Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC 2 3 AMIT VIJAY APARTMENT KASTURBA CROSS ROAD KANDIVALI W MUMBAI 67 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹9.3 L+₹52,000 (5.96%)Rejected-AOC B 10 KRISHNA IND ESTATE BIDC GORWA VADODARA 390016 | VADODARA | VADODARA | GUJARAT | 390016 | L2 | Rejected-AOC Being Not Lowest |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
16 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col PS Chand, CWE
Commander Works Engineer, Military Engineer Services, Minniebay, Junglighat Post, Port Blair 744103
80884 Structural Rehabilitation to distressed RCC structure to MD ACCN Bldg No P23 P24 P71 P73 P74 P10 P54 P111 Minniebay Port Blair
2020_MES_353778_1
80884 Structl-Rehabilitation Minniebay Portblair
Open Tender
Civil Works
Item Rate
60 days
Garrison Engineer Minniebay
Class E Category a i
8 documents required · 8 mandatory
₹500
Garrison Engineer Minniebay
₹28,000
Yes
1 Sept 2020
18 Jun 2020
22 Jul 2020
18 Jun 2020
16 Jul 2020
2 Jul 2020
60 days
Amount
Conducting structral rehabilitation for the buildings nos P-23, P-24, P-73, P-74 & P-111 05 buildings of (G+3) Configuration. (APPX plinth area 3216.0Sqm) (a) Mobilization and demobilization of tools /equipment and personal required to execute the job as per specification. (b) VISUAL INSPECTION:- Detailed Physical Inspection Of Structral Members for their condition as to the distress,deterioration, deformation, connections, alteration and various other damages and defects (c ) Conducting Non - Destructive test by rebound hammer as per IS:13311 - Part-II-1992, which rebound numbers converted into compressive strenght. Unit rate consist of average of six readings. (d) Conduct Non - Destructive test of concrete by Ultrasonic Pulse Velocity instruction as per IS 516 (Part 5/ Section-1) : 2018 using 54kHz / 25kHz transducers. Submitting proper analytical report according to codal provision [ Item No.1.00 Contd.../-]
[ Item No.1.00 Contd.../-] (e) Conducting Non - Destructive test by Half Cell Electrical Potential instrument, MECO make as per ASTM C876-91, to assess the durability of reinforced concrete members. Where reinforcement corrosion is suspected and investigating concrete contaminated by chemical attack. Submitting proper analytical and graphical report with contour showing areas prone to corrosion risk according to codal provision. (f) Conducting Non - Destructive test for locating reinforcement bars, cover, approximate bar diameter using profometer (Scanlog) Rebar Detection System, Proceqmake (Switzerland). The instument shall work for such as: (i) locating rebars, (ii) measuring concrete covers & (iii) determining the approximate rebar diameters. (1 No. = 500mm x 500mm grid) (g) Conducting Semi - Destructive test by taking out concrete core through HILTI type (Made in Liechtenstin) coring machine having facility to take core at any required angle. Concrete core extraction of diameter up to 3" including, cutting, finishing, capping and testing for compressive strenght as per IS : 516 & ASTM C 42 : C42M - 99, SP :24.
Conducting structural rehabilitation for the buildings nos P 71, P 10, P 54, 03 buildings of (G+1) Configuration.(APPX plinth area 1858 Sqm) (a) VISUAL INSPECTION:- Detailed Physical Inspection Of Structral Members for their condition as to the distress,deterioration, deformation, connections, alteration and various other damages and defects. (b) Conducting Non - Destructive test by rebound hammer as per IS:13311 - Part-II-1992, which rebound numbers converted into compressive strenght. Unit rate consist of average of six readings. (c ) Conduct Non - Destructive test of concrete by Ultrasonic Pulse Velocity instruction as per IS 516 (Part 5/ Section-1) : 2018 using 54kHz / 25kHz transducers. Submitting proper analytical report according to codal provision. (d) Conducting Non - Destructive test by Half Cell Electrical Potential instrument, MECO make as per ASTM C876-91, to assess the durability of reinforced concrete members. Where reinforcement corrosion is suspected and investigating concrete contaminated by chemical attack. Submitting proper analytical and graphical report with contour showing areas prone to corrosion risk according to codal provision. (e) Conducting Non - Destructive test for locating reinforcement bars, cover, approximate bar diameter using profometer (Scanlog) Rebar Detection System, Proceqmake (Switzerland). The instument shall work for such as: (i) locating rebars, (ii) measuring concrete covers & (iii) determining the approximate rebar diameters. (1 No. = 500mm x 500mm grid). [ Item No.2.00 Contd.../-]
[ Item No.2.00 Contd.../-] (f) Conducting Semi - Destructive test by taking out concrete core through HILTI type (Made in Liechtenstin) coring machine having facility to take core at any required angle. Concrete core extraction of diameter up to 3" including, cutting, finishing, capping and testing for compressive strenght as per IS : 516 & ASTM C 42 : C42M - 99, SP :24.
(a) Based on the interpretation of the NDT test result & semi destructive tests, the concrete actions required alongwith the detailed steps of the methodology of the repairs work to be done including technical and material specification including BOQ shall be suggested. (b) The core cutting area shall be restored using GP2 / any other high strength concrete without any extra cost. (c) Following shall be deemed to be included in the quoted rates for the items:- (i) All the material, labour and equipment required for carry out the tests. (ii) Vetting of structural audit report from NIT / IIT. (iii) The vetting shall be done by the concerned department of NIT/IIT and they shall provide all techinical assistance during the consultancy period.
GEO DESIGNS AND RESEARCH PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .