Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.7 LAccepted-AOC TANNO COMPLEX BAJRANG CHOWK DIPKA DISTT KORBA CG 495452 | KORBA | CHHATTISGARH | 495452 | ₹2.7 L | 1 | Accepted-AOC L-1 bidder and has submitted all confirmatory documents as per NIT. |
| 2 | 2₹3.5 L+₹79,355 (29.6%)Rejected-Finance 0 GOPAL GANJ CHABUTRA KE SAMNE PRATAPGARH PRATAPGARH PRATAPGARH RAJASTHAN 312605 | PRATAPGARH | RAJASTHAN | 312605 | ₹3.5 L+₹79,355 (29.6%) | 2 | Rejected-Finance Quoted Higher rate |
| 3 | 3₹4.6 L+₹2.0 L (73.1%)Rejected-Finance 42 11 DIPKA PALI ROAD DIPKA DIPKA KORBA CHHATTISGARH 495452 | KORBA | CHHATTISGARH | 495452 | ₹4.6 L+₹2.0 L (73.1%) | 3 | Rejected-Finance Quoted Higher rate |
| Sl No | Description | Qty | Unit | V R ENTERPRISES L2 | SHASHI BHUSHAN SINGH L3 | SHOBHA ELECTRICALS AND ELECTRONICS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Steel fabrication work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. | 1,000 | Kg. | 8 ₹8,000 Lowest | 15 ₹15,000 | 10 ₹10,000 |
| 2.00 | Excavation for cable trenches in soft soil, depth upto 1.2m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and good soil after laying of cable / pipe etc. in layers of 20cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meters.
(Pole Pit size 0.5mx0.5mx1.2m = 0.3 cu.m. each and
Stay pit size 0.5mx0.5mx0.8m = 0.2 cu.m. each) | 10 | Cu.m. | 150 ₹1,500 Lowest | 290 ₹2,900 | 400 ₹4,000 |
| 3.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering & shuttering - All work up to plinth level.
1:3:6 (1 Cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
(Pole Pit size 0.5mx0.5mx1.2m = 0.3 cu.m. each and
Stay pit size 0.5mx0.5mx0.8m = 0.2 cu.m. each) | 10 | Cu.m. | 2,300 ₹23,000 | 3,450 ₹34,500 | 1,800 ₹18,000 Lowest |
| 4.00 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregare 40mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required. | 20 | Nos. | 2,250 ₹45,000 | 2,850 ₹57,000 | 1,000 ₹20,000 Lowest |
| 5.00 | Supplying & erection of galvanised stay set for 33KV overhead lines complete with 19/20mm dia x 1.8 meters long stay rod, anchor plate of size 45cm x 45cm x 7.5mm thick, thimble, stay clamps, turn buckle ( 20mm x 600mm), 7/4.00mm dia GI stay wire and 33KV strain insulator etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregare 40mm nominal size ) foundation including excavation and refilling etc. as required. | 20 | Nos. | 1,750 ₹35,000 | 1,250 ₹25,000 Lowest | 1,500 ₹30,000 |
| 6.00 | Erection of double pole 3 wire cross arm for 11/22/33 KV overhead lines as required. | 40 | Nos. | 350 ₹14,000 | 250 ₹10,000 Lowest | 300 ₹12,000 |
| 7.00 | Erection of pole top/ straight two wire / V shape two wire, angle iron / channel iron, cross arm on steel tubular / rail / PCC pole for 11/22/33KV as required. | 40 | Nos. | 150 ₹6,000 Lowest | 150 ₹6,000 Lowest | 200 ₹8,000 |
| 8.00 | Supplying & erection of 33KV pin insulator complete with large steel head GI pin, nuts, washers etc. as required. | 40 | Nos. | 300 ₹12,000 | 400 ₹16,000 | 230 ₹9,200 Lowest |
| 9.00 | Supplying & erection of a set of three 11KV disc insulatorfor 33KV overhead lines with galvanised insulator fittings, ball & socket type and complete with galvanised strain clamps, bolts,nuts, washers etc. as required. | 40 | Set | 1,250 ₹50,000 | 1,600 ₹64,000 | 450 ₹18,000 Lowest |
| 10.00 | Erection / stringing of ACSR Dog conductor including binding etc. as required. | 2 | Km | 9,500 ₹19,000 | 8,000 ₹16,000 | 5,000 ₹10,000 Lowest |
Tender Value
₹7.9 L
EMD Value
₹9,900
Closing Date
16 Mar 2026, 5:00 pmClosed
Staff Officer, EnM
Office of the Area General Manager, SECL Gevra Area - 495452
Re-arrangement, repairing and maintenance of existing 33KV Over head feeder no. F-1, F-13 and F-16 of 132/33KV Sub Station Sub Station, Gevra Area for 120 days within duration of monsoon
2026_SECL_354932_1
SECL/GA/SO ENM/25-26/E-TENDER/151 dt. 27/02/2026
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Gevra Area
Please refer Tender documents.
5 documents required · 5 mandatory
₹9,900
12 May 2026
2 Mar 2026
18 Mar 2026
2 Mar 2026
16 Mar 2026
3 Mar 2026
2 Mar 2026 - 9 Mar 2026
Steel fabrication work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
Excavation for cable trenches in soft soil, depth upto 1.2m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and good soil after laying of cable / pipe etc. in layers of 20cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meters. (Pole Pit size 0.5mx0.5mx1.2m = 0.3 cu.m. each and Stay pit size 0.5mx0.5mx0.8m = 0.2 cu.m. each)
Providing and laying in position cement concrete of specified grade excluding the cost of centering & shuttering - All work up to plinth level. 1:3:6 (1 Cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) (Pole Pit size 0.5mx0.5mx1.2m = 0.3 cu.m. each and Stay pit size 0.5mx0.5mx0.8m = 0.2 cu.m. each)
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregare 40mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required.
Supplying & erection of galvanised stay set for 33KV overhead lines complete with 19/20mm dia x 1.8 meters long stay rod, anchor plate of size 45cm x 45cm x 7.5mm thick, thimble, stay clamps, turn buckle ( 20mm x 600mm), 7/4.00mm dia GI stay wire and 33KV strain insulator etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregare 40mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of double pole 3 wire cross arm for 11/22/33 KV overhead lines as required.
Erection of pole top/ straight two wire / V shape two wire, angle iron / channel iron, cross arm on steel tubular / rail / PCC pole for 11/22/33KV as required.
Supplying & erection of 33KV pin insulator complete with large steel head GI pin, nuts, washers etc. as required.
Supplying & erection of a set of three 11KV disc insulatorfor 33KV overhead lines with galvanised insulator fittings, ball & socket type and complete with galvanised strain clamps, bolts,nuts, washers etc. as required.
Erection / stringing of ACSR Dog conductor including binding etc. as required.
Supplying & Painting and numbering of poles , as required. (Painting with Red oxide & Aluminium Paint)
Supplying & Erection of Anti climbing devices with barbed wire and danger Board on poles , as required.
Erection of cradle guard as required .
Dismantling of pole / street light standard/ strut embedded in cement concrete foundation etc. as required
Dismantling of overhead lines comprising of Copper / Aluminium over head conductor, GI wire, cross arms, insulators etc. as required
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead.
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 1.43 MB
Tendernotice_2.pdf
PDF • 0.82 MB
BOQ_367762.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .