Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
3 Jan 2022, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Creation and Augmentation of substation along with HT and LT Line
2021_PDD_148766_1
ED/UDH/53 of 2021-22 dt. 18-11-2021
Open Tender
Electrical Works
Turn-key
60 days
Various locations in District Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
Executive Engineer, Electric Division JPDCL
₹62,000
25 Jan 2022
20 Nov 2021
5 Jan 2022
20 Nov 2021
3 Jan 2022
20 Nov 2021
20 Nov 2021 - 27 Nov 2021
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Augmentation from 25 KVA to 63 KVA Sub Station at Pyt. Halqa Sunetar-B.
11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
120 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
LT Distribution Box for 63 KVA DTR with MCCB for incomer and SFU's for outgoing circuit
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
9 mtr. Long ST Pole (ST-410 SP33)
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Dismantling of Old 25kva Transformer along with allied materials, loading & transportation to Divisional Store Udhampur
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 1 Phase 2 wire 30mm² line on 8 mtr long ST poles at Pyt. Halqa Sunetar-B.
8 mtr. Long ST Pole (ST-410 SP15)
GI M-Clamp for shackle insulator
0.03 ACSR Conductor Weasel.
16kN Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm for LT
Painting of ST Poles 8 mtr including cross arm, clamps with one coat of Red Oxide
Painting of ST Poles 8 mtr including cross arm, clamps with 2 coats of Aluminium Paint
LT line spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut- bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr long ST poles 30 mm² ACSR Conductor at Kanah Saryal.
9 mtr. Long ST Pole (ST-410 SP33)
11 mtr. Long ST Pole (ST-410 SP56)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
0.03 ACSR Weasel conductor
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm for LT
Painting of ST Poles 9/11 mtr including cross arm, clamps with one coat of Red Oxide
Painting of ST Poles 9/11 mtr including cross arm, clamps with 2 coats of Aluminium Paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 25 KVA Sub Station at village Kanah Mohra Saryal.
11/0.433kV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge arrestor 9KV, 10KA, LA with polymer housing station type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
LT Distribution box for 25 KVA DTR with MCCB
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Painting of sub station ST poles/cross arms/clamps with one coat of Red oxide and two coats of aluminium paint
Danger Plates with Clamps
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 1 phase 2 wire LT 30 mm² line on 8 mtr long ST poles at Kanah, Mohra Saryal.
8 mtr. Long ST Pole (ST-410 SP15)
GI M-Clamp for shackle insulator
0.03 ACSR Conductor Weasel.
16kN Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm for LT
Painting of ST Poles 8 mtr including cross arm, clamps with one coat of Red Oxide
Painting of ST Poles 8 mtr including cross arm, clamps with 2 coats of Aluminium Paint
LT line spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 11 KV line on 9 mtr long ST poles at Shiv Nagar Dhalper.
9 mtr. Long ST Pole (ST-410 SP33)
11 mtr. Long ST Pole (ST-410 SP56)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
0.03 ACSR Weasel conductor
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm for LT
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Painting of ST Poles 9/11 mtr including cross arm, clamps with one coat of Red Oxide
Painting of ST Poles 9/11 mtr including cross arm, clamps with 2 coats of Aluminium Paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Augmentation from 25 KVA to 63 KVA Sub Station at Shiv Nagar Dhalper.
11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
120 mm² Single-Core Cable, 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
LT Distribution for 63 KVA DTR with MCCB for incomer and SFU's for outgoing circuit
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
9 mtr. Long ST Pole (ST-410 SP33)
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Dismantling of Old 25kva Transformer along with allied materials, loading & transportation to Divisional Store Udhampur
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 1 phase 2 wire on 8 mtr long ST poles at Panchayat Dhalper, Mohra Shiv Nagar .
8 mtr. Long ST Pole (ST-410 SP15)
GI M-Clamp for shackle insulator
0.03 ACSR Conductor Weasel.
16kN Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm for LT
Painting of ST Poles 8 mtr including cross arm, clamps with one coat of Red Oxide
Painting of ST Poles 8 mtr including cross arm, clamps with 2 coats of Aluminium Paint
LT line spacers
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .