| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹24.0 LAdmitted-Finance BAL VIDYA MODEL SCHOOL H NO 45 KH NO 74 19 BLOCK H LAXMI PARK NANGLOI NEW DELHI 110041 | WEST DELHI | DELHI | 110041 | -17.23% | ₹24.0 L | L1 | Admitted-Finance |
| 2 | L2₹24.1 LAdmitted-Finance | -16.88% | ₹24.1 L | L2 | Admitted-Finance |
| 3 | L3₹24.1 LAdmitted-Finance | -16.77% | ₹24.1 L | L3 | Admitted-Finance |
| 4 | L4₹24.3 LAdmitted-Finance | -16.07% | ₹24.3 L | L4 | Admitted-Finance |
| 5 | L5₹25.8 LAdmitted-Finance | -11.11% | ₹25.8 L | L5 | Admitted-Finance |
Tender Value
₹29.0 L
EMD Value
₹57,965
Closing Date
15 Jan 2026, 3:00 pmClosed
Executive Engineer
EE/HCD-9/DDA
Extension and Upgradation of Cafe Infrastructure at Baansera Park, Sarai Kale Khan.
2026_DDA_892928_1
44/EE/HCD-9/DDA/2025-26
Open Tender
Civil Works
45 days
As Per NIT
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹57,965
23 Jan 2026
7 Jan 2026
16 Jan 2026
7 Jan 2026
15 Jan 2026
7 Jan 2026
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge. All kind of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of formwork for: Foundations, footings, bases of columns
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and fixing PUF insulated sandwitch roof panel (size, shape and pitch of corrugation as approved by Engineer-in-charge) of 50mm (50/84mm) thich roofing panels having finsihed with 0.4mm thick TCT PPGI (Pre-Painted Galvanized Iron Sheets ) profile sheet on Top and 0.3mm thick PPGI shet micro ribs on bottom with roof insulation of 50 mm thick (i/c thichness of PPGI sheet on both side) Poly Urethane Foam (PUF) density of 40+/- 2 Kg/ M3 sandwiched between two fascias, insulation conforming to IS - 12432 Pt. III. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with High Pressure Laminate (HPL) Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of High pressure Laminate (HPL) cladding in pan shape in metalic colour of approved shades made out of 6mm thick High pressure laminate material consisting of Polyethylene Type LDPE mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The HPL cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts,washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with HPL cladding, cleaning and protection of the curtain wall with HPL cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with HPL Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2 mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area beyond 3 sq. metres
25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : Second class teak wood
GST Correction [email protected]
Cost Index@3% on DSR items
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.68 MB
NIT44.pdf
Tender Documents • 1.59 MB
BOQ_938550.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid