Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.7 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹27.9 L+₹21,819.60 (0.79%)Rejected-Finance 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹27.9 L+₹22,324.89 (0.81%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹29.9 L+₹2.3 L (8.28%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹31.6 L+₹4.0 L (14.4%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
26 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIR REPLACEMENT OF UNSV SUBMAIN DB METER BOX BUS BAR CHAMBER AND OTHER ALLIED E M SERVICES AT NEW CANTT UNDER AGE E M GE NORTH PATIALA
2021_MES_494102_2
GE(N)/PAT-59/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹98,000
Yes
2 Feb 2022
30 Dec 2021
28 Jan 2022
30 Dec 2021
26 Jan 2022
13 Jan 2022
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm above with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supplying & laying factory made unreinforced Precast concrete cable covers class LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables complete all as directed.
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 35 Sqmm 3 & 1/2 Core all as specified & directed.
Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 25 Sqmm 3 & 1/2 Core all as specified & directed by Engr-in-Charge.
Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 16 Sqmm 4 Core all as specified & directed by Engr-in-Charge.
Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy dutyelectric cable with aluminium conductor, 1100 volt grade of cross sectional area 10 Sqmm 2 Core all as specified & directed by Engr-in-Charge.
Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLS ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed. Note : Above items are inclusive of (i ) Rigid non-metallic PVC conduit of 25 mm dia juction boxes, tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc all as specified and directed. (ii) Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc. to match the surfaces and making good, cutting not exc 10 cm girth all as specified and directed.
Supply and fix in replacement of MCB SP up to 6-32 Amp all as specified and directed.
Supply and fix in replacement of MCB SPN 6-32 Amp complete all as specified and directed.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The DB shall be fiush fixed and making good the disturbed surface shall be part of job at no extra cost complete all as specified and directed.
S&F in replacement sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways (one incoming three phase & four out goings three phase )for MCCB,ISOLATOR&MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity having IP 43 Protection complete all as specified and directed and comprising of the following (a)MCCB FOUR POLE 100 AMPS AC 415 VOLTS 10 KA IHLGSF0100 =01 NO as incoming (Note :- (i)The DB shall be VTPN (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
Cutting of hardstanding/wall for laying of cable including matching with suface by using cement concrete all as specified and directed.
M&L for Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and directed. Note: GI pipe shall be measured and paid seperately under relevant item.
Supply and fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed by Engineer-in-charge.
Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLS ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia incl 4.0 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed. Note : Above items are inclusive of (i ) Rigid non-metallic PVC conduit of 25 mm dia junction boxes, tees, bends,elbows,reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc all as specified and directed. (ii) Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc. to match the surfaces and making good, cutting not exc 10 cm girth all as specified and directed.
Sheet metal enclosure suitable for fixing DB and Electric meter, factory made of size 60 x 60 x 18 cm made out of 2mm thick MS sheet with double door, sutiable locking arrangements, powder coated, cutting chasing in wall and fixing and making good as per existing surface complete including removing old one, complete all as specified.
Repair to Electric panel box/body by repalcing the damaged/rusted MS sheet of existing gauge fabricated cut to size of original length incl providing hinges and other hard ware item like handless etc complete all as specified and directed.
Meterial and labour for making locking provision to the LT panel board/Electric Panel of any size/type by providing MS flat iron 25x6 mm up to lengh 15cm duly welded to the both front and back door duly holed for making provision for lock including welding of broken/unserviceable hinges/mounting arrangements of doors and matching with enamel paint of existing colour on the disturbed surfaces and providing pad lock not less than 75mm with triplicate key complete all as specified and directed by Engr-in-Chrage. Make of pad lock: Harrison/Navta/Godrej
M&L Painting to existing LT panel board of any type complete with two coat of weather proof synthetic enamel spray paint over a coat of red oxide primer after preperation of the surface complete all as directed by Engr-in-Charge.
M&L Painting to existing Enclosures for DB and Electric meter of any type complete with two coat of weather proof synthetic enamel spray paint over a coat of red oxide primer complete all as directed by Engr-in-Charge.
S & F PVC enclosure size suitable for single phase electric meter having security Seal Wire Make: SINTEX SPGSMB3527 (single phase) or equivalent. Item include cutting wall and making good the disturbed surface.
Taking up or down worn out/ damaged / partly serviceable/unserviceable PVC insulated underground cable, armoured, heavy duty with aluminium conductors of size 185 sqmm x 3.5 core,1100 volt grade from Trench/duct/pole/wall/roof tops etc, testing of cable in the presence of Engr-in-charge to ascertain seviceability,seggregating serviceable and unserviceable cable, keeping aside serviceable and unserviceable cable complete all as specified and directed .
All as per item No. 27 here-in before but for cable of size 3.5 core 95 sqmm.
Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 185 sqmm 3.5 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately.
All as per item No.29 here-in before but cable of size 3.5 core 95 sqmm.
S&F MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded aggregate) for filling and making good of disturbed surfaces of road/hard standing etc complete all as specified and as directed.
Material and labour for replacement of GI tubing light grade 80 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
M&L for removing of tiles from foothpath of any type any size and any description and relaying after laying of cable in all respect including preperation of surface and matching with existing surface complete including necessary sand filling all as specified and directed. Note:- Necessary PCC for disturbed foothpath for making good, shall be measured and paid separetly.
M&L cable jointing kit for 1100 Volt grade cable heat shrink type joint complete with jointing meterial and ascessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150 sqmm all as specified and directed
M&L cable jointing kit for 1100 Vgrade cable for indoor type heat shrink type joint complete with jointing meterial and ascessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 400 sqmm all as specified and directed.
MAHESH KUMAR SINGLA CONTRACTOR
The Rahul Vig
m/s s.n. builders
Jawandha Enterprises
Shivam Engg and fabricators
Arun enterprises
Arneja Builders
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .