Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.0 LAccepted-Finance 0 DHANA TEJA BARARI DHANA TEJA MATHURA MATHURA UTTAR PRADESH 281005 | MATHURA | UTTAR PRADESH | 281005 | L1 | Accepted-Finance L1 | |
| 2 | L2₹1.1 Cr+₹29.9 L (38.3%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹78 L
EMD Value
₹78,000
Closing Date
25 Oct 2023, 5:00 pmClosed
Superintending Engineer
EDC, Ayodhya
Increasing Capacity of Transformers at Different Capacity and Different Places and Construction of Transformer Plinth and Fencing Under Electricity Distribution Division-Ist Ayodhya
2023_MVVNL_848980_2
82 H(F)(W)/2023-24
Open Tender
Electrical Works
Item Wise
90 days
Ayodhya
As Per Tender Specifcation
2 documents required · 2 mandatory
₹3,540
Superintending Engineer, EDC
₹78,000
2 Nov 2023
17 Oct 2023
26 Oct 2023
17 Oct 2023
25 Oct 2023
17 Oct 2023
Amount
Part - A ( Material) Following Material Supplied by the Contractor:-
Copper L Piece for 400 KVA Transformer
Aluminum Lug (Long Barrel)
Holding Clamp with Nut and Bolt
Tainless unit
Nut & Bolt
Carriage including loading,unloading & Proper stacking of following Stock materials from store/departmental store to Dump site distance 0 to 20 Kms. (distance approx)
PCC Pole 8.5 Mtr. long
S.T. Pole 11 Mtr. long
11 KV XLPE Cable 3x120 sqmm
11 KV XLPE Cable 3x185 sqmm
11 KV Out door Cable Jointing kit 3x120
11 KV Out door Cable Jointing kit 3x185
L.T. XLPE Cable 1x240 sqmm
L.T. XLPE Cable 1x400 sqmm
AB Cable (3x95+1x70+1x16) sqmmq
AB Cable (3x120+1x95+1x16) sqmmq
ACSR Weasel Conductor
ACSR Rabbit Conductor
T/F 250 KVA
T/F 400 KVA
Other matching Materials
Dragging of ST/PCC Pole from dump site to pit site
Fabrication and Errection of Single Pole Support on ST/PCC Pole Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPo Norms. (Cost of clamps borne by contractor)
Fabrication and Errection of Double Pole Support on ST/PCC Pole Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPo Norms. (Cost of clamps borne by contractor)
Stringing, Sagging, Binding and jumpering of ACSR Weasel Conductor as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of ACSR Rabbit Conductor as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of AB Cable (3x95+1x70+1x16) sqmmq Conductor as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of AB Cable (3x120+1x95+1x16) sqmmq Conductor as per RESSPO Norms
Grouting and Binding of Stay with in 1:4:8 ratio with cement, sand and brick ballast including cost of all grouting materials as per RESSPO Norms
Earthing of Poles as per RESPO Norms
Mounting of 250 KVA Transformer as per RESSPO Norms.
Mounting of 400 KVA Transformer as per RESSPO Norms.
Laying of underground 11 KV 3x120 sq mm D/C XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Laying of underground 11 KV 3x185 sq mm XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Hanaging, Hosting & clamping of G.I. Pipe, channel, nut & Bolt 3x120 mm2 XLPE 11 KV cable as per RESSPO Norms (cost of all accessories will be borne by contractor)
Installation of Heat Shrinkable Type cable jointing kits Outdoor end Termination suitable for 11 KV XLPE cable 3x120 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Installation of Heat Shrinkable Type cable jointing kits Outdoor end Termination suitable for 11 KV XLPE cable 3x185 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Construction of Transformer Plinth size 2x2x1.5 including excavation of foundation, base concreting of 1:6:12 (Cement mortar of Ratio 1:4 foundation, CC in 1:4:8 ratio (Cement fine sand and brick ballast ) and RCC work with ratio 1:2:4 Cement, Coarse sand and Stone Grit of 20 mm gause as per RESSPO norms
FRP Fencing of Transformer Plinth with the help of wire mesh/Barbed wire after grouting proper size of angle as per RESSPO Norms. Inclusive of all material such as Wiremesh/Barbed Wire, Angle Flats, Nut Bolts etc.
Earthing by way of boring and lowering of "B" class G.I. pipe 50 mm dia 20 mtr. Long from ground upto the water lavel it will be connected to the G.S. Strip for T/F nutral connection the earth strip will be welded to the G.I. pipe the work also included top cap and clamps for pouring water the cost of all material will all labour and T n P etc. complete in all respect . (all the material will be supplied by the contractor.)
Connection of L.T. XLPE Cable Different Size & Different Places
Rect. Back old and used 100 KVA T/F
Rect. Back old and used 250 KVA T/F
M/S R.G. TRADERS
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .