EEE-III/RZ
EEE-III/RZ
Installation of CCTV Surveillance system in MC Primary School ward No 41, Aman vihar
2023_MCD_179093_1
EEE-III/RZ/TC/2023-24/18.1
Open Tender
Electrical Works
Item Rate
120 days
EEE-III/RZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹15,908
30 Apr 2025
23 Dec 2023
29 Dec 2023
23 Dec 2023
28 Dec 2023
23 Dec 2023
Amount
122.2.47:"SITC of 4MP fixed lens Bullet IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better** S/N ratio: >45 dB Lens: 2.8mm fixed Video Compression: H.265 or better** Resolution: (2650x1440) or better** Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 30m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard: IP66 or better** Safety standard: UL "
122.2.53:"SITC of 4MP PTZ Camera with following specifications:- Image Sensor: 1/2.8 2MP CMOS or better** Minimum Illumination: 0.1 lux color, 0 lux with IR or better ** Shutter Speed:1/3 - 1/50,000 s Frame Rate:25 fps or better ** Lens: 30 X ZOOM Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (1920x1080) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 20m Operating Temperature: -20 to 55 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL "
122.2.68:SITC of 10 TB surveillance HDD
122.2.60:"SITC of 32 channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better** Network Throughput :200Mbps or better** USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 2 SATA port suitable for 6TB each Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL "
122.2.62:SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch
122.2.70:"SITC of full HD LED Monitor,42 INCHES complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 300 NITS min. Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz at site with connections and along with all accessories etc. complete as required. "
122.2.77:SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 3KVA
122.2.80:SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.6 U
122.2.82:SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U
122.2.72:SITC of IP65 box (without PoE switches)of dimention 310mmX160mmX140 mm on pole or wall with suitable arrangement for support/installation of 8 port Giga PoE switch and 1 nos. 15/16 amp modular switch socket set
122.2.25:Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required
OD19815/2023-2024: (1.32) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
OD19816/2023-2024: (1.17.11) S/D of following size of FRLS PVC insulated copper conductor ,Single core cable in the existing surface /recessed steel/PVC conduit as required . 2 x2.5 sq.mm
OD19818/2023-2024: (1.21.3)Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 32 mm
OD19819/2023-2024: (1.21.2)Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm
OD19955/2023-2024:(1.53.2) Supplying and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 2 run of cable
OD19956/2023-2024:(1.53.1) Supplying and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 1 run of cable
110.10:Providing and fiving name board made of MS Sheet 90x60cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30m embedded in CC block 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction of Engineer-in-Charge
JINDAL INDUSTRIES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .