Rewari PHED No. 1
Designing, Constructing, Erection, Testing and Commissioning of 24 MLD Primary Treatment with Primary Clarifier and Tertiary Treatment Plant (TTP) with Disc Filters and Chlorination, with three month trial run period ,Operation and Maintenance for a
2026_HRY_494907_1
20266C845255 7D76 4878 B0F0 C15FB1EAD245579PUH
Open Tender
Civil Works
Works
365 days
Rewari
2 documents required · 2 mandatory
₹20,000
₹52.9 L
Yes
5 Jan 2026
5 Jan 2026
28 Jan 2026
5 Jan 2026
27 Jan 2026
5 Jan 2026
5 Jan 2026 - 7 Jan 2026
Supply , Installation, Testing , commissioning of Ultrasonic Level Sensors/ Flow Meters having measuring range of .1m to 3m with Electrical Panel, MS mounting of 8mm thickness sheet, Epoxy Painted and Calibration with Internet Optical Fibre Connection, Transfer to required websites (HPCB, CPCB, PHED and other mandatory web portals) and all associated works , complete in all respect upto the satisfaction of Engineer in Charge: Ultrasonic Flow meters at Outlet Channels to both STPs
Supplying, erection, testing and commissioning of submersible motor pumping set non clog for Sludge having head 10.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect( 95 m3/H@ 10 MWC) 4(2W plus 2S) For primary Sludge
Providing, Installation, Testing and Commissioning of Twin Lobe Air blowers with motors and Acoustic Casing of Capacity 1950 m3/ H @ 0.6 Kgf/cm2 for Aeration in MBBR reactors (2W plus 2S) including Mountings, base Frame , Spares and all realed civil works
Supplying, erection, testing and commissioning of submersible motor pumping set non clog for Sludge having head 10.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect 3 Nos( 166 m3/ H @ 10 MWC) for RAS
Supplying, erection, testing and commissioning of submersible motor pumping set non clog for Sludge having head 10.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect( 125m3/H@ 10 MWC) 2W, for SAS
Supplying, erection, testing and commissioning of submersible motor pumping set non clog for Sludge having head 10.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect( 170m3/H@ 10 MWC) (2W plus 2S), for RAS
Providing, Installation, Testing and Commissioning of Twin Lobe Air blowers of Capacity 4000 m3/ H @ 0.6 Kgf/cm2 for Aeration in SBR reactors (2W plus 2S)
Providing, Installation, Testing and Commissioning of Dissolved Oxygen Meter with 2 Probes , each in SBR Aeration Tanks with LED Display , Electrical Panels, Mounting and all related works
Supply, Installation, Testing and Commissioning of Rotating Disc Filters of Size and MOC as per The Specifications of the DNIT
Supply, Erection, Installation, Testing and Commissioning of Laboratory Equipment , Chemicals and Glass ware as per Annexure A
Supplying, erection, testing and commissioning of submersible motor pumping set non clog for Sludge having head 10.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect (105 m3/H@ 10 MWC) 3(2W plus 1S) For Thickened Sludge from Sludge Sump to Centrifuge
Supply, Testing, Jointing, Commissioning of Cables of Required Sizes as per the Estimate attached with in Annexure B
Providing , Fixing, Installation, Jointing, Testing of Main Header , MS Pipe, Epoxy Painted 400 mm id, 12.7 mm thickness, Schedule 40, for Header Line of Air from Blowers to SBR Tanks
Supply, Installation, Testing and Commissioning of MCC Panels, Two no main Incomer, Two DG Set Incomer, 6 No forRaw Sewage lifting Pumps, 4 No for Blowers with VFDs, 3 No for IR Pumps, 3 SD for RAS Pumps, 4 No SD Panels for Primary Sludge Pumps,3 SD Panels for Surplus sludge pumps to Centrifuge, 2 Nos for Centrifuge or any other panel as per requirement and make as per the approved DNIT for MBBR based STP and MPS as PER Annexure C
Supply, Installation, Testing and Commissioning of MCC Panels, Two no main Incomer, One DG Set (850 KVA) Incomer, 4 No for Blowers with VFDs, 4 SD for RAS Pumps, 4 SD Panels for Surplus sludge pumps to Centrifuge or any other panel as per requirement and make as per the approved DNIT for SBR based STP
Supply, Installation , Testing and Commissioning of Sluice Gates of Size 1.2 m x 1.2 m with Manual hand Rotated spindle of 500 mm Diameter. The MOC of Sluice gates shall and Spindle shall be SS-304 and Rotating handle shall be made of MS (2 Nos at Upstream of Fine Screens and 2 Nos at Downstream of Fine Screens)
Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 18.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS304, 8mm thickness guide Pipes, SS-304 Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect( 1200 m3/ H @ 18 MWC)
Providing , Installation, Testing and Commissioning of SS-304- Guide Pipes for Effluent Pumps, SS-304 lifting Chains for Effluent Pumps- SS-304 Guide Pipes, Sh 40 S, Thickness 5.16mm / Weight/m-8.63 Kg/m- 65mm Nominal Bore, 10m for each Pump/ 5 No pumps, Chain SS-304, 12mm Thickness, 12 m each Pump
Supply Installation Testing and Commissioning of Blowers with Motors for Existing Sludge sump 300m3/H @ 0.45 Kgf/cm2
Supply of Safety Equipments- 5 Oxygen Cylinders-3 Kg Portable Type, 15 Safety Belts, 15 Helmets, 15 Set of Safety Shoes, 5 Fire Extinguishers-2Kg Each, Oxidised Saftey Chain-50m, Rope 25 mm 100m, 15 Set of Satey goggles and gloves, Safety Jackets-15, PPE Kit-5
Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 V. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT`s) h) Metering set 60/5A/110V (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size l) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, Dc control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge` as per latest CPCB standards, with Graded Response Action Plan (GRAP) CPCB IV plus Emission Compliant- 500 KVA
Supply, Installation , Testing and Commissioning of Mechanical Coarse Screens in Existing Coarse Screen Channels with 20 mm bar(tapered) Spacing, 12mm bar thickness, designed for 50 % Clogging, SS-304 MOC , Bar Sceens to be of SS-316 MOC and Automatic Screen Removal Conveyor Belt mechanism with All Electrical Panels, cables, Civil works (1W plus 1S) as Per Specifications and make mentioned in the DNIT for 24 MLD average and 54 MLD Peak Flow. Make
Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 18.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS 304, 8mm thickness guide Pipes, SS-304 Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect( 1000 m3/ H @ 18 MWC)
Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 18.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like 304, 8mm thickness guide SS Pipes, SS304Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect.( 500 m3/H @ 18 MWC)
Supply, Installation, Testing and Commissioning of Gear Operated Flanged Sluice Valve adequate for Sewage Pipe Interal Diameter of 600 mm with MS Spindle and Circular Handle
Supply, Installation,Testing and Commissioning of Electromagnetic Double layered Flow meter suitable for 600mm id, Sewage carrying FDI pipe for Rising mains to Inlet Box and transfer of Flow meter data to Required web portals with dedicated Internet Connection through Optical Fibre Cable and Modem with all electrical cables, panel , with LED display. Flanges, Specials, Hodi/ Casing of Flowmeter shall be in scope of Works
Supply, Installation , Testing and Commissioning of Sluice Gates of Size 0.9 m x 0.9 m with Manual hand Rotated spindle of 900 mm Diameter. The MOC of Sluice gates and Spindle of shall be SS-304, The Thickness of SS-304 Sheet of Sluice Gate not less than 12mm and Rotating handle shall be made of MS (At Downstream of Receiving Chamber)
Supply, Installation , Testing and Commissioning of Geared Sluice Gates of Size 1.2 m x 1.2 m Opening with Manual hand Rotated spindle of minimum 900 mm Diameter. The MOC of Sluice gates and Spindle shall be SS-304 and Rotating handle shall be made of MS .The Thickness of SS-304 Sheet of Sluice Gate not less than 12mm (At Existing Manhole , Upstream of Receiving Chamber)
Supply, Installation , Testing and Commissioning of Mechanical Fine Screens in Newly Constructed Fine Screen Channels with 6 mm Spacing , 2mm bar thickness , MOC of screen mat SS-316 and Automatic Screen Removal Conveyor Belt mechanism with All Electrical Panels, cables, Civil works (1W plus 1S) as Per Specifications and make mentioned in the DNIT for 24 MLD average and 54 MLD Peak Flow. Make
Supply, Installation , Testing and Commissioning of Mechanical Degrittors with Agitators and Srew Grit Removal Mechanism in Newly Constructed Grit Channels (7.5 m x 7.5 m x 1.0 m SWD plus 0.3m FB) auto grit removal mechanism with All Electrical Panels, cables, Civil works (1W plus 1S) as Per Specifications mentioned in the DNIT:
Providing, Installation, Testing and Commissioning of Decanter type Centrifuge Machines with Solids handling Capacity Upto 600 Kgs/Hr, able to achieve 20% Consistency in Dried Sludge with 90-95 % Separation Efficiency with Operating Speed of 3000-3200 rpm and 30-35 KW Motor 3 (2W plus 1S). The Centrifuge machines shall be Supplied and Installed with all Accessories from Poly dosing Pumps, Outlet solids funnel, with necessary spares such as Intermediate kit Conveyor bearings, main bearings, lubricants , Cables, Panels and all associated works hereto to the Satisfaction of Engineer in Charge
Supply, Installation , Testing and Commissioning of Wall mounted submersible Mixers with Chain Pulley Arrangement for maintenance (5 KW each) with Column Profile, SS-304 , 100 Kg Capacity Crane with Winch, Bottom Fixation of Crane, Cable Grip, Cable Clamp, Leak sensor, Motor Bracket Spares, Electrical Panels, cables, Civil works (1W plus 1S) as Per Specifications of DNIT.
Designing, providing, fixing, commissioning and testing of Online Analyzer for Chlorine, auto switch over chlorination system, Chlorine Dry Scrubber, Auto shut off Valve, Chlorine Gas Cylinder and Chlorine gas leak detector and all other works contingent thereto(Ch:orinator), As per latest approved Technical Specifications from Head Office vide letter No-23070-23142 with reference to IS code 10553(2)-1983 a.
Repair of Secondary Clarifier Rake Mechanism-rubber Scrubber, SS angles and Clarifier Rake Mechanism, Supporting SS- angles, repair of existing weirs and MS bridge motor as per the scope of work defined in the DNIT and necessary for smooth functioning of Secondary clarifiers.
less credit of existing Mechanical Coarse Screens (2 Nos) at MPS
less credit of Sluice Gates at Receiving Chamber (1 Nos), Coarse Screens (2 Nos)
less credit of Raw Sewage Submersible Pumps: 1. 20,000 LPM Pumps 2 Nos, 10000 LPM 1 No, 5000 LPM Pumps 2 Nos.
less credit of existing rising mains of DI K-9 400 mm
less credit Mechanical Fine Screens-3 Nos. 1 No in 8 MLD STP, 2 Nos in SBR based STP.
less credit of Degritters 2 No of Degritters in Both STPs
less credit of 6 No. Sluice Gates at Fine Screens and Grit Mechanism.
less credit of existing Anoxic Mixer 1 No.
less credit of existing Decanters SS-304, Weight of 1 No Decanter 2000 Kg and Weight of 2 No Decanters 4000 Kg RAS pump 4 nos. and SAS pumps 4 nos.
less credit of IR Pumps 3 No Submersible Sewage Pumps of 350 m3/h @ 10 MWC
less credit of MBBR Blowers 3 No Blowers and Motors of 1900 m3/H and Induction Motors 60 HP
less credit of SBR Blowers 3 No Blowers of 4000 m3/H and Induction motors, 120 HP
less credit of LT Panels 8 MLD panels with Blowers and Raw Sewage pumps etc.
less credit of LT Panels 16 MLD panels with Blowers and Raw Sewage pumps etc.
less credit of MS Air header Pipe 400 mm, (SBR)
Primary Clarifiers Rake Mechanism, Providing, Installation, testing and Commissioning of SS 304 Sludge Scrapper for 29.2 m ID Clarifier and MS Scrapping half bridge with not less than 1200 mm walkway with MS rail 10 mm thick for motor bridge and Related Electrical, Mechanical and Civil Works. The rake mechanism shall be equipped with skimming mechanism at the top with MS half bridge, MS rails, SS-304 V shaped Weir, SS -304 Central Column. Diameter of rake mechanism shall be as per design requirement. The submerged part of the rake mechanism shall be of SS-304 and Half bridge shall be of MS sheet and angles not less than 12 mm thickness. The scope includes panels, cables of required sizes and any piping not mentioned but required for smooth functioning of clarifiers
HT panel-Design, Providing, Installation, Testing and Commissioning of Indoor type floor Mounted Extendable type, Metal Clad, totally enclosed, 1 Breaker Panel 11 KV, with GO Switch, 3 Phase, effectively earthed, short circuit withstand capacity of26.3 KA for three Seconds. Vaccum Circuit breakers (3 Nos), Earthing trolley as per IS: 13118, Panel Board single break, trip free, motorised spring charged with electrical closing arrangement with horizontal draw out and horizontal isolation type VCB with mechanical ON/OFF indicatorand trip device , 4 NO plus 4 NC auxillary contact complete with self contained, fully interlocked, rackrack in and rack out mechanism as per IS 13118, as ammendedupto date specifications, with 800 A Capacity aluminium bus bars and bottom entry gland plate suitable for 3 x 150 sqmm, 11 KV XLPE cable ( 1 No Incomer VCB and 2 No Outgoing VCB - for two transformers Each) Existing 1 No Transformer of 650 KVA and 350 KVA on One HT Panel) and (Existing 350 KVA and New 600 KVA Transformer in Second HT panel)
Providing, Installation, Testing and Commissioning of Dissolved Oxygen Meter with 3 Probes , each in Aeration Tanks with LED Display and Electrical Panel with Cables of required size.
Supply Installation Testing and Commissioning of EOT crane 3 Tonne Capacity, 14 m Span, with SS Chain Placed above the Centrifuge for Maintenance of Machines. The MS gantry to be not less than 12mm thickness, with Electrical fittings, cables , Panel as per the requirement to the Satisfaction of Engineer in Charge.
Re-barring and re-grouting of 12 mm steel bars with DE-Walt pure 150-Pro Chemical, in walls for strengthening the Stair Case of MPS and Coarse Screen Channels- 100 mm C-C and 6 Inches Deep in both faces of RCC walls (Note: The successful bidder shall prepare Design and Drawings of Re-barring and re-grouting work w.r.t. stability of existing RCC structures and proposed structures after works done and design and drawings of the same shall be approved by SE, Rewari before execution the work at site.) rates to be quoted without steel and C.C.
Re-barring and re-grouting of 12 mm steel bars with DE-Walt pure 150-Pro Chemical, in walls to facilitate the raising of Existing RCC tank walls- 200mm C-C and 6 Inches Deep in both faces of RCC walls (Note: The successful bidder shall prepare Design and Drawings of Re-barring and re-grouting work w.r.t. stability of existing RCC structures and proposed structures after works done and design and drawings of the same shall be approved by SE, Rewari before execution the work at site.) rates to be quoted without steel and C.C.
Rebarring and regrouting of 12 mm steel bars with DE-Walt pure 150-Pro Chemical, length of grout rebar each bar shall be 6 inch deep minimum in walls for strengthening of Walls of Collection Tank , 0.5 m C-C along the surface (Note: The successful bidder shall prepare Design and Drawings of Rebarring and regrouting work w.r.t. stability of existing RCC structures and proposed structures after works done and design and drawings of the same shall be approved by SE, Rewari before execution the work at site.) rates to be quoted without steel and C.C.
Supply, Fabrication, Testing and Commissioning of Aeration Grid in Existing Anoxic Tank( To be Converted to Aeration Tank) as per design apporved by SE, Rewari.
Supply, Fabrication, Jointing, Testing and Commissioning of MS pipe of Diameter 150 mm Sh-80 and thickness 10.97 mm minimum with Epoxy Paint and Jointing to the Existing Header Air Pipe Line complete in all respect for Aeration Grid in MBBR tank-1.
Providing, Installation, Testing and Commissioning of SS-304 Aeration Grid, Decating Mechanism , actuating gates, Actuating Valves for Air, RAS , SAS, Raw Sewage Pumps and SCADA with Synchronization to SBR mechanism as per the Design and Cycle duration from Service (Technology) Provider along with Computer Hardware , i7 Processor, 512 GB SSD, 2 TB Hard disk, 32 GB RAM, UPS 600-1000 VA with a power factor of 0.7-0.8 , 32 Inches Smart LED Screen and necessary Software, Inverter 1000 VA with battery backup for SCADA room
Supply, Fixing, Erection and Testing of FRP Cable Trays for Cables of various sizes at different locations of STP, Thickness minimum 5mm 300 mm Perforated - 300 m, 200 mm Perforated -400m, 150 mm Perforated -400m, 100 mm Perforated-300m and as per site requirement and satisfaction of Engineer in charge.
Operation and Maintenance of MPS, Common Primary treatment units, 8.0 MLD MBBR based Upgraded STP, 16 MLD SBR based STP, Common TTP ,Effluent Pumping Machinery and Effluent Rising Mains (14 Kms Aprox-HDPE) , all electrical equipment, street lights, Premises lights, landscaping, Flow meters , camera, required Internet as per O n M terms and Conditions attached with DNIT 1st Year Operation after Trial run, during Defect Liability period (Only Operations)
Operation and Maintenance 2nd Year
Operation and Maintenance 3rd Year
Operation and Maintenance 4th Year
Operation and Maintenance 5th Year
Operation and Maintenance 6th Year
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
HSR Itmes
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
BOQ_573367.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .