Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹25.1 L+₹22,037 (0.89%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹26.4 L+₹1.5 L (6.24%)Rejected-Finance | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹69,000
Closing Date
9 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer MAF Jalahalli
Garrison Engineer MAF Jalahalli Bangalore 560013
8755REPAIR AND MAINT OF COOLING HEATING APPLIANCES AND CONNECTED WORKS UNDER GE M AF JALAHALLI BANGALORE
2023_MES_580083_1
8755/E8
Open Tender
Electrical and Maintenance Works
Item Rate
333 days
Garrison Engineer MAF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT PUBLIC FUND ACCOUNT
₹69,000
15 May 2023
9 Feb 2023
11 Mar 2023
9 Feb 2023
9 Mar 2023
23 Feb 2023
9 Feb 2023 - 16 Feb 2023
Amount
Taking out split type air conditioners indoor and out door units complete for repair/ servicing and overhauling of capacity 1.5/2.0 TR of any make/type after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower etc and also connecting of refrigerant pipe,drain pipe and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. Note :- (i) Spares will be measured and paid separately (ii) Refrigerant gas will be measured and paid separately.
Marerial and labourfor hermetically sealed compressor of split type air conditioner of 1.5 TR capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make : Voltas/Hitachi/Tecumseh/Kirloskar/LG/Blue Star
Marerial and labourfor hermetically sealed compressor of split type air conditioner of 2.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make:Voltas/Hitachi/Tecumseh/Kirloskar/LG/Blue Star
Supply and fix MS wall bracket suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed.
Marerial and labourfor leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering,flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in split type air conditioner upto 2 TR capacity and testing complete all as specified and directed Note:- Refrigerant will be measured and paid separately.
Supply and charging refrigerant gas (R-134a ) suitable for Refrigerators/water coolers and Deep freezers complete all as specified and directed. Make: Mafron or equivalent makes as approved by the GE. Note :- Charging of refrigerant shall be measured and paid separately
Supply and charging refrigerant gas (R-22 ) suitable for split type AC complete all as specified and directed. Make: Mafron or equivalent makes as approved by the GE. Note :- Charging of refrigerant shall be measured and paid separately
Supply only relay assembly suitable for split type air conditioner 1.5/2.0 TR capacity complete all as specified and directed.
Supply only fan motor with blade suitable for out door unit of split type air conditioner up to 2 TR capacity complete all as specified and directed.
Supply only contactor suitable for split type air condtioners upto 2 ton capacity complete all as specified and directed. LG/Samsung/Carrier/Blue star/Hitachi
Taking down the unserviceable IDU blower motor and supply and fix IDU blower motor capacity as per existing make all as directed for 1.5 / 2 TR split AC.
Supply only starting capacitor 80 to 100 mfd for split type air conditioners complete all as specified and directed. Make : Concap/Keltron/Asian/Tesla/sarda/ Siemens/Tibcon
Supply only running capacitor 50 -60 mfd for split type air conditioners complete all as specified and directed. Make : Concap/Keltron/Asian/Tesla/sarda/Siemens/ Tibcon
Supply only universal strainer air filters cum dryer suitable for Split Air conditioners of capacity up to 2 TR complete all as specified and directed Make:- As per sample
Taking down sensor unit PCB board from indoor unit of split type AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed.
Removing the old unserviceable swing motor of any type and supply and fix new swing motor of 1.5/2.0 TR capacity split type ACs complete all as specified and directed.Make:- As per sample
Taking down perished unserviceable insulation cover of refrigerent piping and supply and fix thermo rexine tape including brutile rubber insulation for refrigerent pipings of suitable size.
Material and labour for 20 mm Low density polyethylene pipes (LDPE) of pressure 6kgf/sqcm fixed complete on walls, ceilings including all accessories complete. (Drain pipe )
Taking out the old unserviceable capillary tube 0.064 inch and supply and fix new capillary tube with strainer for the split type ACs 1.5/2 TR capacity complete all as specified and directed.
Disconnecting and taking out the old unserviceable copper tubing and supply and fix copper tube of size 3/8"/5/8"/1/4"/1/2" dia including necessary soldering, flaring work and jointing testing complete all as directed
Removing the old unserviceable copper cable after disconnecting electrical connections and supply and fix PVC insulated, sheathed ,multistandard,1100 volts grade copper conductor cable of size 2.5 sqmm;3 core complete all as specified and directed.
Supply only new hand remote control of existing make suitable for 1.5/2 TR split type AC including 2 Nos batteries of suitable size and testing complete all as specified and directed
Dismantling indoor and outdoor units of split type air conditioner of any capacity after pumping down the gas,disconnecting electric connections without any damage to existing system, reinstalling of indoor and outdoor units in new locations complete with brackets and civil works (making holes in wall) as required, assembling of indoor & outdoor units including connection of suction and discharge pipes and testing etc with topping up refrigerant gas as required to maintain the pressure complete all as specified and directed.
Supply and fixing metal clad socket 20 Amps, AC, 230 volts in replacement of old u/s metal clad socket complete.
Supply and fixing metal clad plug 20 Amps, AC, 230 volts in replacement of old u/s metal clad plug complete.
Supply and fixing in repairs Single pole and neutral enclosure with a two pin and earth plug & socket with one sigle pole MCB 20 Amps, fixed to wall and making all connections all as directed. Make Havells / Legrand / Indo Asian
Taking down old MCB SP and Supply and fixing MCB SP 6 - 32 Amps rating, 'C' series , 10 KA breaking capacity, 240 V, 50 Hz AC supply including making all connections complete all as specified . Note :- Make : Indo Asian/ Havells / Legrand .
Removing old unserviceable condenser coil assembly from split type air conditioner upto 2 TR capacity supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
Removing old unserviceable cooling coil assembly from split type air conditioner upto 2 TR capacity supply and fix copper cooling coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
Removing old unserviceable 2-3 way refrigerant control valve from split air conditioner outdoor unit after evacuating of refrigrant gas and supply and fix 2-3 way valve suitable for split type ACs of capacity upto 2 TR and testing complete all as specified and directed.
Removing old unserviceable split type air conditioner indoor unit and deposited in store yard for safe custody and Supply and fix indoor unit of the split type air conditioner 1.5/2 TR capacity and complete with all accessories such as installation plate with screws, blower motor, swing motor, filters etc duly prewired and including connecting of existing refrigerant piping, electrical connections, drain pipe and testing etc complete all as specified and directed.Make: Carrier/LG/Blue star/Voltas.
Removing old unserviceable split type air conditioner outdoor unit and deposited in store yard for safe custody and Supply and fix outdoor unit of the split type air conditioner 1.5/2 TR capacity, complete with all accessories such as hermetically sealed compressor and condenser unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refrigerant gas piping, electrical connections and testing etc complete all as specified and directed. Make: Carrier/LG/Blue star/Voltas.
Supply only capacitor 2.5 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos/Universal/Tipcon
Supply only capacitor 4 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos/Universal/Tipcon
Supply only capacitor 6 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos/Universal/Tipcon
Servicing the Voltage Stabilizer 4 KVA/5 KVA single phase after replacing transformer, PCB,u/s electronic parts,setting/testing of buck/boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Taking out water cooler for servicing and leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing of 40 ltr to 150 ltr capacity of any make/type after disconnecting of electric connection, removing dust by using blower and cleaning all the components by using water and caustic soda, checking and replacing the spares like relay, capacitors,gasket, thermostat, PVC pipes, push cock/liftcock, float valves etc and charging of refrigerant gas if required including testing and fixing back in its original location complete all as specified and directed.
Replacing the corroded portion of the water cooler 40 ltr to 150 ltr capacity of any type/ make and providing the same gauge sheet in corroded portion by bending/welding, soldering and also providing base support legs complete all as specified and directed.
Material and labour for spray painting to water coolers upto 150 ltr capacity of any type /make with two coats of synthetic enamel paint over one coat of red oxide primer after removal of existing treatment and preparation of surfaces and including removing dents complete all as specified and directed.
Supply and fix hermetically sealed compressor for water cooler 40/80 litres capacity including initial filling of refrigerant gas to the required pressure and testing, also including removing the old unserviceable compressor complete all as specified and directed. Make: Voltas/Blue Star/Tecumseh/Kirloskar/Usha
Supply and fix hermetically sealed compressor for water cooler 120/150 litre capacity including initial filling of refrigerant gas to the required pressure and testing, also including removing the old unserviceable compressor complete all as specified and directed. Make: Voltas/Blue Star/Tecumseh/Kirloskar/Usha
Supply only capacitor 10-20 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos
Marerial and labourfor PVC drain hose pipe size 32mm dia LDPE waste hose pipe fitted to water cooler all as specified and as directed.
Marerial and labourfor PVC hose connection pipe 300 mm length both ends having brass coupling threaded for 15mm GI tubing of standard length.
Supply and laying of GI tubing medium grade 15 mm bore laid on floor/wall including all fittings such as bend,tea, union, elbow etc all direcdted as specified.
Supply and fix stop valve 15 mm dia, cast copper alloy chromium plated high pressure with crutch or butterfly handle screwed both ends for GI pipe/fittings inlcuding removing old unserviceable item complete all as specified and directed. Make : Prayag/Essco/Polytuff
Supply and fix push button tap, 15 mm dia, cast copper alloy chromium plated high pressure screwed for GI pipe/fittings inlcuding removing old unserviceable item complete all as specified and directed. Make : Prayag/Essco/Polytuff
Cutting exisiting steel tubing / PVC pipe for alterations or additions for 25/32mm all as specified.
Supply and fix in repair float valve / ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of size 15 mm bore suitable for water cooler complete all as specified and directed. Make : Prayag/Essco/Polytuff
Removing old unserviceable condenser coil assembly from water cooler any type supply and fix copper condenser coil assembly with all accessories suitable for water cooler of capacity up to 150 ltrs and testing complete all as specified and directed.
Supply only fan motor with blade ,single phase, 230V,50Hz for water coolers up to 150 Ltrs capacity complete all as specified and directed. Make : Usha/ AUE/Siemens/Keltron or equivalent any make with ISI marked
Supply only relay assembly suitable for water coolers capacity complete all as specified and directed.
Supply only thermostat switch for water coolers any type/ make complete all as specified and directed. Make: INDOFOSS/ RANUTRAL/AUE/Danfos
Supply and fix 15/16 Amps, three pin plug top,230 V,AC complete all as specified and directed
Taking out Refrigerator for servicing and overhauling of capacity up to 345 ltr (single door/Double door type) of any make/type after disconnecting of electric connection and cleaning all the components, checking and replacing the spare parts like relay, capacitors, thermostat,fused bulb and also including carrying out servicing, oiling, greasing and charging of refrigerant gas and testing complete all as specified and directed. Note :- (i) Spares will be measured and paid separately as supply only. (ii) Refrigerant gas will be measured and paid separately as supply only.
Supply and fix hermetically sealed compressor of Refrigerator up to 180 litres capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make: Voltas/Kelvinator/Tecumseh/Kirloskar/Usha/ Godrej
Supply and fix hermetically sealed compressor of Refrigerator 180 to 345 litres capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make: LG/Voltas/Kelvinator/Tecumseh/Kirloskar/Usha/ Godrej
Supply only relay assembly suitable for refrigerators of any type/ capacity up to 345 litres complete all as specified and directed. Make : Sarda/Annapurna/LG/Videocon/Whirlpool
Supply only bi-metal switch for refrigerators of any type/ capacity up to 345 litres complete all as specified and directed. Make:- LG/samsung/Videocon/Godrej/ Whirlpool
Supply only condensor coil suitable for refrigerators of any type/ capacity up to 345 litres complete all as specified and directed.
Supply only cooling coil suitable for refrigerators of any type/ capacity up to 345 litres complete all as specified and directed.
Supply only fan motor with blade suitable for refrigerators of any type/ capacity up to 345 litres complete all as specified and directed. Make : Samsung/Godrej/LG/Videocon/Whirlpool
Supply only thermostat switch for refrigerators of any capacity/ any type/ make complete all as specified and directed. Make: INDOFOSS/ RANUTRAL/Annapurna
Removing old unserviceable capilary copper tube of size 0.031" (Inch) and supply and fix new capilary copper tube suitable for existing type/make/size complete all as specified and directed.
Marerial and labourfor acrylic plastic chiller tray's such as suitable for Vegitable,side fixing tray's,ice cube tray's etc.,complete all as specified and directed.
Removing old unserviceable bulb from refrigerator and supply & fix new bulb suitable for existing type/make/capacity/size complete all as specified and directed
Taking down old unserviceable PCB board with electronic circuit from refrigerator of any capacity/type and supply & fix new PCB board including electronic circuit complete all as specified and directed.
Taking out deep freezers to workshop for servicing of capacity up to 500 Ltr of any make and any type by replacing unserviceable compressor and other parts from the machine as directed including charging of Refrigerant gas after vacumising and making system leak proof by leak testing with dry nitrogen,brazing the suction / discharge tubes where required,cleaning of condensing unit to achieve proper cooling effect,checking of electronic circuit of machine and service where necessary by replacing electronic parts and replacing the wirings with proper size of PVC insulated wires complete all as directed and testing complete.
Supply only Thermostatic switch suitable for Deep freezer of capacity up to 500 Ltr (Make : Indfos/ Denfoss/ Ranutal/Annapurna
Supply only Relay suitable for Deep freezer of capacity up to 500 Ltr. Make: As per samle
Supply and fix Fan Motor with blade, single phase,230V AC 50 Hz for Deep Freezer of any make and capacity up to 500 Ltr.
Supply and fix hermetically sealed compressor for deep freezer up to 500 Ltr capacity including initial filling of refrigerant gas to the required pressure and testing, also including removing the old unserviceable compressor complete all as specified and directed. Make: Voltas/Blue Star/Tecumseh/Kirloskar/Usha
Taking down storage type water heater (Geyser) 25/50 Ltrs capacity of any make/model/type from existing wall after disconnecting of electric and water supply connections and keeping the same in safe custody for carry out repairs/replacement of unserviceable spare parts & components such as heating element, thermostat,pilot lamps with wiring,insulating glass wool, thermal cut out,pressure release valve,safety valve,aperature plate assembly etc and examine water tightness of inner storage tank after cleaning and renewal of rubber washer/gasket and nut,bolts and washers etc and adjust to required range of thermostat control and assembling all parts/ accessories including fixing back in same location after connecting up of water & electric connections and testing for its satisfatory functioning complete all as specified and directed. Note:- (i) Spares will be measured and paid separately under relevant item of schedule as supply only (ii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate.
Supply only heating element 1.5/2 KW, suitable for storage type water heater (As per sample) Make:-Hot max/Bajaj/CG/Remson
Supply only thermostat suitable for storage type/instant water heater (geyser) of any type/ capacity
Supply only thermal cut out suitable for storage type/instant type water heater (geysers) of any type/ capacity
Supply only aperature plate assembly suitable for storage type water heater (geyser) 25/50 litre capacity complete all as specified and directed
Supply only pressure release valve suitable for storage type water heater (geyser) 25/50 litre capacity complete all as specified and directed
Supply only safety valve suitable for storage type water heater (geyser) 25/50 litre capacity complete all as specified and directed
Supply only inner tank suitable for storage type water heater (geyser) 25/50 litre capacity.
Supply only LED indicator pilot lamps(red and green lamps) with wiring round/square/rectangle suitable for geysers of any type
Supply and fix PVC pipe connections up to 600 mm in length suitable to connect GI pipe 15 mm dia to hot /Cold water outlet of geyser.Make: Kohinoor or eqivalent
Supply & fix bib taps,cast copper alloy chromium plated with crutch or butterfly handle,screwed down,screwed for iron pipe or for brass ferulle of size 15mm(1/2") dia pipe.
Material and labour for painting to storage type water heater(Geyser) of capacity 25/50 litre of any make/type to complete external body with two coat of synthetic enamel paint by using electric spray machine similar to match with existing colour after preparation of surfaces including marking MES Number with black paint complete all as specified and directed directed.Make of paint:-Asian/Berger/Nerolac Note:-Painting work to be carried out after dismantling of storage type water heater(geyser)
Taking down submain wiring of any size and making good to the disturbed surface of wall, floors, ceiling etc complete all as specified and directed
Supply and fixing Sub main wiring with Two runs of single core pvc insulated cable FRLS with copper conductor multistranded 1100 volts grade 4.0 sqmm through and including with suitable size of PVC conduit and its accessories , surface/ ceiling along with fixing arrangement etc including one run of 4.0 sqmm pvc insulated multistranded copper earth contuinuity conductor and connected to common earth dolly complete all as specified.
All as per item No 86 here-in-before but 2x 6sqmm with 1x6 sqmm as earth continuity conductor.
Supply and fixing Modular type switch 16 A,1 module in repairs.
Supply and fixing Modular type socket 6 A/16 A,2/3 pin combined 2 module in repairs.
Marerial and labourfor de-scaling of Flat type collector with suitable water softening agent or by circulating mild acidic solution through the collector pipes and drain out the scaling materials from the collector including cleaning of solar panels with soap solution,flushing with fresh water and sweeping with dry cloth complete all as directed by Engr-in-Charge.
Supply and fixing Solar collector panel suitable for 100/200/300LPD solar water heater complete all as directed by Engr-in-Charge.
Supply and fix in repairs Sacrificial Anode for better performance of 100/200/300 LPD Solar Water Heater.
Supply and fix in repairs toughened glass of suitable size for 100/200/300 LPD Solar Water Heater.
Supply and fix, in repairs, Gun metal gate valve conforming to IS-778-1984 non rustable spindle with cast iron wheel ISI marked suitable for screwing in GI pipes of 25 mm size
Supply and fix, in repairs, PVC/rubber hot and cold water pipes of 1" for inlet and outlet connection of collector.
Supply and fix GI tubing, medium grade, with all fittings 20 mm dia fixed on the floor/roof top for inlet and outlet connection.
Supply and fix hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore
Marerial and labourfor painting and repairing of steel structures of Solar Water Heating system to match with existing colour including replacing the corroded portion with same gauge by bending/welding complete all as specified and directed. .
Marerial and labourfor hermetically sealed compressor of Duct air conditioner of 4.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make:Voltas/Hitachi/Tecumseh/Kirloskar/LG/Blue Star
ANAND REFRIGERATION
SANTHAM TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .