Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
7 Dec 2026, 9:00 am
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
SHRI CHANDRA KUMAR VIDYARTHI
GARRISON ENGINEER (CENTRAL) KOLKATA NAPIER ROAD HASTINGS 700022
REPAIR / REPLACEMENT OF SUBMAIN WIRING, DBs, MCBs AND SERVICE CABLE OF HASTING, OD AND SAHAPORE AREA UNDER GE (C) KOLKATA
2026_MES_798700_1
8995/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kolkata
8 documents required · 8 mandatory
₹500
GE(CENTRAL) KOLKATA
₹50,000
Yes
14 Nov 2026
14 Nov 2026
8 Dec 2026
14 Nov 2026
7 Dec 2026
30 Nov 2026
14 Nov 2026 - 28 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down sub main wiring alongwith damaged casing capping /PVC conduit pipe from the wall roof or in floor and making good disturbuted surfaces complete all as directed | 1,610 | RM | - | - |
| 2 | S&F Sub main wiring with two single core cable PVC insulated unsheathed copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including PVC casing caping with all accessories like tee, bend,elbow of high quality material of size not less than 20mm ISI marked with and including one single core cable PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed
Note:- (i)Three run of 6 Sqmm cable and one run of PVC casing & caping will be measured as one length. | 320 | RM | - | - |
| 3 | -do- all as per item No- 02 here in before but for cable of size 4 Sqmm complete all as specified and directed. | 160 | RM | - | - |
| 4 | S&F Sub main wiring with two single core cable PVC insulated unsheathed copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through existing conduit/casing with and including one single core cable PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed
Note:- (i) Three run of 6 Sqmm cable will be measured as one length. | 450 | RM | - | - |
| 5 | -do- all as per item No- 05 above but for cable of size 4 Sqmm complete all as specified and directed. | 660 | RM | - | - |
| 6 | S&F in repair Sub main wiring with three single core cable PVC insulated unsheathed copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through existing conduit/casing with and including Two single core cable PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for Neutral and earth continuity and connected to common earth dolly and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed
Note:- (i) five lengths of 6 Sqmm cable will be measured as one length. | 20 | RM | - | - |
| 7 | S&F in replacement factory made powder coated distribution board TPN, 8 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 200 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed.
Note :- (i) MCBs shall be measured and paid seperately.
(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. | 2 | Each | - | - |
| 8 | S&F in replacement factory made powder coated distribution board TPN, 4 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 200 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed.
Note :- (i) MCBs shall be measured and paid seperately.
(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. | 6 | Each | - | - |
| 9 | S&F in replacement factory made powder coated distribution board SPN, 4 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 200 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed.
Note :- (i) MCBs shall be measured and paid seperately.
(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. | 10 | Each | - | - |
| 10 | S&F in replacement factory made powder coated distribution board SPN, 8 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 200 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed.
Note :- (i) MCBs shall be measured and paid seperately.
(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. | 46 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
8995TenderDocus.pdf
Tender Documents • 1.28 MB
BOQ_896008.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .