Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 626 6TH FLOOR DLF TOWER A DLF TOWER 626 6TH FLOOR DLF TOWER A JASOLA JASOLA SOUTH DELHI DELHI 110076 | SOUTH DELHI | DELHI | 110076 | Admitted-Finance |
| 2 | Admitted-Finance 1ST FLOOR H NO 29 A SESHAADHRI NILAY NEOG PATH ANANDA NAGAR BEHIND DONA PLANET GS ROAD GUWAHATI 05 ASSAM | Admitted-Finance |
| 3 | Admitted-Finance F 2 B WING FIRST FLOOR SHAPATH HEXA OPP GUJARAT HIGH COURT S G ROAD AHMEDABAD GUJARAT 380054 GJ14B0001796 24AACCS6758G1Z7 R M MII STATUS AS NOT VERIFIED | AHMADABAD | GUJARAT | 380054 | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Techno-commercially not Acceptable |
Tender Value
Refer Docs
EMD Value
₹17.5 L
Closing Date
9 Jun 2023, 3:00 pmClosed
Sekar Hirudhayam
TECHNIP ENERGIES INDIA LTD, CHENNAI
SUPPLY OF EMERGENCY DIESEL GENERATORS FOR NUMALIGARH REFINERY EXPANSION PROJECT
2023_NRL_744316_1
TP/082176C/NRL/PQ/102
Open Tender
Electrical Goods/Equipment
300 days
NUMALIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹17.5 L
Yes
11 Oct 2023
8 Mar 2023
10 Jun 2023
8 Mar 2023
9 Jun 2023
3 Apr 2023
Emergency Diesel Generators (EDG) comprising of Diesel Engine (for each DG set) with air-intake system, lubrication system, governing system, fuel oil system (including 990L day tank for each DG set), cooling system, electrical starting system with battery, battery charger and DC panel, exhaust system (incl. Exhaust system piping, stack along with supporting structure, Expansion bellows and Silencers complying to CPCB norms) and control panel / controller complying the following Type - Prime Rated Voltage rating - 6.6kV Power rating - 2250 kVA output at Site conditions Rated power factor - 0.8 Engine Type - Radiator shall be Engine Mounted Installation - Outdoor EDG shall be supplied with required accessories like Battery charger, Batteries, Control / AMF panel, Synchronization panel for Load control and Synchronization, NIS panel (Neutral isolating switch panel), local isolator, Fuel tank (Day tank), stack along with supporting structure and other accessories as required. Note 1:The UNIT RATE shall be inclusive of (not limited to) all including Packing and forwarding, Pre-Commissioning / Commissioning / Start-Up spares, Special tools and Tackles, Statutory Approvals Note 2: The Scope of supply shall include all equipment and materials required for the safe and efficient operation of the complete system, but not limited to the items listed in MR ref. TP-1ZZZA-ME-RFQ-3001_D1. Any equipment / material not listed herein but is necessary for smooth, safe & trouble free continuous operation and maintenance of the Emergency Diesel Generator (EDG) and other facilities; those required as part of good engineering practices shall be deemed to be included.
Emergency Diesel Generators (EDG) comprising of Diesel Engine (for each DG set) with air-intake system, lubrication system, governing system, fuel oil system (including 990L day tank for each DG set), cooling system, electrical starting system with battery, battery charger and DC panel, exhaust system (incl. Exhaust system piping, stack along with supporting structure, Expansion bellows and Silencers complying to CPCB norms) and control panel / controller complying the following Type - Prime Rated Voltage rating - 6.6kV Power rating - 2250 kVA output at Site conditions Rated power factor - 0.8 Engine Type - Radiator shall be Engine Mounted Installation - Outdoor EDG shall be supplied with required accessories like Battery charger, Batteries, Control / AMF panel, Synchronization panel for Load control and Synchronization, NIS panel (Neutral isolating switch panel), local isolator, Fuel tank (Day tank), stack along with supporting structure and other accessories as required. Note 1:The UNIT RATE shall be inclusive of (not limited to) all including Packing and forwarding, Pre-Commissioning / Commissioning / Start-Up spares, Special tools and Tackles, Statutory Approvals Note 2: The Scope of supply shall include all equipment and materials required for the safe and efficient operation of the complete system, but not limited to the items listed in MR ref. TP-1ZZZA-ME-RFQ-3001_D1. Any equipment / material not listed herein but is necessary for smooth, safe & trouble free continuous operation and maintenance of the Emergency Diesel Generator (EDG) and other facilities; those required as part of good engineering practices shall be deemed to be included.
Emergency Diesel Generators (EDG) comprising of Diesel Engine (for each DG set) with air-intake system, lubrication system, governing system, fuel oil system (including 990L day tank for each DG set), cooling system, electrical starting system with battery, battery charger and DC panel, exhaust system (incl. Exhaust system piping, stack along with supporting structure, Expansion bellows and Silencers complying to CPCB norms) and control panel / controller complying the following Type - Prime Rated Voltage rating - 6.6kV Power rating - 2250 kVA output at Site conditions Rated power factor - 0.8 Engine Type - Radiator shall be Engine Mounted Installation - Outdoor EDG shall be supplied with required accessories like Battery charger, Batteries, Control / AMF panel, Synchronization panel for Load control and Synchronization, NIS panel (Neutral isolating switch panel), local isolator, Fuel tank (Day tank), stack along with supporting structure and other accessories as required. Note 1:The UNIT RATE shall be inclusive of (not limited to) all including Packing and forwarding, Pre-Commissioning / Commissioning / Start-Up spares, Special tools and Tackles, Statutory Approvals Note 2: The Scope of supply shall include all equipment and materials required for the safe and efficient operation of the complete system, but not limited to the items listed in MR ref. TP-1ZZZA-ME-RFQ-3001_D1. Any equipment / material not listed herein but is necessary for smooth, safe & trouble free continuous operation and maintenance of the Emergency Diesel Generator (EDG) and other facilities; those required as part of good engineering practices shall be deemed to be included.
Emergency Diesel Generators (EDG) comprising of Diesel Engine (for each DG set) with air-intake system, lubrication system, governing system, fuel oil system (including 990L day tank for each DG set), cooling system, electrical starting system with battery, battery charger and DC panel, exhaust system (incl. Exhaust system piping, stack along with supporting structure, Expansion bellows and Silencers complying to CPCB norms) and control panel / controller complying the following Type - Prime Rated Voltage rating - 6.6kV Power rating - 1500 kVA output at Site conditions Rated power factor - 0.8 Engine Type - Radiator shall be Engine Mounted Installation - Outdoor EDG shall be supplied with required accessories (but not limited to) like Battery charger, Batteries, Control / AMF panel, Synchronization panel for Load control and Synchronization, NIS panel (Neutral isolating switch panel), local isolator, Fuel tank (Day tank), stack along with supporting structure and other accessories as required. Note 1:The UNIT RATE shall be inclusive of (not limited to) all including Packing and forwarding, Pre-Commissioning / Commissioning / Start-Up spares, Special tools and Tackles, Statutory Approvals Note 2: The Scope of supply shall include all equipment and materials required for the safe and efficient operation of the complete system, but not limited to the items listed in MR ref. TP-1ZZZA-ME-RFQ-3001_D1. Any equipment / material not listed herein but is necessary for smooth, safe & trouble free continuous operation and maintenance of the Emergency Diesel Generator (EDG) and other facilities; those required as part of good engineering practices shall be deemed to be included.
Jakson Limited
Supernova Engineers Limited
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid