| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.2 LAccepted-Finance | ₹8.2 L | 1 | Accepted-Finance O.K. |
| 2 | 2₹8.9 LAccepted-Finance | ₹8.9 L | 2 | Accepted-Finance O.K. |
| 3 | 3₹10.1 LAccepted-Finance MEERUT UTTAR PRADESH 250110 INDIA UDYAM UP 56 0008622 | MEERUT | UTTAR PRADESH | 250110 | ₹10.1 L | 3 | Accepted-Finance O.K. |
| 4 | 4₹10.5 LAccepted-Finance | ₹10.5 L | 4 | Accepted-Finance O.K. |
| 5 | 5₹10.7 LAccepted-Finance | ₹10.7 L | 5 | Accepted-Finance O.K. |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
9 Jun 2021, 5:00 pmClosed
SE ETC BAREILLY
Superintending Engineer Transmission Campus Near L.I.C. Office Rampur Garden, Bareilly
Replacement of 33KV Main Bus by changing the Single Moose Conductor with Double Moose Conductor alonghwih associated Materials and other associated works at 132KV Substation Aonla under E.T.D., Budaun
2021_UPTCL_586326_1
E-Tender No. 03/ETC(B)/2021-22
Open Tender
Electrical Works
90 days
Budaun
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
A/c No. 10897666087, IFSC, SBIN0000615, S.B.I. Bly
₹19,000
24 Aug 2021
12 May 2021
10 Jun 2021
12 May 2021
9 Jun 2021
12 May 2021
Amount
Replacement of 33KV Main Bus by changing the Single Moose Conductor with Double Moose Conductor alonghwih associated Materials and other associated works at 132KV Substation Aonla under E.T.D., Badaun with all Cost of Men, Materials, Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications and Direction of the Supervising Engineer, as per Details below :
Bolted type single tension fitting for twin Moose conductor with turn buckle for 33 kv main bus suitable for 70 KN disc insulator with 2 Nos. Tension clamps made of aluminium alloy LM-6 ,Yoke plate , D Shackle, D Socket,etc made from forged steel etc. as per technical specification , confirming to IS: 2486 .and duly type tested.
Bolted type single suspension fitting for twin Moose conductor without turn buckle for 33 kv main bus suitable for 70 KN disc insulator with 2 Nos. Suspension clamps made of aluminium alloy LM-6 ,Yoke plate , D Shackle, D Socket,etc made from forged steel etc. as per technical specification , confirming to IS: 2486 .and duly type tested.
33 KVbimettalic Circuit Breaker clamp made of aluminum alloy LM-6 one side connecting plate of size 100x100x15 mm another side connecting twin Panther conductor complete with hot dip galvanized Nut, Bolt & washer as per technical specification , confirming to IS: 5561 .and duly type tested.
33 KV bimettalic isolator clamp made of aluminiun alloy LM-6 one side connecting plate of size 80x80x15 mm another side connecting twin Panther conductor complete with hot dip galvanized Nut, Bolt & washers as per technical specification , confirming to IS: 5561 .and duly type tested.
33 KV Bi-metalic CT clamp made of aluminium alloy LM-6 one side connecting the CT rod another side connecting twin Panther conductor complete with hot dip galvanished Nut Bolt & washer as per technical specification , confirming to IS: 5561 .and duly type tested.
33 KV bimettalic PT clamp made of aluminium alloy LM-6 one side connecting the PT rod another side connecting twin Panther conductor complete with hot dip galvanished Nut Bolt & washer as per technical specification , confirming to IS: 5561 .and duly type tested.
04 bolted type P.G. clamp made of aluminium alloy LM-6 suitable for Moose to panther conductor complete with hot dip galvanized Nut, Bolt, spring & plain washer as per technical specification , confirming to IS: 5561 .and duly type tested.
03 bolted type P.G. clamp made of aluminium alloy LM-6 suitable for Panther to Panther conductor complete with hot dip galvanized Nut, Bolt, spring & plain washer as per technical specification , confirming to IS: 5561 .and duly type tested.
04 bolted type P.G. clamp made of aluminium alloy LM-6 suitable for Moose to Moose conductor complete with hot dip galvanized Nut, Bolt, spring & plain washer as per technical specification , confirming to IS: 5561 .and duly type tested.
Spacer for Moose conductor 02 Bolts, 250mm spacing complete with hot dip galvanized Nut Bolt , spring & plain washer as per technical specification , confirming to IS: 5561 .and duly type tested.
Spacer for Moose conductor 02 Bolts, 100 mm spacing complete with hot dip galvanized Nut, Bolt, spring & plain washer as per technical specification , confirming to IS: 5561 .and duly type tested.
Spacer for panther conductor 02 Bolts, 100 mm spacing complete with hot dip galvanized Nut, Bolt, spring & plain washer as per technical specification , confirming to IS: 5561 .and duly type tested.
33 KV Bimettalic Circuit Breaker clamp made of aluminum alloy LM-6 one side connecting plate of size 100x100x15 mm another side connecting twin Moose conductor complete with hot dip galvanized Nut, Bolt & washer as per technical specification , confirming to IS: 5561 .and duly type tested.
33 KV Bimetallic isolator clamp made of aluminiun alloy LM-6 one side connecting plate of size 80x80x15 mm another side connecting twin Moose conductor complete with hot dip galvanized Nut, Bolt & washers as per technical specification , confirming to IS: 5561 .and duly type tested.
33 KV Bi-metalic CT clamp made of aluminium alloy LM-6 one side connecting the CT rod another side connecting twin Moose conductor complete with hot dip galvanished Nut Bolt & washer as per technical specification , confirming to IS: 5561 .and duly type tested.
Post Insulator clamp made of aluminium alloy LM-6 supporting twin Moose conductor complete with hot dip galvanished Nut Bolt & washer as per technical specification , confirming to IS: 5561 .and duly type tested.
33 KV LA clamp made of aluminiun alloy LM-6 one side connection a plate of size 80x80x15 mm another side connecting twin Panther conductor & complete with hot dip galvanized Nut, Bolt & washer .The clamp shall be having minimum current carrying capacity of 630 Amp & confirm to IS : 5561 .
33 KV LA clamp made of aluminiun alloy LM-6 one side connection a plate of size 80x80x15 mm another side connecting twin Moose conductor & complete with hot dip galvanized Nut, Bolt & washer .The clamp shall be having minimum current carrying capacity of 630 Amp & confirm to IS : 5561 .
Bi-metalic terminal connector for 63 MVA T/F LV side bushing rod 30 mm dia suitable for Twin Moose conductor made of aluminiun alloy LM-6 complete with hot dip galvanished Nut Bolt & washer.The clamp shall be having minimum current carrying capacity of 800 Amp & confirm to IS : 5561 .
Opening of old & existing jumpers of ACSR Panther/Moose conductor between existing Single ACSR Moose Main Bus to Bus Isolators for all Feeder and Transformer Bays ,33 KV Bus Section Isolator,. Las & PTs and Bus to Bus Isolators of 33 KV Feeder Bays (One job for each jumper).
Dismantling of old & existing 33 KV Main Bus Bar Sec-tion of ACSR Moose Conductor of Span up-to 24Meter after opening the Tension Fittings from Gantry, lowering down the Bus Bar etc. including shifting of old conductor/fittings etc. from Switchyard to substation store (One job per phase per section).
Erection of new 33 KV Bus Bar of Span up to 24 Meter by laying and stringing of Twin ACSR Moose Conductor including Hosting of disc Insulator Strings & Tension Fitting etc. to be provided by Department after due cutting/fixing of spacers etc. to complete the work satisfactorily including shifting of all materials from store to Switchyard (One job per phase per section).
Jumpering by Twin ACSR Panther/Moose conductor as per standard specification between new Twin ACSR Moose Main Bus to Bus isolators for all feeder and transformers bays 33 KV Bus Section Isolators, Las &. PTs and between Bus isolators of 33 KV Feeders bays by proper cutting, opening & Tightening of Conductors using necessary PG Clamps & Equipment connectors to be provided by De-partment (One job for each Jumper).
Fixing of spacers clamp at an equal interval between Twin Moose /Panther conductor on Bus Bar section, between new main bus to bus isolators and between Bus Isolator to Circuit breakers of respective 33KV bay, LAs, PTs, CTs etc.
EMC Associates
Hi-tech power transmission
M/s S.S. Refregeration
M/S JAI SHREE ENTERPRISES
Bharat Trading Corporation
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid