Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-Finance | ₹21.5 L | L1 | Accepted-Finance accepted |
| 2 | L2₹21.8 LRejected-Finance | ₹21.8 L | L2 | Rejected-Finance rejected |
| 3 | L3₹21.9 LRejected-Finance | ₹21.9 L | L3 | Rejected-Finance rejected |
Tender Value
₹21.5 L
EMD Value
₹42,941
Closing Date
13 Jan 2026, 4:00 pmClosed
EXECUTIVE ENGG BED
EXECUTIVE ENGG BED OFFICE LOUIS JUBLEE COMPLEX
CONSTRUCTION OF SAMAJ GHAR AT GURUNG BUSTY P.O NORTH POINT GTA DARJEELING
2025_GTA_976973_1
NIeT20 4th call/2025-26 Dated-19/12/2025
Open Tender
CIVIL WORKS
120 days
Darjeeling
EMD,PRE-QUALIFICATION,BID CAPACITY,FORM X Y,DECLARATION
3 documents required · 3 mandatory
₹1,005
₹42,941
3 Feb 2026
19 Dec 2025
15 Jan 2026
19 Dec 2025
13 Jan 2026
19 Dec 2025
Earthwork in cutting to form road section in corrrect profile including removal of spoils not..
Earth work in excavation of foundation trenches or drains,in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches,levelling, dressing and ramming the bottom,bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete.(Payment to be made on the basis of measurement of finished quantity of work) a) With earth obtained from excavation of foundation.
Labour for laying 150 mm to 200 mm boulder soling including rough `-- Do -- -- Do - without rolling but including ramming.
Cost of Stone Boulder 150 mm of N. Bengal variety delivered and stack at site
II) Cement concrete with 30 mm down graded shingles excluding shuttering (B) In ground floor (with N.B. Variety Stone metal)(a) (1:3:6) proporaton
Plum concrete work with 40% cement concrete with 30 mm down graded stone metal and 60% stone boulder of size 150mm and above,placed in position as directed excluding shuttering if any.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-in-Charge
Ordinary Cement concrete ( mix 1:1.5:3) with graded stone chips ( 20 mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes.24.423 (ii ) River Bazree
Reinforcement for reinforced concrete work in all sorts of structures including distribution of bar, stirups,binders etc.initial straightening and removing of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection complete as per drawing and direction.(a) For works in foundatio n, basement and upto roof of ground floor/ upto 4m i) Tor steel / Mild steel
125mm thick brick work with 1st class bricks in cement mortar(1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar, including rounding off corners or chamfering corners as directed and recking out joints or roughening of concrete surface.(ii) (a) with (4:1) cement morter 20 mm thick plaster 144.60 Sq.M 247.20 35745.12 (ii) (b) with (4:1) cement morter 15 mm thick plaster
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be corrected up to three decimals).d) Sal : Local.
Panel shutters of door and window, as per design (each panel consisting of single plank with out joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, panel rate of reduction of 20% will be made).(iv) 25mm.thick shutters with 12 mm. thick panel of size 30 to 45cm.
supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar , end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction . ( cost of concrete will be paid separately).(a) 40mm x 6mm, 250mm Length .
Anodise aluminium barred/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S.204/74 fitted and Fixed with cadmium plated screws:.(vi) 200mm long x 10mm dia. bolt.
Anodise aluminium Aldrop/Sliding bolts of approved quality manufactured form extruded section conforming to I.S. specifictation (I.S.2681/66) fitted and fixed complete.iii) 300mm x 16mm dia. Bolt
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S.230/72) fitted and fixed complete:.(a) With continuous plate base (hexagonal/round rod).(ii) 100 mm grip x 10 mm dia rod .
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S.205/66) and fitted and fixed with cadmium plated screws:.(iii) 75x 45 x 2.5 mm.
Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufactured fromrolled steel sections conforming to IS 7452-1974 with non-frictionprojecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening ifrequired, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match withexisting surface complete in all respect excluding glazing.(Add extra @ 1.2 % for each additional floors upto 4th floor and @1.5% for each addl. Floor above 4th floor.)In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection ofworkmanship)Without integrated grill(b) Openable steel windows as per IS sizes with side hung shuttersand horizotal glazing bars. [The extra rate admissible for theopenable portion only]
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete (In all floors for internal wall & upto 6m height for external wall ).(ii) 4 mm. thick.
(a) Priming one coat on timber or plastered surface with synthetic enamel oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary.
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary.(b) On steel or other metal surface:
M.S. structural works in roof trusses with tubular sections conforming to IS: 806- 1957 & IS: 1161- 1958 connected to one another with bracket,gusset,cleats as per design,direction of Engineer-In-Charge complete including cutting to requisite size. fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814- 1957 haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section. consumables such as electrodes, gas and hire charges of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc.(Payment to be made on the basis of calculated weight of structural tubular members as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with the weight of finished structural members. The rates are considere d for a height of erection 8m./ 2nd. floor leves from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initial 8m. or part ther of.
Galvanized corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugaion minimum side lap. ( payment to be made on area of finished work). (GCI sheet to be supplied by contractor). .(i) in Roof:-.(b) With 0.63 mm.thick sheet.
Wooden eaves board as per design, fitted and fixed complete:In ground floor
Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping)(A) 300 mm lapping each way
Galvanised iron sheet eaves gutter fitted and fixed withnecessary 50 mm X 6 mm M.S flat bar clamps bent to design,bolts, nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping)
Ceiling of commercial ply as per design fitted and fixed complete (excluding the supporting frame work but including…
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. and cutting trenches in any soil through masoury concrete structures etc. if necessary and mending good damages including jointing with jointing materials (Spun yarn, valamoid / bitumen/M.seal etc) complete.
Supplying and laying true to line and level vitrified tiles ofapproved brand (size not less than 600 mm X 600 mm X 10mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tilesusing cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stonefloor/Mosaic etc without any backing course) laid afterapplication slurry using 1.75 Kg of cement per sqM belowmortar only, joints grouted with admixture of white cementand colouring pigment to match with colour of tiles / epoxygrout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water andpolishing the tiles using soft and dry cloth upto mirror finishcomplete including the cost of materials, labour and all otherincidental charges complete true to the manufacturer'sspecification and direction of Engineer-in-Charge. (Whitecement, synthetic adhesive and grout material to be suppliedby the contrr]e)
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.06 MB
Tendernotice_2.pdf
PDF • 2.85 MB
BOQ_2380255.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid