Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 CrAccepted-AOC | ₹22.2 Cr | L1 | Accepted-AOC RESPONSIVE |
| 2 | L2₹22.4 CrRejected-AOC | ₹22.4 Cr | L2 | Rejected-AOC RESPONSIVE |
Tender Value
₹22.7 Cr
EMD Value
₹45.4 L
Closing Date
14 Mar 2026, 12:30 pmClosed
EXECUTIVE ENGINEER
E. E. PROVINCIAL DIVISION NO. 1 PWD B AND R PATIALA
Construction of Entry Pavilion Front Boundary Wall Satsang Hall and Covered Corridor connecting Main Mandir Bhawan alongwith Renovation and Repair of Areas Surrounding Rajrajeshwari Mandir at Shri Kali Mata Mandir Patiala Phase II
2026_CEPW_161660_1
Bid No. 101 Dt. 19.02.2026
Open Tender
Civil Works - Buildings
210 days
PATIALA
Please refer Tender documents.
3 documents required · 3 mandatory
₹50,000
₹45.4 L
Yes
17 Apr 2026
21 Feb 2026
14 Mar 2026
21 Feb 2026
14 Mar 2026
21 Feb 2026
BUILDING BLOCK : Earth work in excavation by manual or mechanical means in foundation trenches, rafts, basements, or drains in all sections and widths including open timbering over areas requiring struting ,shoring etc. complete where ever necessary and including required dewatering & dressing of sides and ramming of bottoms, lift up to 1.5 m including getting out the excavated soil and disposal of surplus excavated soil, as directed for all leads in all type of soil. (Excluding rock/boulder)
Back Filling with available earth within site in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or steel rammers & rolling every third & top most layer with power roller of minimum 8 tonne & dressing up in embankments for roads, flood banks, marginal banks & guide banks etc to achieve minimum 95% Proctor density for all leads & lifts.
ATT: Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm.
PCC WORK: P/L cement concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) M10/M15
REINFORCED CEMENT CONCRETE: Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. M-25 Grade (with minimum of 360/385 kg of cement per cu meter) Super Structure
Reinforced cement concrete M-25 mechanically batchmixed using batch type concretemixer asper IS:1791and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1km lead(note: whereconcrete mixer is already included in the rate the same shall be deducted )
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Centering and shuttering for columns (Square or rectangular or polygonal in plain)
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete
Extra Rate for Steel used by primery prducer in integrated plant
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
20mm thick cement plaster 1:4 in two coat work
12.5 mm thick cement plaster 1:4
10mm thick Cement Plaster 1:3
Flooring Sub Base Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
Water proofing treatment of Roof Slab with High performance cementitious two component product, consistingof apowder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex-PackagingSize:12 .5kg(7.5kg powder + 5 kg polymer) / equivalent water proofingSolution ). The slurry thus formed by mixing the two, is tobeappliedonnewroofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. Theworkshallbecarried out all complete as per specification and the direction of the Engineer-in-charge.
Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material
VIP ENTRANCE & TOILET :_Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). Size 800x800 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm
SATSANG HALL:_Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Darshan Pavalion Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for seprately (iii)White sand stone- exposed face fine dressed with rough backing. (C) 30mm thick VIP Entrance & Toilet
Satsang Hall
Darshan Pavalion
Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Preparation of plastered or concrete surface for painting (including sand papering the surface) using Acryllic Wall Putty by applying two or more coats to get required finish including priming coat to make an even surface before applying Acrylic wall putty on new plastered surface.Complete as per specifications
Providing & applying heritage granual homogeneous wall finishing system from Bake lite Coating & Paints Pvt. Consisting of two component system of dry Granual (25 kg/pack) made of 92% silice particle, coated with fader esistant pigmant sand 100% acrylic co-polymers bondinga gent (5 ltr pack) with the applied thickness of coating being between 0.8 to 1.2 mm to be applied in single coat on acured level smooth plastered, asper the shade combination approved and as per manufacturer specification, all complete inclusive of primer on the base.
P.O.P. FALSE CEILING/Gypsum/Grid Providing / Fixing in position False ceiling over G.I. metal frame work of approved. quality and wiremesh as per detail. Providing and fixing in position multilevel P.O.P. ceiling suspended on GI frame work in design as shown in drawing. The GI frame work consist of perameter channel of size: 27mmx.5mm.Intermidiate channel of size 45mm x.5mm thick. Ceiling section of .55mm thickness. Note : no extra charge shall be given for providing cutouts for light fittings, grill diffusers, slits or for making any grooves if required. Plan area shall be measured for billing. Cost to be inclusive of making coves, recesses & cornices.
GRC DOME ABOVE ENTRANCE LOBBY Providing of Glass Reinforced Concrete (GRC ) elements in Approved size, Pattern, Design, standerd thickness design elements is 25-30 mm, thick have weight approximately between 3-4 kg per sqft, The GRC should be made from '53 Grade' white Portland cement manufactured by "JK Cement" or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by made in JAPAN (Nepon) or equivalant, Super Plasticizers manufactured by BASF" or equivalent, Polymers manufactured by 'BASF' or equivalent. The material casting should take place in Synthetic Rubber/FRP Mould manufactured by 'Reckli or Equivalent
GRC DOME ABOVE SATSANG HALL Providing of Glass Reinforced Concrete (GRC ) elements in Approved size, Pattern, Design, standerd thickness design elements is 25-30 mm, thick have weight approximately between 3-4 kg per sqft, The GRC should be made from '53 Grade' white Portland cement manufactured by "JK Cement" or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by made in JAPAN (Nepon) or equivalant, Super Plasticizers manufactured by BASF" or equivalent, Polymers manufactured by 'BASF' or equivalent. The material casting should take place in Synthetic Rubber/FRP Mould manufactured by 'Reckli or Equivalent
FLUSH DOORS with Door Frame Providing and fixing 40mm thick solid core homogeneous flush door shutter Interior WWR grade-IGSB, with ISI mark as defined by IS:12406-1988 & BS:1142:1989 IGSB. Rate to be quoted with the following finishes 4mm thk veneer/laminate on both sides with grooves & panelling as per design. All Blocks
Providing and laying tiles in cladding/ dado/ jamb/ soffit/ cill of uniform thickness, size, shade and pattern as approved by Architect/Project Manager laid with rich cement slurry over a bedding plaster of 6mm (avg.) thick cement mortar 1:3 (1 cement : 3 fine sand) including the cost of 12mm average thick rough base plaster of mix 1:3 (1 cement : 3 coarse sand), providing grooves using 2/ 3mm PVC spacers and grouted with tile groute (Bal grout) of matching shade of tile, cutting, curing etc. complete in all respects as per drawing. VIP Entance & Toilet With 600*1200mm Vitrified Tiles
MAA KALI COURTYARD: Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Dismantling concrete (Cement concrete plain 1:4:8 )
Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling of brick work in cement sand mortar / lime mortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 metre (By Mechanical Means)
Cement concrete (1:3:6) Mixing by mechanical means using concrete mixer volumetric type
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
Waterproofing of wet areas ( Concrete/ Masonary Surface ) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating ( DR. FIXIT FASTFLEX / Equivalent ) to provide tough film build-up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface prepration and cleaning, washing and removing dust,dirt and loose particles from concrete / masonary surface complete in all respects
Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre.
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases.
12.5 mm thick cement plaster 1:4
Flooring Sub Base Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
DISPOSAL OF DEBRIS Earth,Surkhi, Sand, Earth, Fly Ash, Bajri, Ballast, Stone boulders, Kankar and building rubbish, Earth 0.0-5km
Grip railing Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect
MAA KALI COURTYARD: Providing opening with dismantling existing structure including making frame in Dholpur stone and making Arches as per existing opening and finished neat complete.
Supply of pre-fab polymer concrete Multiline channels conforming to EN 1433 standards. The Channel should have V-shaped profile, tounge and groove jointing arrangement, in-built galvanised steel edge rail, with in-built slope along the complete length of the channel, and polymer concrete channels to be made of zero water absorbtion, of density being 2.1 - 2.3gm/cm3, with surface roughness of aprox 25 µm complete with Stainless Steel Linear U profile grating having load class B125 including all necessary accessories like end caps, outlet units etc. as required as per site and the instructions of the engineer - in - charge for following sizes: Channel Size 1000/500 x 200 x 150-250 mm (L x W x H),Grating Size 1000/500 x 188 x 25 mm (L x W x H) Make: ACO or approved equivalent
Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : With combination of White Marble & Aaroli Stone as per pattern shown in Drg./Details (Pattern no. Detail-2)
With combination of White Marble & Aaroli Stone as per pattern shown in Drg./Details (Pattern no. Detail-4)
White Marble as per Pattern no.5
20mm thick shot blasted Aaroli stone
20mm thick Honed finish Aaroli stone groove cut
Marble work of thickness 18-20 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to backing by means of cramps, which shall be paid for separately).Aroli stone shot blasted of approved sizes as per details/drg.
Providing and laying of Granite /stone of various width for Coping / Sill / Treads of steps and other area as specied by Landscape Architects, sizes as indicated in the drawings and as per Approval, set in cement mortar 1:3 with Cebex 112 mixed in cement mortar as per manufacturers specification. The rate quoted shall including making holes for fixing accessoris, making grooves as shown in drg/details and grooves finished / pointing neatly with EPOXY GROUTS to match the colour of stone or approved shade, Edge chanphering as per drg, keeping the completed granite covered with Plaster of Paris for protection and cleaning of the same till handing over, including cost of materials, labour, Wastages, Tools & Tackles, cleaning, curing, house keeping etc., complete. all as per specifications, directions & instructions of Engineer-in-charge. including working at all heights with lead & lift.etc.complete.Aroli stone shot blasted of approved sizes as per details/drg
Stensils Paint Work In courtyard corridor & Ceilings
GATE & KUND REPAIR: Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Reinforced cement concrete M-25 mechanically batchmixed using batch type concretemixer asper IS:1791andvibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe500gradeasper IS1786-2008) , forR.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing, fabricating, CARVING FOR GATE as per existing design and fixing stone on walls with necessary stainless steel cramps, copper pins as per design / drawing including making holes for fixing cramps and filling the same, silicone / epoxy grouts filling in joints of stone, hoisting, scaffolding all as per approved sample and finished neat complete. 30mm thick Dholpur stone on Arches
Providing, fabricating and fixing in position Hot-dip galvanized steel work for KUND RAILING and other works in single or built-up sections using MS pipes, angles, Tees,MS hollow tubes, squre bar, channel, plates, special shape ms members etc. fabricated to required sizes and shapes and installed in position with necessary hold fast / fixing arrangement including all incidental operation like cutting, welding, grinding, bending, drilling, hoisting, scaffolding as required other operations, all incidental work complete as per drawings & directions of Engineer-in-charge.(Drg. no....... Detail no.......)(Vendor shall prepare shop drg. for approval from Landscape Architect befor execusion the work)
Providing and filling light weight concrete over slab of density 600kg. /cum. laid to slope as per direction of Engineer-in-charge including crushing, consolidating, compacting etc. complete.
Providing and fixing WET CLADDING FOR GATE with 30mm thick ROUGH FINISH DHOLPUR STONE with (machine cut edges) of uniform colour and approved size , fixed with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per details / drawing and direction of Engineer-in-charge.
Providing and fixing Dholpur stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab etc complete as per details/drg and as per approved sample.
LANDSCAPE WORK: Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Excavation in Soil (any type) using Hydraulic Excavator CK 90 Excavation with hydraulic excavator of 0.9 cum bucket capacity including cutting trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lift and combined lead up to 60 mtr.
Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications
Cement concrete 1:3:6 mixing by mechanical means using concrete mixer volumetric type
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth FOOTING AND WALL
Pump charges
Extra for Concrete Batch Mixing
Mild steel requirement for RCC work where not including the complete rate of RCC including bending, binding and placing in position complete in all respects. Up to 20mm dia bars
Extra Rate for Steel used by primery prducer in integrated plant
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Centering and shuttering for arches of varandah, door and windows openings.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer
Grip railing Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect
Providing, hoisting and fixing in super structure for first storey precast reinforced cement concrete in small lintels not exceeding 1.5m clear span including the cost of required centring & shuttering, cost of 1:2:4 hand mixed (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal-size) but excluding the cost of steel reinforcement.(Qty of each unit shall not exceed 0.06cum)
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required
Plastering on underside of ceiling 10mm thick cement plaster 1:4
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Makrana, Doongri, Adanga viened and chack Doongri with grey stretches. Slabs sizes above 0.50 Sqm
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand),including making the necessary chases.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Taking out existing CC interlocking paver blocks from footpath/ central verge/pavement, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in- Charge.
LANDSCAPE WORK: Providing and laying of Granite /stone of various width for Coping / Treads of steps and other area as specied by Landscape Architects, sizes as indicated in the drawings and as per Approval, set in cement mortar 1:3 . The rate quoted shall including making holes for fixing accessoris, making grooves as shown in drg/details and grooves finished / pointing neatly with EPOXY GROUTS to match the colour of stone or approved shade, Edge chanphering as per drg, keeping the completed granite covered with Plaster of Paris for protection and cleaning of the same till handing over, including cost of materials, labour, Wastages, Tools & Tackles, cleaning, curing, house keeping etc., complete. all as per specifications, directions & instructions of Engineer-in-charge. including working at all heights with lead & lift.etc.complete. 40mm Polished Dholpur stone
20mm Polished Kota stone
Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing.30mm thick Dholpur stone
Providing, fabricating and fixing in position SS Wire of 10mm as per design/drg including cutting, bending, welding and ncessary hardwares etc. complete.
Marble stone flooring with stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : With combination of 40mm thick KOTA STONE SHOT BLASTED 77% & WHITE MARBLE HONED 23% as per pattern shown in Drg./Details
40mm thick Kota stone shot blasted
20-25mm thick Kota stone shot blasted
With combination of 40mm thick KOTA STONE SHOT BLASTED 77% & Aroli stone HONED 23% as per pattern shown in Drg./Details
IN COVERED WALKWAYS : With combination of 20mm thick White Marble 77% & AAROLI Stone 23% as per pattern shown in Drg./Details
Providing and Applying DUCO Paint of approved brand and manufacture of required colour in two or more coats to give an even shade including preparation of surfaces and steel primer complete.
Providing, making, finishing column BASE in Dholpur stone as per design/drg. as shown in drg. including cement mortar, adhesive, moulding, champhering, polishing and all indentals complete as per approved samples.
Providing, making, finishing CORNICES at middle of the columns (allaround) in Dholpur stone as per design/drg. as shown in drg. including cement mortar, adhesive, moulding, champhering, polishing, SS CRAMPS, COPPER PINS, hoisting, scaffolding and all indentals complete as per approved samples.
Supplying and installation of seat as per design and approved sample amd finished neat complete. 50mm coping in AAROLI stone structre In Dholpur stone in cavers surfaces of size 2000mm Length x 600mm width x 750mm Ht.(As per drg.no.DR5DTMP10R0LD68)
Providing,fabricating and fixing in position ARCHES in Dholpur stone as per design/drg including necessary harwares, jointing, poining and finishing etc.compelete as per desing and finished neat complete.
Providing and applying 15mm waterproof cement plaster in cement mortar 1:4 (1 cement: 4 coarse sand) and adding cementious crystallisation based damp proof asmixture KMA (Krystol Mortar Admixture)@ 2% by weight of cement or other approved water-proofing agent as per manufacturer's specification , finished smooth in line,level and plumb including curing, scaffolding, hacking RCC surfaces, raking joints etc. complete at all levels as directed and specified and directed by Engineer-in-charge.
Supplying and laying Grass Track Grass Pavers,Green honeycomb panels with self anchoring pegs,made of high impact resistant HDPE.Each grass paver should be of 500mmx500mm X40 mm in height consisting of four floral shaped structure of 125mm open cell and nine round cell opening of 45mm dia.Each of the open cell are connected With a web like structure for strength and stability.Base of the panel is equipped with a slot opening for drainage and four round struts for anchoring purpose.The Grass Paver to have interlock system to lock each other.The Grass Paver should have compressive strength of minimum 150 tons/sq mt,capable to take the load of the fire tender.The panel should have high level of porosity greater than 90%,porous for Grass,shrubs and low planters.Laying to be done on 50 mm sand bed over well compacted subbase as per manufacturer specifications and directions of Engineer in charge.
Dismanting of existing structure and disposal of debris out of premises and stacking of serviciable materials and finished neat complate the dismantalled area as per finishe neat complate.Pucca structure (wall,column ,door ,jali ,gate window, roof , lighting , plumbing , tile , plaster stone electric, plumbing ,ac units )
Tin shade structure/ Minor structure (column ,door , jali, gate , railing , roof , lighting , plumbing , tile , plaster stone electric, plumbing ,ac units )
SIGNAGE: Preparing shop drawings of each signage element To do Template testing at site e.g flex/sunboard/vinyl /vinyl print etc.once shop drawings are approvedv Sizes/area to be verified at site wherever required e.g façade location ,glass panels,walls & flooring wherever required To do the prototype testing of each category of signage element at site Vendor shall verify the location/quantities with the site incharge at site for indoor/outdoor signages. To create production artworks based on the shared artwork guidelines .Artwork guidelines will be shared in editable PDF format .Signage vendor to export the same in the relevant production softwares(CDR,AI,EPS etc)and create all balance artworks accordingly. To get the approval on each shop drawing from the signage consultant. To get the approval on all the production artworks from the signage consultant. To share the power load of each category of signage elements/location with electrical contractor. To get the approval on material/colors/finishes by submitting the samples to signage consultant. To get the structural engineers approval on façade signage/totem/pylon from a certified structural engineer's approval. To share the equipments/accessories to be used for the installation of façade/totem/pylon. To share the safety compliances documents(e.g TPI of safety equipments to be used / insurance & medical fitness certifcates of the installation team). To get the approvals on fixing detail of all the signages types. To get the approvals on colour temperature of the led modules/burial light/focus lights to be used int signage elements etc. To share the rcc foundation drawing/structural engineer's approval of pylons/totems if that is in their scope. To share the pics of internal m.s structures primered & painted both. Vendor is responsible for storage of uninstalled signage elments at the site. To cover the signage elements wherever required to protect these from any damage till the handover. To submit certifications and warranties of certain items (eg.3m products/Led Modules/SMPS/PVD lab testing certificates)Totem Pylon Sign Finish : ACP cladded on metal frame 5500*1100mm
Temple Name Announcer Sign Finish : Aluminium Letters with PU paint 3240*1400mm
Main Temple Sign Finish : Aluminium Letters with PU paint 4200*1050mm
Archaway Sign Finish : Aluminium Letters with PU paint & Motif pattern to be Engraved with color filling 4700*360mm Type-1
Gate Number Entry/Exit Announcer Sign Type-2 Wall mounted
Security House Announcer Type-2A Wall mounted
Flag Sign Finish : Flex with UV print Type-1 2100*700mm
Parking bay Graphic Announcer Sign Finish : Epoxy Paint 5000*2500mm
Utility Sign (Wshrooms Announcer Sign)
Utility Sign (Cubical Number Sign)
Utility Sign (Washrooms Graphic Announcer Sign)
Prashad Announcer Sgin
Utility Sign (Lift Car Number Announcer)
Facility Announcer Sign (Primary) Type-3 Wall mounted 700mm*225mm
Facility Announcer Sign (Primary) Type-7 Wall mounted 300*330*150mm
Facility Announcer Sign (Secondary) Room & Shaft Finish: Corian with UV printing Type-3A 200*200mm
Staircase Announcer Sign Finish: Corian with UV printing Type-3B 200*200mm
Facility Announcer Sign (Temple Name Announcer) Finish: Corian with UV printing Type-4
Guest Room Number Announcer Sign
Orientation / Information Pylon Finish : Corian with engraving .Orientation Map to be made up with Metal Sheet with Etching / Engraving Type-1 Floor mounted 3100*2000mm
Orientation / Information Sign Type-1 Wall mounted
Directional Sign Projecetd Type-1 Wall mounted 450*250mm
Interpretation Sign (Kali & Rajrajeshwari Temple) Type-1 floor mounted
Courtesy Sign Finish: Corian with UV printing Type-1 320*320mm
DOs and DON'Ts Sign - Type-1 Finish: Corian with UV printing 320*320mm
DOs and DON'Ts Sign - Type-2 320*320mm Type-1
DOs and DON'Ts Sign - Type-3 320*320mm Type-1
Statutory Sign (Incase of fire do not use lift) 320*320mm Type-1
EMERGENCY SIGNAGE Emergency Assembaly Area Announcer Sign Finish : SS structure with 3M Retroreflective content Type-1 Floor mounted
EMERGENCY SIGNAGE Fire Exit Announcer Sign Type-1 Wall-mounted
EMERGENCY SIGNAGE Fire Exit Announcer Sign Type-1 Ceiling Hung
EMERGENCY SIGNAGE Floor level announcer Staircase Landing Type-1 Wall graphic
EMERGENCY SIGNAGE Emergency Evacaution plan Sign Type-1 Wall mounted
EMERGENCY SIGNAGE Fire Door Info Sign Type-1 Door mounted
EMERGENCY SIGNAGE FHC Announcer Sign Type-1 Door mounted
RPwD SIGNAGE Facility Announcer Sign Finish: Corian with UV printing Type-1 Wall mounted
RPwD SIGNAGE Utility Sign (Wshrooms Announcer Sign) Type-1 Wall mounte
RPwD SIGNAGE In case of Emergency Pull Cord Sign Type-1 Wall mounted
RPwD SIGNAGE Lift Jambs Sign Type-2 Wall mounted
RPwD SIGNAGE Ramp Announcer Sign Type-1 Floor mounted
RPwD SIGNAGE Fire exit sign Type-1 Wall mounted
SANITARY INSTALLATIONS & INTERNAL WATER SUPPLY & SEWERAGE: Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect.
Providing and fixing jet spray with 2'-6" long PVC pipe. With C.P. Brass nut
Providing and fixing Stainless steel health faucet complete in all respect.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. size 44cm dia (under counter round)
Providing and fixing in position C.P brass basin mixer without pop-up waste system with 450 mm long flexible hose of approved make (to the approval of Engineer-in-charge) complete in all respect.
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. Sink with drain board overall size 1070x464mm bowl size 430x355x200mm and waste coupling
Providing & fixing in position C.P brass Sink mixer swivel spout (Wall mounted) of approved make (to the approval of Engineer- in-charge) complete in all respect.
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 600mmx450mm
Providing and fixing in position Hand dryer of Jaquar- Code No. HDR-SAP-M06ACS or Equivalent model from Parryware / Hindware, made of AISI 304 stainless steel and satin finish etc., complete all as specified and directed by EIC
Providing and fixing in position C.P. brass overhead shower round or square 1 flow without shower arm with 15mm i/d inlet of approved make (to the approval of Engineer- in-charge) complete in all respect. CP Brass rain Fall Shower without arm 6" square
Providing and fixing in position C.P. brass overhead shower arm chrome round or square with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect. CP Brass rain Fall Shower arm 24" length square chrome
Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer- in-charge) fixed in with rawl plugs and C.P brass screws complete in all respect. CP brass Acrylic Shelf size 560mmx130mm
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P. brass towel Rails size 15mm dia 610mm long
C.P brass towel ring
Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock long nose/ long body foam flow without flange
C.P. brass Bib cock foam flow without flange
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P.brass 15mm Angle valve without flange
C.P.brass 20mm concealed stop cock with flange
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect.
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge) with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. brass liquid soap container
Providing & fixing in position C.P. brass tube connection braided SS304 of approved make (to the approval of Engineer-in-charge) complete in all respect. CP Brass Flexible tube Connection Braided SS304 of size 15mm x 900mm long
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories: C.P. brass towel rack 600mm long with lower hangers
Providing and fixing in position vitreous Chinaware white Senso urinal size 37 x 39 x 61 cm of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm complete in all respect.
Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. Vertical type 25 litre capacity water heater
Providing and fixing divertors of approved make (to the approval of Engineer-in-charge Single lever concealed divertor of bath and shower system (with body and upper part)
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks
Providing and fixing in position automatic brass Ball Cock in tanks. Plastic Ball Cock with rod and Plastic Ball 25mm i/d
Construction of Plateform for Water Storage Tanks
Providing and fixing CPVC Ball Valve 25mm complete in all respects.
Providing and fixing CPVC Ball Valve 32mm complete in all respects.
Providing and fixing CPVC Ball Valve 40mm complete in all respects.
Providing and fixing CPVC Union 25mm complete in all respects.
Providing and fixing CPVC Union 32mm complete in all respects.
Providing and fixing CPVC Union 40mm complete in all respects.
Providing and fixing CPVC Tank Nipple 25mm complete in all respects.
Providing and fixing CPVC Tank Nipple 32mm complete in all respects.
Providing and fixing CPVC MTA 25mm complete in all respects.
Providing and fixing CPVC MTA 32mm complete in all respects.
Providing and fixing CPVC MTA 40mm complete in all respects.
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. CPVC SDR 11 pipes & fittings 20mm o/d
CPVC SDR 11 Pipe & fitting 25mm o/d
CPVC SDR 11 Pipe & fitting 32mm o/d
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition Size 75 mm x 75 mm
INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. SDR 11 CPVC pipes & fittings 20mm o/d
SDR 11 CPVC pipes & fittings 25mm o/d
SDR 11 CPVC pipes & fittings 32mm o/d
SDR 11 CPVC pipes & fittings 40mm o/d
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. Through wall 22.86 cm thick
Providing and fixing in position single socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B 110mm o/d SWR UPVC pipe line laid complete
90mm o/d SWR UPVC pipe lines laid complete
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm o/d pipes Vent Cowls
Elbow 90 Degree (All side socketed)
Coupler
P Trap/Floor Trap 110mm x 110mm
P Trap/Floor Trap 110mm x 75mm
Single Y-Junction with door
Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) 110mm o/d
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge) including carriage complete in all respect. Water Cooler Full Steel Body 150/150 ltr without Stablizer. (for MCH wing)
Construction of Foundation for Water Cooler including RCC Slab complete in all respects.
Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
AUTOMATIC VOLTAGE STABLIZER Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- Automatic Voltage Stablizer 5 KVA.
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement,R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal
Providing and fixing in position PVC gully traps 100mm fixed in cement concrete 1:4:8 complete with SFRC cover with frame weighing 7.26 Kg. 300mm x 300mm including Grating complete in all respects.
Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metre for sewers and manholes to full depths as shown in drawings, including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of works upto 15 metre, for all works other than connections to complete in all respects. For depth not exceeding 2 m. below Ground level For all classes of soil except rocky
Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base.
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. 110mm o/d pipe
160mm o/d pipe
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 90x150 cm and 120 cm deep
Foot Rest for Manhole. Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda Sewer connections upto 300 mm id
Providing and installing in position of domestic water pressure boosting pump of approved make (To the approval of Engineer- in-charge) including all pump accessaries but excluding cost of G.I pipe & specials complete in all respects. Pressure pump of 0.65 HP with 2700 LPH, 37meter head with SS pump & 19 litre capacity Tank
Fire Fighting System: Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 6 Kg. Capacity
Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 4.5 Kg. Capacity
Air Conditioners: P.I.T.C. of 5 star Invertor Split Type AC with remote control, R-32 Gas, fitted with return cooled rotary Compressor operating on latest eco-friendly refrigrant suitable wall mounting as per site requirement and approval of Engineer-in-Charge without copper pipe and all fitting including ODU stand complete in all respects. For 1.50 Ton
Providing and fixing refrigerant copper pipe of imported make with insulation and vinyl tape of suitable size as per tonnage complete in all respects.
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (50/0.25mm), 3Core
AUTOMATIC VOLTAGE STABLIZER: Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- Automatic Voltage Stablizer 5 KVA
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. Through wall 34.29 cm thick
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition Size 75 mm x 75 mm
Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects.(including existing ACs) uPVC Pipe 6 Kgf/cm2 40mm i/d
Rain Water Harvesting System: Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base.
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 110mm o/d pipe of 4 Kgf. / sqcm
200mm o/d pipe of 4 Kgf. / sqcm
Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level removal of surplus spoils from the site of works upto chain (15 m), complete in all respects. For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky
Construction of Haudi internal size 0.90mtr x 0.90mtr & 0.90mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x600 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge Haudi Inside size 90x 90 cm and90 cm deep
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 90x150 cm and 120 cm deep
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
Fixing of rain water pipe including clamps fitting, jointing cement mortar in 1:4
Providing and fixing M.S. Jali Size 100mm x 100mm
Making connection of drain or rain water pipe with existing pipe line line/man hole complete in all respects.
Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick C.C 1:6:12 in foundation, first class brick work laid in cement sand mortar 1:5, 40mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12.50mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1mm thick left absolutely smooth polished and correct to template including cost of precasted RCC road gully grating and frame including paint with coal tar (as specified in item No. 29.49) complete and to the requirement of the engineer in charge Single Road Gully chamber Size 610mm x 457mm x 800mm
Foot Rest for Manhole.: Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Fixing of rain water pipe including clamps fitting, jointing cement mortar in 1:4
Providing and fixing M.S. Jali Size 100mm x 100mm
Internal E.I. Services RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring TV socket point (one module)
Wiring Networking socket point RJ45 (one module)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (With fan box)
Wiring light point
Wiring call-bell point
Wiring 6Amp. wall socket point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
Wiring light point without control switch.
Wiring light point with double control switches.
SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:- Wiring light point
Wiring 16/20Amp. power plug control point
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1 sq.mm (Un-sheathed)
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Overall size 4sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
Overall size 10sq.mm (Un-sheathed)
Overall size 16sq.mm (Un-sheathed)
Overall size 35sq.mm (Un-sheathed)
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (50/0.25mm), 3Core
Overall size 4.0sq.mm (56/0.3mm), 3Core
Overall size 6.0sq.mm (84/0.3mm), 3Core
XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 10sq.mm (2Core) Un-armoured (Loose)
Overall size 16sq.mm (2Core) Un-armoured (Loose)
Overall size 16sq.mm (4Core) Un-armoured (Loose)
Overall size 50sq.mm (3½ Core) Un-armoured (Loose)
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
Overall size 120sq.mm (3½ Core) Un-armoured (Loose)
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
HEAVY GAUGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- Supply & erection of 20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan.
HEAVY GAUGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- HGW Conduit Pipe 25mm dia. (1.6mm thick) On Surface
HGW Conduit Pipe 32mm dia. (1.6mm thick) On Surface
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
Heavy Gauge PVC Conduit pipe 32mm dia. (Flushed)
Heavy Gauge PVC Conduit pipe 40mm dia. (Flushed)
HDPE Electrical Conduit Pipe 25mm dia. (Flushed)
HDPE Electrical Conduit Pipe 32mm dia. (Flushed)
HDPE Electrical Conduit Pipe 40mm dia. (Flushed)
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- PVC Flexible Pipe 25mm dia.
8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation: Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
COPPER EARTHING (Upto 14 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
Earthing with 25mm x 5mm Copper Tape (upto 14Metre in Length)
COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- Additional Length 20mm x 3mm thick Copper Tape
Additional Length 25mm x 5mm thick Copper Tape
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- Ceiling Rose (Flush Piano type)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 40amp. (10kA, Curve-C)
MCB Triple Pole 40amp. (10kA, Curve-C)
MCB Triple Pole 50, 63amp. (10kA, Curve-C)
MCB Four Pole 40amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
Supply and erection of RCBO (Residual Current Breaker Overload) for Earth leakage, overload and short circuit protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61009 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- RCBO Four Pole 63amp., Sensitivity 30mA
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- SP&N Double Door Distribution Board 4 way each
SP&N Double Door Distribution Board 8 way each
SP&N Double Door Distribution Board 12 way each
TP&N Vertical Double Door Distribution Board 4 way each
TP&N Vertical Double Door Distribution Board 8 way each
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB 160amp.)
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- Cable End Box for SPN 4 Way
Cable End Box for SPN 8 Way
Cable End Box for SPN 12 Way
Cable End Box for TPN 4 Way
Cable End Box for TPN 8 Way
Cable End Box for TPN Vertical 4/8/12Way
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): LT PANELS: Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel.
The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.
Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.
LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm) (Main Panel Incomer:- MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting =1 no. Outgoings:- MCCB 160Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=1 no., MCCB 160Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=1 no., MCCB 100/63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=6 no. )
MCCB's (FOR PANELS & SHEET ENCLOSURE): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- Cable Tray Size 150mm x 50mm x 50mm (2mm thick)
Cable Tray Size 300mm x 50mm x 50mm (2mm thick)
LAYING OF UNDER GROUND CABLES, DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS: Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.)
Double Walled Corrugated HDPE Pipe 63/ 51mm (Outer/ Inner dia.)
Double Walled Corrugated HDPE Pipe 90/ 76mm (Outer/ Inner dia.)
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- Aluminium thimble cable Core size 10 -16sq.mm
Aluminium thimble cable Core size 25 -35sq.mm
Aluminium thimble cable Core size 50sq.mm
Aluminium thimble cable Core size 95sq.mm
Aluminium thimble cable Core size 120sq.mm
SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS): Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:- Bus Bar Chamber 63amp., 415volts Overall Dimensions (350mm x 450mm x 150mm) nominal
Supply and erection of Surface mounted 12watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Surface mounted 18watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Recessed mounted 36watt LED 2x2 panel (including constant LED driver) with CRCA sheet having with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers and hanging GI wire with top roof complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Recessed mounted 18watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of LED batten 20watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary
Supply and Erection of LED Bulk Head 9/10 Watt Surface mounted Pressure Die Cast Aluminium body (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of Mirror LED batten 10watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Heavy duty Exhaust Fans 300mm 900RPM with aluminium louver shutter Canon of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Ceiling Fans 1200 mm Sweep (48") 3-Star fan without fan regulator copper wound including flexible wire & petty material etc.complete in all respects as appd. and desired by the Engineer in-charge at site.
Supply and erection of LED batten 40watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of ventilation fan 200mm 8 Inch including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Wall fan 400mm Swing 16 Inch high speed including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Air Circulator Wall Fan 600MM Metallic Body, 24" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Dry Chemical powder (DCP) type Fire extinguisher 6Kg ISI mark: 15683 complete with squeeze type lever, hose, filled with ISI mark powder IS 4308 Complete in all respect as desired by engineer in charge of the work.
Supply and erection of writing shock chart (Calendar Type) Complete in all respect as desired by engineer in charge of the work.
Supply and erection of providing and fixing of fire bucket with MS hook stand complete in all respect as desired by engineer in charge of the work.
Supply and erection of Non skkid rubber mat ISI 1000mm x 2000mm x 12mm for 11 KVA supply complete in all respect as desired by engineer in charge of the work.
Supply, Installation & Testing of Chemical Earthing (Maintenance Free Earthing) System with UL Approved Copper Bonded Rod and exothermically welded Cu Busbar both tested by CPRI at 50kA Fault Current. A Copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper bonding thickness of minimum 250 microns. Along with Earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A Copper clad steel solid ground wire of 8 mm dia. For interconnecting earth pits including earth pit covers is required.Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber.The grounding minerals should not be pollute the ground water.The grounding minerals shall be tested & certified for the resistivity of less than 0.12ohm mtr complete in all respect as desired by engineer in charge of the work.
Supply, installation, testing & commissioning of Microwave based Occupancy sensor having high performance, non regulating programmable type, suitable for connected load up to 8.5 amp. For mounting height up to 2.5 mtr. and for 8*8 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.complete in all respects as approved and desired by the Engineer-in-charge of the work.
Supply, installation, testing & commissioning of Passice Infrared (PIR) technology based Occupancy sensor having high performance, non regulating , suitable for connected load up to 5.2 amp. For mounting height up to 2.5 mtr 3 X 3 m coverage area complete as required.complete in all respects as approved and desired by the Engineer-in-charge of the work.
Supply, Erection, Testing & commissioning of Inverter sine wave 2300VA with 2 no's 160AH Tubular battery & rack in all respect upto the entire satisfaction of the Engineer-in-charge of work.
Supply, Installation, testing and Commissioning of Outdoor / IN-Ground Speaker complying to following:-Weather-proof 5-position tap switch for 25/70.7/100 Volt, Frequency Response of 62 Hz – 22 kHz, 32 / 16 / 8 Watt, UV-, scratch- and weather-resistant, Suitable for high quality Music, corrosion- and theft-resistant mounting hardware, IP 55 rated, tested in accordance to IEC60268 - Part 5 for high quality intelligibility complete with necessary mounting hardware & accesories, Applicable for Indoor and outdoor usescomplete with necessary mounting hardware & accesories.Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, testing and Commissioning of Compact Indoor/Outdoor Background/Foreground Speaker, 200 W Continuous Program (2 hrs), 100 W (400W peak) Continuous Pink Noise (2 hrs), 75 W (300W peak) Continuous Pink Noise (100 hrs), Transformer Tap at 70V: 30W, 15W, 7.5W, 3.7W Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, testing and Commissioning of All-Weather Compact 2-Way Coaxial Loudspeaker with 8” LF, 200 Watt 70V/100V multi-tap (built-in transformer) or direct 8Ω low-impedance, Highly weather-resistant IP56 rating Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, Testing & Commissioning of 600W Four Channel Class-D Amplifier with following features:- 600W RMS per Channel, Amplifier output 100V/70V/2/4/8/16 Ohm, Supply input AC 110/230V-50Hz. Cooling fans Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing & Commissioning oftackable & fully programmable DSP Audio processor with following features:- IP Port for prgramming, control & monitoring from remote location, flexible I/O configurations with total 16 I/Os, Hardware combination of 8IN/8OUT Excellent sound quality min 96kHz sampling rate, 100MB in-built memory for 36 minutes recordable message player, 16 control inputs & 8 remote TTL outputs for Fire Alarm System integration, scheduler & event management, RS232 port for third party control, RS485 Port for digital microphones remote controllers, DSP based feedback killers, ambient noise sensing, mixers & cross-overs, Graphic user interface for monitoring & control from PC including a PC software for system installation suitable for automatic voice evacuation, zone wise paging & high quality multi-channel background music (Controller). Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, Testing and Commissioning of Soft adressable microphone console with following features:-8 programmable buttons & 1 all call button, CAT 5e connection, RS-485 communication protocol, in-built pre-amplifier, hold & busy LED's, zone LEDs, any button programmable for zones, group zones, music ON/OFF, music volume, expansion port for adding keypads, 128kB audio storage memory, Unidirectional Condenser Microphone with Cardio Polar Reception, integrated monitoring speaker, 1000 metres distance from central PA rack. Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing & Commissioning of 19-inch Equipment Rack with standardized (EIA 310-D, IEC 60297 and DIN 41494 SC48D) frame or enclosure for mounting multiple PA controllers, CD player, FM sources, Amplifiers etc modules, shall have Lockable doors, with proper ventilated and open able doors from all sides, with casters and with cooling fans as above complete with necessary mounting hardware & accesories. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply & Laying of 2 core 1.5sq mm Superior Quality speaker wire Connects audio speakers to A/V receiver or amplifier should be laid in existing PVC/HDPE pipe complete in all respect as desired by the engineer in charge at site.
Supply & Laying of 2 core 2.5sq mm Superior Quality speaker wire Connects audio speakers to A/V receiver or amplifier should be laid in existing PVC/HDPE pipe complete in all respect as desired by the engineer in charge at site.
Supply & Laying of 2 core 4sq mm Superior Quality speaker wire Connects audio speakers to A/V receiver or amplifier should be laid in existing PVC/HDPE pipe complete in all respect as desired by the engineer in charge at site.
Supply, installation, testing & Commissioning of Microphone cable Complete in all respect to the entire satisfaction of the engineer-in-charge .
Cost of LAN Networking System: Supply, Installation, Testing & Commissioning of POE+ 190 Watt Switch with at least 24 Port X 10/100/1000BASE-T Ports and 2 x 1G Base-T / SFP Ports, Switching capacity should be 68 Gbps, Switch should support 128 L3 IP interfaces, ACL, QOS, VRRPv3, Equal-Cost Multi-Path (ECMP) , UDP helper, Policy-based Route (PBR), 802.1x, Embedded 6 kV surge protection on ethernet ports, Switch should have console port, RJ45 Management Port and USB port,. Certification: CE, FCC, BSMI, CB and UL. OEM should available in Gartner Magic Quadrant for Wired and Wireless LAN Access Infrastructure Report from latest last three consecutive year. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, Testing and Commissioning of Dual-Band AP (Access Point) Wireless, Superior throughput with Dual-band transfer speeds packed with all the advances of Wave 2 ac Access Point. Channel Bonding, MU-MIMO,2.4 GHz: IEEE 802.11b/g/n,5 GHz: IEEE 802.11a/n/ac,802.11ac @ 80 MHz: 866, 780, 650, 585, 520, 390, 260, 195, 130, 65 Mbps, 802.11n @ 40 MHz: 300, 270, 240, 180, 120, 90, 60, 30 Mbps, 802.11a/g @ 20 MHz: 54, 48, 36, 24, 18, 12, 9, 6 Mbps, 802.11b @ 20 MHz: 11, 5.5, 2, 1Mbps,2x2:2 MU-MIMO, WPA2-TKIP/AES Personal, WPA-TKIP/AES Personal, WPA2-Enterprise (802.1x/EAP), WPA Enterprise (802.1x/EAP), Open, 4 x Internal Omni-Directional Antennas, 3 x 10/100/1000 Base-T with One PoE In (802.3af/at) port, Three years limited liability manufacturer’s warranty from DATE OF ACTIVATION of the device Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing & Commissioning of SFP Module 1 G compatible with MM Module Complete in all respect to the entire satisfaction of the engineer-in-charge Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, installation, testing and commissioning of 24 port, modular design, loaded Patch Panel 4X6 TYPE, populates up to 24 UTP keystone-type jacks in 1U,Enhanced with cable strain relief with retention tray, combination of high grade plastic and CRS metal,Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, snap-on apertures, RoHS complied, compatiable with Cat 5, Cat 6 and Cat 6A UTP Keystone Jack,Compatible with RJ standard plugs (RJ11, RJ12, RJ45), PCB and with tool Less connection of installation cables AWG 24 – 22 (0.5 mm – 0.65 mm) and flexible cables AWG 26/7 – AWG 22/7.,Termination should feature nil crossover in acc. with EIA/TIA 568-A/B, gold-plated 50micron bronze contacts for >750 mating cycles, >200 insertion cycle,Connector should be 50micron gold-plated and supplied with stain relief cap on back side of Jack,Housing material: Polycarbonate (UL-94-V0) Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, installation, testing & Commissioning of Category 6, 1 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, installation, testing & Commissioning of Category 6, 2 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, installation, testing & Commissioning of Wall Mounted Rack network Rack - 12U 500d, with Heavy Duty Extruded Aluminium Frame for rigidity. Fan 90CFM 230V AC, Cable manager 1U (4no's) MS with Loops Shelf, PDU 6 Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing & Commissioning of Rack Mount LIU 12 Port Fully Loaded/Fiber Termination Box with Adaptor Plates and Splicing Tray, adapter plate SC,LC,FX etc options to suit a broad variety of fibre types and adapter styles,terminate 06 Fiber Core , 1RU, Top cover removable for easy installation,12Core Splice Tray and Cable spool , Cable Ring Loaded, Loaded with Adapter Plate of 06 Duplex MM UPC LC Adapter and 1 Blank Plate,Loaded with 12 LC LSZH OM4 buffered fiber Pigtails of 1 meter, Empley slot should be covered with Blank Plate, Pigtails should support IEC 60793-2-50, ITU-T G.652.D/G.657.A1/G.657.A2, support Fire standard IEC 60332-1, IEC 60754 & IEC 61034 Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing & Commissioning of Optical Fibre OM3 MM, SC, Pigtails 1.5m. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, Testing & Commissioning of Optical Fibre OM3 MM, Duplex SC/LC Patch Cord 3m. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, & laying of Cable & Accessories:Optical Fibre Cable OM3 MM, 6 Core FO Cable, SLT-MM, ECCS Armoured, Outdoor, Unitube Type,MultiMode - OM3 compatible with all fiber passive and active components,Outder Jacket : Black HDPE ,Peripheral Strength Member - 2 FRP Rod, Armouring - ECCS Armouring 0.150mm,Water / Moisture Barrier - Thixotropic Gel with Moisture Blocking Tape, Outer Dia and Weight - Min 8mm , 75 KG, Tensile Strength - 1200N , Crush - 2000N, Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, Testing and commissioning of 1 KVA Online UPS 36VDC with In- Built 3 No. Batteries Pure Sine wave with following features:- OVCD, Wide input range, Programmable output range 208V/220V/230V/240V, 12V x 7Ah x 3 No. SMF batteries in-built, Output Power Factor 0.9, 0ms Transfer time from Inverter Mode to Battery Mode ,Charger Current 1.5 Amp, Cooling Fan, True Online Double Conversion, Inbuilt Over-voltage Cut-off Device, Inbuilt Over Temperature Protection, Surge Protection, Better Overload Protection upto 105% Constant, Higher Efficiency up-to 92% in ECO Mode, 2 year onsite warranty on UPS with 30+ minutes Back up time on switches load complete in all respects as approved and desired by the Engineer-in-charge at site
COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES: Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- CAT 6 LAN cable
Cost of EPABX System Supply, Installation, Testing & Commissioning of POE+ 360 Watt Switch with at least 24 Port X 10/100/1000BASE-T Ports and 2 x 1G Base-T / SFP Ports, Switching capacity should be 68 Gbps, Switch should support 128 L3 IP interfaces, ACL, QOS, VRRPv3, Equal-Cost Multi-Path (ECMP) , UDP helper, Policy-based Route (PBR), 802.1x, Embedded 6 kV surge protection on ethernet ports, Switch should have console port, RJ45 Management Port and USB port,. Certification: CE, FCC, BSMI, CB and UL. OEM should available in Gartner Magic Quadrant for Wired and Wireless LAN Access Infrastructure Report from latest last three consecutive year. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, installation, testing and commissioning of 24 port, modular design, loaded Patch Panel 4X6 TYPE, populates up to 24 UTP keystone-type jacks in 1U,Enhanced with cable strain relief with retention tray, combination of high grade plastic and CRS metal,Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, snap-on apertures, RoHS complied, compatiable with Cat 5, Cat 6 and Cat 6A UTP Keystone Jack,Compatible with RJ standard plugs (RJ11, RJ12, RJ45), PCB and with tool Less connection of installation cables AWG 24 – 22 (0.5 mm – 0.65 mm) and flexible cables AWG 26/7 – AWG 22/7.,Termination should feature nil crossover in acc. with EIA/TIA 568-A/B, gold-plated 50micron bronze contacts for >750 mating cycles, >200 insertion cycle,Connector should be 50micron gold-plated and supplied with stain relief cap on back side of Jack,Housing material: Polycarbonate (UL-94-V0) Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply & erection of IP Telephone, PoE, SIP with Display, Redial, CLIP, 2 Way Speaker, Mute Compatible with EPABX System. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply & erection of Executive IP Telephone, PoE, SIP with Large Backlit with 2 Giga LAN Ports 1000 Mbps Speed, 16 Direct dialling keys Backlit Display, Direct Dialling Keys, HD sound quality, Duplex Speaker Phone, Context sensitive keys POE Support, Adaptor Support, 3.1 inches Screen, VoIP Protocol including all features listed in Product Boucher complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, installation, testing & Commissioning of Category 6, 1 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, installation, testing & Commissioning of Category 6, 2 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charge .
COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES: Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- CAT 6 LAN cable
Cost of CCTV Surveillance System Supply, erection, testing & commissioning of 2MP Motorized Varifocal Bullet PoE Camera 1920×1080@ 60FPS, 1/2.8" Progressive CMOS (Scanning System), Focal Length: Motorized Varifocal 2.8-12mm, Color 0.002lux @ F1.6(AGC ON); B/W 0 lux @ IR ON, IR Distance: 50m, BLC, 3D DNR, WDR: 120dB, AGC, White Balance, Electronic Shutter: 1/5 ~ 1/20000sec, Built-in microphone, Video Compression: H.264 & H.265, Unicast/Multicast Streaming, Video Streams: Triple-Stream, Primary Stream: 1080P @60fps(1920x1080), 960P(1280x960), 720P(1280x720), Secondary Stream: 720P@30fps (1280x720), VGA(640x480), QVGA(320x240), Tertiary Stream: VGA@30fps (640x480), QVGA (320x240), Bitrate: 256Kbps ~ 8Mbps, ONVIF( Profile S/G/T), AI Support: Face Recognition, Human & Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Cross Counting, Stationary Object Detection, Heat Map, Crowd Density Detection, Queue Length Detection, license Plate Detection, Rare Sound Detection, Bitrate: 256Kbps ~ 8Mbps, ONVIF( Profile S/G/T), Inbuild Micro SD slot: up to 256GB SD Card, IP67 & Metal Body Including: Alarm: 1 input, 1 output, Audio: 1 input (RCA), 1 output (RCA). The camera apecification should be complied with STQC & STQC Certificates or applied certificate should be submitted in the time of delivery of material. Certification : CE, FCC & BIS. complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, erection, testing & commissioning of NVR shall have 64-channel video input. NVR shall be Embedded Linux. NVR shall support following bandwidth - 1280Mbps, Incoming 640Mbps & Outgoing 640Mbps. NVR shall support Video Output: 3 (1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080, 1600*1200, 1920*1200, 3840*2160/7680*4320) HDMI; 1 (1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080). Async out. NVR shall offer the following recording resolution streams Video Resolution: 12MP, 8MP, 5MP, 3MP, 2MP (1080P), 1.3MP (960P), 1.0MP (720P). NVR shall support Preview Capability: multiple matrix mode, Supported frame rate: 4K:240fps, 4MP:480fps, 2MP:960fps. NVR shall support schedule base snapshot, manual snapshot, event-based snapshot. NVR shall support Motion Detection. NVR shall support 4 zones Privacy Mask. NVR shall offer intelligent analysis functions powered including Human & Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Stationary Object Detection, Crossing Counting, Heat Map, Crowd Density Detection, Rare Sound detection (gunshot/baby crying/dog barking), Face Detection. AUDIO. NVR shall support G.711A/G.711U Audio compression. NVR shall integrate Audio input 1 CH RCA port. NVR shall integrate Audio output 1 CH RCA port, HDMI audio. Video Recording and Playback. NVR shall support 1-30fps Video Frame Rate. NVR shall have Record Mode: schedule, event based- motion, I/O, PIR. NVR shall offer 16 CH max sync playback. NVR shall be able to playback according to different types, including Playback Mode Instant playback, Local video, local image. NVR shall support Record Search Time, calendar, channel search, and event search, (ANR, regular video, motion detection video, alarm video, intelligent detection video). NVR shall support following Video Playback: Start, stop, normal play, back play, frame by frame forward, full screen, Fast forward/backward (2x, 4x, 8x, 16x), Slow forward (1/2x, 1/4x, 1/8x, 1/16x), Add custom/ Default Tag, digital zoom, video clip, sub-stream/main-stream, playback video bar, scale of 30 mins to 24 hrs. NVR shall support 8 SATA, 1 x eSATA, HDD Capacity Single max. 18TB (enterprise class) & up to 12TB Surveillance HDD. NVR shall support RAID0, RAID1, RAID5, RAID6, RAID10. NVR Should have S.M.A.R.T info feature to check health of HDD, temperature and status. NVR shall offer Local, Network HDD NFS, SMB/CIFS. NVR shall offer USB mobile hard disk, U disk, network backup Method. NVR Should support FTP for uploading alarm video. NVR shall ANR Support Smart IPC (with SD card) ANR. Function. NVR shall support the following protocol: IPv4, IPv6, TCP/IP, HTTP, HTTPS, DDNS, RTMP, SMTP(SSL), SNMP, DHCP, PPPoE, UPnP, NTP, P2P, FTP, IP filter. NVR shall support ONVIF Profile S Support. NVR shall support
ONVIF/RTSP/HTTP/HTTPS/RTMP port customized. NVR shall support Mobile Surveillance Support Apple, Android & Internet Explorer Support IE, Chrome, Firefox, Safari. NVR shall Digital Zoom support. NVR shall have IPC timing Manual/auto/timing/reconnect timing. NVR shall support the following Event Actions: pre and post recording, Send email, show message, send email, FTP upload video or screenshot, Cloud upload video or screenshot, full screen, voice prompts, Alarm output trigger, PTZ linkage. NVR Should support combination of different events for effective alarm trigger and response. NVR Shall have exception alarms on event type of no space on disk, disk error, video loss. NVR Shall be able to configure covert on camera by which recording is happening, but live view is restricted. Network Detection monitoring, Utilization of total and used bandwidth, IP filter with blacklist and whitelist. NVR Shall support video cover privacy mask both on live and recording up to 4 areas. NVR shall have User Management User add, delete, modify, permission management, support. NVR Shall be able to trigger PTZ presets on any camera AI event. NVR shall support Security Mode Authorized username and password, HTTPS with password, RTSP Validation. NVR should Manage IPC Support IPC centralized management, including IPC parameter configuration, information export and import, real-time information acquisition and upgrade. NVR shall have Statistics of events for face recognition, vehicle & human, cross count and heat map. Network Interface. NVR shall integrate 2 X RJ45 10M/100M/1000M adaptive Ethernet port. Alarm Input 16 CH alarm input & Alarm Output 4 CH alarm output. NVR shall integrate 1* RS485 , 1* RS232 & USB2.0*1(front), USB3.0*2(rear). General. The power consumption shall be AC 100-240 V, 250W & Power Consumption ≤8W (Without HDD). Operation Temp./ Humidity -10°C ~ 55°C/10%-90% complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, Installation, Testing & Commissioning of POE+ 190 Watt Switch with at least 24 Port X 10/100/1000BASE-T Ports and 2 x 1G Base-T / SFP Ports, Switching capacity should be 68 Gbps, Switch should support 128 L3 IP interfaces, ACL, QOS, VRRPv3, Equal-Cost Multi-Path (ECMP) , UDP helper, Policy-based Route (PBR), 802.1x, Embedded 6 kV surge protection on ethernet ports, Switch should have console port, RJ45 Management Port and USB port,. Certification: CE, FCC, BSMI, CB and UL. OEM should available in Gartner Magic Quadrant for Wired and Wireless LAN Access Infrastructure Report from latest last three consecutive year. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, erection, testing & commissioning of HDD Formatted capacity 6 TB, Data transfer rate (max) Buffer to host Host to/from drive (sustained) 6 Gb/s 171 MB/s, Cache (MB) 64, Rotational speed (RPM) IntelliPower, Load/unload cycles4 300,000, Non-recoverable read errors per bits read <1 in 1014,Operating (2 ms, read/write) 30,Operating (2 ms, read) 65, Non-operating (2 ms) 250,Average power requirements (W) Read/Write 5.90, Idle 4.90, Standby and Sleep 0.40 complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, erection, testing & commissioning of Display : 55 inch, 4K (3,840 x 2,160), Direct LED, Professional Display with 4K Processor, Native Contrast ratio 5,000:1 or higher, Response time 12 ms or lower, Brightness 400 cd/m² or higher, 24/7, Portrait/Tilt functionality, HDMI Auto wake up, HTML5 platform, 16GB On Board Storage, HDMI*4 with HDCP 2.3 / RS232 / USB / RJ45 / Wi-Fi Direct / 20W Speakers / Android OS or similar, Viewing angle 178 degree, Apple AirPlay & Chromecast. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, Installation, Testing & Commissioning of 6 Mtr HDMI Cable for NVR, UL Listed complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing and commissioning of 1 KVA Online UPS 36VDC with In- Built 3 No. Batteries Pure Sine wave with following features:- OVCD, Wide input range, Programmable output range 208V/220V/230V/240V, 12V x 7Ah x 3 No. SMF batteries in-built, Output Power Factor 0.9, 0ms Transfer time from Inverter Mode to Battery Mode ,Charger Current 1.5 Amp, Cooling Fan, True Online Double Conversion, Inbuilt Over-voltage Cut-off Device, Inbuilt Over Temperature Protection, Surge Protection, Better Overload Protection upto 105% Constant, Higher Efficiency up-to 92% in ECO Mode, 2 year onsite warranty on UPS with 30+ minutes Back up time on switches load complete in all respects as approved and desired by the Engineer-in-charge at site
Supply, installation, testing and commissioning of 24 port, modular design, loaded Patch Panel 4X6 TYPE, populates up to 24 UTP keystone-type jacks in 1U,Enhanced with cable strain relief with retention tray, combination of high grade plastic and CRS metal,Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, snap-on apertures, RoHS complied, compatiable with Cat 5, Cat 6 and Cat 6A UTP Keystone Jack,Compatible with RJ standard plugs (RJ11, RJ12, RJ45), PCB and with tool Less connection of installation cables AWG 24 – 22 (0.5 mm – 0.65 mm) and flexible cables AWG 26/7 – AWG 22/7.,Termination should feature nil crossover in acc. with EIA/TIA 568-A/B, gold-plated 50micron bronze contacts for >750 mating cycles, >200 insertion cycle,Connector should be 50micron gold-plated and supplied with stain relief cap on back side of Jack,Housing material: Polycarbonate (UL-94-V0) Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, installation, testing & Commissioning of Category 6, 1 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing & Commissioning of SFP Module 1 G compatible with MM Module Complete in all respect to the entire satisfaction of the engineer-in-charge Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing & Commissioning of Outdoor type Wall Mount Rack 6U/500 Rack/WMOD/Metal Door/ OutDoor/IP56/Off White with Pole Mounting Bracket. 1 No. Server Rack Air Circulation module/90CFM with 2 Nos. Filter Unit/Double louvered Module/IP56, ISO Standards, Standard Accessories Available Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, Testing & Commissioning of Rack Mount LIU 12 Port Fully Loaded/Fiber Termination Box with Adaptor Plates and Splicing Tray, adapter plate SC,LC,FX etc options to suit a broad variety of fibre types and adapter styles,terminate 06 Fiber Core , 1RU, Top cover removable for easy installation,12Core Splice Tray and Cable spool , Cable Ring Loaded, Loaded with Adapter Plate of 06 Duplex MM UPC LC Adapter and 1 Blank Plate,Loaded with 12 LC LSZH OM4 buffered fiber Pigtails of 1 meter, Empley slot should be covered with Blank Plate, Pigtails should support IEC 60793-2-50, ITU-T G.652.D/G.657.A1/G.657.A2, support Fire standard IEC 60332-1, IEC 60754 & IEC 61034 Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing & Commissioning of Optical Fibre OM3 MM, SC, Pigtails 1.5m. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, Testing & Commissioning of Optical Fibre OM3 MM, Duplex SC/LC Patch Cord 3m. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, & laying of Cable & Accessories:Optical Fibre Cable OM3 MM, 6 Core FO Cable, SLT-MM, ECCS Armoured, Outdoor, Unitube Type,MultiMode - OM3 compatible with all fiber passive and active components,Outder Jacket : Black HDPE ,Peripheral Strength Member - 2 FRP Rod, Armouring - ECCS Armouring 0.150mm,Water / Moisture Barrier - Thixotropic Gel with Moisture Blocking Tape, Outer Dia and Weight - Min 8mm , 75 KG, Tensile Strength - 1200N , Crush - 2000N, Complete in all respect to the entire satisfaction of the engineer-in-charge
COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES: Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- CAT 6 LAN cable
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Cost of Fire Alarm Addressable Detection System Supply and erection of Conventional Fire Alarm 8 Zone include with 30 Watt Amplifier complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of Manual Call Point complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of High Intensity Hooter complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of Smoke Detector with base complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of Heat Detector with base complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of Multi Criteria Detector with base complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of Reponse Indicator complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of 2 Nos. 12 Volt 7 Ah Battery complete in all respects as approved and desired by the Engineer in-charge at site.
PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (48/0.20mm), 2Core
Supply and erection of fire survival cable for fire alarm & PA system with annealed stranded copper conductor, fire resistant mica tape wrapped (at 950°C for 180 minutes), XLPE insulated, LSHZ (low smoke & zero halogen) bedding, LSZH (low smoke & zero halogen) red outer sheath, galvanized steel wire armour, 600/1000 volts grade, Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ, Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3) left bare in pipe or casing or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Fire Survival cable 2Coe x 1.5 sq.mm
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- Heavy gauge welded conduit pipe 25mm dia. (ISI marked 1.60mm thick) Flushed
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Cost of Security/ Campus Lighting and Fascade/ Decorative Lighting PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (48/0.20mm), 3Core
Overall size 4.0sq.mm (56/0.3mm), 3Core
Overall size 6.0sq.mm (84/0.3mm), 3Core
Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (48/0.20mm), 2Core
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- Overall size 10sq.mm (3Core) Un-armoured (On-Surface)
XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 16sq.mm (4Core) Un-armoured (Loose)
Overall size 16sq.mm (2Core) Un-armoured (Loose)
Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
Heavy Gauge PVC Conduit pipe 40mm dia. (Flushed)
HDPE Electrical Conduit Pipe 25mm dia. (On Surface)
HDPE Electrical Conduit Pipe 25mm dia. (Flushed)
HDPE Electrical Conduit Pipe 40mm dia. (Flushed)
GALVANIZED IRON PIPES AND G.I. EARTHING Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- GI Earth rod 20 mm dia., 3 mtr. Long
PVC CHANNEL (uPVC TRUNKING): Supply and erection of PVC Channel (uPVC Trunking) with cover of various sizes (On Surface) on wall, Flat angle, internal & external angle, Flat Tee, End cap and mounting boxes including the cost of joint cover, fixing and other petty material etc.:- PVC Channel (uPVC Trunking) 50mm x 50mm
PVC Channel (uPVC Trunking) 100mm x 50mm
Flat Angle 50mm x 50mm
Flat Angle 100mm x 50mm
Flat Tee 50mm x 50mm
Flat Tee 100mm x 50mm
Mounting Box 1-3 Module
Mounting Box 4-5 Module
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 40amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- SP&N Double Door Distribution Board 8 way each
SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS): Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site: Bus Bar Chamber 63amp., 415volts Overall Dimensions (350mm x 450mm x 150mm) nominal
MCCB's (FOR PANELS & SHEET ENCLOSURE): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
GALVANIZED STEEL OCTAGONAL POLES FOR WIND VELOCITY OF 169 Km/ HOUR: Supply and Erection of Galvanized Steel Octagonal Pole (Sheet Thickness 3mm) with base plate designed to withstand wind speed 169 km/hour of suitable length Sheet Steel Confirming to IS 2062 : 2011 E350B0 (Yield Stress must be min 355Mpa and Tensile Strength min 470Mpa which is equivalent to BS-EN10025S355J or ASTM-572A GR-50) and thickness of Hot dip galvanization coating (70microns) conforming to IS:2629/ IS:2633/ IS:4759: BSEN-ISO-1461-1991 OR ASTM A 123/A123M-02. The pole shall be in single piece hot dip galvanized and shall be tapered towards the top. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase four wire cable connection, Bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The Octagonal Pole shall be bolted on pre- cast foundation with a set of four foundation bolts of EN-8 Grade with thread portion hot dip galvanized for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level as required. Galvanized Octagonal Pole Overall Length 7 metre (Sheet thickness 3mm), Top dia.(A/F) 70mm and bottom dia. (A/F) 130mm, Foundation size below G/L 550mm x 550mm x 1400mm, 4Nos. Foundation Bolts size 20mm dia., Length≥700mm with Base Plate Dimensions 220mm x 220mm x 14mm Thick
GALVANIZED OCTAGONAL POLE BRACKETS: SINGLE/ DOUBLE ARM BRACKETS: Supply and erection of bracket for galvanized octagonal pole, the bracket should be fixed on the top of the pole having top outer dia. 70mm to 90mm (A/F) complete in all respect as approved by the Engineer-in-charge at site:- Single arm bracket 1 metre long for galvanized octagonal pole
Double arm bracket 1 metre long for galvanized octagonal pole
LAYING OF UNDER GROUND CABLES, DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS: Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement
SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 250mm x 200mm x 100mm with hinged water tight cover with locking arrangement
SMC GLASS FIBRE INSPECTION BOXES: Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirming to IS:14772, (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement complete in all respect as approved and desired by the Engineer In-Charge at site:- SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 300mm x 200mm x 105mm with hinged water tight cover with locking arrangement
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double walled corrugated (DWC) HDPE pipe 50 / 38mm (outer/inner dia.)
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- Aluminium thimble cable Core size 10 - 16sq.mm
Aluminium thimble cable Core size 25 -35sq.mm
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: CUBICAL PEDESTAL: Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- Cubical Size 1400mm high, 1200mm wide and 500mm deep with platform dimensions 1300mm x 600mm x 450mm
Supply, Installation & Testing of Chemical Earthing (Maintenance Free Earthing) System with UL Approved Copper Bonded Rod and exothermically welded Cu Busbar both tested by CPRI at 50kA Fault Current. A Copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper bonding thickness of minimum 250 microns. Along with Earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A Copper clad steel solid ground wire of 8 mm dia. For interconnecting earth pits including earth pit covers is required.Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber.The grounding minerals should not be pollute the ground water.The grounding minerals shall be tested & certified for the resistivity of less than 0.12ohm mtr complete in all respect as desired by engineer in charge of the work.
Supply and Erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Making of Cement Concrete plinth 600mm x 600mm x 1800mm deep for fixing of tubular poles, Earth Work in excavation in foundations including dressing of bottom and sides of trenches, shuttering for faces of concrete foundations, cage of cold twisted deformed steel Bar Fe 500 grade as per IS 1786-2008 & filling with reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator complete including fixing the 4 nos foundation bolts in cement concrete plith in all respects as approved and desired by the Engineer-in-charge at site.
Supply and erection of LED Street Light 70/72 watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply ,erection, testing and Commissioning of wall washer exterior BIS registered 3000K LED luminaire for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass, of Total System wattage not exceeding 12W with all LEDs on, minimum system lumen efficacy >80lm/w. Luminaire should be complete with dedicated Lens for each LED offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaire shall be IP66 and IK08 rated. LED Life time shall be at least L70B50 @50000 burning hours at 35°C. Fixture should be >80 CRI and SDCM <5. LED chip source should be of make Nichea, Osram, Cree, Lumiled, Philips, Seoul only. Luminaire shall used with remote driver BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor > 0.9. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.complete in all respects as approved and desired by the Engineer in-charge at site.
Supply ,erection, testing and Commissioning of exterior BIS registered 3000K CCT LED Spot lighting luminaire for Architectural Designer lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass, of Total System wattage not exceeding 15W with Min system lumen output >=1150 lm with all LEDs on ,the system system lumen efficacy >80lm/w. Luminaire should be complete with dedicated Lens for each LED offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. teh product should have fins in concentric rings only. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaire shall be IP66 and IK06 rated. LED Life time shall be at least L70B50 @50000 burning hours at 35°C. The product should be proper with IP 67 rated fused connector. The product should be Designer and should have a glare shield inbuilt in the casting of the product . Fixture should be >80 CRI and SDCM < 5. LED chip source should be of make Nichea, Osram, Cree, Lumiled, Philips, Seoul only. Luminaire shall be used with a remote BIS IP 66/67 potted driver and capable of operating at line voltage from 100-300 Vac, 50Hz with power factor > 0.9. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. complete in all respects as approved and desired by the Engineer in-charge at site.
Supply ,erection, testing and Commissioning of exterior BIS registered 3000K CCT LED flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass, of Total System wattage not exceeding 36W with system lumen output >=3000lm with all LEDs on , with system lumen efficacy >85lm/w. Luminaire should be complete with dedicated Lens for each LED offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaire shall be IP66 and IK08 rated. LED Life time shall be at least L70B50 @50000 burning hours at 35°C. The product should be proper with IP 67 rated fused connector. The product should be square and dai casting of the product. Fixture should be >80 CRI and SDCM ≤ 5. LED chip source should be of make Nichea, Osram, Cree, Lumiled, Philips, Seoul only. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 100-300 Vac, 50Hz with power factor > 0.9. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Decorative Lighting Pole 4150mm Long , having Pole specifications are as follows: (i) Base Plate 350x350x12mm thick ( HDG) and with Foundation Bolt M16x 450mm conforming to IS: 2062 (ii) Emblem Size:- Casted Having length 750mm (iii) Galanized Iron Pipe pole having length 3400mm with 76.1mm diameter and 2.9 mm thick Conforming to IS:1239 (iv) 2 NOs. Galvanized Pipe Banner Arm having length 1500mm with 42.4mm Diameter and 2.6mm Thick The Pole is duly pre-treated with shot blasting process & painted in two coats of Epoxy primer and Top coat of exterior grade of paint . Coating on pole should have minimum DFT of 90 microns. Complete in all respect to the satisfaction of the engineer-in-charge & Design as per approved by Advisory Commitee of Shri Kali Devi Temple .
Supply, installation, testing & Commissioning of Decorative Single Arm Bracket with Trident specifications are as follows: (i) Galvanized Ms Sheet Trident with approx size 407mm x 500mm x 3mm thick (ii) Single Arm Decorative Bracket made out from galvanized iron pipe 42.4 mm diameter having 2.6 mm thickness Conforming to IS:1239 as per design attached. The Single arm bracket is duly pre-treated with shot blasting process & painted in two coats of Epoxy primer and Top coat of exterior grade of paint. Coating on bracket should have minimum DFT of 90 microns. Complete in all respect to the satisfaction of the engineer-in-charge & Design as per approved by Advisory Commitee of Shri Kali Devi Temple .
Supply, installation, testing & Commissioning of Decorative Double Arm Bracket with Trident specifications are as follows: (i) Galvanized Ms Sheet Trident with approx size 407mm x 500mm x 3mm thick (ii) Double Arm Decorative Bracket made out from galvanized iron pipe 42.4 mm diameter having 2.6 mm thickness Conforming to IS:1239 as per design attached. The double arm bracket is duly pre-treated with shot blasting process & painted in two coats of Epoxy primer and Top coat of exterior grade of paint . Coating on bracket should have minimum DFT of 90 microns. Complete in all respect to the satisfaction of the engineer-in-charge & Design as per approved by Advisory Commitee of Shri Kali Devi Temple .
Supply, installation, testing & Commissioning of Post top Led light fixture 45 watt, warm white ( 3000K ) having proper die casted heat sink shall be fitted in the top fixture cap , The Led module shall be of minimum efficacy 90 lm/ watt. The module compartment of the lighting fixture shall be of IP-66 /65 Protection complete in all respect to the satisfaction of the engineer-in-charge & Design as per approved by Advisory Commitee of Shri Kali Devi Temple .
Supply ,erection, testing and Commissioning of LED Foot/Wall Light Wattage : 3W,Operating Voltage : AC230V,Colour: 3000K ,Beam Angle : Asymmetric,IP Rating : IP54,IK Rating: IK02 with flushed box in wall complete in all respects as approved and desired by the Engineer in-charge at site.
Supply ,erection, testing and Commissioning of Power Supply Dali - AC100~200V input, DC24V output, 200W, constant voltage power supply IP Rating : IP67 complete in all respects as approved and desired by the Engineer in-charge at site.
Supply ,erection, testing and Commissioning of Ground Burial Light Wattage: 12W, Operating Voltage : DC24V, CCT: 3000K, Beam Angle : 15°, IP Rating : IP67, IK Rating : IK08 complete in all respects as approved and desired by the Engineer in-charge at site.
Supply ,erection, testing and Commissioning of Flood Light Wattage : 24W, Operating Voltage : AC220V, CCT: 3000K, Beam Angle : 45°, IP Rating : IP67, IK Rating : IK08 complete in all respects as approved and desired by the Engineer in-charge at site.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_327627.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.15 MB
BOQ_327627.xls
BOQ • 1.51 MB
dnit.pdf
Tender Documents • 17.86 MB
Download all tender documents and submit your bid