GE KHUMBATHANG
GE KHUMBATHANG
REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION AND OTHER ALLIED WKS AT HANUTHANG, ACHINATHANG, BATALIK AND BIAMAH IN THE AOR OF AGE B R II KHALTSI UNDER GE KHUMBATHANG
2023_MES_605669_1
GE/KHU-33/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE KHUMBATHANG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE KHUMBATHANG
₹40,000
4 Sept 2023
26 Jun 2023
24 Jul 2023
26 Jun 2023
23 Jul 2023
10 Jul 2023
Amount
Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
Taking down un-serviceable sub main wiring of any type and any size from wall, ceiling etc. complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm PVC (FRLS-H) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLSH) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl all fittings such as Tee, connector pieces, L-junction etc on joints including CI/MS/PVC sunk boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light/fan/bell point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed.. Notes : (a) Wiring shall be done by using proper colour coding.(b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC casing 'N' cappingshall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
Description all as per serial item No 04 here-in-before but one 5 pin socket outlet, 5 amps on the same board complete all as specified and directed.
Description all as per serial item No 04 here-in-before but one 5 pin socket outlet, 5 amps, independent complete all as specified and directed.
Description all as per serial item No 04 here-in-before but for one 5 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl all fittings such as Tee, connector pieces, L-junction etc on joints ISI marked including pressed steel with existing colour terminated boxes of Modular Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following:- (a) Wiring shall be done by using proper colour coding(b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge. Note :-Modular white cover plate with frame shall be inclusive in quoted rate .
Description all as per serial item No 8 here-in-before but 6 Amp socket outlet on same board complete all as specified and directed.
Description all as per serial item No 8 here-in-before but socket outlet 6 Amps independent board complete all as specified and directed.
Description all as per serial item No 8 here-in-before but for one 6 pin socket outlet 16 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed.
S&F switch piano, flush type single pole one way 6 Amp, 240 volts ISI marked complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin, 6 A ISI marked complete all as specified and directed.
S&F socket outlet 3 pin, 6/16 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed.
S&F switch piano, flush type single pole, one way 16 Amps, 240 volts ISI marked complete all as specified and directed.
S&F Ding Dong Bell musical type AC 230 volt single pole complete all as specified and directed by engineer in charge.
S&F Bell Push flush type 5A switch, complete all as specified and directed.
S&F ceiling rose, 3 terminal surface type complete all as specified and directed.
S&F angle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F Modular switch 1 way 6 A,1 module, 240 volts ISI marked complete all as specified and directed.
S&F Modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed.
S&F Modular Socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F Socket Modular 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply & fixing surface /wall mounted light fitting pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make-Crompton Greaves /Philips/Bajaj
Supply & fixing energy efficient LED light of 10/12 Watt of length - 02 Feet long having minimum 1100-1300 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make-Crompton Greaves /Philips/Bajaj
Taking down old burnt out bulk head fitting any type and Supply and Fix LED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP66 complete all as specified and directed.Make-Crompton Greaves /Philips/Bajaj
S&F in replacement of existing worn out ceiling light with enviromental friendly, new generation, aesthetically designed, ultra modern recessed mounted LED light luminaries of size 595 mm x 595 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 36/40/42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection suitable for Armstrong/ Grid ceiling with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make-Crompton Greaves /Philips/Bajaj
S & F Sheet metal enclousers, TPN Distribution board 4 way, double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and directed.Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed.Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed.Note:- Distribution board and MCB's should be same make.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S &F of SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S & F of 415V 10KA 'B' curve TPN 63 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sq mm for phase and neutral and one run of 6.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the medium grade ISI mark PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding.
Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm thick buried directly under ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level ,connected to galvanised earth lead wire 4.0mm by means of bolts, nuts, check nuts, washer including test point by means of bolts, nuts, check nuts, and washers of galvanized iron and connected to main switch / control board up to 7.5 metre away from earth electrode and including GI pipe light grade 40mm bore protection pipe & necessary excavation and earth work in any strata, PCC chambers in PCC 1:3:6 type B1, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm dia TMT bars at 140mm C/C both ways, with lifting handle, watering pipe of GI medium grade 40mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per plate No 3 of SSR Part-I and all as specified.
S&F in repair switch piano flush button type 6 amps single pole one way. complete all as specified and directed.
S&F in repair socket outlet multipurpose 2/3 pin 6 amps flush button. complete all as specified and directed.
S& F in repair switch piano flush button type 16 amps single pole one way. complete all as specified and directed.
S & F in repairs socket outlet multipurpose 2 in 1, 6/16 Amps complete all as specified and directed.
S & F in repairs single core flexiable PVC cable 1.5 sqmm of standrad copper conductor pvc insulated unsheathed cables of 1100 volts complete all as specified and directed.
S & F in repairs PVC insulated & unsheathed FRLS-H multistrand copper conductor wire 1100 volt grade of size 2.5 sqmm complete all as specified.
S & F in repairs angle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings. complete all as specified and directed.
S & F in repairs MCB TPN 63 amp, 415 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity. Make -indo asian
S&F in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S &F in repair of SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S & F in repair of 415V 10KA 'B' curve TPN 63 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
S & F in repairs Sheet metal enclousers, TPN Distribution board 4 way, double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Make-Indo asian/Legrand/Havells
S & F in repairs distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and directed.Make-Indo asian/Legrand/Havells
S & F in repairs distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed.Make-Indo asian/Legrand/Havells
S & F in repairs distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed.Make-Indo asian/Legrand/Havells
S & F in repairs surface mounting 9 /12 watt LED mirror light fitting of 2 ft length complete all as specified and directed.
S & F in repairs PVC surface box 3 module with 5 amp switch and socket complete all as specified.
S & F in repairs surface box 3 module with 15 amp switch and socket complete all as specified.
S & F in repairs PVC LT insulation tape roll of size 25 mtr complete all as specified.
S & F in repairs PVC casing caping of size 20mm ,ISI mark complete all as specified.
S & F in repairs rigid non-metallic PVC conduit of size 20mm ,ISI mark complete all as specified.
Deduct Credit for Demolished/Dismantled material Rs (-) 24,111 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
Ms Salaria Builders
M/s Raj Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .