deemed to be included in quoted rates by the contractor against respective items. (g) Necessary transportations, tools, plants, ladders, including nails, screws, PVC washers, brass spindle, for bib taps/ stop cocks/ pillar cocks, cotton thread, Jumper valves, white lead, flush washers, internal fitting of low level flushing cistern, nipple, tee, elbow, plug, socket, reducer (GI/UPVC), M-seal, glass putty, hinges, handle, tower bolt, stopper, cement, white cement, sand other similar minor accessories required to complete the jobs/complaints shall be provided by the contractor without any extra cost to the department and cost there of shall deemed to be included in quoted rates by the contractor against respective item of schedule 'A'. (h) Contractor will establish a well furnished complaint cell to recieve the complaints (Petty repair) in the area allocated by Enginner-in-Charge/GE. (j) Contractor will deploy a Data Entry operator staff to recieve the complaints made by users in complaint cell from time 9:00 AM to 17:00 PM on all working day. (k) Contractor will deploy sufficient plumber/ Carpentor/Mason/safaiwala/electrician to attned the daily complaints (petty repair) on daily basis. Attendance report of the deployed skilled staff alongwith their healper will be submiited to JE/Engineer-in-Charge on daily basis. (l) Contractor's supervisor will report on all working days alongwith their skilled staff and printed contractor's firm name complaint slip book at 8:30 hrs at JE/Engineer-in-Charge received complaints from users and to submit completion report/constraints, if any on the same day by 1700 hrs.
150.3 (m) Printed complaint slip book as per format approved by Engineer-in-charge shall be provided and maintained by the contractor. (n) If there is any major complaints of tilling/Plumbing/Joinery/ electrician/BS for which additional times/manpowers or T&P as required the same shall be provided by the contractor without any extra cost to Govt. The same will be reoprted to JE/Engineer-in-Charge for taking consent. (o) If the complaints will not be attended a recovery @ Rs. 700 per day shall be recovered from the amount due to the contracor. (p) Store for attending the complaints will be provided by the contractor on daily basis. (q) The contractor will submit the RAR alongwith Completion report of comaplints (petty repair) duly signed by the users and also attendence sheet of deployed plumber/carpentor/mason/electrician alonwith their helper duly signed by JE/Engineer-in-Charge. (r) The RAR will be proceed only after verfication of resolved complaints at the site by JE/Engineer-in-Charge. (s) Rate quoted in above BOQ shall be deemed to incl the cost of office staff/ office equipment, required T&P/stores and device etc alongwith sufficinet skilled manpowers/ labour to attend/complete the complaints in the same day duly signed by users at the entire satisfaction of Engineer-in Charge. (t) It is adivsed to contractor to visit the site before quoting the rates in tender.
191 Supply only in replacement bell push, flush type, single pole, one way 5/6 Amp, 230 volt flush type complete all as specified and directed. 16 Each Excess(+) Full Conversion INR
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
TenderT-114.pdf
Tender Documents • 1.33 MB
BOQ_886222.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .