Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC | ₹1.8 L | L1 | Accepted-AOC BIDDER IS L1. RECOMMENDED BY TC AND APPROVED BY COMPETENT AUTHORITY. |
| 2 | Rejected-Technical | - | - | Rejected-Technical Bidder is other than L1. Documents not evaluated. Bid REJECTED. |
| 3 | Rejected-Technical AT JAWAHAR NAGAR PO BERMO DIST BOKARO PIN 829104 JHARKHAND | BERMO | BOKARO | JHARKHAND | 829104 | - | - | Rejected-Technical Bidder is other than L1. Documents not examined. Bid rejected. |
| Sl No | Description | Qty | Unit | M/S JAI MAA ENTERPRISES L2 | CITY ELECTRICALS L3 | S KUMAR ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.01 | Erection of metallic pole (above 8 m and upto 10 m) in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. | 15 | no. | 3,825 ₹57,375 | 3,934 ₹59,010 | 3,624.78 ₹54,371.7 Lowest |
| 1.02 | Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. (14 span x 45 m x 2 wire) = 1260 m x 0.214 kg/m = 269.64 kg | 269.64 | kg | 122 ₹32,896.08 | 125 ₹33,705 | 115.42 ₹31,121.85 Lowest |
| 1.03 | Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required. | 15 | set | 645 ₹9,675 | 663 ₹9,945 | 610.93 ₹9,163.95 Lowest |
| 1.04 | Supplying and erection of 100 mm X 110 mm shackle insulator complete with G. I. Bolt, nuts and straps etc. as reqd. | 21 | set | 180 ₹3,780 | 186 ₹3,906 | 171.14 ₹3,593.94 Lowest |
| 1.05 | Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required | 5 | no. | 3,418 ₹17,090 | 3,515 ₹17,575 | 3,238.73 ₹16,193.65 Lowest |
| 1.06 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. (45 m x 2 wire x 8 span) x 0.214 kg/m = 154.08 kg + 16 no. Channel Iron = 7.14 kg x 16 = 114.24 kg; Total = 268.32 kg | 268.32 | kg | 40 ₹10,732.8 | 41 ₹11,001.12 | 37.81 ₹10,145.18 Lowest |
| 1.07 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. | 12 | no. | 1,216 ₹14,592 | 1,251 ₹15,012 | 1,152.21 ₹13,826.52 Lowest |
| 1.08 | Erection of light fittings on poles | 14 | no. | 184 ₹2,576 | 189 ₹2,646 | 174.13 ₹2,437.82 Lowest |
| 1.09 | Supply and providing of 2 x 1.5 sq. mm. Cu wire for connection of light fittings to poles and for control switches | 80 | metre | 38 ₹3,040 | 38.88 ₹3,110.4 | 35.82 ₹2,865.6 Lowest |
| 1.10 | Transporting manually Rail/ Tubular Pole from Dismantling Site to Working Site | 13 | no. | 525 ₹6,825 | 540 ₹7,020 | 497.5 ₹6,467.5 Lowest |
Tender Value
₹1.8 L
EMD Value
₹2,300
Closing Date
27 Feb 2023, 11:00 amClosed
P.E (EnM)
P.O of Bokaro Colliery.
Re-organisation of lighting O/H Lines in Haul Road due to development of Haul Road, under Bokaro Colliery, BnK Area.
2023_CCL_271638_1
PE(EnM)/Bokaro/ e-tender/22-23/ 43
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Bokaro Colliery.
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,300
4 Jul 2026
18 Feb 2023
28 Feb 2023
18 Feb 2023
27 Feb 2023
19 Feb 2023
18 Feb 2023 - 27 Feb 2023
Amount
Erection of metallic pole (above 8 m and upto 10 m) in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. (14 span x 45 m x 2 wire) = 1260 m x 0.214 kg/m = 269.64 kg
Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Supplying and erection of 100 mm X 110 mm shackle insulator complete with G. I. Bolt, nuts and straps etc. as reqd.
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. (45 m x 2 wire x 8 span) x 0.214 kg/m = 154.08 kg + 16 no. Channel Iron = 7.14 kg x 16 = 114.24 kg; Total = 268.32 kg
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Erection of light fittings on poles
Supply and providing of 2 x 1.5 sq. mm. Cu wire for connection of light fittings to poles and for control switches
Transporting manually Rail/ Tubular Pole from Dismantling Site to Working Site
Total impact of GST for the purpose of CTC
M/S JAI MAA ENTERPRISES
CITY ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .