| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.5 Cr | L1 | Accepted-Finance Lowest One |
| 2 | L2₹1.5 Cr+₹2.7 L (1.80%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹1.5 Cr+₹2.7 L (1.80%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹1.8 Cr+₹28.4 L (19.0%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹1.8 Cr+₹28.4 L (19.0%) | L3 | Rejected-Finance Other than lowest |
| 4 | Rejected-Technical BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | - | - | Rejected-Technical Due to not enlisted in appropriate category |
| 5 | Rejected-Technical 5D 95 VRINDAVAN YOJNA RAEBARELI ROAD LUCKNOW UP 226 029 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226029 | - | - | Rejected-Technical Due to not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
7 Jun 2023, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIR MAINT OF LIGHTENING ARRESTERS EARTHING PITS AND REPAIR MAINT SUBMAIN WIRING COMMON AREA AND REPAIR ROUTINE MAINT OF COLLING APLLIANCES AND CONNECTED WORKS UNDER GE NW NOFRA COLABA MUMBAI
2023_MES_595083_1
8176
Open Tender
Civil Works
Item Rate
330 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
Yes
GE NW NOFRA
₹2.2 L
Yes
17 Oct 2023
12 May 2023
9 Jun 2023
12 May 2023
7 Jun 2023
31 May 2023
12 May 2023 - 25 May 2023
Amount
Material and labour for Detecting the gas leakage, rectifying the defects by vacumizing and charging fresh mafron gas and commissioning and testing the window type air conditioner unit 1.5 Ton capacity complete all as specified and directed.
All as per item No 1.00 above but of 2.0 Ton capacity
All as per item No 1.00 above but of Split type AC 1.5 Ton Capacity.
All as per item No 1.00 above but of Split type AC 2.0 Ton Capacity.
All as per item No 1.00 above but of Water cooler 40/60/80/120/150 Ltrs. Capacity.
All as per item No 1.00 above but of Refrigerator 100/165/180/230/260/31/350 Ltrs. Capacity.
All as per item No 1.00 above but of Deep Freezer of 260/280/310/350/500 Ltrs. Capacity.
Material and labour for taking out window type Air conditioner 1.0/1.5/2.0Ton capacity of any make from its original location, removing the dust from body with blower, cleaning the condenser and cooling coil by using water and caustic soda, painting the base tray with one coat of black enamel paint checking all the connections including functioning of metal clad socket/ DP switch function of relay capacitors overload protector thermostat fan motor blade fan blower drum etc. oiling/ greasing of fan motor checking serviceability and refixing it in its original place including testing commissioning for 1.0/1.5/2.0 Ton of AC of any make all as specified & directed by Engineer-in-Charge. Note: (i) Periodicity of Servicing is Three Times in a Year.
All as per item No 8.00 above but of split type AC 1.5/2.0 Ton capacity complete out door and indoor. Note for item Nos 8 & 9 :Refrigerant gas will be measured & paid separately . Note: (i) Periodicity of Servicing is Three Times in a Year.
Cutting out existing wall / window grills / existing window frame for making suitable space to accommodate window type AC making frame with 2nd class hard wood piece of min of 50 x 50 mm size & up to 60 cm height for fixing of outer cover of AC & supporting structure made out 40 mm x 40 mm x 5 mm thick MS angle iron duly grouted in wall & closing the open space around ACs with the help of 6 mm thick ply wood exterior grade to close air leakage tightening with woolen felt (green felt) and painting to wooden structure matching to interiors as directed & steel structure with one coat of primer and two coats of synthetic black enamelled paint and fixing only window type AC all as directed by Engineer-in-Charge including complete connecting and testing all as specified and directed by Engineer-in-Charge.
All as per item No 10.00 above but shifting of AC from existing location to new location including making good of old location all as specified and directed by Engineer-in-Charge.
Material and labour for taking down Corroded body base tray etc of window type air conditioners and replacement of body base tray etc out of 18 SWG and other portion with MS sheet 20 SWG including motor mounting frame nuts and bolts suitable size painting and necessary insulation complete for 1.0 / 1.5 / 2.0 Ton capacity Air conditioner. (Note : For dismantling compressor for body work and reassembling and gas charging (Gas to be measured seperately) as per site requirement shall be inclusive in quoted rate)
Material and labour for preparation of old painted surfaces of Refrigerator any capacity by complete scraping old painting an applying two coats of synthetic enamel paint on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
Material and labour for preparation of old painted surfaces of Water cooler any capacity by complete scraping old painting an applying two coats of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
Supply, install, test & commissioning new compressor sealed reciprocating type suitable for window type AC 1.5 Ton capacity duly charged with fresh Refrigerant gas etc. complete all as specified & directed by Engineer-in-Charge. Make : Voltas/usha Shriram / Bluestar / Samsung / Hitachi / Videocon/LG/Carrier etc. as per existing make at site.
All as per item No 15.00 above but of 2.0 Ton capacity
All as per item No 15.00 above but of Split type AC 1.5 ton capacity
All as per item No 15.00 above but of Split type AC 2.0 ton capacity
All as per item No 15.00 above but of Refrigerator 100/165/180/210/230/260/310/350 Liters Capacity.
All as per item No 15.00 above but of Water coolers 40 / 60 /80/120/150 Liters capacity
All as per item No 15.00 above but of deep freezers of capacity 310ltrs/410Ltrs/500 ltrs Capacity
Taking down carefully split type AC of capacity 1.5 / 2.0 ton & refixing on new location complete with pre fabricated brackets/ frame work as required complete & making the good existing surface with out any damage out & indoor unit complete.
Removing the existing unserviceable burnt fan motor from window/ split type AC of capacity 1.0 / 1.5 / 2.0 Ton and replacing the same with brand new fan motor of same capacity including connecting up and testing complete.
Supply and fix fan motor suitable for water cooler of any capacity including removing old fan motor and testing complete.
Supply,fixing and testing fan blade suitable for window/split type Air conditioner of 1.0 / 1.5 / 2.0 Ton capacity including removing old fan blade.
Supply, fixing and testing fan blade suitable for water cooler of any capacity including removing old fan blade.
Replacing old defective blower drum and supply & fix blower drum suitable for window type Air conditioner of 1.0 Ton / 1.5 Ton / 2.0 Ton capacity.
Replacement of front cover grill suitable for window type AC 1.0 Ton / 1.5 Ton / 2.0 Ton capacity AC of various makes.
Replacement of starting capacitor 60 - 80 mfd.Make:(ANAND/UNIQUE/ KELTRON)
Replacement of starting capacitor 80-100 mfd. Make:(ANAND/UNIQUE/ KELTRON)
Replacement of running capacitor 25 MFD (Make : Asian / Epcos)
Replacement of running capacitor 36 MFD (Make : Asian / Epcos)
All as per item No 33.00 above but rotary type
Supply and fix in replacement of thermostat switch for window type AC of capacity 1.0 Ton / 1.5 Ton / 2.0 Ton capacity (Make :- Indofoss / Ranutral)
Supply and fix in replacement of thermostat switch for split type AC of capacity 1.5 Ton / 2.0 Ton capacity (Make :- Indofoss / Ranutral)
Supply and fix in replacement of thermostat switch for Refrigerator of any capacity (Make :- Indofoss / Ranutral)
Replacement of thermostat switch for Water Cooler of any capacity (Make :- Indofoss / Ranutral)
Taking out old unserviceable and Supply & Fix new over load relay suitable for Window/Split type AC of 1.0 Ton / 1.5 Ton / 2 Ton capacity all as directed.(Make : Arvind / Usha / Rametrol)
Taking out old unserviceable and Supply & Fix new over load relay suitable for water cooler of any capacity all as directed(Make : Arvind / Usha / Rametrol)
Taking out old unserviceable and Supply & Fix new over load relay suitable for Refrigerator of any capacity all as directed(Make : Arvind / Usha / Rametrol)
Supply and fix of Float valve suitable for Water cooler of any capacity
Supply fixing and clamping jointing copper tubing for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete.
Supply and lay cable PVC insulated 3 core 4 Sq mm with copper conductor cable suitable for indoor unit to outdoor unit complete all as directed by Engineer-in-Charge
Supply and lay Flexible PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe etc match the existing surface complete.
Supply and fix push cock / lifting cock of 15 mm bore in repair for water cooler of any capacity
Supply and fix GI water tray 2 mm thick for window type AC any capacity with out let system connection provided with PVC pipe of 20 mm dia up to 3 meter length connecting to drain pipe.
Supply and fix PVC drain pipe with necessary saddles of 25 mm size to be used as out let drain to be fixed all as per direction of Engineer-in-Charge
Supply and fix sheet metal enclosure with 2 pin and earth plug and socket complete with single pole MCB of 20 Amps all as specified & directed by Engineer-in-Charge.
Taking out old unserviceable and Supply & Fix new magnetic gasket for refrigerator of 165 / 286 / 310 liters complete all as directed by Engineer-in-Charge.
Taking out old unserviceable condenser coil of 1.5 Ton window type AC any make with sins cutting in let outlet connecting copper pipe and providing new condensor coil with sins and connecting inlet outlet copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 51.00 above but for 2.0 ton window type AC complete all as specified and directed by Engineer-in-Charge.
All as per item No 51.00 above but for 1.5 ton Split type AC complete all as specified and directed by Engineer-in-Charge.
All as per item No 51.00 above but for 2.0 ton Split type AC complete all as specified and directed by Engineer-in-Charge.
Removing electronic unserviceable circuit boards from window type AC 1.5 ton / 2.0 Ton capacity and replacing with new circuit boards and connecting with system with replacing remote control hand set and testing complete all as specified and directed
All as per item No 55.00 above but for 1.5 Ton / 2.0 Ton Split type AC complete all as specified and directed
Supply and fix blower fan motor capacitor 4 MFD (Make : Asian / Keil)
Supply and fix blower fan motor capacitor 6 MFD (Make : Asian / Keil)
Supply and fix of electric bulb suitable for refrigerator of any capacity screw type / pin type (Make :- Philips / Equivalent)
Supply and fix of Air filter for window type AC of any capacity and type by Engineer-in-Charge.
Material and labour for replacement of damaged outer cover for window type Air conditioner of any capacity and size made out of aluminium sheet of 20SWG all as specified by Engineer-in-Charge.
Taking out existing unserviceable over load protector and Supply & Fix new over load protector for 1.0 /1.5 /2.0 Ton capacity window type Air Conditioner (Make : Usha/ Ranutral).
Supply of sensor remote handset suitable for 1.5/2.0 Ton capacity split/window type AC etc. complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement multipurpose door lock with duplicate key of refrigerator of any make & capacity etc complete all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable cooling coil of window/split type AC any capacity and any make with sins cutting inlet outlet connecting copper pipe and providing new cooling coil with sins and connecting inlet outlet copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix Condensing unit bracket stand of any size and type suitable for supporting to out door unit of split type AC including nut, bolts & washers etc complete all as specified and directed by Engineer-in-Charge.
Repair/replacement of indoor unit of split type AC 1.5 TR cap having 3 star rating complete with all accessories such as installation plate with screws, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed. (Note :- Old unserviceable indoor unit will be deposited to MES store)
Repair/replacement of outdoor unit of split type AC 1.5 TR cap having 3 star rating complete with all accessories such as hermetically sealed compressor, condenser unit, capacitor, relays, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed. ( Note :- Old unserviceable outdoor unit will be deposited to MES store)
Supply & fix in repairs UPVC Pipes of size 15 mm dia with all fittings and fixed complete to walls and ceilings or laying in floors complete all as specified and as directed.
Supply & fix in repairs UPVC Pipes of size 20 mm dia with all fittings and fixed complete to walls and ceilings or laying in floors complete all as specified and as directed.
Supply & fix in repairs UPVC Pipes of size 25 mm dia with all fittings and fixed complete to walls and ceilings or laying in floors complete all as specified and as directed.
Supply and fix in repairs nitrile rubber super lone insulation of 20 mm thickness with proper adhesive for sticking properly on UPVC tubes of size 15 mm bore with out any air gap on pipe surfaces and joints for avoid heat loss complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs nitrile rubber super lone insulation of 20 mm thickness with proper adhesive for sticking properly on UPVC tubes of size 20 mm bore with out any air gap on pipe surfaces and joints for avoid heat loss complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs nitrile rubber super lone insulation of 20 mm thickness with proper adhesive for sticking properly on UPVC tubes of size 25 mm bore with out any air gap on pipe surfaces and joints for avoid heat loss complete all as specified and directed by Engineer-in-Charge.
Supply and fix concussive push button taps of size 15 mm of cast copper alloy suitable for to connect with UPVC pipe complete all as specified and as directed.
Supply and fix ball valves of high pressure PTMT with epoxy coated high density plastic of sizes15 mm bore complete all as specified and as directed.
Supply and fix ball valves of high pressure PTMT with epoxy coated high density plastic of sizes 32 mm bore complete all as specified and as directed.
Maintenance, repair and servicing/cleaning of kitchen hood blower of10000 CFM 440V V-belt drive for fresh air and exhaust air at INS Shikra Sailors Galley /DSC mess/ WNC (O) Mess complete all as specified and as directed.
Maintenance, repair and servicing/cleaning of kitchen hood V shape with side oil filter matt finish and fresh air, aluminium grill with damper with GI 20 frame and 24 flap oil filter with oil drain complete all as specified and as directed. Hood size - 7500 x 3150 x 600mm (Height) Oil filter size 500 x 500 (Height) x 50 = As per Qty existing at site.
Material & labour for Rewinding of unserviceable Blower motor of 7.5 HP capacity 3 phase 50 Hz 415volt complete comprises as under :- (a) Disconnecting & removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation. (c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8 hours continuously to check the RPM etc. to the satisfactory performance etc. complete. Loc : WNC (O) Mess / INS Shikra Sailors Galley /DSC mess NOTE: Any damage caused during handling will be made good by contractor without any extra cost to department
All as per item No 80 above but motor capacity 1 HP for centralised water cooler complete all as specified and directed Loction WNC (O) Mess/ INS Shikra/ Pasta Lane.
Servicing/ repairs/ maintenance including replacement of minor spare parts of Centralised water cooler system of capacity 1000 Ltrs. installed at WNC(O)Mess/ Pasta Line complete all as specified and directed by Engineer-in-Charge.
Servicing/ repairs/ maintenance including replacement of filters, flexible pipes of any water purifier system complete to match the existing and connecting up with existing system complete all as specified and directed by Engineer-in-Charge.
Removing electronic unserviceable PCB from water purifier system and replacing with new circuit boards and connecting with system and testing complete all as specified and directed by Engineer-in-Charge.
Supply & charging refrigerant R-22 Gas as per requirement complete all as specified and as directed .Make:mafron or as approved by GE
Supply & charging refrigerant R-134 Gas as per requirement complete all as specified and as directed. .Make:mafron or as approved by GE
Supply & charging refrigerant R-32 Gas as per requirement complete all as specified and as directed. .Make:mafron or as approved by GE
Supply and fix in replacement Contactor of split type AC any capacity complete all as specified and directed.
Supply and fix in replacement sunction & liquide line valve of size (5/8"&1/4")/(5/8"&3/8") suitable for split type AC complete all as specified and directed.
Supply, errect & fabricated rectangular square duct made out of 2/22 SWG GI sheet in L shaped hollow profile including all accessories such as corner, carriage bolt hangers, gasket and seal the longitudinal joints with and including approved sealant complete all as specified and directed.
Taking down old unserviceable insulation from any surface and supply and fix nitrile rubber insulation of one layer of 19mm thickness sticking on surface by using approved adhesive and sealing the joints by weather proof tape complete all as specified and directed.
Supply and fix of plug top 15 Amps,3 pin for water cooler/Acs of any capacity and any make as per site requirement complete all as directed
Suuply and fix in repairs leather type canvas in hood duct of any size as per existing at site complete all as specified and directed
Repair/eplacement of indoor unit of split type AC 2.0TR capacity having 3 star rating complete with all accessories such as installation plate with screw, blower motor, swing notor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc all as specified and directed. (Note :- Old indoor unit will be deposied to MES (E/M) Store yard. Make :- Voltas/ LG/Bluestar
Repair/replacement of outdoor unit of split type AC 2.0 TR cap having 3 star rating complete with all accessories such as hermetically sealed compressor, condenser unit,capacitor, relay, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connection,etc complete all as specified and directed. (Note :- Old Outdoor unit will be deposied to MES (E/M) Store yard Make:- Voltas/ LG/Bluestar
Repair/replacement of Window type AC 1.5 TR cap having 3 star rating complete with all accessories such as hermetically sealed compressor, condenser unit,capacitor, relay, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connection,etc complete all as specified and directed. (Note :- Old window AC will be deposied to MES (E/M) Store yard Make:- Voltas/ LG/Bluestar
Repair/ replacement of High velocity commercial air curtain unit for prevention of dust and conditioned air losses single phase 220 Volt 50 Hz made of MS / CRCA sheet of min thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (over baked) with MS based CRC 18 gauge sq perforated suction grills aluminum alloy fans and single phase electric motor nozzle etc with fittings and accessories so as to produce 1-1.5 M / Sec air velocity at floor level for for door opening 28" x 78"complete all as specified and directed .Make:Technocraft or equivalent as approved
M&L for Cleaning of Air handling ducts / Kitchen hood duct internally by using special T&P like robortic arm, air compressor, air jet nozzles, flipper, vaccum pump and a suction blower with hepa filter and check before and after the cleaning complete all as specified and directed
Material and labour for framed work with structural steel sections including nuts, bolts,washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as directed including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
Repair/replacement of industrial water purifier system/ industrial aquaguard system complete with all accessories such as carban filter/cartage filter, filter kit, solenoid valve, pump, switch of machine,circuit board including all electrical parts etc duly prewired including reconnecting of existing piping, electrical connection,etc complete all as specified and directed.
Suuply and fix in repairs volume control damper made out of galvanized iron or anodized aluminium with overlapping leafs to avoid any leakage from the damper as per existing at site complete all as specified and directed
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces.
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing caping not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix in repair submain wiring two single core 6 Sqmm for sub main witing with copper conductor multistranded PVC insulated and unsheathed 1100Volts grade in and including PVC casing capping / conduit not less than 25mm dia with fixing accessories including one run of 6.0 Sqmm copper conductor. Note :- (i) Two runs of 06 Sqmm cable, one run of 6.0 Sqmm earth cable and one run of PVC casing Capping /conduit shall be measured as one running meter. (ii) Each submain wiring shall run in seperate PVC casing caping/conduit Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix submain wiring in repair 2 single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC conduit not less than 25mm dia including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing. Note :- (i) Two runs of 10 Sqmm cable, 1 run of PVC casing caping/ conduit and 1 run of 10 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping / conduit Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-54, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :- Make - Legrand/ Schneider/ GE
(a) Isolator SPN 63 Amps, 240 Volts - 01 No Make - Legrand/ Schneider/ GE
(b) MCB SP 6-32 Amps, 240 Volts. Make - Legrand/ Schneider/ GE
Supply and fix in repair MCB, DB, SPN 8 way double door with protection type IP-54 with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed, as approved comprising following :- Make - Legrand/ Schneider/ GE
Isolator SPN 40 Amps 240 Volts-01 No (C Series). Make - Legrand/ Schneider/ GE
Supply and fix in repair single phase sheet metal powder coated double door distribution board 4 way comprising with following :- (a) MCB SPN 40Amps 240Volts, 10KA - 1 No ('C' Series) (b) MCB SP 6 - 32Amps 240Volts - 2No ('C' Series) Make - Legrand/ Schneider/ GE
Supply and fix in repairs sheet metal enclosure 2 way without bus bar with MCB comprising following Make - Legrand/ Schneider/ GE
Isolator DP 63 Amps Breaking capacity 10 KA. (C series) . Make - Legrand/ Schneider/ GE
Supply & fix in repair MCB DB, TPN 8 way vertical type, 415 V with 200 Amps rated bus bar and double door connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed, comprising of the following : - (a) MCCB 3 Pole, 415 V fixed type, 160 Amps with breaking capacity 25 KA-01 Nos (incoming) MAKE: Legrand, Schneider, GE (b) MCB TP 63 Amps, 10KA - 06 Nos (C Series) (Outgoing) MAKE: Legrand, Schneider, GE (c) MCB SP 40 Amps, 10KA - 06 Nos (C Series) (Outgoing) MAKE: Legrand, Schneider, GE
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified.
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with metallic ISI marked terminal boxes/ modular Cover plate concealed in wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :- Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
(f) One bell point controlled by one bell push 5 Amps.
Material and Labour for point wiring complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with metallic ISI marked terminal boxes / modular Cover plate concealed in wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 2.5 sqmm as earth continuity conductor connected to common earth as earth dolly. Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix in repair Modular Switch, 6Amp, One way, 1 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular blank plate, One way, 1 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular Switch, 16Amp, One way, 1 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular type bell push , 6Amp, 1 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Bell electric AC 230Volt single pole musical type with ISI mark. Make - Legrand /Gold Medal / Anchor
Supply and fix in repair Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair ceiling rose surface PVC/polycarbonate, isolated body with ISI mark, flush type with ISI mark three terminals complete all as specified. Make - Legrand /Gold Medal / Anchor
Supply and fix in repair Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
M & L required for filling wall cavity & cutting chases in cement mortar 1:3 not exc 10 cm in girth to ends or edges including taking down existing metal or wooden sinking box & making good to wall surface for concealed modular metal flush box or concealed conduit wiring, etc
Supply and fix in repair Modular white cover plate with Frame 1 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 2 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 3 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 4 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 6 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 8 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 12 Module. Make- Legrand (Aretor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 1 module.
Supply and fix in repair Modular metal flush box 2 module.
Supply and fix in repair Modular metal flush box 3 module.
Supply and fix in repair Modular metal flush box 4 module.
Supply and fix in repair Modular metal flush box 6 module.
Supply and fix in repair Modular metal flush box 8 module.
Supply and fix in repair Modular metal flush box 12 module.
Supply and fix in repair Linear Aluminium Baten LED T/L 20W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make- Philips / Havells/ Jaquar or equivalent
Supply and fix in repair Linear Aluminium Baten LED T/L 10W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make- Philips / Havells/ Jaquar or equivalent
Supply and fix in repair LED lamp suitable for 7 to 9 watts, 240 volts, single phase, 50 Hzs, Lumen 1450 AC supply. Make- Philips / Havells/ Jaquar or equivalent
Supply and fix in repair LED lamp suitable for 12 watts, 240 volts, single phase, 50 Hzs, Lumen 1450 AC supply. Make- Philips / Havells/ Jaquar or equivalent
Supply and fix in repair LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hzs, Lumen 1450 AC supply. Make- Philips / Havells/ Jaquar or equivalent
Material and Labour in repair for Lamp holder, PVC /Polycarbonate type with cord grip cap suitable for pendant fittings complete all as directed by Engineer-in-Charge. Make- Anchor / Havells/ Legrand
Supply and fix in repair Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners. Make - Legrand/ Schneider/ GE
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH all as specified and directed by Engr - in - Charge.
S & F 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade for repair of any single wire in exisitng casing capping/ conduit (Point Wiring) for any of colour coding (i.e Red, Green, Blue) all as specified and directed by Engr - in - Charge.
S & F 4.0 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade for repair of any single wire in exisitng casing capping/ conduit for any of colour coding (i.e Red, Green, Blue) all as specified and directed by Engr - in - Charge.
S & F 6.0 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade for repair of any single wire in exisitng casing capping/ conduit for any of colour coding (i.e Red, Green, Blue) all as specified and directed by Engr - in - Charge.
S & F 10.0 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade for repair of any single wire in exisitng casing capping/ conduit for any of colour coding (i.e Red, Green, Blue) all as specified and directed by Engr - in - Charge.
M & L for in reapir excavation of old existing earthing including removal of old earthing plates, erthing materials, earthing strips etc and returning filling the same after replacement of earthing plate, earthing materials like coke, salt etc all as specified and directed by Engr - in - Charge. Note: (i) All the earthing materials like earthing plates, earthing strips, coke, salt etc will be measured and paid seperately under relevant items.
M & L for replacement of in repair earthing plate of suitable size with connections of existing earth strips, funnel etc for better results in existing earthing all as specified and directed by Engr - in - Charge.
M & L for replacement of in repair refilling of earthing materials coke, salt in sufficient qty at par the satisfaction of Engr - in- Charge for better results in existing earthing all as specified and directed by Engr - in - Charge.
M & L for in repair PCC chamber (1:3:6) type C-1 and 40 mm thick all as specified and directed by Engr - in - Charge.
M & L for in repair RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as specified and directed by Engr - in - Charge.
M&L in repair/ Replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 32 x 6 mm
M&L in repair/ Replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm
S & F in repair test points terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3nos 8mm dia 25mm long hexagonal head screw building lightning earth test point complete all as specified and directed.
Material and Labour for laying of in repair old alluminium earthing strips all as specified and direcetd.
M&L in repair/ Replacement of Air termination, single pointed aluminium rod 12mm dia and 300mm long
M&L in repair/ Replacement of earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI strips 32 x 6 mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 5 of SSR Part-I all as specified and directed.
M&L in repair/ Replacement of earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised earth lead wire 4.0mm dia by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 5 of SSR Part-I all as specified and directed.
Materal and labour for in repair CPT Cirprotec CPT-L ESE Lighting rod with stainles steel body type advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on principle of early streamer emission technology which will offer level 1 protection for upto 42 mtrs radius when mounted on the RCC concrete base on building at a height of 4.5 mtrs from the place to protected complete all as specified and directed.. Make:- NIMBUS-JEF Techno or U Portec or Erico as approved by GE
Supply and erection of in repair mounting structure of 4.5 mtrs height with base plate suitable for roof mounting on RCC concrete base on building complete all as specified and directed.. Make:- NIMBUS-JEF Techno or U Portec or Erico as approved by GE
Supply and fixing of in repair 1x 50 sqmm copper conductor with 0.5 mm thick PVC sheathed cable complete all as specified and directed.
Supply and fixing in repair 4 digital electromechanical lightning event counter in weather proof resistance complete all as specified and directed. Make:- NIMBUS-JEF Techno or U Portec or Erico as approved by GE
Supply and fixing of in repair test link for connecting the earth pit and down conductor complete all as specified and directed.. Make:- NIMBUS-JEF Techno or U Portec or Erico as approved by GE
Material & labour for in repair maintanance free enviroment friendly earth elctrode set comprising of 17.2mm dia, 3m long rod low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANS/INSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 Ibs) complete all as specified and directed.. Make:- NIMBUS-JEF Techno or U Portec or Erico as approved by GE
Material and labour for in repair PCC pit 1:2:4 type B-1, cover reinforced with XPM, weight not less than4kg/sqm and 6mm dia bar handle earth pit angle iron frame of size 25x25x3mm complete all as specified and directed.
Supply and fix in repair/ replacement of GI pipe light grade 20mm dia for support to copper cable down conductor complete through wall/ ceiling/ truss/ duct etc including fixing with clamp, nuts, bolts complete all as specified and directed.
Supply and fix in repair/ replacement of GI pipe light grade 40mm dia for support to air termination rod including fixing with clamp, nuts, bolts complete all as specified and directed.
Road/PCC cutting neccesary for laying of 40mm GI pipe for cable protection and making good complete all as specified and directed.
Supply of PVC DLP - On wall trunking with all finishing accessories (end, joint of lid, joint of body,interior angle, exterior angle, flat angle, derivation) confirming standard EN 50085-2-1.Trunking should accept Wiring device with all the functions by associating the accessory of installation.Trunking should confirm to the current specifications of NF C 68-104 in terms of both performance and level of functions provided by the system. Installation trunking (which carries electrical wiring accessories) should be type 3 (installation)in the new standard.Material should be Non-flame propagating. Degrees of protection provided by enclosure should be IP 40. Protection against mechanical impact should be IK 07. Trunking should be delivered in length of 2m. The trunking covers and partitions should be in PVC white RAL 9003.The accessories should be in plastic ABS white RAL as per following details:- Make - Legrand.
S & F in replacement of PLASTIC TRUNKING 105MMX50MM with 2 Compartment with following acessories complete all as specified and directed by Engineer - in - Charge.
(i) FLEXIBLE COVER 40MM WIDTH - 2 covers
(ii) CLIP ON PARTITIONS
(iii) BASE JOINT
(iv) JOINT FOR 40MM WIDTH COVER
(v) INTERNAL ANGLES-ADJ FRM 80 DEG
(vi) EXTERNAL ANGLES-ADJ FRM 60 DEG
(vii) FLAT ANGLES
(viii) END CAP
S & F in replacement of PLASTIC TRUNKING 195MMX50MM with 2 Compartment with following acessories complete all as specified and directed by Engineer - in - Charge.
(i) FLEXIBLE COVER 85MM WIDTH
(ii) CLIP ON PARTITIONS
(iii) BASE JOINT
(iv) JOINT FOR 85MM WIDTH COVER
(v) INTERNAL ANGLES-ADJ FRM 80 DEG
(vi) EXTERNAL ANGLES-ADJ FRM 60 DEG
(vii) FLAT ANGLE FOR 195X50-DLP TRU
(viii) END CAPS
cooltech engineering services
Darpan Construction
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .