| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.5 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable | |
| 2 | 2₹34.2 L+₹2.7 L (8.49%)Rejected-Finance | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | 3₹38.1 L+₹6.6 L (21.0%)Rejected-Finance 4 9 359 P 14 BESIDE SAI BABA TEMPLE RTC COLONY HAYATH NAGAR HYDERABAD 501 505 | HYDERABAD | HAYATH NAGAR | TELANGANA | 501505 | 3 | Rejected-Finance Not being the lowest bidder | |
| 4 | 4₹38.1 L+₹6.6 L (21.1%)Rejected-Finance | 4 | Rejected-Finance Not being the lowest bidder | |
| 5 | 5₹38.2 L+₹6.7 L (21.3%)Rejected-Finance H NO 8 7 66 PLOT NO 76 VENTURE 2 HASTINAPURAM CENTRAL HYDERABAD 500 079 | HYDERABAD | HYDERABAD | TELANGANA | 500079 | 5 | Rejected-Finance Not being the lowest bidder |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
26 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIRS REPLACEMENT OF STREET SECURITY LIGHTS AND MISCELLANEOUS EM WORKS UNDER GE I RND RCIHYDERABAD
2022_MES_534236_1
8710
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE(I) R AND D RCI, HYDERABAD
MES enlisted Class D category b i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹95,000
Yes
30 Aug 2022
28 Jun 2022
2 Aug 2022
28 Jun 2022
26 Jul 2022
12 Jul 2022
Amount
Bailing out sewage water and cleaning the collection sump, clarifier sump and Aerator for STP No1 of capacity 100Cum/day including complete removal of silt/sludge /dirt accumulated at bottom and waste water to a distance not less than 100m, cleaning inner walls and bottom of sump with wire brush complete all as specified and directed.
All as per item No 1 above but for STP No 2 of capacity 400Cum/day
All as per item No 1 above but for STP No 3 of capacity 75Cum/day
Note for item No 1 to 3: Quoted rate shall deemed to be include all T&P for transportation required for disposal of sludge/dirt away from the site including safety precautions as specified by local municipal authorities.
Removing old filter media complete from sludge drying beds and disposing off as per local Municipal regulations, scraping the internal surfaces of sludge drying beds with wire brush, cleaning with bleaching powder slurry, cleaning with fresh water including applying one coat of white wash on external surface of sludge drying bed and re-filling up with new filter media in layers all as per manufacturers recommendations/ existing and commissioning complete all as directed. Note: New filter media will be measured and paid separately as 'Supply only'.
Supply only filter media of 40mm graded stone aggregate for sludge bed complete all as specified.
All as per item No 5 above but 20mm size.
All as per item No 5 above but 10mm size pebbles.
Supply only clean natural river sand.
M&L, removal and replacement of existing Aerator fan blades and Clarifier fan blades, carrying out necessary repair work in patches to platform bridge in cement mortar 1:3, carrying repairs to shutter for smooth functioning etc., for the Sewage Treatment Plant at STP No 2 all as required at site complete all as directed.
M&L, painting the entire Sewage Treatment Plant, STP No I including Aerator Clarifier/Gear box, panel shutters and pipes complete with one coat of synthetic enamel paint including preparation of surfaces complete all as specified and directed.
All as per item No 10 above but for STP No 2.
All as per item No 10 above but for STP No 3. Note for item No 1 to 12: Quoted rate shall deemed to include cost of working in foul conditions and taking all necessary precautions to personnel working under foul conditions.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes/cables/poles etc., and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and exceeding 1.50m depth for foundation, for laying of poles etc., and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L, PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of poles, filling and mass concrete complete all as specified and directed.
M&L, PCC 1:2:4, type B-1 using 20mm graded stone aggregate as in coping of poles including necessary formwork and other similar works complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning of 3.5core 25Sqmm, 1100 volts grade, LT XLPE insulated, PVC sheathed as per IS-7098 (Part-I), 1988 galvanized steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including disconnecting and taking down unserviceable cable complete all as specified and directed. Note: Earthwork Excavation, sand cushioning, cable covers, GI pipe and cable protection will be measured and paid separately.
Supply and spreading natural river sand of approved quality for cushioning of cable laid in trenches including compacting and leveling complete all as specified and as directed Note: Punned thickness will only be measured and paid.
Supply and laying un reinforced precast concrete cable cover, class LV Type 1, size 250mm x 150mm x 40mm, laid flat adjacent to each other, perpendicular to cable in trenches for protection of cable complete all as directed.
S&F, 40mm dia GI pipe light grade fixed to walls or laid in trenches etc., for protection of earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls complete all as specified and directed.
Cutting of existing bituminous/PCC road or flooring/ plinth protection, for laying of GI pipe in road intersection for passing of LT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as directed.
Supply and laying or fixing or passing through pipe, 3 core 4Sqmm nominal cross section, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed in service connections including taking down unserviceable cable complete all as specified and directed.
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9 metre long) complete including 2 coats of aluminium paint over a coat of primer on all exposed surfaces and tarring with black bituminous paint to embedded portion in PCC and providing 3 No of 15cm wide circular bands in black & yellow paint starting from 1.0m above coping at a gap of 15cm in between 2 bands and numbering of pole in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" wide including taking down old unserviceable pole of any type complete all as specified and directed.
Note: 1. Excavation and earth work shall be measured and paid separately. 2. PCC foundation and coping shall be measured and paid separately.
S&F in repairs, electrically operated digital timer switch DIN type daily/weekly programmable every 1 minute, with backup of 6 years, 28 memory locations, current capacity 16A, weekly program, with 1 changeover (CO), total 28 programs for street light suitable to operate on 230Volts complete all as specified and directed. Make: IndoAsian CAT No TDA43110 or equivalent in Legrand/Siemens/Schneider
S&F in repairs, bracket suitable for street light fitting made out of 40mm dia GI tube light grade 1.5m long bent to shape, fixed with necessary nuts bolts and a pair of clamps made of 32 x 6mm flat iron complete all as specified and directed.
S&F in repairs, hot pressed moulded SMC junction box of internal size 250 x 200 x 100mm, IP 55 with integrated membranes / metric knockouts for cable entry with terminals and arrangement for incoming and outgoing 3 phase 4 wire system with R,Y,B & N studs and control for incoming and outgoing cables, 'D' clamps made of flat iron 25 x 3mm, suitable to pole of any size including bolts nuts and washers etc., complete all as specified and directed.
Make: Sintex CAT No GSJB 2520 or equivalent in Hensel as approved by GE Note: The unit rate quoted shall be deemed to include for incoming & outgoing cables glands & lugs of size upto 25Sqmm 4 core.
S&F in repairs, ML 2, 3 pole contactor AC3 rating of 32Amps for complete all as specified. Make: L&T CAT No SS90701 or techno commercially equivalent in Siemens/Legrand/ABB /Schneider/C&S
S&F in repairs, ML 4, 3 pole contactor AC3 rating of 70Amps for complete all as specified. Make: L&T CAT No SS90910 or techno commercially equivalent in Siemens/Legrand/ABB /Schneider/C&S
M&L, Cleaning the steel tubular poles of 9/11 metres long of any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of aluminum paint over a coat of red oxide primer and writing of MES No on pole with emulsion black paint complete all as specified and directed.
M&L, Stickering of any type of street light pole with A1 graded radium strip of 100mm width three colour red, Yellow and green around the pole with 100mm gap in each strip at a distance of 1.1 metre high from the ground level complete including white wash to the coping and marking of pole numbers with emulsion black paint complete all as directed.
S&F in repairs LED driver suitable for 90W street light fittings complete all as specified and directed.
S&F in repairs LED driver suitable for 120W street light fitting complete all as specified and directed.
S&F in repairs LED driver suitable for 140W street light fittings complete all as specified and directed. Make for item No 33 to 35: Philips/Wipro/Havells Note for item No 33 to 35: Quoted rate shall deemed to include cost of any accessories for proper fixing of LED driver to fitting including hydraulic ladder or aerial access platform mounted on vehicle for replacement.
M&L, dismantling completely from the base and re-erection of 20m long high mast system with the help of suitable equipment, tools and plants, checking of winch motor operation and complete lubrication, carrying out repairs to lantern carriage, checking wire rope & pulleys, and re wiring of luminaries with existing size cable complete all as per manufacturers instructions and as directed.
The quoted rate shall deemed to include cost of minor repairs as decided by Accepting Officer.
Necessary spares which are required will be measured and paid for separately under relevant items.
Supply only, mild steel wire rope of 6mm dia, 97/19 gauge to fix high mast lantern and two point suspension mechanism complete all as specie fed and directed.
Supply only 5core 4Sqmm PVC insulated and FR PVC round sheathed, copper conductor (flexible) industrial cable, 1100Volts, ISI marked complete all as specified.
S&F in repair, 90W high efficient LED Street light fixture, single piece aluminum pressure die cast housing (LM6 alloy), Luminaire system efficacy ≥135 lm/W, System lumens 12200lm, high purity polycarbonate/toughened glass diffuser, with silicon gaskets for IP66 (No glue) protection, IK07, surge protection not less than 10KV, IEC 60598 to be followed, driver efficiency >85%, power factor >0.95, THD ≤10%, driver make must be as luminares, LED used to be SMD LED, secondary optics is must for better light distribution, LED Type for better color matching and to avoid color shift with LED binning as per ANSI standard, LED Makes: Nichia/ Cree/ Osram/ Philips Lumiled, colour rendering index CRI >70, temperature range 0 to 45 degree centigrade, CCT 5700K, lifetime of LED 50000 hours @ L70 B50 (As per TM21), photo biological safety report as per IEC 62471, voltage range 100-300V AC and safety on low voltage/high voltage, BIS R No. is mandatory and name of the company or logo must be embossed for LED light fixtures/drivers, submission of LM79, LM80 certification & TTR before claiming payment, Fixture shall be fitted to bracket 20 to 50mm dia complete all as specified and directed. Make: Havells Model No ENDURAPEARLPLUSSL 90WLED757PASYTOPCASTCC or PHILIPS Model No BRP409 LED115 CW SLA FG PSU GR V2 or Techno commercially equivalent in Wipro.
S&F in repairs, 60W high efficient LED Street light fixture, single piece Aluminum Pressure Die Cast Housing( LM6 Alloy) Luminaire system efficacy >125lm/W, System Lumens 7500lm, high purity polycarbonate/glass diffuser, with silicon gaskets for IP66 (No Glue) protection, IK07, name of the company or logo must be embossed, IEC 60598 to be followed, driver efficiency >88%, power factor > 0.95, THD ≤10%, driver make must be as luminares, LED used to be SMD LED, secondary optics is must for better light distribution, LED Type for better color matching and to avoid color shift with LED binning as per ANSI standard, LED Makes: Nichia/ Cree/ Osram/ Philips Lumiled, , colour rendering index CRI >70, temp range 0 to 45 degree centigrade, CCT: 6500K, Lifetime of LED 50K hours @L70 B50 (As per TM21), photo biological safety report as per IEC 62471, Voltage range 120-270V AC and safety on low voltage/high voltage, BIS R No. is mandatory and name of the company or logo must be embossed for LED light fixtures/drivers, submission of LM79, LM80 certification & TTR before claiming payment, Fixture shall be fitted to bracket of 20 to 50mm dia complete all as specified and directed. Make: Philips Model No.BRP062 LED 68 CW SLA S1 PSU or Techno commercially equivalent in wipro or Crompton
S&F in repairs, 150W high efficient LED Flood light fixture, aluminum pressure die cast housing (ADC12 alloy) along with mounting bracket for aiming, System lumens 16500lm, Luminaire system efficacy ≥110lm/W, toughened glass diffuser, with silicon gaskets for IP67 (No glue) protection, IK07, surge protection 10KV, IEC 60598 to be followed, driver efficiency >85%, power factor > 0.95, THD ≤10%, colour rendering index CRI >70, temperature range 0 to 45 degree centigrade, CCT: 5700K, LED Makes: Nichia/ Cree/ Osram/ Philips Lumiled, lifetime of LED 50000 hours @ L70 B50 (As per TM21), photo biological safety report as per IEC 62471, voltage range 140-270V AC and safety on low voltage/high voltage BIS R No. is mandatory and name of the company or logo must be embossed for LED light fixtures/drivers, mounting using adjustable mild steel cradle of 4mm thick with stainless steel angular dial for precise angular mounting of fixture, submission of LM79, LM80 certification & TTR before claiming payment complete all as specified and directed. Make: Havells Model No JETAIRISFLS150WLED 757PSYMLTG or Philips Model No BVP192 LED160 CW NB FG GR PSU or Techno commercially equivalent in Wipro.
S&F in repairs, 100W high efficient LED Flood Light fixture, aluminum pressure die cast housing (LM24) along with mounting bracket for aiming, System lumens not less than 12200lm, Luminaire system efficacy ≥122lm/W, toughened glass diffuser, with silicon gaskets for IP66 (No glue) protection, IK07, surge protection 10KV, IEC 60598 to be followed, driver efficiency >85%, power factor > 0.9, THD ≤10%, colour rendering index CRI >70, temperature range 0 to 45 degree centigrade, CCT: 5700K , LED used to be SMD LED, secondary optics is must for better light distribution, LED Makes: Nichia/ Cree/ Osram/ Philips Lumiled, lifetime of LED 50000 hours @ L70 B50 (As per TM21), photo biological safety report as per IEC 62471, voltage range 140-270V AC and safety on low voltage/high voltage, BIS R No. is mandatory and name of the company or logo must be embossed for LED light fixtures/drivers, mounting using adjustable mild steel cradle of 4mm thick with stainless steel angular dial for precise angular mounting of fixture, submission of LM79, LM80 certification & TTR before claiming payment complete all as specified and directed. Make: Havells Model No JETAIRISFLP100WLED 757ARNBLTG or Philips Model No BVP192 LED110 CW HO NB FG GR PSU or Techno commercially equivalent in Wipro.
S&F in repairs, 50W LED Flood light luminarie, aluminium pressure die cast housing along with mounting bracket, System lumens 5000lm, CRI>70, driver efficiency >85%, PF>0.90, surge protection upto 4KV complete all as specified and directed. Make: Havells CAT No JETA QUANTOPLUSFLP50WLED 757SYMLENS or Wipro CAT No LF9-471-060--XX or Philips CAT No BVP 140 LED50 CW PC WB
S&F in repairs, Post Top fixture not less than 25W high efficiency, single piece aluminum pressure die cast housing/ spun aluminium canopy & polycarbonate diffuser with Luminaire system efficacy not less than 70lm/W and System lumens output >2600lm, CRI>70, surge protection upto 10KV, TDH<10% at full load complete all as specified and directed. Make: Havells CAT No CORALPT35WLED 757PSYMTOPC or Philips CAT No BGP 300 LED28 757 PSU PC IN S1 or techno commercially equivalent in Wipro
SUN LIGHT HOUSE
SHRI GANESH ENTERPRISES
Richcon Engineers
M/s ANUSHA ENTERPRISES
SHANTI MARKETING AND SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .