Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.3 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹25.4 L+₹1.5 L (6.17%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹29.4 L+₹5.5 L (22.8%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹30.2 L+₹6.3 L (26.2%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹31.0 L+₹7.1 L (29.6%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
4 May 2022, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
CERTAIN PETTY REPAIRS TO WIRING, FITTING, FIXTURES AND REPAIR / MAINT OF COOLING APPLIANCES AND REPAIR / MAINT / OVERHAULING TO DG SETS, BATTERY BANK AND ALLIED ITEMS AT MIRAN SAHIB UNDER GE JAMMU
2022_MES_517453_1
GEJC-05/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹62,000
Yes
1 Jul 2022
9 Apr 2022
6 May 2022
9 Apr 2022
4 May 2022
22 Apr 2022
Amount
Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid / steel conduit and into existing CI / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per Serial item No 2.00 here-in-before but for one 5 pin socket outlet 5 amps on the same board complete all as specified and as directed.
Description all as per Serial item No 2.00 here-in-before but for one 5 pin socket outlet, 5 amps, independent complete all as specified and as directed.
Description all as per Serial item No 2.00 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including new CI / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per Serial item No 6.00 here-in-before but for 5 Amp socket outlet on same board complete all as specified and as directed.
Description all as per Serial item No 6.00 here-in-before but for socket outlet 5 Amps independent board complete all as specified and as directed.
Description all as per Serial item No 6.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Description all as per Serial item No 6.00 here-in-before but drawn through and including new surface conduit PVC rigid non-metallic conduit 20 mm dia for socket outlet 5 amp independent board complete to accomodate the accessories for PVC gang box complete all as specified and as directed.
Description all as per Serial item No 6.00 here-in-before but drawn through and including new surface conduit PVC rigid non-metallic conduit 20 mm dia for socket outlet 15 amp independent board complete to accomodate the accessories for PVC gang box complete all as specified and as directed.
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 Volts double door complete all as specified and as directed. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 Volts double door complete all as specified and as directed. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 Volts double door complete all as specified and as directed. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed magnetic setting of capacity 125 Amps 16 KA complete all as specified and as directed.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement of SPN 32 Amp rating 240 V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement of SPN 40 to 63 Amp rating 240 V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement of 415 V 10KA 'B' curve TPN 40 to 125 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement for switch piano, flush type single pole one way 5 Amp, 240 Volts complete all as specified and as directed.
Supply and fixing in replacement for switch piano, flush type single pole one way 15 Amps, 240 Volts complete all as specified and as directed.
Supply and fixing in replacement for socket outlet 2 in 1, 3 pin, 5 A complete all as specified and as directed.
Supply and fixing in replacement for socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete all as specified and as directed.
Supply and fixing in replacement for switch socket outlet combined 5 pin 5 amp flush type, 240 Volts complete all as specified and as directed.
Supply and fixing in replacement for switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 Volts complete all as specified and as directed.
Supply and fixing in replacement for bell push, flush type single pole, 5 Amp, 240 Volts complete all as specified and directed.
Supply and fixing in replacement for ceiling rose 3 terminal surface type complete all as specified and as directed.
Supply and fixing in replacement for lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Supply and fixing in replacement for self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
Supply and fixing in replacement for LED lights fitting 1x 20W, 220 V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts, 50 Hz complete all as specified and as directed.
Supply and fixing in replacement of LED light fitting mirror type with high output diffuser 2 feet, 10 Watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in replacement bulk head luminaries IP-65 with opal diffuser 10 Watt, 230 Volts LED type complete with 10 watt LED Bulb complete all as specified and as directed.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35 / 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
Supply and fixing in replacement calling bell Ding Dong / buzzer AC 230 Volts, single pole complete all as specified and as directed.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 2.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 1.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion including taking down old unserviceable earthing complete with galvanised mild steel earth plate electrode complete all as specified and as directed.
Supply and fixing in replacement unserviceable wooden / CI sunken box with new CRCA pressed steel terminal box of size 7 X 4' including taking down old complete with cemented and patch work complete all as specified and as directed.
Supply and fixing in replacement unserviceable wooden / CI sunken box with new CRCA pressed steel terminal box of size 4 X 4' including taking down old complete with cemented and patch work complete all as specified and as directed.
Supply and fixing in replacement unserviceable wooden / CI sunken box with new CRCA pressed steel terminal box of size 10 X 8' including taking down old complete with cemented and patch work complete all as specified and as directed.
Supply and fixing in replacement Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (06 No's each) of size 8'' X 5'' complete all as specified and as directed.
Supply and fixing in replacement Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (12 No's each) of size 12'' X 10'' complete all as specified and as directed.
Supply and fixing in replacement Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (02 No's each) of size 5'' X 5'' complete all as specified and as directed.
Supply and fixing in replacement of plug top 15 Amps complete all as specified and as directed.
Supply and fixing in replacement of vertical distribution board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB's and should be IP-43 protected with copper bus bars, neutral links, earthing bar complete all as specified and as directed including taking down old unserviceable DB / MCB any type. Note: - (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 Volts with adjustable thermal settings. (ii) MCB's shall be measured and paid separately. (iii) TPN, DB and MCCB should be of same make.
Supply and fixing in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin, 5 amp 240 Volt along with switch piano 5 amp, 240 Volt complete all as specified and as directed.
Supply and fixing in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin, 5 amp 240 Volt along with switch piano 15 amp, 240 Volts complete all as specified and as directed.
Material and labour for repair / maintenance / servicing / overhauling to DG Set having caoacity 7.5 KVA to 140 KVA installed at pump house / site complete with entire cleaning checking of fuel pipe, lubricant oil pipe, rubber hose, panel wiring, fan belt, earthing strip, nut, bolts, exhaust pipe, battery pads, radiator hose, measuring instruments and tightening all nuts, bolts, banjo bolts, mild steel rubber hose clamps and to make the system leak proof and serviceable complete with including painting to rusted base frame channel with black paints including replacement of fuel filter elements all types as under and minor spare parts, banjo nuts, banjo washer, radiator top cap, battery terminal brass bolts type and changing engine oil including cleaning to oil sump and testing on full load after servicing complete all as specified and as directed. Note: - Spare parts shall be measured and paid separately.
Supply only fuel filter primery with 'O' ring
Supply only fuel filter secondary with 'O' ring
Supply only lubricant oil filter with 'O' ring
Supply only lubricant oil by pass filter with 'O' ring
Supply only air cleaner element
Supply only fan belt set for radiator, alternator and water pump etc.
Supply only battery lead copper heavy duty having length 1.5 metre each complete with one side banjo bolt and other side brass battery terminal bolt type set of 2 pieces.
Supply only rubber hose pipe for radiator, water pump, set of 5 pair complete with mild steel clamp of suitable size.
Repair / servicing of self starter 12 Volts DC complete with and including replacement burnt / unserviceable spare parts, clutch assembly, carbon brush, solenoid switch, plunger, armature and refixing for DG set 7.5 KVA to 140 KVA complete all as specified and as directed.
Dismantling / repair / overhauling of water pump assembly of DG set upto 140 KVA by replacing defective parts like pump, shaft, impeller CI, mechanical seal, water set gaskit, hub for pulley, set screw, bearing grooves nuts, spacers and spring washer and metling / machine work if any and refixing after repair complete all as specified and as directed.
Dismantling / repair / overhauling of charging alternator (dynamo) of DG set having capacity of 7.5 KVA to 140 KVA and replacement of unserviceable / defective parts like carbon brushes, bearing, leaver, pulley, spacer, commutator assembly, armature, washer etc. and refitting after repair complete all as specified and as directed.
Material and labour for replacement of engine oil servo super grade 20 / 40W of Indian oil including cleaning of oil sump thoroughly complete all as specified and as directed.
Dismantling / taking down radiator assembly for repair / servicing of DG set 7.5 KVA to 140 KVA and carry out complete internal cleaning, brazzing to tubing and rectification of leakage and refitting including replacement of minor spare parts like inlet / outlet rubber hose with mild steel clamps, pipe for thermostat to radiator washer, nut, bolts complete all as specified and as directed.
Disconnecting FIP pump of DG set of following capacity and carry out complete servicing / calliberation from authorised service centre and refitting after calliberation including replacement of injector nozzle, delivery valves, gaskit, fuel pump gear, flange assembly, plunger, copper washer, adaptor, set both etc. as required to make the FIP serviceable complete all as specified and as directed.
DG set capacity 7.5 KVA to 63 KVA
DG set capacity 70 KVA to 140 KVA
Supply and fixing in repair self starter 12 Volts 180 AH heavy duty suitable for DG set 7.5 KVA to 63 KVA, 70 KVA to 140 KVA complete all as specified and as directed.
Supply and fixing in replacement of battery charger heavy duty based on SMPS technology compatible with 12 Volt 80 AH to 180 AH, 10 Amp, complete with lead, Volt / Amp meter complete all as specified and as directed.
Supply and fixing in replacement set of high pressure of fuel pipe of engine complete nut, set volt, clamp and spring washer etc complete all as specified and as directed.
Supply and fixing in replacement of oil sump gaskit complete all as specified and as directed.
Supply and fixing in replacement of water temp switch suitable for DG set 7.5 KVA to 140 KVA complete all as specified and as directed.
Supply and fixing in replacement of AVR suitable for DG set 7.5 KVA to 140 KVA complete all as specified and directed.
Supply and fixing in replacement of diode and rectifier for alternator suitable for DG set 7.5 KVA to 140 KVA complete all as specified and as directed.
Supply and fixing in replacement of onload change over switch open execution type 4 pole 415 Volts 200 Amp in conforming to IS with front operated handle complete with fixing in existing LT Panel complete all as specified and as directed.
Supply and fixing in replacement of onload open execution change over switch 4 pole 415 Volts 100 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fixing on wall and angle iron bracket of size 40 x 40 x 6mm thick as per size requirement or complete all as specified and as directed.
Supply and fixing in replacement alternator flywheel ring for DG set capacity 7.5 to 63 KVA complete with disconnecting alternator from the engine and for replacement of flywheel complete all as specified and as directed.
Supply and fixing in replacement alternator flywheel ring for DG set capacity 70 to 140 KVA complete with disconnecting alternator from the engine and for replacement of flywheel complete all as specified and as directed.
Labour for dismantling to alternator from the engine of capacity 7.5 KVA to 140 KVA by opening nut and bolt and transport to workshop for repair / maint and rewinding with super enamelled heat resistant copper winding wire of existing size and no's of turn complete with insulating material i.e. varnishing, bamboo strips, cotton thread / tape, leather paper etc and drying the winding complete with checking, realignment, welding, grinding, earth work and polishing the alternator rotor shaft and refitting the alternator with engine after repair / rewinding and testing on full load complete all as specified and directed. Note: - Copper winding wire will be measured and paid separately.
Rewinding coil of alternator 7.5 KVA to 140 KVA with super enamelled heat resistant copper winding wire of existing size and no of turn conforming to ISI complete all as specified and as directed.
Material and labour for replacement of unserviceable ball bearing of alternator heavy duty conforming to ISI suitable for DG set alternator 63 KVA to 140 KVA complete all as specified and as directed.
Repair / maint / servicing to DG set control AMF panel of capacity 63 KVA to 140 KVA including replacement of internal panel wiring, automatic auto cut switch with relay, sensor unit multifunctional digital meter and make the panel serviceable and testing complete all as specified and as directed.
Material and labour for replacement of unserviceable automatic battery charging unit of AMF panel suitable for DG set 63 KVA to 140 KVA complete all as specified and as directed.
Material and labour for replacement of unserviceable speed controller with auto cut sensor unit for DG set capacity 63 KVA to 140 KVA complete as specified and as directed.
Dismantling all incoming / outgoing electric connection carefully of transformer, voltage stabilizer, LT panel, switch, change over etc and repair the cable, fixed properly with proper aluminium thimble / lugs including preparation of cable end for jointing complete all as specified and as directed. Note: - (i) Incoming / Outgoing cable connection for each cable will be measured as one each. (ii) Thimble shall be measured separately under respective items.
Supply and fixing in replacement of unserviceable batteries 12 Volt 180 AH heavy duty conforming to ISI complete with initial charging and battery lead set of 2 pieces having length of 1.5 metre each complete with one side banjo bolt and other side battery terminal bolt type complete all as specified and as directed.
Labour for disconnecting all incoming / outgoing electric connection carefully of fully automatic servo voltage stabilizer having capacity 20 to 300 KVA and transport to workshop for repair / servicing and including dismantling top cover of stabilizer and taking out the coil, drain out the transformer oil and refilling after dehydration of transformer oil, cleaning internally, including replacement of unserviceable body nut, bolts, washers, top gasket of cork sheet 6mm thick, replacement of internal circuit wiring if any suitable size of copper wire and painting with heat resistant smoke grey synthetic enamelled paint including preparation of old rusted surfaces and writing MES NO, SM MES No, capacity, Ser No, Location etc and reinstallation / connecting electric connection with replacement of proper size aluminium lugs and testing on full load at site complete all as specified and as directed. Note: - (a) Spare parts shall be measured and paid separately. (b) Rotor for replacement of spare parts are deemed to be included in above jobs.
Supply and fixing in replacement synchronous motor single phase 230 Volt suitable for servo voltage stabilizer having capacity 20 to 300 KVA complete all as specified and as directed.
Supply and fixing in replacement PCB suitable for servo voltage stabilizer having capacity 20 to 300 KVA complete all as specified and as directed.
Supply and fixing in replacement dimmer motor suitable for servo voltage stabilizer capacity 20 to 300 KVA complete all as specified and as directed.
Supply and fixing in replacement toggle On / Off switches for stabilizer capacity 20 to 300 KVA complete all as specified and as directed.
Supply and fixing in replacement Volt meter 0-500 Amp, 96mm square type, 3 phase 230 Volt, 50 Hz complete all as specified and as directed.
Supply and fixing in replacement Ampere meter 0-400 Amp, 96mm square type, 3 phase 230 Volt, 50 Hz with CT of suitable ratio complete all as specified and as directed.
Supply and fixing in replacement gun metal gate or glove valve 20 mm for drain out of oil complete all as specified and as directed.
Supply and fixing in replacement unserviceable brass / gun metal stud bush suitable for 20 to 300 KVA complete with connecting rod of suitable length and dia with necessary nut, bolt, washer, bushing packing to prevent the leakage from bushes and necessary connection complete all as specified and as directed.
Dehydration of Transformer oil and dielectric strength of oil achieved not to be less than 42 KV at 2.4 mm gap complete all as specified and as directed.
Supply and filling of new transformer oil for top up upto automatic servo voltage stabilizer including heating and dielectric strength not to be less than 60 KV complete all as specified and as directed.
Taking out main coil of voltage stabilizer 20 to 300 KVA for repair / rewinding with super enamelled copper winding wire of existing gauge including PVC insulated sheet sleeve, varnishing etc all as required and refixing to the stabilizer after testing all as required at site or as specified and as directed by Engineer-in-Charge.
Material and labour for repair / maint to desert coolers complete with and including cleaning, scrapping / rubbing old rusted surface, filling cavities and painting with two coats of high quality aluminium paint over a coat of red oxide primer externaly and black paint internally with synthetic enamelled paints complete with replacement of necessary nut, bolts, rubber pads for fan motors and writing MES No / unit name complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of desert cooler fan motor 90 watt, 1400 RPM, 230 Volt, 50 Hz single phase conforming to ISI complete with fan blade and capacitor of sutitable size complete all as specified and as directed.
Supply and fixing in replacement of desert cooler submersible pumping set single phase 230 Volt, 50 Hz of 0.25 to 1.0 HP conforming to ISI complete with lead complete all as specified and as directed.
Supply and fixing in replacement of PVC accessories of desert cooler i.e. PVC pipe 20 mm dia heavy duty 2 metre approximate, PVC distributor 4 way with nut, bolts, PVC elbow-03 No's, mild steel clamps etc complete all as specified and as directed.
Supply and fixing in replacement of desert cooler fan motor blade of existing size made out from mild steel having duty complete with key bolt complete all as specified and as directed.
Supply and fixing in replacement of desert cooler side opening cover made out from heavy duty mild steel sheet and matching with the existing desert cooler body size complete with Khas Khas pads set of three peices complete all as specified and as directed.
Supply and fixing in replacement of desert cooler unserviceable / leakage body made out from heavy duty mild steel sheet bend to shape company manufacturer, complete with internal PVC accessories i.e. PVC elbow-03 No's, PVC distributor 4 way-01 No, PVC distrbution pipe - 2 metre approximate, black painted internally, Aluminium painted externally complete with provision of necessary arrangement for fixing front cover and fan motor complete all as specified and as directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 1.5 Sqmm 3 core FRLS, 230 Volt, 50 Hz conforming to ISI complete all as specified and as directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 2.5 Sqmm 3 core FRLS, 230 volt, 50 Hz conforming to ISI complete all as specified and as directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 4.0 Sqmm 3 core FRLS, 230 volt, 50 Hz conforming to ISI complete all as specified and directed.
Supply and fixing in replacement of plug top 3 pin, 5 Amp, 230 Volt, 50 Hz complete all as specified and as directed.
Supply and fixing in replacement of PVC accessories of capacitor 2.5 MFD for desert cooler fan motor, 230 Volt 50 Hz complete all as specified and as directed.
Supply and fixing in replacement of unserviceable Khas Khas / Glass wool for desert cooler set of three pieces complete all as specified and as directed.
Repair / maint / servicing to refrigerator / deep freezer / water coolers / AC's of any capacity and model by replacing capillary tubing, gas chargings, rectification of leakage in capillary tubing / Chiller plant / water tanks, condensing coils, repair to wiring, flushing / cleaning, condensing / cooling coils / internal / external unit of split AC, greasing to blower motors, replacement of spare parts, fan belts and make refrigerator / deep freezer / water coolers / AC's in serviceable condition complete all as specified and as directed by Engineer-in-Charge. Note: - Spare / Gas charging shall be paid separately.
Charges for fixing in replacement of unserviceable sealed seamless welding compressor unit company manufacturer of any capacity for AC's complete with initial filling / charging of refrigerant gas to meet the requirement complete with vibration rubber pads four no's each nut, bolts etc and testing on full load all as specified and directed by Engineer-in-Charge. Note: - (i) Spare parts shall be measured and paid separately under respective items. (ii) Contractor shall be responsible for all replacement of failed compressor and shall be accompanied by certificate from the original compressor to the effect that said compressor has been repaired at their authorised service center. Further, a warranty of 12 months shall be provided on such replacement in writing.
Supply only sealed compressor unit seamless welding company manufacturer with filling of refrigerant gas conforming to ISI as under: -
For refrigerator 165 / 286 Litre capacity.
For refrigerator 290 / 320 Litre capacity.
For Deep Freezer 100 / 200 Litre capacity.
For Deep Freezer 300 / 400 Litre capacity.
For Water Cooler 40 / 80 Litre capacity.
For Water Cooler 60 / 120 Litre capacity.
Split / Window AC 1.5 Ton capacity.
Split / Window AC 2.0 Ton capacity.
Supply and fixing in replacement of unserviceable / burnt condensing fan motor 1/35 HP single phase 230 Volt 50 Hz complete with blade, fan belts for water cooler of capacity 40 / 80 Litre and 60 / 120 litre complete all as specified and as directed.
Supply only condensing fan motor 1/5 HP 1440 RPM single phase 230 Volt 50 Hz with double blade and shaft end with fan belts for windows AC / split AC conforming to ISI of capacity 1.5 / 2.0 ton complete with vibration parts etc complete all as specified and as directed.
Supply and charging refrigerant 134a/R-22 in sealed compressor unit of refrigerator / deep freezer / water coolers / AC's of any type and capacity after flushing the complete system with carbon tetrachloride (CTC) and vacuumise the complete system with vacuum pump and testing on full load including replacement of filter, strainer complete all as specified and as directed.
Supply and fixing in replacement of following spare parts for refrigerator / deep freezer / water coolers / AC's of any capacity: -
Starting relay
Overload protector
Thermostat switch
Defroz switch
Supply and fixing in replacement of following unserviceable spare parts of water cooler of any capacity: -
Starting capacitor 45 mfd
Running capacitor 60/120 mfd
Float valve PVC 15 mm dia with ball
Push cock chromium plated 15 mm with nipple 6'' long
Drain/Wash out flexible down pipe 40 mm dia
Water tank door gasket
Water drain tray of suitable size
Supply and fixing in replacement of unserviceable following spare parts of window / split AC unit of capacity 1.5 to 2.0 ton: -
Starting capacitor 36/40 mfd
Running capacitor 100/120 mfd
PCB of Split AC
Front Grill cover for window AC 1.5 Ton
Condensing fan motor double shaft
Supply and fixing in replacement of PVC flexible braided pipe of 20 mm dia for split AC water drain out complete all as specified and as directed.
Supply and fixing in replacement of outer split AC condensing unit complete for split AC 1.5 ton all as specified and directed.
Supply and fixing in replacement of inner unit of split AC complete with filters, blower motor etc for split AC 1.5 ton complete with all accessories all as specified and directed.
Supply and fixing in replacement of copper capillary tubing 5/8'' for AC connection / repair complete all as specified and as directed.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular 10 Sqmm complete all as specified and as directed.
Supply and fixing in replacement of condensing unit of Refrigerator / Deep Freezer / water cooler of any capacity complete with cutting and brazzing work complete all as specified and as directed.
Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 5 KVA complete all as specified and as directed.
Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 3 KVA complete all as specified and as directed.
Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 2 KVA complete all as specified and as directed.
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 1 KVA complete all as specified and as directed.
Notes: - (i) For Serial Item No 1 to 51 : The contractor has to complete the work assigned for the above items within 72 hours failing which recovery @ Rs. 25 per complaint per day shall be deducted. (ii) The MES Department shall not be responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the Electrician are deemed to be included in the item for repair i.e. Electrician / Helper, as all the items of CA are to be supply and fixed by the contractor. (iii) Proper record (date wise) of complaints received and rectified by the contractor shall be produced for verification at the time of payment of each RAR / Bill. (iv) All the complaint slip, register and connected documents will be provided by the contractor without any extra cost. (v) After any repair the site has to be cleaned and make the surface good.
M/S Shiv Enterprises
M/S SALARIA ASSOCIATES
M/s Sahib Construction and engineers
G R CONSTRUCTIONS
Harsh Electricals
Prakash Trading Corporation
M/s. Aggarwal Engineers
Bidder Name
Prakash Trading Corporation
G R CONSTRUCTIONS
Sarbat Construction Co
M/S Shiv Enterprises
Harsh Electricals
M/s. Aggarwal Engineers
M/s Sahib Construction and engineers
M/S SALARIA ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .