| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC SAHEBPARA RAOD UPPER BAGDOGRA P O BAGDOGRA DISTRICT DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹34.7 L+₹4.4 L (14.5%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest bidder | |
| 3 | L3₹35.0 L+₹4.7 L (15.5%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest bidder | |
| 4 | L4₹37.5 L+₹7.2 L (23.7%)Rejected-Finance 93 618 A MOHANTA PARA WARD NO 19 PO DIST JALPAIGURI PIN 735101 | JALPAIGURI | WEST BENGAL | 735101 | L4 | Rejected-Finance Being other than lowest bidder | |
| 5 | L5₹38.0 L+₹7.6 L (25.2%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
5 Jun 2021, 4:00 pmClosed
CWE Bengdubi
Headquarters Commander Works Engineers Bengdubi, Post - Bengdubi Distt - Darjeeling (WB) PIN- 734424
SPECIAL REPAIRS TO LT PANELS, LT OH LINES TO LT UG CABLE AND 33 KVA INCOMMER BUSBAR BAY AT BENGDUBI MIL STATION UNDER GE BENGDUBI
2021_MES_441380_1
8099/B/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE BENGDUBI
As per tender documents
8 documents required · 8 mandatory
₹500
GE Bengdubi
₹68,000
18 Jun 2021
8 May 2021
10 Jun 2021
8 May 2021
5 Jun 2021
22 May 2021
Amount
Supplying, laying, jointing and testing XLPE insulated, armoured, heavy duty, electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 95 Sqmm x 3.5 core in trenches /along poles/on wall etc, complete all as specified and as directed Notes for item No 1. : (i) Excavation and earth work, sand cushioning, protection covers shall be measured and paid for separately. (ii) Unless otherwise directed by the GE, the cable shall be procured by the contractor in single length (as manufactured) to meet the actual length of cable as required at site. However, for payment purpose, the length actually ordered & laid shall be measured and paid for.
All as per item No 1.00 here-in-before but LT Cable of size 70 Sqmm x 3.5 Core.
All as per item No 1.00 here-in-before but LT Cable of size 10 Sqmm x 2 Core.
All as per item No 1.00 here-in-before but LT Cable of size 06 Sqmm x 2 Core.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5m in depth for laying of under ground cables/ pipes and not exceeding 10 Sqm on plan & 1.5 metre in depth for poles/independent holes etc, complete all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm thick in layers, complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
M& L for Sand cushioning in trenches for cushioning of underground cable including spreading, levelling, well ramming in layers not exceeding 25cm in thickness, complete all as specified and directed.
Material and labour for well burnt Sub-class 'B' old size bricks, best quality locally available laid flat, dry in trenches for cable protection, complete all as specified and as directed.
Supply and fixing GI tubing, light grade, 100mm bore for protection of cable under road crossing, across drain, along electric pole or floor /wall etc, complete all as specified and directed. Note for Item No. 10 : Excavation & Earthwork/Boring/ Drilling shall be measured & paid for separately. However the cost for provision of clamps made from mild steel flat of required size, bolts, nuts, washers etc (including painting of mild steel surfaces with 2 coats of aluminium paint over 1 coat of red oxide primer) for fixing of G.I. pipes with poles etc shall be deemed to be included in the quoted rate of above item.
All as per item No 10 above but 50 mm bore tubing.
Dismantling of existing Over Head Aluminium conductor steel reinforced, stretched over the poles etc, complete all as specifed and directed.
Dismantling of existing cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, fixed over the poles etc, complete all as specified and directed.
Dismantling of insulators of any grade, description and size from the poles etc, complete all as specified and directed.
Supply, providing and testing PVC Insulated, weather proof, FRLS, PVC sheathed cables with multistranded bright annealed copper conductor of size 1.5 Sqmm 3 core for connection of light fittings to pole light junction box, cable laid through & including PVC conduit pipe of 20mm dia, heavy grade duly fixed with provision of suitable MS clamps, bolts, nuts etc, also including taking down old ones, complete all as specified and directed.
S&F in repair and testing of factory made thermoplastic weather proof, street light junction box of size 230(L) x 170 (B) x 105 (D) mm with IP-65 protection having 01 Number DIN Rail for mounting of MC, also provided with 01 Number MCB, SP, 6 Amps, 10 KA breaking capacity, "C" curve & two openings with & including cable glands for termination of cable & fixing with the provision of suitable sized MS clamps etc to poles, complete all as specified and as directed.
Supply, Installing, Testing & Commissioning of CPRI approved, LT panel board, Feeder Pillar Box, "out-door type", Pedastal Type of required size to accomodate all of its components, accessories, items, factory fabricated & factory assembled, out of 3.15mm thick CRCA sheet, supporting frame made out of 50x50x5mm (minimum size) angle iron & MC 100mm (minimum size) in base, all the steel surfaces (internally as well as externally) shall be duly pre-treated with anti-corrosive coating & finally epoxy powder coated of tint grey-shade (RAL-7032), double door, front & back openable with locking arrangement, 4 side slanting canopy on roof top, the panel shall be having ventilation facility with provision of louvers for better heat dissipation, the panel shall be provided with suitable neoprene rubber gasket to make it completely weather, dust & vermin proof & degree of protection not less than IP-54, the panel shall have independent housing for each control switch gear & shall be accommodated with & including bus-bars, the panel shall be suitable for 3 Phase, 4 wire system, 50Hz, 415/440 volts grade electric supply, duly provided with multistraded internal wiring with not less than 2.5 sqmm copper conductor wire (with & including copper lugs of suitable sizes), also including making good the damaged/broken portion of foundation/plateform/plinth/blocks with CM 1:3/PCC 1:2:4 as per site requirement and also provided with the following accessories, components, items, complete all as specified and directed.:- (A) BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of pure copper conductor, 400 Amps rated; 03 Nos for phases and 01 No; 200 Amps rated; for Neutral, duly insulated with 1100 Volts grade, heat resistance & fire proof (HFFR), heat shrinkable, standard colour coded, sleeves & rigidly mounted on suitable sized "F" class epoxy insulators, non-hygroscopic, non-combustible, all internal connections from main bus-bars to MCCB's etc. (B) PROVISION FOR CABLE ENTRY/EXIT : Openings for cable entry/exit with & including cable grlands & copper lugs shall be provided in the bottom of panel for both incoming & out-going cables.
Supply, Installing, Testing & Commissioning of CPRI approved, LT panel board, Feeder Pillar Box, "out-door type", Pedastal Type of required size to accomodate all of its components, accessories, items, factory fabricated & factory assembled, out of 3.15mm thick CRCA sheet, supporting frame made out of 50x50x5mm (minimum size) angle iron & MC 100mm (minimum size) in base, all the steel surfaces (internally as well as externally) shall be duly pre-treated with anti-corrosive coating & finally epoxy powder coated of tint grey-shade (RAL-7032), double door, front & back openable with locking arrangement, 4 side slanting canopy on roof top, the panel shall be having ventilation facility with provision of louvers for better heat dissipation, the panel shall be provided with suitable neoprene rubber gasket to make it completely weather, dust & vermin proof & degree of protection not less than IP-54, the panel shall have independent housing for each control switch gear & shall be accommodated with & including bus-bars, the panel shall be suitable for 3 Phase, 4 wire system, 50Hz, 415/440 volts grade electric supply, duly provided with multistraded internal wiring with not less than 2.5 sqmm copper conductor wire (with & including copper lugs of suitable sizes), also including making good the damaged/broken portion of foundation/plateform/plinth/blocks with CM 1:3/PCC 1:2:4 as per site requirement and also provided with the following accessories, components, items, complete all as specified and directed.:- (A) BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of pure copper conductor, 300 Amps rated; 03 Nos for phases and 01 No; 150 Amps rated; for Neutral, duly insulated with 1100 Volts grade, heat resistance & fire proof (HFFR), heat shrinkable, standard colour coded, sleeves & rigidly mounted on suitable sized "F" class epoxy insulators, non-hygroscopic, non-combustible, all internal connections from main bus-bars to MCCB's etc. (B) PROVISION FOR CABLE ENTRY/EXIT : Openings for cable entry/exit with & including cable grlands & copper lugs shall be provided in the bottom of panel for both incoming & out-going cables.
Supply, Installing, Testing & Commissioning of CPRI approved, LT panel board, Feeder Pillar Box, "out-door type", Pedastal Type of required size to accomodate all of its components, accessories, items, factory fabricated & factory assembled, out of 3.15mm thick CRCA sheet, supporting frame made out of 50x50x5mm (minimum size) angle iron & MC 100mm (minimum size) in base, all the steel surfaces (internally as well as externally) shall be duly pre-treated with anti-corrosive coating & finally epoxy powder coated of tint grey-shade (RAL-7032), double door, front & back openable with locking arrangement, 4 side slanting canopy on roof top, the panel shall be having ventilation facility with provision of louvers for better heat dissipation, the panel shall be provided with suitable neoprene rubber gasket to make it completely weather, dust & vermin proof & degree of protection not less than IP-54, the panel shall have independent housing for each control switch gear & shall be accommodated with & including bus-bars, the panel shall be suitable for 3 Phase, 4 wire system, 50Hz, 415/440 volts grade electric supply, duly provided with multistraded internal wiring with not less than 2.5 sqmm copper conductor wire (with & including copper lugs of suitable sizes), also including making good the damaged/broken portion of foundation/plateform/plinth/blocks with CM 1:3/PCC 1:2:4 as per site requirement and also provided with the following accessories, components, items, complete all as specified and directed.:- (A) BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of pure copper conductor, 800 Amps rated; 03 Nos for phases and 01 No; 400 Amps rated; for Neutral, duly insulated with 1100 Volts grade, heat resistance & fire proof (HFFR), heat shrinkable, standard colour coded, sleeves & rigidly mounted on suitable sized "F" class epoxy insulators, non-hygroscopic, non-combustible, all internal connections from main bus-bars to MCCB's etc. (B) PROVISION FOR CABLE ENTRY/EXIT : Openings for cable entry/exit with & including cable grlands & copper lugs shall be provided in the bottom of panel for both incoming & out-going cables.
Supply, Installing, Testing & Commissioning of CPRI approved, LT panel board, Feeder Pillar Box, "Indoor type", Floor mounted Type of required size to accomodate all of its components, accessories, items, factory fabricated & factory assembled, out of 2.00mm thick CRCA sheet, supporting frame made out of 50x50x5mm (minimum size) angle iron & MC 100mm (minimum size) in base, all the steel surfaces (internally as well as externally) shall be duly pre-treated with anti-corrosive coating & finally epoxy powder coated of tint grey-shade (RAL-7032), double door, front & back openable with locking arrangement, the panel shall be provided with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-54, the panel shall have independent housing for each control switch gear & shall be accommodated with & including bus-bars, the panel shall be suitable for 3 Phase, 4 wire system, 50Hz, 415/440 volts grade electric supply, duly provided with multistraded internal wiring with not less than 2.5 sqmm copper conductor wire (with & including copper lugs of suitable sizes), also including making good the damaged/broken portion of foundation/plateform/plinth/blocks with CM 1:3/PCC 1:2:4 as per site requirement and also provided with the following accessories, components, items, complete all as specified and directed.:- (A) BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of pure copper conductor, 600 Amps rated; 03 Nos for phases and 01 No; 400 Amps rated; for Neutral, duly insulated with 1100 Volts grade, heat resistance & fire proof (HFFR), heat shrinkable, standard colour coded, sleeves & rigidly mounted on suitable sized "F" class epoxy insulators, non-hygroscopic, non-combustible, all internal connections from main bus-bars to MCCB's etc. (B) PROVISION FOR CABLE ENTRY/EXIT : Openings for cable entry/exit with & including cable grlands & copper lugs shall be provided in the bottom of panel for both incoming & out-going cables.
Supply, Installing, Testing & Commissioning of CPRI approved, LT panel board, Feeder Pillar Box, "Indoor type", Floor mounted of required size to accomodate all of its components, accessories, items, factory fabricated & factory assembled, out of 2.00mm thick CRCA sheet, supporting frame made out of 50x50x5mm (minimum size) angle iron & MC 100mm (minimum size) in base, all the steel surfaces (internally as well as externally) shall be duly pre-treated with anti-corrosive coating & finally epoxy powder coated of tint grey-shade (RAL-7032), double door, front & back openable with locking arrangement, the panel shall be provided with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-54, the panel shall have independent housing for each control switch gear & shall be accommodated with & including bus-bars, the panel shall be suitable for 3 Phase, 4 wire system, 50Hz, 415/440 volts grade electric supply, duly provided with multistraded internal wiring with not less than 2.5 sqmm copper conductor wire (with & including copper lugs of suitable sizes), also including making good the damaged/broken portion of foundation/plateform/plinth/blocks with CM 1:3/PCC 1:2:4 as per site requirement and also provided with the following accessories, components, items, complete all as specified and directed.:- (A) BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of pure copper conductor, 800 Amps rated; 03 Nos for phases and 01 No; 400 Amps rated; for Neutral, duly insulated with 1100 Volts grade, heat resistance & fire proof (HFFR), heat shrinkable, standard colour coded, sleeves & rigidly mounted on suitable sized "F" class epoxy insulators, non-hygroscopic, non-combustible, all internal connections from main bus-bars to MCCB's etc. (B) PROVISION FOR CABLE ENTRY/EXIT : Openings for cable entry/exit with & including cable grlands & copper lugs shall be provided in the bottom of panel for both incoming & out-going cables.
(C) OUTGOING: (a) Bus-bars O/G : 04 Nos : The bus-bars shall be made up of pure copper conductor, 300 Amps rated; 03 Nos for phases and 01 No; 150 Amps rated; for Neutral & rigidly mounted on suitable sized "F" class epoxy insulators, non-hygroscopic, non-combustible, all internal connections from main bus-bars to MCCB's etc. NOTES :- (a) All the live parts and joints shall be insulated with HRFP shrouds conforming to relevant IS. (b) Cost for provision of any other item (s)/ accessories/ components as per manufacturer instructions & as directed by the GE for the functional requirement and entire completion of the work/ item, shall also be deemed to be included in the quoted rate of above item. (c) Suitable openable doors shall be provided for all the operational switch gear & MCCB's and detacthable cover shall be provided on all other accessories. (d) The cost of making connection with provision of copper lugs with the existing cable shall also be deemed to be included in the quoted rate of above item. (e) The design & drawing, name of manufacturer of Panel, including the details & makes of the components, accessories, items of the Panel, shall be got approved by the contractor from the GE, before procurement of the Panel.
(C) OUTGOING: (a) Bus-bars O/G : 04 Nos : The bus-bars shall be made up of pure copper conductor, 300 Amps rated; 03 Nos for phases and 01 No; 150 Amps rated; for Neutral & rigidly mounted on suitable sized "F" class epoxy insulators, non-hygroscopic, non-combustible, all internal connections from main bus-bars to MCCB's etc. NOTES :- (a) All the live parts and joints shall be insulated with HRFP shrouds conforming to relevant IS. (b) Cost for provision of any other item (s)/ accessories/ components as per manufacturer instructions & as directed by the GE for the functional requirement and entire completion of the work/ item, shall also be deemed to be included in the quoted rate of above item. (c) Suitable openable doors shall be provided for all the operational switch gear & MCCB's and detacthable cover shall be provided on all other accessories. (d) The cost of making connection with provision of copper lugs with the existing cable shall also be deemed to be included in the quoted rate of above item. (e) The design & drawing, name of manufacturer of Panel, including the details & makes of the components, accessories, items of the Panel, shall be got approved by the contractor from the GE, before procurement of the Panel.
Supply, Installing, Testing & Commissioning of CPRI approved, LT panel board, Feeder Pillar Box, "out-door type", Pedastal Type of required size to accomodate all of its components, accessories, items, factory fabricated & factory assembled, out of 3.15mm thick CRCA sheet, supporting frame made out of 50x50x5mm (minimum size) angle iron & MC 100mm (minimum size) in base, all the steel surfaces (internally as well as externally) shall be duly pre-treated with anti-corrosive coating & finally epoxy powder coated of tint grey-shade (RAL-7032), double door, front & back openable with locking arrangement, 4 side slanting canopy on roof top, the panel shall be having ventilation facility with provision of louvers for better heat dissipation, the panel shall be provided with suitable neoprene rubber gasket to make it completely weather, dust & vermin proof & degree of protection not less than IP-54, the panel shall have independent housing for each control switch gear & shall be accommodated with & including bus-bars, the panel shall be suitable for 3 Phase, 4 wire system, 50Hz, 415/440 volts grade electric supply, duly provided with multistraded internal wiring with not less than 2.5 sqmm copper conductor wire (with & including copper lugs of suitable sizes), also including making good the damaged/broken portion of foundation/plateform/plinth/blocks with CM 1:3/PCC 1:2:4 as per site requirement and also provided with the following accessories, components, items, complete all as specified and directed.:- (A) BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of pure copper conductor, 800 Amps rated; 03 Nos for phases and 01 No; 400 Amps rated; for Neutral, duly insulated with 1100 Volts grade, heat resistance & fire proof (HFFR), heat shrinkable, standard colour coded, sleeves & rigidly mounted on suitable sized "F" class epoxy insulators, non-hygroscopic, non-combustible, all internal connections from main bus-bars to MCCB's, ACB's etc. (B) PROVISION FOR CABLE ENTRY/EXIT : Openings for cable entry/exit with & including cable grlands & copper lugs shall be provided in the bottom of panel for both incoming & out-going cables.
NOTES :- (a) All the live parts and joints shall be insulated with HRFP shrouds conforming to relevant IS. (b) Cost for provision of any other item (s)/ accessories/ components as per manufacturer instructions & as directed by the GE for the functional requirement and entire completion of the work/ item, shall also be deemed to be included in the quoted rate of above item. (c) Suitable openable doors shall be provided for all the operational switch gear, MCCB's & ACBs and detacthable cover shall be provided on all other accessories. (d) The cost of making connection with provision of copper lugs with the existing cable shall also be deemed to be included in the quoted rate of above item. (e) The design & drawing, name of manufacturer of Panel, including the details & makes of the components, accessories, items of the Panel, shall be got approved by the contractor from the GE, before procurement of the Panel.
Supply, Installing, Testing & Commissioning of CPRI approved, LT panel board, Feeder Pillar Box, "out-door type", Pedastal Type of required size to accomodate all of its components, accessories, items, factory fabricated & factory assembled, out of 3.15mm thick CRCA sheet, supporting frame made out of 50x50x5mm (minimum size) angle iron & MC 100mm (minimum size) in base, all the steel surfaces (internally as well as externally) shall be duly pre-treated with anti-corrosive coating & finally epoxy powder coated of tint grey-shade (RAL-7032), double door, front & back openable with locking arrangement, 4 side slanting canopy on roof top, the panel shall be having ventilation facility with provision of louvers for better heat dissipation, the panel shall be provided with suitable neoprene rubber gasket to make it completely weather, dust & vermin proof & degree of protection not less than IP-54, the panel shall have independent housing for each control switch gear & shall be accommodated with & including bus-bars, the panel shall be suitable for 3 Phase, 4 wire system, 50Hz, 415/440 volts grade electric supply, duly provided with multistraded internal wiring with not less than 2.5 sqmm copper conductor wire (with & including copper lugs of suitable sizes), also including making good the damaged/broken portion of foundation/plateform/plinth/blocks with CM 1:3/PCC 1:2:4 as per site requirement and also provided with the following accessories, components, items, complete all as specified and directed.:- (A) BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of pure copper conductor, 800 Amps rated; 03 Nos for phases and 01 No; 400 Amps rated; for Neutral, duly insulated with 1100 Volts grade, heat resistance & fire proof (HFFR), heat shrinkable, standard colour coded, sleeves & rigidly mounted on suitable sized "F" class epoxy insulators, non-hygroscopic, non-combustible, all internal connections from main bus-bars to MCCB's, ACB's etc. (B) PROVISION FOR CABLE ENTRY/EXIT : Openings for cable entry/exit with & including cable grlands & copper lugs shall be provided in the bottom of panel for both incoming & out-going cables.
NOTES :- (a) All the live parts and joints shall be insulated with HRFP shrouds conforming to relevant IS. (b) Cost for provision of any other item (s)/ accessories/ components as per manufacturer instructions & as directed by the GE for the functional requirement and entire completion of the work/ item, shall also be deemed to be included in the quoted rate of above item. (c) Suitable openable doors shall be provided for all the operational switch gear, MCCB's & ACBs and detacthable cover shall be provided on all other accessories. (d) The cost of making connection with provision of copper lugs with the existing cable shall also be deemed to be included in the quoted rate of above item. (e) The design & drawing, name of manufacturer of Panel, including the details & makes of the components, accessories, items of the Panel, shall be got approved by the contractor from the GE, before procurement of the Panel.
Supply, Installing, Testing & Commissioning of CPRI approved, LT panel board, Feeder Pillar Box, "Indoor type", Floor mounted of required size to accomodate all of its components, accessories, items, factory fabricated & factory assembled, out of 2.00mm thick CRCA sheet, supporting frame made out of 50x50x5mm (minimum size) angle iron & MC 100mm (minimum size) in base, all the steel surfaces (internally as well as externally) shall be duly pre-treated with anti-corrosive coating & finally epoxy powder coated of tint grey-shade (RAL-7032), double door, front & back openable with locking arrangement, the panel shall be provided with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-54, the panel shall have independent housing for each control switch gear & shall be accommodated with & including bus-bars, the panel shall be suitable for 3 Phase, 4 wire system, 50Hz, 415/440 volts grade electric supply, duly provided with multistraded internal wiring with not less than 2.5 sqmm copper conductor wire (with & including copper lugs of suitable sizes), also including making good the damaged/broken portion of foundation/plateform/plinth/blocks with CM 1:3/PCC 1:2:4 as per site requirement and also provided with the following accessories, components, items, complete all as specified and directed.:- (A) BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of pure copper conductor, 800 Amps rated; 03 Nos for phases and 01 No; 400 Amps rated; for Neutral, duly insulated with 1100 Volts grade, heat resistance & fire proof (HFFR), heat shrinkable, standard colour coded, sleeves & rigidly mounted on suitable sized "F" class epoxy insulators, non-hygroscopic, non-combustible, all internal connections from main bus-bars to MCCB's, ACB's etc. (B) PROVISION FOR CABLE ENTRY/EXIT : Openings for cable entry/exit with & including cable grlands & copper lugs shall be provided in the bottom of panel for both incoming & out-going cables.
NOTES :- (a) All the live parts and joints shall be insulated with HRFP shrouds conforming to relevant IS. (b) Cost for provision of any other item (s)/ accessories/ components as per manufacturer instructions & as directed by the GE for the functional requirement and entire completion of the work/ item, shall also be deemed to be included in the quoted rate of above item. (c) Suitable openable doors shall be provided for all the operational switch gear, MCCB's & ACB's and detacthable cover shall be provided on all other accessories. (d) The cost of making connection with provision of copper lugs with the existing cable shall also be deemed to be included in the quoted rate of above item. (e) The design & drawing, name of manufacturer of Panel, including the details & makes of the components, accessories, items of the Panel, shall be got approved by the contractor from the GE, before procurement of the Panel.
Dismantling existing unserviceable LT Panel Board/ Feeder Pillar Box/ Busbar Feeder Pillar Box (including dismantling of broken/damaged portion of foundation/platform/plinth/blocks etc) and disposing of the debris outside the premises, complete all as specified and directed.
Dismantling/ taking out existing unserviceable Earthing comprising of earthing plate/ electrode, cover, pit etc including necessary excavation & earth work and disposing of the debris out outside the premises, complete all as specified and directed.
M & L for cement concrete (1:3:6) type C-2 (using 40mm graded stone aggrgate) for foundation etc, complete all as specified and directed.
M & L for cement concrete (1:4:8) type D-1 (Using 40mm graded stone aggregates) for foundation etc, complete all as specified and directed.
Taking down old unserviceable existing XLPE insulated, heavy duty electric cables with aluminium conductor 11000 volts grade including aluminium lugs, pipes from the trenches /duct/ any other location, complete all as specified and as directed. Note:- Excavation and earth work shall be measured and paid for separately.
Supply, laying in trenches, existing ducts, any other location and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (hevy duty) with aluminium conductor 11000 volts grade (Earthed) of size 120 Sqmm 3 core, complete all as specified and directed. Note:- Excavatioin and earth work, sand cushioning, protection covers, protection pipes and jointing kits (including jointing materials) shall be measured and paid for separately.
Supply, jointing and testing, in repairs, cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint, complete with and including jointing materials and accessories suitable for 11KV XLPE insulated armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm 3 core, complete all as specified and as directed.
M&L for earthing complete of advance encapsulated compound based (CPRI tested) maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy coated). Zinc coated (80-100) microns with pure zinc(99.9%) & alloy coating (200-250) microns. Earthing system shall be conforming to IS-3034, the outer and inner pipe shall be 76.2mm & 41.9mm dia, 3 metre length Zinc coated with additional special alloy coating 300mm on the topside for additional protection of the terminal, annular space between the pipes being filled up with compact fill (CF) (Crystalline conductive compound). The compact fill (CF) mixture shall be machine pressed in the pipes and should not disintegrate or collapse when outer pipe corrodes. The inner pipe shall be extended with terminals for connectivity. The job includes digging the pits of 300mm diameter and refilling the same with 4 bags (25 Kgs/bag) electrodite/ conductolite back fill comopound (Ground Enhancer). The BFC shall be eco friendly, it shall not contain environmentally hazard materials having ROHS certification from NABL accredited lab. The earth pit shall also be provided with earth pit cover for protection and safe guard of terminals. The earth electrode (the main component of the earthing system) which is in direct contact with the ground shall be able to provide a means of releasing or collecting earth leakage current. The materials shall have good electrical conductivity & anti-corrosion property in wide rage of soil condition and testing on completion including replacing the existing soil with black soil for 80cm dia (Black soil shall be filled for total 80cm dia - 30cm dia of earth pit) (for the total depth of pit) around the 300mm dia pit, Make : ASHLOK Model –ASEEL-39 ZC & AC (zinc & Alloy) or equivalent as approved by the GE. complete all as specified and as directed. Note : Earth results obtained should be minimum 01 Ohm.
S&F Pin type, Polymer, grey, brown or green insulator including one galvnished mild steel spindle, two galvanised iron washers and one galvanied iron nut for 33 KV grade, complete all as specified and directed, MAKE: BHEL / Jaipuria Brothers / Pactil
S&F post type, porcelain, vitreous, white, brown or green insulator including one galvnished mild steel spindle, two galvanised iron washers and one galvanied iron nut for 33 KV grade, complete all as specified and directed. MAKE: BHEL / Jaipuria Brothers / Pactil
S&F in repair, 11 KV, 400 Amps, out door, tilting type, 9 insulators, manually operated, gang operated, air break off load disconnecting switch, triple pole, each consists of galvanized channel base HT insulator,non - ferrous knife and spring loaded contacts, arcing horn of adequate section to break magnetizing current of the transformer, horizontal GI pipe, heavy grade of adequate length for phase separation and for operation from ground level and operating handle, complete with locking arrangement on both ON and OFF position, all ferrous parts shall be hot dipped galvanized and non ferrous parts heavily tinned to withstand weather suitable for vertical mounting and conforming to IS 1818-1961, complete all as specified and as directed.
S&F in repair, lightening qrrestor, non-linear metal oxide type, complete with and incuduing all fittings, transmission class, discharge capacity 65 Kilo amps suitable for 33 KV, out door type and also including necessary connection and fittings all as per IS-3070 Part-III and IEC 1994, complete all as specified and as directed.
Taking down, repairing & overhauling of Air Break isolator with DO Fuse Unit, 33 KV rating, 400 Amp capacity, triple pole, mechanically operated, mounted on insulators and steel frame, installed vertically/ horizontally, replacement of broken/ worn out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contracts with conducting jelly, re-fixing the same after repairing & overhauling, including proper alignment, complete all as specified and as directed by GE. Note :- Cost of all the materials, labour and other elements to make the entire system serviceable shall be deemed to be included in the quoted rates and only payment for supply only of the items listed here-in-below shall be measured and paid for separately in case these are ordered and provided as directed.
Supply only female contact or fixed contact, heavy duty and high conductive metal, 400 Amp, suitable for 400 Amps capacity, 33 KV rated GO Switch, complete all as specified and directed by GE.
Supply only male or moving contact heavy duty and high conductive metal, 400 Amp, suitable for 400 Amps capacity, 33 KV rated GO Switch, complete all as specified and directed by GE
Supply only fiber glass tube with metallic fittings, both ends suitable for 33 KV DO Fuse Unit, complete all as specified and directed.
Supply only post type, porcelain, vitreous, white, brown or green insulator including one galvnished mild steel spindle, two galvanised iron washers and one galvanied iron nut for 33 KV grade, complete all as specified and directed. MAKE: BHEL / Jaipuria Brothers / Pactil
Supply, Fixing in repairs & Testing Horizontal Isolator, double break, rotating type, triple pole, mechanically operated, mounted on double post insulator and steel frame, outdoor type, provided with locking arrangement consisting of MS channel, HT type insulation in each phase, copper alloy high pressure assembly, operating rod of 40mm bore GI pipe, heavy grade suitable for 400 Amp, 33 KV grade, complete all as specified and directed.
Supply, fixing in repair & testing, 33 KV, single phase, out door, oil cooled, Current Transformer of ratio 200-100-50/5-5 Amp, class 1.0-5P, 10 burden, 15 VA insulation, 70 KV/170 KV, including first filling of transformer/ insulation oil conforming to IS : 335 and of dielectric strength 40 KV as per IS : 1866,complete all as specified and as directed.
Supply, fixing in repair & testing, 33 KV, 50 HZ, oil immersed, Potential Transformer for metering and protection, single phase, outdoor type, ratio 33000/110/^3 volt, rated burden 200 VA, accuracy class 3, Phase as per IS:3156 for protection with & including first filling of transformer/insulation oil conforming to IS : 335 and of dielectric strength 40 KV as per IS 1866, complete with & including all accessories, mounted with & including provision of new bolts, nuts, check nuts, washers etc on the existing fabricated steel structure and also making connection, complete all as specified and as directed.
Material and labour for preparation of old rusted steel exposed surfaces of HT swaged poles of 11m length, cross arms, brackets, cable protection pipe etc mounted on poles, applying one coat of synthetic enamel paint upto 1.2 metre height as per the existing pattern above the P.C.C coping & one coat of aluminium paint beyond 1.2 metre height (for the remaining exposed surfaces) of the poles as well as on the exposed surfaces of cross arms, brackets etc mounted on the poles, re-writing pole numbers and cutting vegetation growth all around the poles upto 1 metre radius, including replacement of self adhesive fluorescent colour tape as per existing pattern and size, complete all as specified and directed.
M & L removing of rust from the existing mild steel structure surfaces for the bus-bar bay No 3 & 4 installed in the 33 KV sub-station; each bay and bus-bars with & including cables protection pipes, clamps, panels, CT, PT, isolators, channels, angles of any description & all such like surfaces, thereafter preparation of the old painted surfaces and applying one coat of 1st quality aluminium paint including writing of the particulars/ nomenclature with white paint 10 cm height over a rectangular surface of black synthetic enamled paint, complete all as specified and directed.
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of preparation of exposed surfaces, application of one coat of red oxide primer and thereafter 2 coats of aluminium paint, complete all as specified and directed.
Boring/Drilling (horizontally) using ultrasound technique and necessary machine for passing 100mm bore pipe for protection of the cable at 1 metre depth in soil below existing road, pavement, hard standing etc without damaging the existing surfaces, getting out & disposal of soil to a distance not exceeding 50 metre from the site of work, complete all as specified and directed. Note : Cost for provision of pipes & cable not included in the scope of above item.
CHAKRABORTY AND SONS
Shree Ram Construction
SOMIK DAS
M/s Barua and Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .