| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81 LAccepted-AOC VILL BARANGABARI PO KACHUBARI PS TAMULPUR DIST TAMULPUR PIN 781354 | KAMRUP | ASSAM | 781354 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L1₹81 LRejected-Finance | L1 | Rejected-Finance Poor Experience in building construction compared to Sri Deepankar Daimary | |
| 3 | L2₹90 L+₹9 L (11.1%)Rejected-Finance PATACHARKUCHI WARD NO 4 PO PS PATACHARKUCHI DIST BARPETA ASSAM | L2 | Rejected-Finance Quoted High | |
| 4 | L3₹90.4 L+₹9.4 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Quoted Highest | |
| 5 | Rejected-Technical | - | Rejected-Technical EMD Not Submitted |
Tender Value
₹90 L
EMD Value
₹1.8 L
Closing Date
7 Dec 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Project Director, DRDA, Baksa
O/o the Project Director, DRDA, Baksa
Construction of CFC Building including Common Service Centre under Tamulpur Tribal Rurban Cluster fund for the year 2019-20
2021_BoTC_23509_1
DRDA/Baksa/01/2021
Open Tender
Civil Works
Works
180 days
Tamulpur
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,800
Yes
Principal Secretary, BTC
₹1.8 L
Yes
21 Dec 2021
29 Nov 2021
7 Dec 2021
29 Nov 2021
7 Dec 2021
29 Nov 2021
29 Nov 2021 - 7 Dec 2021
180 days
Amount
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. I. By Manual Means (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (i) In prop 1cement: 3 sand :6 coarse aggregate by volume
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc.
c) ISI approved Mild steel reinforcement bar(M.S.Bar)
Providing from work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns , pillars , posts & strut of square / rectangular /polygonal in plan or any shape like Tee/L etc. havingplane vertical face.
3.2.1.2. Sides and soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
3.2.1.3. Flat Surfaces such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas, balconies and the like . (a) Floors etc. upto 200mm in thickness.
Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work. (form work and reinforcement will be measured and paid separately) (I) Using Mixture machine (A) Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. a) M15 grade concrete or Prop. 1:2:4
(b) In Super Structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. a) M15 grade concrete or Prop. 1:2:4
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proportion 1:5. (1 cement:5 sand)
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc. Complete as directed by the department for all levels. (P.C.C. to be measured and paid for separately). (a) 1.25mm thick sheet (iii) Size 125mm x 60mm (Single rebate)
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent IS code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. a) Decorative type face panel and block board core. (ii) 35 mm thick .
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). a) Side hung and Top hung windows and ventilators iii) 6mm coloured glass
Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mmx60mm (Toletance + 1mm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mmx100mm or plastic brackets of size 75mmx75mm with metred cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mmx20mm. The frame will be fixed to the column/ stiffner/ wall with the help of 3 nos 75mm long and 4mm dia steel screws and expandable fastners on each side of the door frame complete in all respects as sepcified and directed at all levels.
Providing, fitting and fixing PVC Door shutters of Duroplast DPS 3720 make made fromm extruded PVC stiles and rails made from rigid PVC multicavity hollow chamber section of size 90mmx37mm (Toletance+ 1mm). The corners of the stiles and rails shall be metred out and fixed to each other with the help of solid plastic L-shaped brackets or M.S. rectangular tubular galvanised two nos of size 200mmx100mm and 100mmx100mm at each corner by self tapping steel screws. PVC multicavity hollow section of size 105mmx37mm shall be fixed in the middle by aluminium cleat and steel screws as lock rail. The section frame shall then be filled with PVC panels of approved colour of size 100mmx20mm. Then two numbers of bright steel rods of 6mm diameter shall be inserted horizontally through stiles and panels with two numbers of checknuts and washers all complete as specified and directed at all levels. (Door fixtures and fittings to be measured and paid seperately)
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. c) In cement mortar 1:5
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side c) In cement mortar 1:5
Providing, fitting and fixing M.S. Grill of required pattern for windows/ clerestory windows/ opening with M.S. flats at required spacing in frame all round, square or round M.S. Bars with round headed bolts and nuts or screws. I . Plain grill (b) Fixed to steel frames
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. b) Using other ISI marked approved brand tube
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self-drilling, self-tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Department (iii) 0.50 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50 mm thick
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/ Sika/ Pedelite/ Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
ANTISKID TILES Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. 5.11.2 VITRIFIED iii)Executive range-2 (Sizes 600 mm x600mm and above) i) Nitco made a). Imperia Series- Gres Tiles
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/ Sika/ Pedelite/ Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mmx450mm and above
Cement plaster kirting with cement mortar (1cement :3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. a) 15mm thick
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle ........................... at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (i) 9.5mm thick
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6)10cm thick sides 10cm thick bed over brick flat soiling including 15mm thick cem,ent plastering in prop 1:3: finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified . (i) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
PLASTER OF PARIS & WALL PUTTY Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (i) Thickness = 1.5 mm thick
WALL PAINTING Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after thoroughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra over item no 13.4.1 above for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). (i).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
EXTERIOR PAINTS / COATINGS Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Applying primary coat over new steel and other metal surface over 100mm in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. a). General purpose
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete (anodised to bright natural matt & satin finished) (a) Sliding door bolts - (ii) 250mm x 16mm
(b) Tower bolts (ii) 250mm x 12mm
(c) Door handles - (ii) 150mm
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city
Providing drain with cement concrete (1:3:6)10cm thick sides 10cm thick bed over brick flat soiling including 15mm thick cem,ent plastering in prop 1:3: finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified . (i) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Water Supply Stage including Water Supply Facility Earth work in excavation for foundation trenches of walls, retaining walls,footings of columns,steps and septic tank etc. including refiling (return filling) the quantity as necessary after completing of work, breaking clods in return filling dressing, watering and ramming etc and removal of surplus earth with all lead & lift as directed and specified in followng classification of soils including bailing out water where necessary as directed and specified. (A) Up to depth of 2.0 m below the existing G.L (a) In Ordinary Soil:
Providing brick work soiling in foundation and under floor with stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering , complete . (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32 mm in foundation bed for footting, steps, walls,brick works etc. as directed and specified including dewatering if necessary, and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1cement : 3 Sand : 6 coarse aggregate by volume. ( using mixure machine)
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) (ii) Super Ductile (SD) TMT reinforcement bars
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 1. Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
5. Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
Providing & laying reinforcement cement concrete works in prop 1:2:4 ( 1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work. (form work and reinforcement will be measured and paid separately) (a) In Sub-Structure up to plinth level Foundation, footings, columns with base, tie & plinth beam, pile cap,base slab,r etaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. b) M20 grade concrete or Prop. 1:1.5:3
(b) In Super Structure from plinth level up to 1st floor level. (ii) Columns , Pillars , posts, struts , suspended floor, roof landing,shelf & support balcony,lintel,sill band,beam,girder, bressumer , cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. b) M20 grade concrete or Prop. 1:1.5:3
Water Supply Works Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. i) Bore hole of 75mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. (I) G.I. pipe a) TATA / SAIL (Medium) socket should be welded to the pipes. i) 50mm diameter
Supplying fitting and fixing GI filter 2.00 metre long.
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Supplying fitting and fixing check valve (non return valve) including thread to pipes. iii) 40mm diameter
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (iii) 1000 litre capacity (a) Sintex make
Labour for erecting and placing PCVCTank over the stagging of 5.00m up to 8.00m complete as directed. (c) 1000 litre capacity
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) b) 40 mm dia
d) 25 mm dia
f)15 mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (ii) Jaquare make (ii) Bibcock long thread
(ii) Jaquare make (iii)2-Way bib cock
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (v) 40mm dia
(iii) 25mm dia
Wiring for light/ fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Wiring 5 a pin 6Amps plug point with 1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete Short point up to 3.00 metre. length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 4 module type Metal
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying and fixing of batten holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.)as required Without Lamp
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Power Flow 225 mm sweep (ORIENT make)
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting vertical TPN MCB DB incorporated with bas-bar 125A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4 way TPN (4+12) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) 6-32 A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 63A
Wooden L-Shape Office Table • Material -Wood. • Shape-L Shape • Width -402 mm • Height 512-700 mm
Chair (wooden) Width - 76 cms. Hight -10B.B Cms. Depth 76 Cms. Material - wood.
Office Table Material - Metal Colour -Standard SizeW x 0 x H Cms. 120x60x72.B Shape -Rectangular
Executive Revolving Chair Chair height -4B.5" I Seat Width -21" Seat Depth -21" Colour - Black
Visitor Chair - without arm Dimension- 23 (L) x 21 (W) x 30 (H) Inch
Steel Almirah (78"x36"x18")
Computer sets(Branded) i.10th Generation lntel" Core i5 processor, Windows 10 Pro 64, 8 GB DDR4-2666 SDRAM (1 x 8 GB), 1 TB 7200 rpm SATA HDD, Intel UHD Graphics, 5.7 kg. 54.61 cm (21.5") diagonal FHDVA, widescreen LCD anti-glare WLED-backlit (1920 x 1080 ii. Antivirus total Security.
2KVA Inverter with RC 18000 Battery (2 Batteries), Battery feature: low antimony alloy used - very low maintenance robust tubular plates provide many years of service excellent over charge tolerance (acceptsvery deep discharge-suitablefor long power cuts) tubular plate battery ideal for longer power cut areas warranty- 18+18 months capacity- 150ah Inverter feature: sinewave technology. High over-load handling capacity installation and maintenance friendly eco-friendly: say no to fumes, noise and pollution no user- action required: automatic start 2kva/24v capacity. 24 Months wararnty .Upto 21 amp charging current. Maximum bulb load - 1600 watt Inverter dimension: 280(1) x 305(w) x 280(h) mm, inverter weight: 31.90, Battery dimension: 503(1) x 189(w) x 411(h) mm, battery dry weight: 28.4 Kg, filled weight: 52.1 Kg, backup time 500 VI: 2 hrs 10 mint, 400 w: 2 hrsSOmint, 300w: 4 hrs, 200w: 6 hrs 40 mint, 100 w: 15 hrs 30 mint Running load combination, cfl (14 watts): 5, tube light (40 wattes): 5, ceiling fan (90 watt): 5, televion(led 40 inch): 2, refrigerator (singledoor 190 litre): 1, desktop (250 watts): 1, water router (1 hpj without lighting load: 1 Forcorrect fitment.
Computer Table - Dimentions - H 29.5 x W 35.5 x D1 17.7 (all dimensions are in inches) Assembly : Carpenter Primary Material : Engineerd Wood.
Computer Chair 45.8 x 38.9 x 42.8 cms
Printer - Branded Product Specification Function Type - Multifunction Memory - 64 MB Output Type - Monochrome Operating Humidity 10-80% RH Range - Flat bed Scanner Type - 32x32 mm Display Size - 32x32 mm Technology - Never stop Iaser Scanning Bit Depth - 24 Bit Media Size - A6, A5, A4, Letter Media Sizes Supported No.10 Env, B5(JIS) Voltage - 220-240 V Height & Width - 105 x 148.5 to 215.9x297 mm
Xerox machine (Branded) Dimensions: 518 x 445 x 298 mm (W x D x H) Print Technology: Laser Power Consumption: 1 kW Paper Weight: 56 - 80 gsm (56-128 gsm via bypass), Volta 220/240
Air Conditioner LG/Samsung/Voltas/Panasonic- 1.5 ton with automaic stabilizer and fittings
Wooden Warping Drum Machine with Book Creel, Circumference Heck Frame and other accessories and installation - 5 Mtrs Circumference
Hank to bobbin winding machine Including installation & Training for 5 days. 10 bobbin Capacity
Pirn winding machine including Installation & 5 days Training.
Wooden Office Table Material Wood, Colour -Standard Size W x 0 x H Cms. 120x60x72.8, Shape -Rectangular
wooden Chair With arms (Standard Size)
Double seater class room Desk & Bench (Branded) Depth -1051 mm Width-1200 mm-Height-7255 mm
White board - Size -4' x 6'
Projector (Including Installation) Technical Specifications- Maximum Projection Size -60 inch - 300 inch, Projection Distance -100 inch, Projection Ratio -1.50 - 1.6 (Throw Ratio), Keystone Adjustment-Auto Keystone Vertical ± 40 degree, Lamp Power -240 Watts, Lamp Lifetime - Normal: 4000 hours, Eco: 10000 hours, Smart Eco: 8000 hours, Lamp Save: 15000 hours.
CC camera (Including Installation) IP Camera Kit /3 x 4MP Mini Eyeball / Wi-Fi, Video Doorbell / 2.8 mm Fixed Len /4- Channel / 4k NVR / 2TB HDD / IP67 / Starlight / DH-N444E42A
Computer sets(Branded) 10th Generation lntel" Core i5 processor, Windows 10 Pro 64, 8 GB DDR4-2666 SDRAM (1 x 8 GB), 1 TB 7200 rpm SATA HDD, Intel UHD Graphics, 5.7 kg. 54.61 cm (21.5") diagonal FHDVA, widescreen LCD anti-glare WLED-backlit (1920 x 1080 ii. Antivirus total Security.
Air condition (Including Installation) 1.5 Ton, Inverter 5-STAR.copper MS-Q18GWZD, R32) 5 in 1 convertible.
2KVA Inverter with RC 18000 Battery (2 Batteries) Battery feature: low antimony alloy used - very low maintenance robust tubular plates provide many years of service excellent overcharge tolerance (accepts very deep discharge-suitable for long power cuts) tubular plate battery ideal for longer power cut areas warranty- 18+18 months capacity - 150 ah Inverter feature: sine wave technology. High overload handling capacity installation and maintenance friendly eco friendly: say no to fumes, noise and pollution no user- action required: automatic start 2kva/24v capacity. 24 Months
Computer Table - Dimentions - H 29.5 x W 35.5 x D1 17.7 (all dimensions are in inches) Assembly : Carpenter Primary Material : Engineerd Wood.
Computer Chair 45.8 x 38.9 x 42.8 cms
Printer - Branded Product Specification Function Type - Multifunction Memory - 64 MB Output Type - Monochrome Operating Humidity 10-80% RH Range - Flat bed Scanner Type - 32x32 mm Display Size - 32x32 mm Technology - Never stop Iaser Scanning Bit Depth - 24 Bit Media Size - A6, A5, A4, Letter Media Sizes Supported No.10 Env, B5(JIS) Voltage - 220-240 V Height & Width - 105 x 148.5 to 215.9x297 mm
Sign Board
SRI DEEPANKAR DAIMARY
Mahirul Islam
Hitesh Kumar Das
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .