Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹39.1 L
EMD Value
₹78,200
Closing Date
22 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
63 days
Expenditure
Revenue
REVENUE
11 conditions · 8 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor (5) For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Proposal for rectification of Split Air Conditioners installed in S&T locations in Chennai division.
ME-29-II-REV-OT-269-2026~SR
ME-29-II-REV-OT-269-2026
Open
Works - General
90 Days
Chennai, Tamil Nadu
₹0
₹78,200
30 Sept 2026
30 Sept 2026
8 Oct 2026
41 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 39,10,563 | ||
| — | — | — | Above/ 204000.00 Below/P | ||
| Water servicing of existing 1.5 TR split AC indoor and outdoor units, including cleaning of indoor and outdoor coils, casing (shell), and filters using standard industrial graded foam cleaning solution and water complete in all respects. | — | 102.00 | — | — | |
| — | — | — | Above/ 232500.00 Below/P | ||
| Water servicing of existing 2.0 TR split AC indoor and outdoor units, including cleaning of indoor and outdoor coils, casing (shell), and filters using standard industrial graded foam cleaning solution and water complete in all respects. | — | 93.00 | — | — | |
| — | — | — | Above/ 414750.00 Below/P | ||
| Leak testing, charging the nitrogen gas, vacuum testing, charging of refrigerant gas ( R22/32/410A/suitable for existing plants as per OEM recommendation) including all consumables suitable for AC Plant (1.5 Ton) | — | 79.00 | — | — | |
| — | — | — | Above/ 294000.00 Below/P | ||
| Leak testing, charging the nitrogen gas, vacuum testing, charging of refrigerant gas ( R22/32/410A/suitable for existing plants as per OEM recommendation) including all consumables suitable for AC Plant (2 Ton) | — | 42.00 | — | — | |
| — | — | — | Above/ 222750.00 Below/P | ||
| Releasing the defective compressor and supplying, fixing, and commissioning a new compressor confirming to IS:10617:2018 or latest compatible for existing 1.5 to 2.0 TR AC plant , including leak testing with nitrogen, vacuum testing, refrigerant gas charging, and all necessary consumables, complete in all respects as per site conditions. | — | 25.00 | — | — | |
| — | — | — | Above/ 213444.00 Below/P | ||
| Supply and replacement of the defective PCB board of an existing inverter/non- inverter type split AC indoor unit (1.5 to 2.0 TR capacity) with a new compatible PCB board, including testing, commissioning, and all necessary consumables, complete in all respects as required. | — | 44.00 | — | — | |
| — | — | — | Above/ 300960.00 Below/P | ||
| Supply and replacement of the defective PCB board of an existing inverter/non- inverter type split AC outdoor unit (1.5 to 2.0 TR capacity) with a new compatible PCB board, including testing, commissioning, and all necessary consumables, complete in all respects as required. | — | 32.00 | — | — | |
| — | — | — | Above/ 8712.00 Below/P | ||
| Supply and replacement of the defective condenser fan blade of existing window/split AC plant of 1.5 to 2.0 TR capacity with a new compatible fan blade, including dismantling, installation, testing and commissioning, and all necessary consumables, complete in all respects as required. | — | 22.00 | — | — | |
| — | — | — | Above/ 13740.00 Below/P | ||
| Supply and replacement of the defective 36/50 MFD capacitor of an existing split air- conditioner with a new compatible capacitor, including removal of the defective capacitor, installation of the new capacitor, testing and commissioning, complete in all respects as required. | — | 30.00 | — | — | |
| — | — | — | Above/ 61380.00 Below/P | ||
| Supply and replacement of the defective condenser fan motor of an existing window/split AC plant of 1.5 to 2.0 TR capacity with a new compatible fan motor, including dismantling of the defective motor, installation of the new motor, testing and commissioning, and all necessary consumables, complete in all respects as required. | — | 31.00 | — | — | |
| — | — | — | Above/ 18612.00 Below/P | ||
| Supply and replacement of defective contactor/relay suitable for the existing Split Air-Conditioner, of compatible rating and specification, including removal of the defective unit, installation, testing and commissioning, complete in all respects as required. | — | 47.00 | — | — | |
| — | — | — | Above/ 193200.00 Below/P | ||
| Supply, laying, testing and commissioning of suction and discharge pipe for 2 Ton AC of the following dimensions: 5/8inch and ¼ inch (set). | — | 300.00 | — | — | |
| — | — | — | Above/ 178200.00 Below/P | ||
| Supply, laying, testing and commissioning of suction and discharge pipe for 1.5 Ton AC of the following dimensions: 1/2inch and ¼ inch. | — | 300.00 | — | — | |
| — | — | — | Above/ 61875.00 Below/P | ||
| Supply and replacing of defective blower fan motor for split AC plant (for 1.5 to 2 Ton) with new a new compatible fan motor, including dismantling of the defective motor, installation of the new motor, testing and commissioning, and all necessary consumables, complete in all respects as required. | — | 25.00 | — | — | |
| — | — | — | Above/ 265500.00 Below/P | ||
| Supply, installation, testing and commissioning of digital cyclic timer, suitable for Split Air-Conditioner up to 2 TR capacity, suitable for 230 V AC supply, with voltage range of 90-440 V and rated current of 30 A, wall-mountable or installable at any other suitable location as directed by the Section Engineer-in-Charge, housed in a metal enclosure, complete with all necessary accessories, connections and commissioning, as required. | — | 100.00 | — | — | |
| — | — | — | Above/ 504570.00 Below/P | ||
| Supply, installation, testing and commissioning of 5 kVA Double Booster digital voltage stabilizer for Split Air-Conditioner up to 2 TR capacity, suitable for single-phase AC supply, with working input voltage range of 130-300 V, power input range of 140-270 V and regulated output voltage range of 200-270 V, incorporating solid-state circuitry, toroidal transformer technology, intelligent time-delay and safety protection features, complete with all necessary accessories, connections and commissioning, as required. | — | 110.00 | — | — | |
| — | — | — | Above/ 344370.00 Below/P | ||
| Supply of 20A, DP, MCB conforming to IS/IEC:60947 or latest along with IP 30 rated - Metal door Enclosure conforming to IEC 61439-1 & 3 or latest suitable for surface and flush mounting and available in CRCA sheet steel, RAL 9003,powder coated with and erection, testing and commissioning of the same using all fixing arrangements along with all incoming and outgoing cabling termination works complete as per directions of Section Engineer in charge at site. | — | 195.00 | — | — | |
| — | — | — | Above/ 166000.00 Below/P | ||
| Supply and drawing of inside mains using 2 runs of 2.5 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] Fire Retardant Low Smoke PVC insulated unsheathed multi-stranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid vide item No:19 below complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 2.5 sq. mm copper conductor are taken as 1m for quantity purpose. | — | 2000.00 | — | — | |
| — | — | — | Above/ 138000.00 Below/P | ||
| Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] | — | 2000.00 | — | — | |
| — | — | — | Above/ 74000.00 Below/P | ||
| Supply and Drawing of earth wire using 1.5 sq.mm Fire Retardant Low Smoke PVC insulated unsheathed multi-stranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly along wires vide item No's 18 above or elsewhere complete in a manner as directed by Senior Section Engineer in charge at site. | — | 2000.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Checklistlessthan50Lakh.pdf
ATTACHMENT
GCCandACS1-12.pdf
ATTACHMENT
ImportantinstructionstoTenderers.pdf
ATTACHMENT
ModelformofBGbondwithinstructions.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
Payment_clause_for_LED_luminaries_and_BLDC_fansasper2026.pdf
ATTACHMENT
StandardGuaranteecertificateformat.pdf
ATTACHMENT
Undertakings.pdf
ATTACHMENT
Specificationspecialconditionforwiring.pdf
ATTACHMENT
MCBDrawing.pdf
ATTACHMENT
GeneralinstructionstoTenderers_1.pdf
ATTACHMENT
Special_conditions_of_Contract_Electrical.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .