| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹33.5 L+₹8.8 L (35.4%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
20 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
REPAIR MAINT AND IMPROVEMENT TO LT ELECTRICAL DISTRIBUTION SYSTEM INCLUDING STREET LIGHT GARDEN LIGHTS FLOOD LIGHTS AND ALLIED WORKS UNDER GE (EAST) MATHURA
2022_MES_564829_1
8200-1307/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE EAST MATHURA
₹1 L
16 Jan 2023
23 Nov 2022
22 Dec 2022
23 Nov 2022
20 Dec 2022
8 Dec 2022
23 Nov 2022 - 13 Dec 2022
Amount
Dismantling of old unserviceble Aluminium conductor off sizes from existing over head lines complete all as specified and as directed.
All as per item serial No 1.00 here-in-before but GI wire for copper conductor survice feeder or distributor span complete all as specified and as directed.
Dismantling/taking down old unserviceable pin/loop/shackle type insulators any type, size complete all as specified and as directed.
Dismantling old cross arms of MS channel or angle section and anti climbing devices of any sizes from pole/structures complete all as specified and as directed.
M&L for ACSR conductor any sizes drawn over for over head lines fixed to insulators with binding wire after allowing specified sag complete all as specified and as directed.
M&L for GI wire 4mm dia as continuous earth wire, guarding and craddles to OH line including binding wire complete all as specified and as directed.
Supply & fixing pin type porcelain vitreous white or brown or green insulators 100 mm height and 65 mm dia for 1100 Volts grade including one galvanised mild steel spindle, two galvanised iron washers and one nut complete all as specified and as directed.
Supply and fixing shackle type porcelain vitreous, white, brown or green insulators of size 75 mm height and 90 mm dia including galvanised MS straps 31x3 mm size with 12mm dia bolt, nut and washers for working pressure 1100 Volts grade complete all as specified and as directed.
M&L for loop insulator, vitreous, porcelain, white, brown or green, large size with overall dimensions 90x140mm clearance of hole 25.5 mm complete all as specified and as directed.
M&L MS cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel confirming to Fe-410-O or 310-Oincluding nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size including applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
M&L for scraping, scretching, cleaning the old paint, preparation of the surface for repainting and pinting LT 09 Mtr long steel tubular pole with two coats of aluminium paint and writing pole Nos. including snowsem on PCC muff complete all as specified and as directed.
M&L for scraping, scretching, cleaning the old paint from 9mtr long PCC pole. Preparation of the surface for repainting and painting in Black & White strip 30 cm wide alternaterly up to 1.5 mtr height from ground level with synthetic enmel paint, writing pole Nos and applying one coat of cement base paint on PCC muff & on remaining portion of the pole complete all as specified and as directed.
M&L for dismantaling of old/unserviceable PCC poles/struts any type and size complete all as specified and as directed.
Supply and erecting steel tubular swaged pole with swan nacked complete with cast iron base plate, finial taper plug, bolts, nuts & washers made out of mild steel tubing, type 410 SP -31 (9 Mtr long) including marking pole No on pole and painting to pole by applying two coat of aluminium paint over a coat of red oxide primer (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and as directed. Note : Earth work and PCC in foundation shall be measured separately.
M&L for stay assembly complete with MS stay plate 300x300x6mm thick galvanized stay rod 20mm dia, 2.15 M long galvanized stay bow, galvanized thimble, stay clamp etc complete as shown in electrical plate No1of SSR part-I complete all as specified and as directed. Note : Excavation, earthwork, cement concrete loop type insulators and stay wire shall be included in the quoted rates.
M&L Galvanised stay strand, size 7/4mm complete all as specified and as directed.
Stringing of existing overhead LT line ACSR conductor of any size opening /dismenting of jumpers and ACSR conductors from insulators and connecting after stringing inclusing required ACSR conductore/connectors of following span of conductors :-
Span of two/three ACSR conductors of any size complete all as specified and as directed.
Span of four /five ACSR consutors of any size complete all as specified and as directed.
Cutting wild grass, bushes, creaper, unwanted vegetation from inside/surrounding of E/M installations, near transformers, pole structures etc including cutting creapers from barbed/cattle fencing of the installations as and when directed and removing of unwanted material from installation compound and depositing where directed. Note : The item shall be operated maximum three times in entire period of contract in the same installations. (Area measured separately each time).
Labour & tools for trimming tree branches upto 100 mm girth of any location around existing HT/LT OH lines giving clearance of 1.5 m on all sides complete. Note : Trimming of tree branches irrespective in numbers in each tree shall be measured as one unit.
Supply, installing, commissioning and testing LT panel board outdoor type in repalecement of rusted/corroded LT Panel,cubicle type made out CRCA sheet 3.15 mm thick and inner sheet 2.0 mm thick, dust and vermin proof and angle iron of suitable size, pedestal flame grouted in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregated) thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with 1000 Amp rated aluminum bus bar of of suitable size,(in separate chamber) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB 630 Amp 36 KA , 4 pole, Ics=100%Icu -01 Each (in coming) (a) MCCB 250 Amp 25 KA , 4 pole -02 Each (b) MCCB 160 Amp 16 KA , 4 pole -03 Each (b) MCCB 100 Amp 16 KA , 4 pole -01 Each (b) MCCB 63 Amp 16 KA , 4 pole -01 Each (c) Digital Amp meter (0-250)-01 Each (d) Digital Volt meter (0-500) -01 Each (e) RYB Indicator-01 Set Note : Drawing of panel shall be got approved from GE before procurement
Supply, installing, commissioning and testing LT panel board outdoor type in repalecement of rusted/corroded LT Panel, cubicle type made out CRCA sheet 3.15 mm thick and inner sheet 2.0 mm thick, dust and vermin proof and angle iron of suitable size, pedestal flame grouted in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregated) thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with 600 Amp rated aluminum bus bar of of suitable size,(in separate chamber) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB 400 Amp 36 KA , 4 pole ,Ics=100%Icu -01 Each (in coming) (b) MCCB 200 Amp 25 KA , 4 pole -01 Each (c) MCCB 160 Amp 16 KA , 4 pole, -02 Each (d) MCCB 100 Amp 16 KA , 4 pole, -01 Each (e) MCB 32 Amp 10 KA , 4 pole, -01 Each (f) Digital Amp meter (0-250)-01 Each (g) Digital Volt meter (0-500) -01 Each (h) RYB Indicator-01 Set Note : Drawing of panel shall be got approved from GE before procurement
Taking down unserviceable LED street/ security/flood light fittings of any type/wattage/make etc fitted on LT poles, High Mast light poles, building etc for repairing including complete dismantling, checking for repair/replacement of unserviceable parts as required and making the LED light fittings operational to give rated illumination by replacing unserviceable spare parts and refixing the same at existing location or any other location as directed at site and making electrical connections with existing wire complete all as directed. Notes : (i) Cost of taking down carefully from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard (If required for repair), is deemed to be included in quoted rate of this item. (ii) Cost of supply and fixing of major items required to make the lights serviceable shall be measured and paid separately under item No 27.01 to 27.04 of this schedule. (iii). Cost of items or works not mentioned under item 27.01 to 27.04 and however required to make the lights serviceable will be provided by the contractor without any extra cost to the department and cost thereof shall deemed to be included in the rate quoted against this item. (iii) All T&P used for lowering/raising of High Mast lights/fittings etc shall be included in quoted rate.
Supply only following items to be incorporated against item No 26.00 here in before.
Electronic LED driver suitable for LED street light fitting capacity 30/45 Watt as per make and specification installed at site.
Electronic LED driver suitable for LED street light fitting capacity 60/70 Watt as per make and specification installed at site.
Electronic LED driver suitable for LED street light fitting capacity 90/120 Watt as per make and specification installed at site.
Electronic LED driver suitable for LED street light fitting capacity 150 to 200 Watt as per make and specification installed at site.
Supply and fixing in repair sheet moulding compound junction box shock and rust proof, termite resistant, tamper proof single phase, two wire rating of size 250 mm x 200 mm x 105 mm complete with one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole/wall complete all as specified and as directed.
S&F in repair street light bracket made of GI pipe medium grade bend in shape of 40 mm dia, 1.2 m long and clamped with 2 pairs of 30 x 5 mm flat iron clamps, nuts/bolts/washers & painted with two coats of aluminium paint over coat of a red oxide primer on clamps complete all as specified and as directed.
S&F in repair MS clamps including nuts, bolts and washers made out of MS flat strip 30x5 mm thick including cutting, bending, drilling holes in shape and size as per the pole size and fixing with PCC/steel tubular pole for holding of GI pipe brackets for mounting of street lights complete all as specified and as directed.
S&F in repair LED security light 45 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 4500 lumens including fixing on pole or any other location with the help of existing GI bracket including taking down existing unserviceable one complete all as specified and as directed.
S&F in repair LED security light 70 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 7000 lumens including fixing on pole or any other location with the help of existing GI bracket including taking down existing unserviceable one complete all as specified and as directed.
S&F in repair LED Security light 90 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 9000 lumens including fixing on pole or any other location with the help of existing high mast light structure including taking down existing unserviceable one complete all as specified and as directed.
S&F in repair LED Security light 150 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 9000 lumens including fixing on pole or any other location with the help of existing high mast light structure including taking down existing unserviceable one complete all as specified and as directed.
S&F in repair LED flood light 120 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 12000 lumens including fixing on pole or any other location with the help of existing high mast light structure including taking down existing unserviceable one complete all as specified and as directed.
S&F in repair LED flood light 150 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 15000 lumens including fixing on pole or any other location with the help of existing high mast light structure including taking down existing unserviceable one complete all as specified and as directed.
S&F in repair LED flood light 300 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 15000 lumens including fixing on pole or any other location with the help of existing high mast light structure including taking down existing unserviceable one complete all as specified and as directed.
S&F LED bollard with opal diffuser and aluminum reflector capacity 09 watt including fixing/ grouting on PCC platform of suitable size and taking down existing unserviceable one complete all as specified and as directed.
S&F in repair LED bollard with opal diffuser and aluminum reflector capacity 12 watt including fixing/ grouting on PCC platform of suitable size and taking down existing unserviceable one complete all as specified and as directed.
S&F in repair decorative LED Post top lantern luminaires with diffuser and painted spun aluminum deflector of capacity 12 watt including fixing arrangement including taking down existing unserviceable one complete all as specified and as directed.
Rewinding of Electric motor with existing super enamel copper wire of existing gauge including insulation and varnishing of capacity upto 2.5 HP including repair to gear box after dismantling all electrical and mechanical connection from High mast light, testing and commissioning at site complete all as specified and as directed.
M&L for replacement of high mast wire rope of existing size complete all as specified and as directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches/pipes, fixed to poles/walls, fixing with suitable saddle/clamps complete all as directed including taking out the old burnt out cables of following sizes complete all as specified and as directed.
10 Sqmm 2 core.
16 sqmm 4 core.
25 sqmm 3.5 core.
35 sqmm 3.5 core.
50 sqmm 3.5 core.
70 sqmm 3.5 core.
95 sqmm 3.5 core.
120 sqmm 3.5 core.
185 sqmm 3.5 core.
Excavation in trenches for foundation of poles, stays and laying underground cable in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and as directed.
All as per item serial No 40.00 here-in-before but deep exc 1.5 meter but not exc 3.0 meter complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing surplus excavated material to a distance not exceeding 50 meter and deposited where directed not exc 1.5 meter above the starting point complete all as specified and as directed.
M&L Sand cushioning using fine river sand for protection of under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and punned to required depth as specified cable complete all as specified and as directed. Note : Punned depth shall be measured for payment.
Supply and Laying Unreinforced precast concrete cable cover class LV type 1, size 250mmx150mmx40mm complete all as specified and as directed.
M&L for Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) for coping of poles including necessary formwork for smooth finish of concrete surface complete all as specified and as directed.
Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, flat, served with inner sheathing of PVC tape and overall PVC sheathed in service connections for providing electrical connections to existing security/street lights of size 1.5 Sqmm twin core complete all as specified and as directed.
All as per item No 49.00 here-in-before but size 2.5 sqmm complete all as specified and as directed.
All as per item No 49.00 here-in-before but size 4.0 sqmm complete all as specified and as directed.
All as per item No 49.00 here-in-before but size 6 sqmm complete all as specified and as directed.
All as per item No 49.00 here-in-before but size 10 sqmm complete all as specified and as directed.
M&L Earthing complete with GI earth plate 60x60cmx6mm thick electrode and 32 x 6 mm GI strip as earthing lead.burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI strip 32 x 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh, charcoal dust and salt etc and connected to earthing test point complete all as specified and as directed and testing including taking out the old unserviceable one.
All as per item serial No 54.00 here-in- before but earthing using galvanised iron earthing lead of 4.0 mm dia complete all as specified and as directed.
S&F in repair MCB single pole 230 volts 50 Hz AC of rating 06 to 32 Amp complete all as specified and as directed.
S&F in repair MCB single pole 230 volts 50 Hz AC of rating 40 to 63 Amp complete all as specified and as directed.
S&F in repair MCCB 400Amp rating, 4 pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36 KA complete all as specified and as directed.
S&F in repair MCCB 250Amp rating, 4 pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36KA complete all as specified and as directed.
S&F in repair MCCB 100Amp rating, 4 pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
S&F in repair MCCB 63Amp rating,4 pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
M&L for laying GI Tubing light grade 40mm dia for cable potection galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including removing the rusted old one complete all as specified and as directed.
M&L for laying GI Tubing light grade 50mm dia for cable potection galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including removing the rusted old one complete all as specified and as directed.
Taking down unserviceable solar street light fittings of any type/wattage/make etc for repairing including checking for repair/replacement of unserviceable parts as required and making the light fittings operational to give rated illumination by replacing unserviceable spare parts and refixing the same at existing location or any other location as directed at site complete all as specified and as directed. Notes : (i) Cost of taking down carefully from existing position, bringing to MES store yard (If required for repair), is deemed to be included in this item quoted rates. (ii) Cost of supply and fixing of major items required to make the lights serviceable shall be measured and paid separately under item No 51.1 to 51.5 of this schedule.
Supply only following items to be incorporated against item serial No 66.00 here-in-before complete all as specified and as directed.
Battery 12 volt 15 AH.
Solar panel for generation of solar energy capacity 07 watt.
Electronic battery charger suitable for 12 volts battery.
DC to AC convertor suitable for battery 12 volts.
LED security light 15 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 1500 lumens.
Supply and fixing in replacement of smart integrated light all-in-one type 40 Watt with built in premium grade mono crystalline solar panel 40 wp,Lithiumm base battery, single FRP body duly polyurethane coating (Camouflage color), encases with monocrystalline solar PV panel of 60 Wp,lithium battery 11.1/12.8V,33.0 AH with inbuilt BMS,IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminium reflector for better light distribution ,CRI>70, color temp 5700K-6500K Microcontroller based charge controller cum driver,automaticdimming function(First 04 hrs at full brightness & rest of the time at lower light level with PIR motion sensor), Dusk to dawn operation,suitable to working temp (-) 10C to (+) 55C ,weight not more thatn 16-18 Kg with adjustable MS clamp suitable for pole/wall mounting etc complete all as specified and as directed. Protections : Short circuit, overload, Reserve polarity and battery protection. Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint. (Excavation & earth work shall be measured separately)
Supply and erecting and fixing in true vertical position,hot dip galvanised inside and outside octagonal pole of 6 meter height with bottom outer dia not less than 130 mm and top outer dia not less than 70 mm and steel thickness 3 mm complete with base plate (200 X200X12 mm) mounting accessories with 04 Nos of M20X600 mm long 'J' type EN 8 grade foundation bolt alongwith templates (Steel plate for installing bolt accurately),PCD-200 mm,GI cap on top with 500 mm long hot dip galvanised single arm stadard bracket made up of 40 NB dia GI pipe as per requirement including clamp & nut &bolts and suitable arrangement to mount solar light as directed on pole having to 70 mm A/F and including foundation and errection as per manufacturer drawing complete all as specified and all as directed.
Supply and fixing in replacement power contactor 40 Amps, three phase, AC suitable for operation of timer switch enclosure complete all as specified and as directed.
M&L for Taking down unserviceable High Mast light poles, etc for repairing including complete dismantling, checking for repair/replacement of unserviceable parts as required including greasing etc.and making the high mast lights operational to replacing unserviceable spare parts and refixing the same at existing location or any other location as directed at site and making electrical connections with existing wire complete all as directed. Notes : (i) Cost of taking down carefully from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard (If required for repair), is deemed to be included in this item quoted. (ii) All T&P used for lowering/raising of High Mast lights/fittings etc are included in quotated rate.
Ms Kamal Kant Agarwal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .