Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-Finance | L1 | Accepted-Finance Being Lowest (L1) | |
| 2 | L2₹6.2 L+₹63,000 (11.4%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹6.3 L+₹80,000 (14.4%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹6.7 L+₹1.1 L (20.7%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L4₹6.7 L+₹1.1 L (20.7%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest |
| Sl No | Description | Qty | Unit | Priyanka Power line L1 | M/S Eagle Electricals And Rewinding Works L3 | Sachin Electricals L4 | Aziz Traders L5 | N D ELECTRICAL L4 | M/S ROHIT ENTERPRISES L6 | SI ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Leased Line Services :
Renewal/ Recharge and management of leased line connectivity for one year between the CME RTU/Modem and the SLDC Airoli , Navi Mumbai facility. This connectivity is required for the transmission of the prerviously implemented 21 data tags using the IEC 60870-5-104 (IEC 104) protocol and all as complete specified and directed by Engr in Charge
Note :-
1. Renewal to be done within one month from date of the work order .
2. Generation data Visibility Report from SLDC Airoli to will be submitted to Engr in Charge .
3. In case of delay in REnewwal of leased line connectivity , A penaly of RS 500 per day after 30 days of commencement of work shall be levied and the same shall be recoverd from Contractor . | 1 | Job | 2,85,000 ₹2,85,000 | 3,00,000 ₹3,00,000 | 2,30,000 ₹2,30,000 | 1,72,000 ₹1,72,000 Lowest | 3,10,000 ₹3,10,000 | 4,50,000 ₹4,50,000 | 3,05,000 ₹3,05,000 |
| 2.00 | SMB Communication Re-establishment:
Re-establish MODBUS communication from all 36 string Monitoring Boxes (SMBs) to the RTU ( Remote Terminal Unit ). | 1 | Job | 1,35,000 ₹1,35,000 Lowest | 1,65,000 ₹1,65,000 | 2,60,000 ₹2,60,000 | 2,51,000 ₹2,51,000 | 1,75,000 ₹1,75,000 | 1,50,000 ₹1,50,000 | 1,55,000 ₹1,55,000 |
| 3.00 | Data Transmission (FTP) :
Implement and ensure data transmission (e.g., historical logs, reports) to the QCA ( Quality Control Authority/Centre) utilizing File Transfer Protocol (FTP) .
Note :-
1. If any modification/addition is required in existing software/hardware, the cost of the same is deemed to be included in quoted price.
2. Payment for this item will be released only after a confirmation of data visibility from QCA is received by Engr-in-charge. | 1 | Job | 1,35,000 ₹1,35,000 | 1,70,000 ₹1,70,000 | 1,80,000 ₹1,80,000 | 2,52,000 ₹2,52,000 | 1,85,000 ₹1,85,000 | 1,00,000 ₹1,00,000 Lowest | 1,58,000 ₹1,58,000 |
| 4.00Note fro Item No 1 to 3. (a) Details of all communication data to RTU which will include SMBs, Weather Monitering system, Invertor , Transformer and outgoing Feeder to be submitted Engr-in-Charge. | ||||||||||
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
30 Jun 2026, 6:00 pmClosed
Shri Vikas Tanwar, IDSE, GE (CME) Khadki
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi, Pune
REPAIR/MAINT OF RTU FOR VISIBILITY OF GENERATION TO SLDC FOR REAL TIME MONITORING AS PER REQUIREMENT OF SLDC FOR GRID CONNECTIVITY OF 5 MW SOLAR POWER PROJECT AT CME UNDER GE (CME) KHADKI
2026_MES_770912_1
8719/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (CME) Khadki
₹12,000
Yes
13 Aug 2026
9 Jun 2026
2 Jul 2026
9 Jun 2026
30 Jun 2026
24 Jun 2026
10 Jun 2026 - 23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Leased Line Services :
Renewal/ Recharge and management of leased line connectivity for one year between the CME RTU/Modem and the SLDC Airoli , Navi Mumbai facility. This connectivity is required for the transmission of the prerviously implemented 21 data tags using the IEC 60870-5-104 (IEC 104) protocol and all as complete specified and directed by Engr in Charge
Note :-
1. Renewal to be done within one month from date of the work order .
2. Generation data Visibility Report from SLDC Airoli to will be submitted to Engr in Charge .
3. In case of delay in REnewwal of leased line connectivity , A penaly of RS 500 per day after 30 days of commencement of work shall be levied and the same shall be recoverd from Contractor . | 1 | Job | 10,000 | ₹10,000 |
| 2 | SMB Communication Re-establishment:
Re-establish MODBUS communication from all 36 string Monitoring Boxes (SMBs) to the RTU ( Remote Terminal Unit ). | 1 | Job | 10,000 | ₹10,000 |
| 3 | Data Transmission (FTP) :
Implement and ensure data transmission (e.g., historical logs, reports) to the QCA ( Quality Control Authority/Centre) utilizing File Transfer Protocol (FTP) .
Note :-
1. If any modification/addition is required in existing software/hardware, the cost of the same is deemed to be included in quoted price.
2. Payment for this item will be released only after a confirmation of data visibility from QCA is received by Engr-in-charge. | 1 | Job | 12,000 | ₹12,000 |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_863300.xls
BOQ • 0.32 MB
8719tender.pdf
Tender Documents • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .