Special Repair to Sub Health Center at Village Jiwan Nagar/ Khariwala/ Bani/ Bharolanwali in Distt. Sirsa (Pdg. E.I Internal only) RECALL
2020_HRY_121410_2
PWD/Elect-GGR/Elect-HSR/17074
Open Tender
Construction Works
Works
60 days
Hisar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Executive Engineer, Elect. Division PWD B and R Br
₹7,100
17 Feb 2021
14 Mar 2020
24 Mar 2020
14 Mar 2020
20 Mar 2020
14 Mar 2020
Amount
Main Switches Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. (HSR 31.12 (a). v) Double pole switch 32 amp. 415 Volts Cat-B,
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. (HSR 31.13) ii) Size 40 mm x 40 mm x 6 mm.
M.S.Sheet (HSR 31.14) i) Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. (HSR 31.17) Miniature circuit breakers of 9 KA breaking capacity. ii) SP MCB 6 amp. to 32 amp.
iii) SPN MCB 6 amp. To 32 amp.
Supply and erection of Fittings and Accessories. (HSR 31.18) xi) Bakelite angle / straight button holder large size.
xii) Switch 5 amp. On existing sheet.
xiii) Wall socket 5 amp. On existing sheet.
xxiv) Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
Erection and carriage of fans.. (HSR 31.20) v) Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
vi) Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
Pipe Laying. (HSr 31.21) Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. ii) Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness on surface
iii) Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness on surface
(Q) Earthing (HSR 31.22) i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
xii) Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required .
xiv) Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections. (HSR 31.26) iii) 6 Sq. mm 2 Core Ard. Cable.
IV) Supply and erection of weather proof M.S.Box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S.sheet hinged cover, locking arrangements , housed in wall , including the cost of 1 no. 16 amp. 415 volts kit-kat and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board in the M.S.Box including painting and necessary connections . (HSR 31.30)
Wiring only in 1.5sqmm PVC insulated copper conductor cable in existing conduit pipe and MS box covered with 5 mm thick Bakelite sheet including cost of switch, wall socket, ceiling rose etc. (HSR 31.38) i) Fan Point b) Medium Point
c) Long point
ii) Light Point a) Short Point
b) Medium Point
c) Long point
viii) 3 pin 15 amp. Plug point with 4 amp. PVC insulated copper conductor cable including earthing the 3rd pin etc. b) Medium Point
c) Long point
S/E of of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. (HSR 31.40) i) Cable size 1.5 sqm(3/0.81 mm)
iii) Cable size 4 sqm(7/0.85 mm)
v) Cable size 10 sqm(7/1.35 mm)
S/E of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. (HSR 31.41) iii) 12-way, SP&N (Horizontal)
S/E of PVC conduit pipe ISI marked (Medium) recessed in wall/ ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of the work. (HSR 31.44) b) 25mm dia
S/E of MS saddles and clamps on wall/ RCC parapet for fixing underground cable at a distance of 0.60 meter centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect upto the Engineer-in-Charge of the work. (HSR 31.48)
Supply and erection of 50mm diameter 1.5mtr. Long GI bracket (B-Class) making an angle 10 to 15 degree with horizontal plane for mounting street light fitting on GI bracket on wall with 2 Nos. 50mmx3mm thick MS flat including cost of cutting welding of GI bracket on wall with 2 nos. 50mm x 3mm thick MS flate including cost of cutting welding of GI pipe complete with cement sand mixture bolts and nuts etc including making necessary connection in all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (HSR 31.53)
Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Deluxe model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection etc. upto the entire satisfaction of the Engineer-in-Charge of the work. (HSR 31.55)
Non Schedule items S/E of 45 W LED Street light fitting < 100 Lumens per Watt Philips / Havell's / Wipro/ HPL make in aluminum pressure die casting housing toughened glass cover with IP-66 protection With Lense and dual surge protection device internal 5 KV and external 10 KV including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work.
S/E of 18 W indoor LED Tube fitting with batten and tube, decorative ultra slim liniare LED lighting fixture with extruded poly carbonate, environmental friendly, energy effiecent completed including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work. (Make:- Philips/ Havell's/ Crompton.)
Supply and erection of 48" AC Ceiling fan without regulator complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Bajaj / Orient/ Khaitan.
Supply and erection of Exhaust Fan 300 mm Industrial Heavy duty 900 RPM of of approved make list including the cost of all petty material required to complete the job upto the entire satisfaction of the Engineer -in-charge of the work.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .