Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.0 LAdmitted-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L1 | Admitted-Finance | |
| 2 | L2₹67.9 L+₹3.9 L (6.11%)Admitted-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L2 | Admitted-Finance | |
| 3 | L3₹74.7 L+₹10.8 L (16.8%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Shine Enterprises L3 | Bharat Sales Corporation L1 | DURGAI ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Material and labour for disc type insulator, single disc assembly, heavy polymeric insulator to suit 11 KV HT working pressure of size 145 mm height, 255 mm dia, including one galvanized mild steel spindle, two galvanized iron washer and one GI nut complete including dismantling existing old insulator from position all as specified and as directed. | 6 | Each | 800 ₹4,800 | 500 ₹3,000 Lowest | 550 ₹3,300 |
| 2.00 | Material and labour for pin type heavy polymer insulator to suitable 11 KV HT of working pressure of size 150 mm height, 150 mm dia, including one galvanized mild steel spindle, two galvanized iron washer and one GI nut complete including dismantling existing old insulator from position all as specified and as directed. | 6 | Each | 350 ₹2,100 | 165 ₹990 Lowest | 250 ₹1,500 |
| 3.00 | Material and labour for Post type heavy polymer insulator suitable for 11 KV HT working pressure including dismantling existing old insulator from position, all as specified and as directed. | 12 | Each | 500 ₹6,000 | 230 ₹2,760 Lowest | 250 ₹3,000 |
| 4.00 | Replacement of ACSR type jumpers(appx 1.5 RM in length) of suitable dia including aluminium lugs of suitable size for HT structures and yards including PVC insulation pipe and cleaning of carbon deposited on joints, applying jelly to each dismantling old jumpers complete all as directed. | 32 | Each | 400 ₹12,800 | 200 ₹6,400 Lowest | 450 ₹14,400 |
| 5.00 | Dismantling/Taking down 11 KV HT drop out fuse assembly with DO Fuse unit and Triple pole Air break switch mechanism complete all as directed. | 2 | Each Set | 500 ₹1,000 Lowest | 500 ₹1,000 Lowest | 1,000 ₹2,000 |
| 6.00 | Material & Labour for HT Drop out fuse assembly of 11 KV current Rating of 200 Amps with 2 post type heavy polymer insulator per phase, double stack channel type including steel base mounting frame, MS Nuts and bolts complete all as specified and directed. | 2 | Set of three | 6,000 ₹12,000 | 5,500 ₹11,000 | 5,000 ₹10,000 Lowest |
| 7.00 | Material & Labour for outdoor type Gang operated Air break switch triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level with GI pipe medium grade, for current rating up to 200 Amps suitable for vertical mounting fixed type complete with 09 Nos HT insulators suitable for HT 11 KV complete all as specified and directed. | 2 | Each | 16,000 ₹32,000 | 12,000 ₹24,000 Lowest | 16,000 ₹32,000 |
| 8.00 | All as per Item No.7 above but for current rating up to 400 Amps complete all as specified and directed. | 2 | Each | 17,000 ₹34,000 | 13,500 ₹27,000 | 11,000 ₹22,000 Lowest |
| 9.00 | Material & Labour for Lighting Arrestor (LA) Zinc oxide type complete with all fittings transmission class, discharge capacity 10 KA, suitable for 12 KV complete all as specified and directed. | 4 | Set of three | 4,600 ₹18,400 | 3,000 ₹12,000 Lowest | 3,000 ₹12,000 Lowest |
| 10.00 | Repairing/Servicing the Air break isolating switch 11 KV 200 Amps by replacing the defective major spares including provn of worn out bolts nuts etc, applying petroleum jelly on moving/fixed contacts all as specified Note :- Major spare will be measured & priced separately under relevant item of Sch item No. 11 | 9 | Job | 1,000 ₹9,000 Lowest | 2,000 ₹18,000 | 2,000 ₹18,000 |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
13 Nov 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Saikat De
CWE (Navy) Vasco
MAINT AND UPKEEP OF HT LT OVERHEAD LINE HT LT FEEDER AT NOFRA VARUNAPURI UWR AND UNDER GE NW VASCO
2026_MES_793107_1
86150/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Vasco
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE(NW) Vasco
₹1.4 L
Yes
17 Nov 2026
9 Oct 2026
16 Nov 2026
9 Oct 2026
13 Nov 2026
30 Oct 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for disc type insulator, single disc assembly, heavy polymeric insulator to suit 11 KV HT working pressure of size 145 mm height, 255 mm dia, including one galvanized mild steel spindle, two galvanized iron washer and one GI nut complete including dismantling existing old insulator from position all as specified and as directed. | 6 | Each | 53 | ₹318 |
| 2 | Material and labour for pin type heavy polymer insulator to suitable 11 KV HT of working pressure of size 150 mm height, 150 mm dia, including one galvanized mild steel spindle, two galvanized iron washer and one GI nut complete including dismantling existing old insulator from position all as specified and as directed. | 6 | Each | 10 | ₹60 |
| 3 | Material and labour for Post type heavy polymer insulator suitable for 11 KV HT working pressure including dismantling existing old insulator from position, all as specified and as directed. | 12 | Each | 11 | ₹132 |
| 4 | Replacement of ACSR type jumpers(appx 1.5 RM in length) of suitable dia including aluminium lugs of suitable size for HT structures and yards including PVC insulation pipe and cleaning of carbon deposited on joints, applying jelly to each dismantling old jumpers complete all as directed. | 32 | Each | - | - |
| 5 | Dismantling/Taking down 11 KV HT drop out fuse assembly with DO Fuse unit and Triple pole Air break switch mechanism complete all as directed. | 2 | Each Set | 10 | ₹20 |
| 6 | Material & Labour for HT Drop out fuse assembly of 11 KV current Rating of 200 Amps with 2 post type heavy polymer insulator per phase, double stack channel type including steel base mounting frame, MS Nuts and bolts complete all as specified and directed. | 2 | Set of three | 10 | ₹20 |
| 7 | Material & Labour for outdoor type Gang operated Air break switch triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level with GI pipe medium grade, for current rating up to 200 Amps suitable for vertical mounting fixed type complete with 09 Nos HT insulators suitable for HT 11 KV complete all as specified and directed. | 2 | Each | - | - |
| 8 | All as per Item No.7 above but for current rating up to 400 Amps complete all as specified and directed. | 2 | Each | 1 | ₹2 |
| 9 | Material & Labour for Lighting Arrestor (LA) Zinc oxide type complete with all fittings transmission class, discharge capacity 10 KA, suitable for 12 KV complete all as specified and directed. | 4 | Set of three | 1.25 | ₹5 |
| 10 | Repairing/Servicing the Air break isolating switch 11 KV 200 Amps by replacing the defective major spares including provn of worn out bolts nuts etc, applying petroleum jelly on moving/fixed contacts all as specified Note :- Major spare will be measured & priced separately under relevant item of Sch item No. 11 | 9 | Job | 1.25 | ₹11.25 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
86150Tender.pdf
Tender Documents • 0.80 MB
BOQ_889392.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .