Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC | ₹3.4 Cr Quoted ₹3.2 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical As per Technical Evaluation Report |
Tender Value
₹2.8 Cr
EMD Value
₹2.8 L
Closing Date
10 Aug 2022, 3:00 pmClosed
Managing Director
Maharashtra State Agricultural Marketing Board, Plot No. R-7, Marketyard, Gultekadi, Pune 411 037
CW-4 a - Upgradation and Expansion of Existing Facilities at Ratnagiri Division - Vashi
2022_CMTAD_811648_1
MSAMB/ENGG/ADB/MAGNET/CW-4 (a)
Open Tender
Civil Works - Others
Item Rate
365 days
Vashi Navi Mumbai
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
₹2.8 L
Yes
MSAMB, Head office, Pune
13 Apr 2023
24 Jun 2022
10 Aug 2022
24 Jun 2022
10 Aug 2022
8 Jul 2022
24 Jun 2022 - 1 Jul 2022
4 Jul 2022
Vapour Heat Treatment Facility Center, Vashi, Navi Mumbai
Civil Work
Dismantling brick masonry in Mud and stacking the materials as directed with all leads, lifts etc. complete. (SSR 2019-20, Item no.46.09, Page no377, Additional specification :- As directed by engineer incharge)
Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. (SSR 2019-20, Item no.46.12, Page no377, Additional specification :- As directed by engineer incharge)
Removing rich mix cement concrete including stacking thespoilsasdirected with all leads, lifts etc, complete. (SSR 2019-20, Item no.46.13, Page no377, Additional specification :- As directed by engineer incharge)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc (SSR 2019-20, Item no.24.01, Page no.226, Additional specification Bd.E.1 Page No. 287)
Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. (SSR 2019-20, Item no.33.30, Page no.277, Additional specification As directed by Engineer in charge..)
Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering Incharge. Using Concrete Batching and Mixing Plant. (SSR 2019-20, Item no.7.01, Page no.87, Additional specification :- MORTH 408)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (SSR 2019-20, Item no.26.33, Page no.245, Additional specification Bd.F.17, Page No.306)
Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty, Sunproof, Waste Garbage Bins, Wheeled Bins, Easy to maintain & Use, envirnoment Friendly, Long Lasting Capacity : 240 Litre (Non SSR)
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer.: 50 liters 2. Disinfectant. : 30 Liters 3. Sodium Hypochlorite. : 30 KG 4. Fogging machine and Liquid for sanitization.: 1 Number 5. 3 Ply Face Mask of good quality. : 500 Numbers 6. Surgical / Latex Gloves of good quality.: 200 Pairs 7. Rubber Gloves of good quality.: 100 Pairs 8. Empty Spray Bottles 100 ml (Plastic).: 20 Numbers 9. Empty Spray Bottles 1000 ml (Plastic).: 5 Numbers 10. PPE kits. : 10 Numbers 10. Temperature Guns. : 3 Numbers 11. Face shield : 30 Numbers
Electromaechanical work
CCTV Works
Supply, install, testing & commissioning of 1080p Indoor Dome camera. Necessary Mounting arrangement shall be included. • 1080p dome camera with 1/2.7-inch CMOS, Total sensor pixels 1952 (H) x 1092 (V); 2.0 MP (approx.), • Camera shall have functionality to change its focal length without opening the camera & shall be able to choose the coverage area remotely. • The camera shall have an Area-based encoding which reduces bandwidth. • The cameras shall be powered from the Ethernet Switch using Power over Ethernet (POE). External Power supply shall not be used. • The camera shall support H.264 standard. • A wide range of configuration options shall be available for alarms signaling the camera. • The camera shall compliance to the ONVIF Profile ONVIF Profile Q and ONVIF Profile G specifications so that the interoperability between network video products is possible regardless of manufacturer. • Contractor shall submit the calculation the lens and focal length requirements to meet the coverage required during the execution.
Supply, install, testing & commissioning of 1080p Bullet camera with 1/2.9-inch CMOS, Total sensor pixels 1936 (H) x 1097 (V); 2.12MP (approx.), Built-in IR illuminator with 30 m (98 ft) viewing distance, 1080P. Necessary Mounting arrangement shall be included.
Supply, install, testing & commissioning 32 ch NVR with storage: Network video recorder (NVR) for all-in-one recording, viewing, and management solution for of IP cameras and recording of their video streams. Network storage unit shall be connected to the domain Ethernet switch using ethernet interface.The storage unit shall be sized to accommodate continuous video storage for 15 days as per the requirements to be considered. The storage unit shall be provided with data protection feature against hard disk failure. The system shall have built in automatic defragmentation routines to avoid data getting fragmented. The system shall record H.264 Compressed video from Cameras. The storage unit shall have redundant hot swappable power supply and fan units. The storage unit shall support tagging of video. The network storage unit shall be fully manageable using the Ethernet interface
Supply, install, testing & commissioning 32" monitor with HDMI Cable
Supply, install, testing & commissioning 8 Ports POE Switch with 2 SFP ports for cameras
Supply, install, testing & commissioning SFP module
Supply, install, testing & commissioning Loaded LIU
Supply, install, testing & commissioning of OFC Patch cord
Supply, install, testing & commissioning Industrial Media Converter
Supply, install, testing & commissioning 9U network rack
Supply, install, testing & commissioning 6U network rack
Supply, install, testing & commissioning of Cat 6 Cable
Supply, install, testing & commissioning of PVC conduit of size 25 mm
Supply, install, testing & commissioning of FO Cable,6 Core SM,Armoured
Refrigeration Planr and Machinery works for Cold Storage Unit
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-100 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-60 mm thick PIR panels,for beam bottom areas Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for fixing ceiling structure from the slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered.
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-100 mm thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for fixing ceiling structure from the slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered.
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 75 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.
Supply & Fixing of 6~9 mm thick EPDM / Nitrile rubber on RCC slab / brick walls with suitable CPRX compound adhesive over which the insulated panels shall be fixed tightly with Nylon / FRP / Steel reinforced Nylon bolts.The bolt heads on the panels shall be covered with hat runners filled with PUF insulation as per standard practice.
Supply & fixing of of Al foil min. 50 micron on RCC slab / brick walls with suitable CPRX compound adhesive / bitumen
Ancillary Materials and Services - Flashings for Internal and external wall-ceiling joints and wall-wall joints as applicable or as may be required for doors or other openings. The layout showing the chamber dimensions and height is enclosed for ready reference. The flashings should be atleast 50mm x 50 mm or larger sizes with adequate overlap over any given panel-panel joint (Precoated G.S. Sheet, minimum 0.5 mm thick)
Ancillary Materials and Services - Silicon / Polyeurathene sealant for sealing the gaps between panels and the external / internal face of the insulation panels and any other location as may be deemed suitable for proper insulation panel erection system as applicable.
Ancillary Materials and Services - PUF/PIR chemical, adhesives,/ tapes / plastic caps etc reqd for onsite application, as may be necessary for a complete and foolproof insulation job.
Ancillary Materials and Services -SITC of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 10 deg C. (Fermond Soupape 2220 -Valve /Equivalent)- 1 no for each cold storage chamber.
Ancillary Materials and Services - Making & finishing of cut outs for doors, pipes, cables, pressure ports etc as per requirement at site. Finishing would include filling with PUF/PIR & PUF/PIR foam of required density and covering with pre - coated G.I.sheet from both side of the panels to give aesthetically neat joint acceptable to Consultants / Owners. This should also include any additional Silicon sealent or any other material as required.
Staging cold room 1 & 2 Manual Sliding type 1500 mm x 2100 mm ht x 100 mm thick PIR , manual type Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. Ht mentioned is tentative The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .
SITC of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature
For Cold room 1,2 Suitable for Clear opening Size: 1500mm X 2100mm ht
AIR COOLED CONDENSING UNITS For cold room 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver, Base frame for mounting, H.P. / L.P. cut outs and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For cold room 1,2 Capacity: 25 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLING UNITS - Air Cooling Units for cold room 1,2 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 25 Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 6 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 28500 External sp. Wg, mm: 6 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 10 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC+weatherproof coating/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support. This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
Controls and Instruments (a) Thermostatic expansion valves for each ACUs (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area.
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant.
Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint .
Miscellaneous Items a) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing.
Charges for Installation, Testing and Commissioning Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
VENTILATION SYSTEM - Air Curtains for COLD STORE Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: approx. :1500 mm x 2100 mm ht
Electrical Works
Supply & Installation of 32 x 6 mm Galvanized Iron earthing strip & Conductor shall be of High Conductivity. All Necessary Accessories required for installation of Earthing Strips such as Porcelain Insulators, Clamps, Saddles, Hardware, etc will be included in the rate. The Earthing strips connections shall be used as per the provided earthing schedule.
Same as above with Earthing strip of 25 x 3 mm Copper.
Supply, Installation, Testing & Commissioning of 3.5 C x 50 sq.mm, 1.1 KV grade, Stranded aluminium conductor, XLPE insulated, armoured, PVC outer sheathed cables conforming to IS:7098 ( Part-I ). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Cable Tray. Termination of cables using double compression gland, crimping type lugs, etc. Each termination shall include supply of all necessary components, accessories, including double compression cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.
Same as above but with 4.0 C x 6 sq. mm. Copper multi stranded.
Same as above but with 4.0 C x 4 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 6 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Same as above but with 2.0 C x 2.5 sq. mm. Copper multi stranded.
Supply & Installation of 4.0 C x 6 sq. mm 1.1 KV grade, Multi Stranded Copper conductor, PVC insulated, PVC outer sheathed cables conforming to IS:694 (1990). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Conduit/Cable Tray. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Termination of 4.0 C x 6 sq. mm, LT copper flexible cables using PVC cable gland of IP65, crimping type Copper lugs, etc. Each termination shall include supply of all necessary components, accessories, including PVC cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Supply & Installation of 200 x 75 mm, Perforated type cable trays made out of 16 G CRCA sheet & Hot Dipped galvanized, with support at every 1.5 mt. interval using M.S. angle of size 40x40x5 mm Or Using Suspension GI rods. M.S. Support shall be painted with two coats of red oxide primer & two coats of silver paint. All necessary accessories required for installation of cable trays such as Cable Tray Supports, Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.
Supply & Installation of 200 x 20 mm, cable tray cover made out of 18 G CRCA sheet & Hot Dipped galvanized, with all necessary accessories required for installation of cable tray covers such as Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.
Supply, Installation, Testing & Commissioning of Primary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.
Supply, Installation, Testing & Commissioning of Secondary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.
Same as above but control shall be two way.
Same as above but on lighting switch board ( Half Pt.).
Supply, Installation, Testing & Commissioning of 6/16 A socket point with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit (wiring & conduit will be measured in mains ).
Supply & Installation of 25mm medium duty PVC conduit with standard accessories and to be used for concealed / surface mounted on the ceiling/wall.
Supply & Installation of 25 mm wire reinforced type flexible PVC conduit with PVC glands on both sides to be used for flexible copper wires / cables.
Supply, Installation, Testing & Commissioning of mains / sub-main wiring using FRLS type wires of 2x2.5 sq.mm. + 1x1.5 sq.mm. PVC insulated, multistranded copper conductor through existing PVC conduit. ( Measurement of conduit & wires shall be separate ).
Same as above but with 2x4.0 sq.mm. + 1x2.5 sq.mm.
Same as above but with 4.0 sq.mm
Supply, Installation, Testing & Commissioning of 4 way VTPN MCB DB with double door, comprising of following: Incoming : 63 A 4 pole MCB 10 KA 1 No. Outgoing : 32 A 3 pole MCB. 10 KA. 3 Nos. 16 A 1 pole MCB. 10 KA. 3 Nos.
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of following: Incoming : 25 A DP RCBO 30 mA Hpi type. 1 No. Outgoing : 10 A 1 pole 10 KA MCB. 4 Nos.
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 2way connectors & earthing terminal inside.
Supply, Installation, Testing & Commissioning of 39/40 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
Supply, Installation, Testing & Commissioning of 20 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
Supply, Installation, Testing & Commissioning of 375/380 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 1470 (±10%)
Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 30 mins power backup. 4 points Annunciator - 1 No Stay-put type push buttons. - 2 Nos. 2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 50 Mtrs Medium duty PVC conduit of 25 mm size with standard accessories. - 30 Mtrs
Conveyors
SITC of Motorised conveyor for movmeent of crates with product or boxes from VHT machine gate to Pre-cooling. Movement to be possible in both directions. Further, the conveyor should modular and be easily movable, meaning it should have heavy duty lockable wheels whichi will allow the conveyor to be segregated and shifted as required. There is a 450 to 600 mm lift (or drop) from the VHT to the passage. Motorised movement in both directions should be possible for crates or boxes such that the boxes do not slide when going downwards or upwards. Rate to be given in running meters so that the actual size can be adjusted as per site conditions. Maximum weight of crate or box should be considered as 50 kgs . Material of Constuction : MS Powder coated for main structure and SS 304 for wheels. Electrical control panel with starter for all other motors with respective H.P. with on/off switch, emergency stop button, Push button & relay, RYB indicators & Emergency stop button etc with related power and control cabling shall be included.
SITC of Motorised conveyor for Extenssion to Fruit Belt up to Dock Leveller for Crates / Boxes The conveyor to be suitable for horizontal movement of crates / boxes Movement to be possible in both directions. Further, the conveyor should modular and be easily movable, meaning it should have heavy duty lockable wheels whichi will allow the conveyor to be segregated and shifted as required. Rate to be given in running meters so that the actual size can be adjusted as per site conditions. Maximum weight of crate or box should be considered as 50 kgs. Material of Constuction : MS Powder coated for main structure and SS 304 for wheels. Electrical control panel with starter for all other motors with respective H.P. with on/off switch, emergency stop button, Push button & relay, RYB indicators & Emergency stop button etc with related power and control cabling shall be included.
Doors
For Paaasage Area Insulated Doors -Swing type with double shutter 2200 mm x 2000 mm ht x min. 49 mm thick PIR Providing & fixing of Insulated doors (suitable for fitting on panel /brick wall structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated double leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 42 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window on each door leaf shall be provided. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing and door shall be able to pass light test. Light test is carried out by APEDA / export authority officials and the same shall have to be passed by the door, from all sides of the door including the bottom and top. Auto door closure system for both the leafs shall be provided. Alternatively flip flaf doors with perfect hearmatically sealing also can be considered. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
SITC of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature For Passage Area Suitable for Clear opening Size: 2200 mm x 2000 mm ht
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance. Acceptable makes: Nilkamal/Supreme / Eqvt
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Josts / Eqvt. Model No. : to be mentioned Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,
Flexible Arm Illuminated Magnifier Lens: Specially designed, distortion controlled high quality lens correctly sized for both eyed (bi-ocular) vision. Lens Size: 170mm x105 mm, with power 3.2D. Provides about 4 times area magnification. Working clearance below lens mount is 250 mm, and field seen can be up to 250 mm. Illumination: 2 x7 watt standard CFLs with independent switches that enable shadow free or directional bright illumination in the work area. Stand: Highly optimized design , spring balance stand with feather-touch movement to place lens in the correct position and orientation. Lens center can reach out 900 mm in front of mount axis with up to 360 degrees swivel Model: Lensel Flexible Arm Illuminated Magnifier Deluxe Model with Movable Base (L104DX+L104B) / Eqvt
Overhauling of Machinery
Overhauling of Machineries for 1 precooling chamber, 2 cold rooms ,grading sorting line etc as per the scope given below. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting. Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required.
• Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found.
Scope of Work for Insulated Doors, Strip and Air curtains: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. Scope of work for Electrical System: If anything mentioned below found not normal, same shall be rectified • Check for loose connection of all terminals in the panels. • Clean gently the dust by air pressure in side the panels. • Check the mounting of CTs for its position, ensure that does not make contact with body. • Check for loose connections for all power / neutral cable connections. • Check for all the fuses. • Check for loose connections of all power cables & control cables of panel. • Check for loose connections of cables of meters / contractors. • Check the outgoing & incoming phase, neutral connection of circuit breaker. • Check the thermal trip of circuit breaker. • Check mountings of circuit breaker & tightness of power cables. • Check Capacitor conditon in APFC Panel. Replace if required. • Transformer oil conditon check. Filtraction or replacment of oil as per condtion of oil • DG set battery check. Replace/charge as required. • DG set general servicing as per manufacturers recommendation. replacment of filters etc as required.
Scope of Work for Conveyors: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt, pulley Overal the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc needs replaceent, then the cost of the motor would be borne by the end-user / MSAMB / user but the installation and commissioining of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.
Vegetable Processing Facility (VPF), 1st Floor, IFC Premises, Plot no. 3, Sector 19F,Vashi, Navi Mumbai
Civil work
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.
Removinglimeorleancementconcreteincludingstackingthespoilsas directed with all leads, lifts etc, complete.
Removingrichmixcementconcreteincludingstackingthespoilsasdirected with all leads, lifts etc, complete
Removing brickbat coba including stacking the spoils as directed with all leads, lifts etc, complete.
Dismentaling Puf pannel with all required works icluding stacking as directed by Consultant and engineer.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) by Mechanical Means.
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) by Mechanical Means..
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m) by Mechanical Means.
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5 m) by Mechanical Means.
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 m). By Mechanical Means (SSR2019-20, Item no.21.20, Page no.199, Additional specification Bd.A.6 Page No.260)
Providing and laying Cast in situ/ Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural sand/ Crushed sand V.S.I. Grade finely washed etc.)
Providing soling using 80mm size trap metal in 15 cm. layer including filling voids with crushed sand /grit ramming, watering complete.
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2021-22, Item no.25.13, Page no.230, Additional specification Bd.C.12 Page No. 275)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as perdetailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2021-22, Item no.25.33, Page no.233, Additional specification Bd.F.3 Page No.298 and B.7, PageNo.38)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2021-22, Item no.25.52, Page no.235, Additional specification Bd.F.6 Page No. 300 and B.7, Page No.38)
ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-25oftrap/granite/quartzite/gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering,formwork,coverblocks,laying/pumping,compactingandrougheningthemifspecialfinishistobeprovidedandcuringcomplete.(Excludingreinforcementandstructuralsteel).withfullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(NaturalSand/Crushed sand VSI Grade finely washed etc)
Providing and fixing in position TMT FE -500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing and laying in situ cement concrete M-30 with tremix treatment for 200 milimetre thickness for Concrete Road including laying plastic sheet of 125 micron with groove cutting of 4 milimetre wide and 20 milimetre deep, with necessary refilling with bitumen (excluding reinforcement) with course and fine agreegates (Natural sand/ VSI sand finely washed crushed sand) etc. complete.
Filling in plinth and floors with approved excavated materials in 15 cm to 20 cm layers including watering & compaction complete.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. (SSR2019-20, Item no.21.37, Page no.195, Additional specification Bd.A.11 Page No. 263)
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (SSR 2021-22, Item no.23.01, Page no.223, Additional specification Bd.C.12 Page No. 275)
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete.NOTE: For Item No. 15 to 18 prior approval of Superintending Engineer will be necessary CSR P.No. 283 I.No. 35.26 R.A. 24
Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or velley to galvanised iron sheet roofing including all fastening and bolt galvanised iron screws and bolts and lead and bitumen washers complete. ( Weight of 6.8 Kg/Sq.m.)
ProvidingsecondclassBurntBrickmasonrywithconventional/I.S.typebricksincementmortar1:6insuperstructureincludingstrikingjoints, raking out joints, watering and scaffolding etc. Complete
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (SSR 2021-22, Item no.32.03, Page no.268, Additional specification Bd.L.2 Page No.367)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (SSR 2021-22, Item no.32.11, Page no.269, Additional specification Bd.L.7 Page No.369)
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (SSR 2021-22, Item no.35.21, Page no.297, Additional specification As directed by Engineer in charge. )
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. (SSR 2021-22, Item no.50.79, Page no.448, Additional specification :As directed by Engineer in charge.)
Providingandfixinginpositionpowdercoatedaluminiumlouveredwindows/ventilatorofvarioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincludingaluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,ofapproved quality etc. complete
Providing stain less steel grating of 100 mm width of steel square bars 0f 10 mm x10 mm @ 3 cm c/c over existing gutter in floor including supporting stain less steel hold fast angle etc.
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) (SSR 2021-22, Item no.39.25, Page no.318, Additional specification BD-T-55 Page No.510 )
Electromechanical work
CCTV Works
Supply, install, testing & commissioning of 1080p Indoor Dome camera. Necessary Mounting arrangement shall be included. • 1080p dome camera with 1/2.7-inch CMOS, Total sensor pixels 1952 (H) x 1092 (V); 2.0 MP (approx.), • Camera shall have functionality to change its focal length without opening the camera & shall be able to choose the coverage area remotely. • The camera shall have an Area-based encoding which reduces bandwidth. • The cameras shall be powered from the Ethernet Switch using Power over Ethernet (POE). External Power supply shall not be used. • The camera shall support H.264 standard. • A wide range of configuration options shall be available for alarms signaling the camera. • The camera shall compliance to the ONVIF Profile ONVIF Profile Q and ONVIF Profile G specifications so that the interoperability between network video products is possible regardless of manufacturer. • Contractor shall submit the calculation the lens and focal length requirements to meet the coverage required during the execution.
Supply, install, testing & commissioning of 1080p Bullet camera with 1/2.9-inch CMOS, Total sensor pixels 1936 (H) x 1097 (V); 2.12MP (approx.), Built-in IR illuminator with 30 m (98 ft) viewing distance, 1080P. Necessary Mounting arrangement shall be included.
Supply, install, testing & commissioning 32 ch NVR with storage: Network video recorder (NVR) for all-in-one recording, viewing, and management solution for of IP cameras and recording of their video streams. Network storage uUnit shall be connected to the domain Ethernet switch using ethernet interface.The storage uUnit shall be sized to accommodate continuous video storage for 15 days as per the requirements to be considered. The storage uUnit shall be provided with data protection feature against hard disk failure. The system shall have built in automatic defragmentation routines to avoid data getting fragmented. The system shall record H.264 Compressed video from Cameras. The storage uUnit shall have redundant hot swappable power supply and fan uUnits. The storage uUnit shall support tagging of video. The network storage uUnit shall be fully manageable using the Ethernet interface
Supply, install, testing & commissioning 32" moUnitor with HDMI Cable
Supply, install, testing & commissioning 8 Ports POE Switch with 2 SFP ports for cameras
Supply, install, testing & commissioning SFP module
Supply, install, testing & commissioning Loaded LIU
Supply, install, testing & commissioning of OFC Patch cord
Supply, install, testing & commissioning Industrial Media Converter
Supply, install, testing & commissioning 9U network rack
Supply, install, testing & commissioning 6U network rack
Supply, install, testing & commissioning of Cat 6 Cable
Supply, install, testing & commissioning of PVC conduit of size 25 mm
Supply, install, testing & commissioning of FO Cable,6 Core SM,Armoured
SITC of Electric Traction Goods Lift with • Rated capacity: - 3000Kg Goods,Floors :- G+1 floor (2Stops/2 Landings),Travel :- 3 to 4.2 mtrs, Location of Lift Machine: - MRL, Rated speed :- 1.0mps VS, Doors type :- COPO/TOPO Doors with frame having clear opening of 1500mm wide x 3000mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/frames. Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor Clear Car size of 1700mm wide x 1500mm deep x 3000mm High LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing, CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV moUnitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength
Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. Lift shaft available having clear size of 2000mm wide x 2000mm deep, 1000mm Pit depth, 1000mm Overhead. For Lift having 1500mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door [Four panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows indicators,extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. Notes 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2) Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.
Overhauling of Machinery ( Item Nos from 3.01 to Item Nos 3.04 )
Overhauling of Machineries for 1 precooling chamber, 2 cold rooms ,conveyors etc as per the scope given below. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found.
Scope of Work for Insulated Doors, Strip and Air curtains: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/limit switch /full uUnit,as the case may be to ensure proper operation Scope of work for Electrical System: If anything mentioned below found not normal, same shall be rectified • Check for loose connection of all terminals in the panels. • Clean gently the dust by air pressure in side the panels. • Check the mounting of CTs for its position, ensure that does not make contact with body. • Check for loose connections for all power / neutral cable connections. • Check for all the fuses. • Check for loose connections of all power cables & control cables of panel. • Check for loose connections of cables of meters / contractors. • Check the outgoing & incoming phase, neutral connection of circuit breaker. • Check the thermal trip of circuit breaker. • Check mountings of circuit breaker & tightness of power cables. .
Scope of Work for Conveyors: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt, pulley Overal the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc needs replaceent, then the cost of the motor would be borne by the end-user / MSAMB / user but the installation and commissioining of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.
DOCK DOOR & SEAL Dock door shall be vertically moving with motorized movement. The shutter shall have PUF core with aluminum external / internal facing with white paint (RAL9003E/Eqvt). The vertical moving track shall be U shaped made of 2.5 mm G.S. Sheets. Full perimeters doors seal with PUF verticals, Vinyl lintel seal & rubber seal of bottom shall be provided. acceptable makes: Gandhi Automation/ Metaflex/Infraca (a) Dock door motorised type (b) Dock door motorized complete with control control button, manual lock release & cabling. DOCK DOOR: Type:motorised type Door opening Size : 2400 width x 2700 mm height Insulation : 40 mm PUF Door Movement : upwards, then curving into the ceiling Facing : External : Aluminium painted white Internal : Paint for higher impactability Operator : Normal Viewing Window: 1 no DOCK Seal : CUSHION type suitable for heavy duty operations for door opening size as above. Dock seal to have adjustable top vertical member so as to adjust for container height variations. Flexible polyurethane foam, covered with PVC / polyester fabric, supporting the vehicle pressures and perfectly sealing the three sides.
DOCK LEVELER Designed for Hydraulic operation as per General technical specification ,Size : 2000mm width and 2500mm deep, lift height min 300 mm from centre level, upwards & downwards., main cylinders-2 nos, All controls, control panels, controllers, power and control cabling etc as required for full operation to be included
SITC of Sandwich panels for walls, ceiling PIR 60 mm thick, 40 kg/m3 density with 0.5 mm / 0.5 mm thick PCGS sheet Rate should also include supplly,instalation of flashings for wall- wall, waal-ceiling joints & any other areas as applicable- min 0.5 mm thick, silicon sealant, PUF chemical, adhesives, tapes, plastic caps for cam locks etc as required for onsite application, , as may be necessary for a complete and foolproof insulation job
Electrical Works
Supply & Installation of 4.0 C x 6 sq. mm 1.1 KV grade, Multi Stranded Copper conductor, PVC insulated, PVC outer sheathed cables conforming to IS:694 (1990). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Conduit/Cable Tray. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals. Termination to be included in the cost.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 annd having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 32 Amp. FP MCB 10 KA with 32 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 and having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 16 Amp. FP MCB 10 KA with 16 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.
Solid waste disposal :- Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty, Sunproof, Waste Garbage Bins, Wheeled Bins, Easy to maintain & Use, envirnoment Friendly, Long Lasting Capacity : 240 Litre (Non SSR)
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer. 2. Disinfectant. 3. Sodium Hypochlorite. 4. Fogging machine and Liquid for sanitization. 5. 3 Ply Face Mask of good quality. 6. Surgical / Latex Gloves of good quality. 7. Rubber Gloves of good quality. 8. Empty Spray Bottles (Plastic). 9. PPE kits. 10. Temperature Guns. 11. Face shield
Irradiation Facility Centre (IFC), Plot No. 3, Sector – 19F, Vashi, Navi Mumbai
Dismantling brickmasonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc . complete. (Item no.46.09, Page no.377, Additional specification : As directed by engineer incharge.)
Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. (Item no.46.13, Page no.377, Additional specification : As directed by engineer incharge.)
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete (Item no.46.19, Page no.378, Additional specification : As directed by engineer incharge.)
Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. ( Item no.46.29, Page no.379, Additional specification : As directed by engineer incharge.)
Removing wooden or A.C. partition including frame work and stacking the materials as with all leads, lifts etc. complete. ( Page no.378, Additional specification : As directed by engineer incharge.)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means (I.No.21.02, P.No.197, Additional Specification Bd.A.1 Page No. 259)
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete. (.I.No.21.36, P.No.201, Additional Specification Bd.A.10 Page No. 262)
Filling in plinth and floors with contractors approved material / murum / stone dust in 15cm. to 20cm. layers including watering and compaction complete. (.I.No.21.37, P.No.201, Additional Specification Bd.A.10 Page No. 262)
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. (.I.No.21.38, P.No.201, Additional Specification As directed by Engineer in charge.)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (.I.No.24.01, P.No.225. Additional Specification Bd.E.2 Page No. 288 and B.7 Page No 38)
Providing and casting in situ cement concrete of M25 grade of trap / granite /quartzite /gneiss metal for R.C.C. beams and lintels as per detailed design and drawings or as directed,including steel centering, plywood/steel formwork steel props, compaction, finishing uneven and honeycombed surface with C.M.1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. Including use of plastisizer wherever necessary as directed by Engineer-In-charge (Excluding reinforcement, including cover block). The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (.I.No.25.52, P.No.235. Additional Specification Bd.F.5 Page No. 300 and B-7,Page No 38.)
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, form work, cover blocks, laying / pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (.I.No.26.07, P.No.239. Additional Specification Bd.F.9 Page No. 303 and B.7, Page No.38)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)(Item no.26.19, Page no.240, Additional specification Bd.F.11 Page No.304 and B.7, Page No. 38)
Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (.I.No.26.33, P.No.245. Additional Specification Bd.F.17, Page No. 306)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. (.Item no.27.01, Page no.254, Additional specification Bd.G. 1 Page No.313)
Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete (.I.No.27.05, P.No.254. Additional Specification Bd.G.5 Page No. 315)
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (.Item no.32.03, Page no.268, Additional specification Bd.L.2 Page No.367)
Providing and applying plaster / wall punning with plaster of paris (with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc complete. (.Item no.32.30, Page no.271, Additional specification As directed by Engineer in charge.)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rought or receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (.I.No.32.11, P.No.269. Additional Specification Bd.L.7 Page No. 369)
Washing and cleaning wall surfaces with soap, soda and water etc. complete.
Scrapping the old plastered internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding etc. complete as directed.
Providing and applying priming coat concrete/ masonary/Asbestos cement plaster surfaces including scaffolding preparing the surfaces by throughly cleaning oil, grease, dirt and other foreign matter and sand papering as required. (.I.No.35.21, P.No.288. Additional Specification As directed by Engineer in charge.)
Providing and applying interior wall finish luster of Asian / Berger / Nerolac / Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean. Applying Asian / Berger / Nerolac / Duuex Paints or equivalent wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. Applying Asian / Berger / Nerolac / Dulex Paints or equivalent Acrylic wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applying Asian / Berger / Nerolac / Dulux Paints or equivalent wall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, Applying Asian / Berger / Nerolac / Dulux Paints or equivalent interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat of Asian / Berger /Nerolac / Dulux Paints or equivalent interior wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% (.Item no.36.20, Page no.292, Additional specification As directed by engineer incharge )
Providing and applying external raincoat painting with crack filling acrylic polymer based chemical compound coating to the external surface of walls to prevent water seepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint, removing loose particles of sand on the surface opening and cleaning the cracks developed in the external plaster, removing loose particles by chiseling, filling cracks by chemicals compound of approved make with proper penetration etc. Coating of Raincoat with the help of brush and as per instructions and specification given by manufacturer and with instruction from Engineer in-charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs. 500/- and necessary testing etc. complete. (.Item no.35.29, Page no.289, Additional specification As directed by engineer incharge )
Providing preconstructional anti termite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. (I.No.21.24. P.No.199. Additional Specification As directed by Engineer in charge)
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. (.I.No.40.01, P.No.338. Additional Specification Bd.U.1 Page No. 537)
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.(Item no.31.05, Page no.264, Additional specification As directed by engineer incharge)
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. (S.S.R.2018-19 Item No 32.26 P.No.270, additional spec no. As directed by Engineer in Charge)
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. (.Item no.33.67, Page no.283, Additional specification : Bd. M-12 page No.385 )
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. (.I.No.39.68, P.No.331. Additional Specification As directed by Engineer incharge.)
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/ moulding the sharp edges wherever necessary, curing, etc. complete. (.Item no.33.68, Page no.283, Additional specification As directed by engineer incharge )
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 kg/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ? and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of size 100 mm x 25MM x 2mm using 32 mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares should be fixed with 19 x 6 mm size steel screws including fixture fasting. Complete as per direction of engineer in charge (.I.No.39.47, P.No.326. Additional Specification As directed by Engineer incharge.)
Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. (.I.No.42.20, P.No.353. Additional Specification As directed by Engineer incharge.)
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5 mm thick at top, 40 mm diameter and 1.5mm thick vertical supports spaced at 1.5 M center to center and 8 mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding , finishing, buffing to stainless steel pipe etc. complete. (.I.No.40.07, P.No.339. Additional Specification As directed by Engineer incharge.)
Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.(Item no.33.66, Page no.283, Additional specification : BDM 12 , page no.385)
Medium Height Partition @ 1800/1200HT TILE BASED PARTITION SYSTEM:- Tile based Aluminum partition system of 1800/1200 mm ht. made of 60mm thk aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/ exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look.Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thk., and prelaminated partical board. (Item no.51.25, Page no.466, Additional specification : As directed by engineer incharge.)
Plumbing work
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565 (.(I.No.41.74, P.No.349. Additional Specification Bd.V.30 Page No. 565.)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.82, P.No.361. Additional Specification Bd.V.30 Page No. 565.)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.79, P.No.361. Additional Specification As directed by engineer incharge. )
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete.(.Item no.42.80, Page no.361, Additional specification : BD.V 5 page 551 and as directed by Engineer in charge)
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (.Item no.42.57, Page no.359, Additional specification : BD.V 5 page 551 and as directed by Engineer in charge)
Providing and fixing on walls/ ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (.Item no.42.59, Page no.359, Additional specification : BD.V 5 page 551 and as directed by Engineer in charge)
Providing and fixing on Walls / Ceiling / Floor 15 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (I.No.42.55, P.No.358. Additional Specification As directed by engineer incharge. )
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.37, P.No.355. Additional Specification As directed by engineer incharge. )
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.36, P.No.355. Additional Specification As directed by engineer incharge. )
Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty, Sunproof, Waste Garbage Bins, Wheeled Bins, Easy to maintain & Use, envirnoment Friendly, Long Lasting Capacity : 240 Litre (Non SSR)
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer.: 50 liters 2. Disinfectant. : 30 Liters 3. Sodium Hypochlorite. : 30 KG 4. Fogging machine and Liquid for sanitization.: 1 Number 5. 3 Ply Face Mask of good quality. : 500 Numbers 6. Surgical / Latex Gloves of good quality.: 200 Pairs 7. Rubber Gloves of good quality.: 100 Pairs 8. Empty Spray Bottles 100 ml (Plastic).: 20 Numbers 9. Empty Spray Bottles 1000 ml (Plastic).: 5 Numbers 10. PPE kits. : 10 Numbers 10. Temperature Guns. : 3 Numbers 11. Face shield : 30 Numbers
Elctromech Work
For Paaasage Area Insulated Doors -Swing type with double shutter 2200 mm x 2400 mm ht x min. 44 mm thick PIR Providing & fixing of Insulated doors (suitable for fitting on panel /brick wall structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually opeRated double leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 42 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window on each door leaf shall be provided. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing and door shall be able to pass light test. Light test is carried out by APEDA / export authority officials and the same shall have to be passed by the door, from all sides of the door including the bottom and top. Auto door closure system for both the leafs shall be provided. Alternatively flip flaf doors with perfect hearmatically sealing also can be considered. The Rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
SITC of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature For Passage Area Suitable for Clear opening Size: 2200 mm x 2400 mm ht
Hydraulically OpeRated Hand Pallet Truck Type : Hydraulically opeRated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Josts / Eqvt. Model No. : to be mentioned Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,
Dismantling and stacking existing dock levellers keeping protected the peripheral infrastructure against damage as directed by engineer incharge and required civil and electrical work
DOCK LEVELER Designed for Hydraulic operation in accordance of EN:1398 in steel construction as per General technical specification ,Acceptable makes: Gandhi Automation/ Metaflex/Infraca Size : 2000mm width and 2500mm deep, lift height min 300 mm from centre level, upwards & downwards., main cylinders-2 nos, All controls, control panels, controllers, power and control cabling,, pair of bumpers etc as required for full operation to be included
Overhauling of Machinery
Overhauling of Machineries for 1 precooling chamber, 2 cold rooms ,transformer, DG sets, split Acs, dock,conveyors etc as per the scope given below. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace minor parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. •ACU fan & motor- routine & preventive maintenance • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. • Pre-cooling AHU water pump not working properly. fault to be idetified and pump to be brought in working condition. • Condenser inlet air pre-cooling system - to be cleaned, pump repaired (if required), pipig cleaned and other routine and preventive maintenance.
Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found. Scope of Work for Insulated Doors, Strip and Air curtains, Dock shelters: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/full unit, if required. • Dock shelter- check for any damage, leackage etc. appropriate action to be taken to so as to make them fully funcational. • Dock leveller: cleaning, lubricating the parts with proper lubracants, All necessary components are adjusted properly to make sure equipment works smoothly and consistently.check fluid level in hydraulic cylinders, top-up/ replace the fluid as may be necessary.
Scope of work for Electrical System: • Transformer: oil condition checking, leakages to be attended, testing of oil for various parameters as per standard practice, Filtration or replacement / top up of oil as per condition of oil, Insulation resistance of the transformer should be checked, Bushings should be cleaned and inspected for any cracks, checking of any loose connections of the terminations of HV & LV side, breather examination. Dehydration of Silica gel if necessary. Explosion-vent diaphragm examination. Conservator to be cleaned from inside. Cleanliness in the Substation yard with all nets, vines, shrubs removed. • DG set: Routine & preventive maintenance of DG sets with AMF panels including maintenance of controlling/protective accessories, battery check. Replace/charge as required. DG set general servicing as per manufacturers recommendation. replacement of filters etc. as required. •HT / LT panels: Check for loose connection of all terminals in the panels, Clean gently the dust by air pressure in side the panels, Check the mounting of CTs for its position, ensure that does not make contact with body, Check for loose connections for all power / neutral cable connections, Check for all the fuses, Check for loose connections of all power cables & control cables of panel, Check for loose connections of cables of meters / contractors, Check the outgoing & incoming phase, neutral connection of circuit breaker, Check the thermal trip of circuit breaker, Check mountings of circuit breaker & tightness of power cables. If anything mentioned above found not normal, same shall be rectified • APFC panel: Cleaning should done by using blower. Microcontroller not working condition to be replaced. Current of each capacitor should be measured and recorded once in month to know healthiness of each capacitor bank. Current should be measured by using clamp tester. If the value of current is less than 50% of the Rated value. Capacitor should be replaced with new one. Connections should be checked for any loose connections. • Routine, preventive maintenance of Lighting & Power Distribution Systems. • Routine, preventive maintenance of HT, LT cables & Wirings. • Earth resistance measurement of all the Earth electrodes • Checking, fitting cleaning and fault rectification of the lighting fixtures
Scope of Work for Conveyors: • Motor - checking of alignment of motors • Bearing at various locations to be checked and oiled / greased wherever necessary • Lubrication to be carried out for all the rollers as necessary to avoid any squeaking noises. • Belt, pulley: : routine & preventive maintenance. • Electrical control panel: routine & preventive maintenance. • Painting of parts wherever necessary to prevent parts from being rusted. Overal the grading sorting machineries are to be cleaned and made ready for use considering that they may be used for export oriented purpose. Parts that are coming in contact with the product during operation should be ensured to be of allowable SS or other food grade material. If any part like motor etc needs replaceent, then the cost of the motor would be borne by the end-user / MSAMB / user but the installation and commissioining of the part shall have to be done as part of this contract and the labour costs and minor accessories for the same to be considered. For this, a site visit for seeing the condition of the equipment is extremely critical.
Scope of Work for split Acs (approx. total 11 nos of capacity 1 TR , 1.5 TR, 1.83 TR): • Condesner cleaning with compressors air, brush etc • Indoor unit filter checking and cleaning • Cleaning of evaporator coils • Checking the motor, blower, drain line, coils, operating pressures and temperatures, the return and supply lines, refrigerant levels, and connection. top up refrigerant if required. • Remote control unit- check if in working conditon. replace the batteries or full unit as may be necessary if found in non working condition.
Racking System
Heavy Duty type industrial racks with 3 (G+2) nos of shelves and total ht of max. 1.2m. Billing will be on total ground area covered. The racks shall be durable, robust in construction and designed to use space in an economical manner.
The scope of work involves Design, Supply and Assembly & Installation of modular type Multilevel car parking type racking system designed for product storage in pallets. The racking system shall be G+1 floor with ground floor pallets stored on floor. The platform for storing pallets on 1st level shall be designed for 1 MT/sqm loading. Maximum lift ht for the platform shall be 2m. The platform floor shall be suitable for hand pallet truck movement and movable ramp to ensure that hand pallet truck loaded with pallet can easily be pushed onto the loading platform with low inline to ensure products to do not fall off while loading/unloading. Designed in modular manner with Upto 8 pallet position (4 on ground + 4 on platform on 1st level) in one bay.Billing will be on per sqm floor area of installation. A steel frame work mounted on the floor consisting of supports, steel pillars with sliding platform supports, cross and longitudinal members etc. This racking system shall have a platform consisting of side members, cross members, platform base sections, adjustable wheel-stops, screws, small parts, etc. Lifting device (1 for each module) for lower floor (pit) platform shall have hydraulic power pack /cylinder/similar pushing mechanism with solenoid valve, sprocket wheels, chains and limit switches and aor similar devices etc as may be required as per standard design. The platforms are suspended on four points respectively and are guided along the supports via sliding bearings. Essential safety features also shall be provided. Control/power panel (1 no for each module) with required power control cabling shall be provide. “EMERGENCY STOP” button shall be provided on control panel. All kinds of electrical works power, control wirng, getting supply to control panel from available power supply point at site shall be included in the scope. There shall be flexibility in the ht of the platform for storage at different heights as required. This entire structure will be mounted on existing tremix flooring and the bidder is advised to visit site before quoting. Structural stability of the racks is the most important criterion and the racks should be designed according to the requirements given. All steel components to be powder coated for obtaining a smooth , scratch resistant and lasting attractive finish .System to ensure quick dismantling, transporting & reinstallation.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .