SPECIAL REPAIRS TO MT LIVING BARRACK No. BK 17 AT BAKLOH CANTT UNDER AGE I DALHOUSIE
2022_MES_499295_1
8845/2021-22/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) Dalhousie
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Dalhousie
₹24,200
Yes
AGE(I) Dalhousie
6 Apr 2022
4 Jan 2022
5 Feb 2022
4 Jan 2022
3 Feb 2022
19 Jan 2022
4 Jan 2022 - 14 Jan 2022
14 Jan 2022
Amount
Demolition of cement concrete in ground floor and paving n.exc 15 cm thick above or below ground level (unreinforced).
Demolition of stone, brick masonry built in cement mortar incl quoins, arches, etc but exceeding ashlar facing dressed stone Work etc.
Dismantling CGI or PGI sheet of any gauge and thickness or any pattern roof covering.
M&L PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection 75 mm thick incl finished even & smooth without using extra cement complete all as specified.
Cement concrete 1:2:4 type B1 ( using 20 mm crushed stone agg.) as in floor 40 mm thick as levelling course rough finish to receive top finishes all as specified to recd top finishing complete all as specified.
Cement concrete 1:2:4 type B0 ( using 20 mm crushed stone agg.) as in floor 25 mm thick as levelling course rough finish to receive top finishes all as specified to recd top finishing complete all as specified.
M&L screed bed 15 mm thick in cm 1:6 for bedding layer to floor tiles
M&L for coloured Matt finish Non skid ceramic tile (Joint free) area of each tile exe 0.18sqm but n exe 0.38 sqm x 7 to 8mm thick , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match.
RR masonry with best quality locally available stone uncoursed, well bonded, bedded, solidly hearted and built in CM 1:4 complete all as specified.
All as per item No 09 above but except stones
Taking down cement plaster from stone/brick walls, racking out joints hacking for key, scrubbing down with water etc
20mm thick cement plaster on Stone/ concrete surfaces or fair surface face of brick work in CM 1:4 surface finished even and smooth without using extra cement
20 mm thick cement plaster Stone / concrete surfaces or fair faces of brick work in CM (1:6) surface finished even and smooth w/o using extra cement.
M&L for applying two coats of oil bound distemper on wall on new plasted surfaces including preparation over a coat of Birla wall putty and a coat of JK Primer all as specified {(Make : Goodlass Nerolac (Super Acrylic), Asian Paints(Tractor Acrylic Distemper), Berger Paints (Bison Super)}
M&L for two coats of OBD over complete removal of existing treatment and wall putty base on old plaster surface including preparation over a coat of Birla wall putty and a coat of JK Primer all as specified {(Make : Goodlass Nerolac (Super Acrylic), Asian Paints(Tractor Acrylic Distemper), Berger Paints (Bison Super)}
M&L for applying two coats of cement base paint over priming plastered surfaces with JK primer priming coat complete all as specified.(Make : Snocem, Asian, Berger)
M&L for Two coat of cement base paint on old plastered surface of wall after the necessary preparation. (Make : Snocem, Asian, Berger)
Rolled sections as in Main and cross beams hip and jack rafters , Purlins where connected to commen rafters and guide for siding d, etc conforming to Fe-410 W (Gde-E-250) quality B all as directed
Preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide all as specified
M & L for 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L- type or J- type or cranked hook bolts and washers, in roofs, walls etc. with grade of zinc coating 275.
M & L for Galvanised plain mild steel sheeting of thickness 0.63mm grade O with 120 gm/sqm Zinc coating with L or J type or cranked hooks and washers bitumen washer as in ridge etc
Taking down chowkats or frames incl shutters (without taking off shutters from frame) n exc 1.5 Sqm
All as per item No 22 above but exc 1.5 sqm but n exc 4 sqm each
2nd class soft wood ( kail ) as in plain fillets, square rectangular or triangular in section fixed with screws exceeding 6 and nexc 13 sqcm wrought all as specified.
IInd class hard wood (Sal, Hollock) plain solid, straight, Chowkat and frames, wrought, framed, rebated on the solid , rounded or chamfered, put together with glue, pinned at joints all as specified
IInd class hard wood glazed and skelton shutters 30mm thick, open rebated and prepared to receive glass or gauze etc (without sash bar) and fitted to chowkats, edges of framing plain chamfered or rounded fitted with cut and mitred bead for securing glass,divided into squares with plain chamfered or rounded mitred and rebated sash bars with stiles and rails as specified in SSR Part-I section 8.24 (b) as in windows, ventilators.
Flush shutters, 30 mm thickness solid core construction, with block board core and ply wood face panels, commercial type on both sides (Make : Swastik Ply Wood, Century Plywood)
100mm size butt hinges medium weight colled rolled mild steel (ISI Marked)
S/F 200 mm long aluminium anodised barrel tower bolt of extruded section and fixed
M&L150 mm size Aluminium handle, cast type, anodised and fixed.
S/F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp and stape ( bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolt and sliding bolt of extruded section or cast aluminium alloy and fixed.
Two coat of synthetic enamel paint over a coat of pink primer on new wood or wooden surfaces of any description over 10cm in width or girth not otherwise described including preparation(Make : Goodlass Nerolac Paints, Berger Paint, Asian Paints)
M&L for preparation of old painted surfaces of steel or iron of any description, over 10 cm width or girth and applying one coats of synthetic enamel paint.
S&f in repair galvanised steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples
S&F in repair 3mm thick plain sheet glass ordinary quality and glazing with oil putty or beading etc in square not exceeding 0.5 sqm in each pane
Demolition of Concrete of any description and in any position for drain
M&L Cement concrete 1:2:4 type B-2, using 40 mm graded crushed stone aggregates as in surface channel and drains, complete all as spd.
M&L Extra for forming fair finished drain or drain channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred stopped ends etc complete all as speciied and directed.
Taking down carefully copper/aluminium point wiring (light ,fan,socket or power) complete fixture and fittings such as switches ,ceiling rose, regulators,sockets etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separatly) and making good disturbed surfaces of wall, floors etc.
M & L for point wiring with copper conductor cable multistrand, PVC sheathed 1.5 Sqmm size(two run with colour code RYB) for one light point ,fan point, exhaust fan point,or bell point controlled by one switch including one run of 1.5 Sqmm (as continous earth wire Green)multistrand PVC concealed conduit of approved size and quality ISI marked,including all other required accessories as specified in preamable 1(a) to (q) of section 19 of SSR Part-II under heading 'point wiring' fixedon wall/ceiling including sunk cast iron terminal boxes grouting/flushing on wall for mounting fittings like switch,sockets etc covered with 3.00 mm thick plastic laminated sheet top cover of brick masonary/Stone masonary wall complete including cutting,chasing,pinning and making good the disturbed surface by using cement mortar 1:3 complete all as specified and directed by Engr-in-charge.Make of wire/cable-Havells/Anchor/Finolex,(Note:-the rate for concealed type point wiring shall deemed to include the cost of cutting,chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plasterand matching the surface by white wash/colour wash all as per existing finishes complete).
All as per Srl item No 40 here in before but for one 5 amps socket out let on same board.
All as per Srl item No 40 here in before but for one 5 amps socket out let on independent board.
All as per item No 42 above but for power point 3 pin switch socket 16 Amp with PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm(two run with colour code RYB) on independent board including one run of 2.5 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in cocealed PVC conduit of appropriate size and best quality ISI marked, including all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading "Point wiring" fixed on wall including sunk cast iron or PVC terminal boxes for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed.
Supply & Fixing Switch piano, flush button, single pole one way 6 Amps
Supply & Fixing Socket outlet 3 pin, 6 amps flush type.
Supply & Fixing Switch piano, flush button, single pole one way 16 amps
Supply & Fixing Socket outlet 2 in 1,3 pin 5 and 16 amps flush type.
Supply and fix ceiling rose 65X50 mm two to three terminals complete all as specified.
Supply and fix lamp holder for batten/angle fitting.complete all as specified and as directed
S & F Wall mounted LED integrateg batten fitting T5, 20 W LED, 4 feet, PVC extruded. Havells cat part no. LHEXBLP7PN1W020 ,C&S Cat part No LTTB4F20WLEDP/W or LL20-221-XXX-65NE3 of wipro or equivalent in CG/Phillips including all accessories complete all as specified.
S & F Wall mounted LED integrateg batten fitting T5, 9/10 W LED, 2 feet, PVC extruded.Havells cat part no. LHEXBLP7IN1W009 C&S Cat part No LTTB4F10WLEDP/W or LL20-111-XXX-65NE3 of wipro or equivalent in CG/Phillips including all accessories complete all as specified.
S & F LED lamp 10 watts CP NO:- LHLDEUHEMK8P010 of Havells or equivalent in Philips/Bajaj/Crompton/Wipro all as specified and as directed.
Supply and fixing LED building security light fitting with suitable size bracket/angle to fit security light of 35w IP 66 protection LED make bajaj/ Havells etc. complete all as specified and directed.
Supply & Fixing Sheet metal enclosure for DB,s, double door (when MCB,s to be used) Triple pole & neutral 4 way with 200 amps rated bus bar 415 volts with fixing arrangements including taking down ICDP/DB's any type including taking down of kitkat fuse/MCB SPN/SP as directed by Engineer-in-charge. Cat Part No CSDBSPNSD08 of C&S, or equivalent in Havells/Legrand
Supply & Fixing Sheet metal enclosure for DB,s, double door (when MCB,s to be used) single pole & neutral 8 way with 200 amps rated bus bar 240 volts with fixing arrangements including taking down ICDP/DB's any type including taking down of kitkat fuse/MCB SPN/SP as directed by Engineer-in-charge. Cat Part No CSDBSPNSD08 of C&S, or equivalent in Havells/Legrand
Supply & Fixing Sheet metal enclosure for DB,s, double door (when MCB,s to be used) single pole & neutral 4 way with 200 amps rated bus bar 240 volts with fixing arrangements including taking down ICDP/DB's any type including taking down of kitkat fuse/MCB SPN/SP as directed by Engineer-in-charge. Cat Part No CSDBSPNSD08 of C&S, or equivalent in Havells/Legrand
Supply and fixing MCB Triple pole and nuetral 63 Amps, 415 volts complete all as spd and directed. Make C&S, Havells, Legrand, L&T
Supply and fixing MCB single pole and nuetral 6 to 40 Amps, 240 volts complete all as spd and directed. Make C&S, Havells, Legrand, L&T
Supply and fixing MCB single pole 6 to 32Amps, 240 volts all as spd and directed. Make C&S, Havells, Legrand, L&T
M&L GI pipe light grade 40 mm dia for cable protection laid in trench , under road /over roof or under floor wall using bend/tee including fixing to wall/roof by using clamp/nut bolts etc complete all as directed by Engr-in charge.
M & L for sub main wiring with 4.0 sqmm copper conductor cable multistrand, FRPVC sheathed two run (as phase and neutral) and run 4.0 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in drawn in one pvc concealed wiring complete all as specified and directed by Engr-in-charge.(Note:-the rate for concealed type point wiring shall deemed to include the cost of cutting,chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plasterand matching the surface by white wash/colour wash all as per existing finishes complete).
Supplying, fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts /on wall surface as in repairs/replacement of old unserviceable cable of following sizes all as specified and directed. (a) 4 core 16 Sqmm
M&L for sand cushioning for cable protection 8 cm below the cable and 15 cm above the cable complete all as specified and directed
Supply and lay burnt bricks sub class `B’ of size 230x115x75mm laid dry over sand cushioning in trenches as protection on the cable all as directed
Excavation in trenches in any type of soil n. exc 1.5mtr wide and n. exc 1.5mtr depth for GI tubing and getting out in Hard/dense soil all as specified.
M&L for returning, filling in including sperading, leveling watering and well ramming in layers n. exc 25 cm thick each layers in soil all as specified and directed.
M&L for removal of surplus soil to a distance not exceeding 50 mtr and deposting where directed and at a level not exceeding 1.5 mtr above the starting point all as specified and directed by Engr-in-Charge.
Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground any type of soil including rock soil alos (earth pit not less than 2.25 Mtr below ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts, as earth lead complete including 40mm bore dia protection pipe GI medium grade upto 7.5 mtr length, watering pipe 15mm bore dia GI medium grade 1.70m length, charcoal & salt filling, necessary earth work in any type of soil including rocky soil also, concrete pit, funnel removal of surplus soil upto 50m distance all as per electrical plate No.3 of SSR Part-I and connected to earthing test point, main board including testing on completion all as specified and as directed by Engr-in-charge.
S&F in Test point terminal block made of gun metal or phosphorus bronze size 75x75x5mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. head screw complete all as specified and directed by Engr-in-Charge.
S & F in replacement aluminium strip of size 25 x 3.15 mm fixed with porcelain/PVC saddles and fixing screws etc minimum tow number saddles with screws on and including PVC guttis in each one mtr of length for roof conductors and down conductor above ground complete all as specified and directed
S&F in replacement of air termination single pointed aluminium rod 12 mm dia and 300 mm long and fixed including taking out old ari termination rod complete all as specified and directed.
Pathania Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .