Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹5.4 LAccepted-AOC | 1st | Accepted-AOC The lowest bidder M/s Agrawal Builders has been accepted please. | |
| 2 | 2nd₹5.5 L+₹5,061 (0.94%)Rejected-Finance | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹6.8 L+₹1.4 L (25.0%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | 3rd | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
14 Jan 2021, 6:00 pmClosed
GE AWC MHOW
GE AWC Mhow Baircha Road Mhow Cantt
PROVISION OF CERTAIN E/M REVENUE AND MINOR WORKS UNDER GE (AWC) MHOW
2020_MES_404603_1
8447 GE(AWC) /MHOW / OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE AWC MHOW
All as per Tender Documents and NIT.
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹12,000
Yes
28 Jan 2021
17 Dec 2020
15 Jan 2021
18 Dec 2020
14 Jan 2021
1 Jan 2021
Amount
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cable and fixing pole, stays etc and getting out complete all as specified and directed.
Excavating in trenches exc 1.5m wide but exc 1.5m and n exc 3.0m deep for foundation of poles strut/stays etc n exc 10 sqm on plan and getting out in any type of soil.
Returning, filling in includiing spreading levelling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exc 50 mtr and depositing where directed at level not exc 1.5mtr above the starting point complete allas specified and directed.
M&L river washed and screened dry fine sand filling in trenches below and above / around under ground cable for cable protection, in duct under & abobe the cables including punning around cable complete all as specified and directed.
M & L for unreinforced PCC Cable protection cover , Class LV ,Type1 flat , size 250 x 150 x 40 as cable protection laid flat width wise complete all as specified and directed.
M&L for cement concrete1:4:8 type D2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in coping & the like etc. including weathering slightly rounded / chamfered angle with & including necessary use & waste of form wk for fair finished surfaces complete all as specified and directed.
Supply and laying galvanised iron pipe 'light Grade' 40 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings, including sealing ends complete all as specified and directed .Make Jindal/Prakash Surya/Tata
Supply and laying galvanised iron pipe 'light Grade' 50 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings, including sealing ends complete all as specified and directed .Make Jindal/Prakash Surya/Tata
Drilling (Horizontally) existing road (Maximum 10 mtr wide) suitable for passing GI tubing 40 mm complete as specified.Note GI pipe shall be measured and paid separately.
Drilling (Horizontally) existing road (Maximum 10 mtr wide) suitable for passing GI tubing 80 mm complete as specified.Note GI pipe shall be measured and paid separately.
Supply and Fixing steel tublar pole with cast iron base plate, 410-SP-31, as per sample of length 09 Mtrs duly painted, finial taper plug,bolts, nuts,& screws complete all as specified and directed.Make- NTC Kanpur/Bharat Conduit/ BCW Kanpur
Supply, laying or fixing, jointing and testing LT under ground electric power cable of size 10 Sqmm, 4 core. Crossed linked polyethylene (XLPE Cable ) insulated, galvanised steel strip or wire armoured, ISI -7098 Marked. With aluminium conductor multi stranded , heavy duty 1100 Volts grade of following sizes and core , complete all as specified laid in tenches / laid under floor or fixed with walls/ on poles/ in ducts/ in GI pipes including taking down existing complete all as directed at site.
Supply, laying or fixing, jointing and testing LT under ground electric power cable of size 16 Sqmm, 4 core. Crossed linked polyethylene (XLPE Cable ) insulated, galvanised steel strip or wire armoured, ISI -7098 Marked. With aluminium conductor multi stranded , heavy duty 1100 Volts grade of following sizes and core , complete all as specified laid in tenches / laid under floor or fixed with walls/ on poles/ in ducts/ in GI pipes including taking down existing complete all as directed at site.
Supply, laying or fixing, jointing and testing LT under ground electric power cable of size 25 Sqmm, 4 core. Crossed linked polyethylene (XLPE Cable ) insulated, galvanised steel strip or wire armoured, ISI -7098 Marked. With aluminium conductor multi stranded , heavy duty 1100 Volts grade of following sizes and core , complete all as specified laid in tenches / laid under floor or fixed with walls/ on poles/ in ducts/ in GI pipes including taking down existing complete all as directed at site.
Supply and fix LED street light 90 W including IP 65 all as complete all as specified & directed Make Bajaj Cat part No- BRTFG 90W LED I V2 & HAVELLS Endura Omni Cat part LHETASU7PA6J090
Supplying and fixing in replacement of PVC junction box of size 200mmX160mmX98mm , including connector block , two holes for incoming and outgoing cables, providing cable glands double compression as per requirement, providing DIN rail for mounting MCB and Clamps made out of MS FI 25X4mm, MS hexagonal bolts, nuts and washers for arrangements to pole/ surfaces complete all as specified and directed by Engr-in-Charge. (Make-Hensel /Syntex/ Siemens)
Chitragupta Construction
S.S. Engineers
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .