Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹4.3 Cr
EMD Value
₹8.6 L
Closing Date
28 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Executive Engineer M/Garh W.S. Mech. Divn., Narnaul, 123001
Supply, Erection and commissioning of new 60 Cs VT Axial Flow Pumps with 325/350 HP LT motor alongwith allied electro-mechanical assessories at Pump Houses ND-1 of M/Garh W/S Mech Division, Narnaul.
2026_HRY_554290_1
5406-19/9-A Dated 09/10/2026
Open Tender
Pumps/Motors
Works
365 days
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹8.6 L
Yes
XEN M/GARH W.S MECH. DIVISION, NARNAUL
14 Oct 2026
14 Oct 2026
29 Oct 2026
14 Oct 2026
28 Oct 2026
14 Oct 2026
22 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Erection and commissioning of 60 Cs V.T. axial flow pump of lift height 23.02’ (Plus(+) 5 feet extra keeping in view of New Pump House) including MS Delivery pipe, bend, syphon breaker valve & support of bend as per site requirement & specification approved by the department (Annexure-A) PH ND-1=3 | 3 | No | - | - |
| 2 | Supply, Erection and commissioning of 325/350 HP induction motors suitable for 60 Cs VT axial flow pumps, 262 KW, 730 RPM, 440/415 voltage, 3 phase, 50 Hz bearing SKF / FAG as per specifications (Annexure-B) and site requirements Pump house ND-1=3 | 3 | No | - | - |
| 3 | Providing & fixing by making required size /length at site in pair of MS cross Girder (ISMB) of size 500mmx180mmx10mm for foundation of 60 CS VT Axial Flow pump including supply,fixing & welding on bottom side of ISMB through out length with MS flat of 180mmx20 mm thick. One end of ISMB shall be grouted into wall by making arrangement Of PCC block of suitable size as per weight of pump set of 60 Cs capacity and other end shall be welded with fixing of A.I. L- bracket and nut/bolts/washers etc fitting with ISMB member. Including Material & Labour for applying primer coat with metal primer on new steel or iron work including preparation of surface and Material & labour for painting two coats excluding primer coat with ready mixed paint (Epoxy paint) for metallic surface in all shades on new steel or iron work..MAKE: TATA/JINDAL/SAIL/VAIZAG Pump house ND-1=3 | 3 | Pair | - | - |
| 4 | Providing & fixing by making required size /length at site ISMB of size 600mmx210mm for support of foundation girder for 3 Nos 60 Cs VT Axial Flow pump including supply,fixing both end of ISMB shall be grouted into wall by making arrangement Of PCC block of suitable size as per weight of pump set of 3 Nos 60 Cs. Including Material & Labour for applying primer coat with metal primer on new steel or iron work including preparation of surface and Material & labour for painting two coats excluding primer coat with ready mixed paint (Epoxy paint) for metallic surface in all shades on new steel or iron work. Taking down by cutting / welding the existing rusted/ old foundation girder for fixing new girder at site.MAKE: TATA/JINDAL/SAIL/VAIZAG Pump house ND-1=1 | 1 | No. | - | - |
| 5 | Supply, laying and installation of LT 1100 Volts Cable PVC XLPE armoured Aluminium Conductor of size Single Core 1000 Sq. MM as mentioned as per relevant IS specification & approved make in technical specification of Haryana Irrigation Deptt. (PH ND-1) | 2,000 | Mtr. | - | - |
| 6 | Supply, laying and installation of LT 1100 Volts Cable PVC XLPE armoured Aluminium Conductor of size Single core 300 Sq. MM as mentioned as per relevant IS specification & approved make in technical specification of Haryana Irrigation Deptt. (PH ND-1) | 400 | Mtr | - | - |
| 7 | Supply, laying and installation of LT 1100 Volts Cable PVC XLPE armoured Aluminium Conductor of size Single core 630 Sq. MM a mentioned as per relevant IS specification & approved make in technical specification of Haryana Irrigation Deptt. (PH ND-1) | 300 | Mtr | - | - |
| 8 | Providing & Fixing of Lightening arrester with protection radius of 100 mtr alongwith copper arrangement as per proper specifications of Pump House Building / site requirement with counter device/measuring device. (1 No. at Pump house ND-1) | 1 | No. | - | - |
| 9 | Supply, erection and commissioning of LTDB panel of 1600 Amp. Capacity with all accessories as one Incomer ACB 4 pole 1600 Amp. with 4 No. outgoing each suitable for 325/350HP motors each with 4 No fulley automatic ATS starters suitable for operation of 325/350 HP motors suitable size of contactor rating with designed capacitor bank of suitable capacity capacity with 8 step APFCR, digital display instruments & other allied accessories for automatic as well as manual operation of capacitor bank suitable for 3 Nos. 325/350 HP motors for each panel, with a stand of MS Channel (1 ft. Up from floor) & as per approved technical specification (Annexure-C) with earthing(PH ND-1) | 1 | No. | - | - |
| 10 | Providing and fixing of chemical Earthing by digging diameter 200 mm, complete with G.I. electrode with GI strip of suitable length of approx. 500ft. (01 No. for panel and 04 No. for motors in the new pumphouse) with proper specification and proper wiring with all allied accessories etc along with name plate complete as per site requirement. (1 No. at Pump house ND-1) | 1 | No. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.53 MB
BOQ_634202.xls
BOQ • 0.28 MB
Bidbook11.pdf
Additional Documents • 0.34 MB
Annexures.pdf
Other Document • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .