| 1 | L-1₹28.7 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹30.7 L+₹1.8 L (6.09%)Rejected-Finance | L-2 | Rejected-Finance BEING L-2 | |
| 3 | L-3₹32.3 L+₹3.4 L (11.8%)Rejected-Finance 01 KHUMRIYAL KUPWARA KHUMRIYAL KUPWARA KUPWARA JAMMU KASHMIR 193223 | KUPWARA | JAMMU AND KASHMIR | 193223 | L-3 | Rejected-Finance BEING L-3 | |
| 4 | L-4₹32.9 L+₹4.0 L (13.9%)Rejected-Finance | L-4 | Rejected-Finance BEING L-4 | |
| 5 | L-5₹33.6 L+₹4.7 L (16.2%)Rejected-Finance RAWALPORA WANABAL PATI YAYIL POST OFFICE SANAT NAGAR SRINAGAR 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-5 | Rejected-Finance BEING L-5 |
Tender Value
₹39.6 L
EMD Value
₹79,300
Closing Date
31 Aug 2022, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/O 56 APO
PROVN OF DRAINAGE SYSTEM MT SHED HARD STANDING VEHICLE PARKING REPAIR OF CEILING WALL PANELING WITH ELECTRIC FITTING IN CERTAIN BLDGS AT AWANTIPUR GRN UNDER GE 861 EWS
2022_MES_540322_1
GE 861EWS-38/2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹79,300
Yes
29 Sept 2022
23 Jul 2022
7 Sept 2022
23 Jul 2022
31 Aug 2022
6 Aug 2022
Amount
Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors & paving n.exc 15 cm thick (below or above ground level) complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store complete all as specified and directed.
Dismantling of timber scantling under 40 Sqcm, fixed in any position in fillet rails, posts rafters purlin etc complete all as specified and directed.
Dismantling timber scantling unframed 40 sq cm and over in section in any position, complete all as specified and directed.
Demolition wall and ceiling boards (fibre, Pulp, insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets & snap grid frame etc, complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and as directed.
15mm thick rendering on fair faces of brick or concrete surfaces in CM 1:6 finished even and smooth without using extra cement, complete all as specified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Glazed ceramic coloured tiles 450mm x 350mm x 7mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed.
80mm thick factory made machine pressed precast concrete, glossy finished coloured interlocking paver block with grey cement and pigment, any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006, M-40 grade, complete all as specified and directed.
Sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed.
25mm thick PCC 1:2:4, type B-0 (using 12.5 mm graded crused stone aggregate) as in floors to recieve floor finishes, complete all as specified.
75mm thick PCC 1:3:6 Type C-2 (40 mm graded stone aggregate) as in sub-floor, sub-base, floor and pavings, etc., complete all as specified and directed.
Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed.
Cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed.
MS TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed.
6mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in ceiling flat and sloping with nails to timber frame, complete all as specified and directed.
6mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in walls with nails to timber frame, complete all as specified and directed.
2nd class softwood, as in scantling and similar work, clean sawn, timber fixed in position, complete all as specified and directed.
2nd class hardwood plain fillets square/rectangular or triangular in section of sectional area exc 13 Sqcm but n exc 25 Sqcm, complete all as specified and directed.
2nd class hardwood plain fillets bull nosed splayed chamfered or rounded on one edge or face in section of sectional area not exc 3 Sqcm, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based plaind steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in in soft/loose soil, complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified.
PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in Surface Channels and drains, complete all as specified.
Rolled mild steel in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, complete all as specified and as directed.
Rolled mild steel in roof trusses (framed),trussed ,purlins,crane girders,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
Hard core of broken stone or boulders of guage n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Hard core of broken stone or boulders of guage exc 63mm but n. exc 100mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Rolling over hard core surface with 8 to 12 tonne power roller n exc 150mm compacted thickness, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement using extra cement including forms, moulds, mitered / stopped ends etc., complete all as specified and directed.
450mm bore reinforced concrete pipes, class NP3, laid and jointed complete with collars, complete all as specified and directed.
Precast cement concrete type 1:3: 6, type-C1 (20 mm graded aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set and jointed in CM 1:4, complete all as specified and directed.
Preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying three coats of white wash,complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-41 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No-41 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per serial item No 41 here-in-before but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
Switch piano flush button types 6 Amp, single pole, one way complete all as specified and directed.
Socket outlet, 3 pin, 6 Amps flush type, complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp, flush type universal, complete all as specified and directed.
Modular one way switch 6 Amp, 1 module, complete all as specified and directed.
Modular one way switch 16A, 1 module, complete all as specified & directed.
Modular socket outlet, 6A-2/3 pin combined 2 module, 230 volts complete all as specified and directed.
Modular socket outlet, 6A/16A-2/3 pin combined 2 module, 230 volts complete all as specified & directed.
Modular fan step regulator, 120W - 2 module, complete all as specified & directed.
Modular white cover plate with frame, 3 module, complete all as specified and directed.
Modular white cover plate with frame, 4 module, complete all as specified and directed.
Modular white cover plate with frame, 6 module, complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
S & F in repair stepped type electronic fan regulator flush type, AC 230 volts, duly ISI marked including connector on the existing sheet etc. as reqd., complete all as specified and directed.
S & F in repair LED lamp 9 W, complete all as specified and directed.
Supply, installation, testing and commissioning of decorative ultra slim linear LED in replacement of 20 Watt , 4' long lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack including LED tube complete with inbuilt electronic driver , PCB , connector block etc including connecting up with three core twisted flexible copper conductor cable with suitable size LED tube, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections, complete all as specified & directed.
MCB, SPN, AC, 240 volts "B" series capacity of 40 Amps, 10kA and making connections, complete all as specified & directed.
Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00, BEE 5 star rated with brushless direct current motor including taking down old unsv, complete all as specified and directed.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated copper conductor (Solid ) of size 10 Sqmm 2 core served with inner sheathing of PVC tape and overall PVC sheathed in service connections, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 13.50%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
BHAT CONSTRUCTIONS AND BUILFERS
M/S MIR AND CO
JANDOO AND CO.
FIRDOUS AHMAD BABA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .