Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC NULL | L1 | Accepted-AOC Lowest rates | |
| 2 | L2₹29.3 L+₹1.1 L (3.79%)Rejected-AOC | L2 | Rejected-AOC High rates |
| Sl No | Description | Qty | Unit | The Gurukirpa Co-op Society Ltd. L1 | THE SAHOKE COOP LABOUR AND CONSTRUCTION SOCIETY LTD L2 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of
excavation. (6.6) | 159.73 | cum | 203.44 ₹32,495.47 Lowest | 211.14 ₹33,725.39 |
| 2.00 | Cement concrete 1:8:16 with stone aggregate 40 mm gauge mechanically mixed. (Ch. No. 10.6 b ii) | 12.78 | cum | 4,425.34 ₹56,555.85 Lowest | 4,593.01 ₹58,698.67 |
| 3.00 | Cement concrete 1:3:6 with stone aggregate 40 mm gauge mechanically mixed. M-10 | 5.9 | cum | 5,236.87 ₹30,897.53 Lowest | 5,435.29 ₹32,068.21 |
| 4.00 | First class burnt brick work laid in cement sand mortar 1:3 in foundation and plinth | 33.4 | cum | 6,446.69 ₹2,15,319.45 Lowest | 6,690.95 ₹2,23,477.73 |
| 5.00 | First class burnt brick work laid in cement sand mortar 1:3 in first storey upto 4 metres above plinth level | 48.55 | cum | 6,584.17 ₹3,19,661.45 Lowest | 6,833.64 ₹3,31,773.22 |
| 6.00 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. | 45.32 | qtl | 8,402.72 ₹3,80,811.27 Lowest | 8,721.09 ₹3,95,239.8 |
| 7.00 | Supply & Fixing of japani Sheet frames (Chowkats) (Ch. No. 18.51) a Doors and windows frame of size
118mm x 60mm with 40 mm | 67.06 | Running meter | 839.65 ₹56,306.93 Lowest | 871.47 ₹58,440.78 |
| 8.00 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. | 0.67 | qtl | 10,216.36 ₹6,844.96 Lowest | 10,603.44 ₹7,104.3 |
| 9.00 | Centering & shuttering for R.C.C. work in foundation & plinth. (Ch. No. 9.1) | 32.07 | sqm | 234.74 ₹7,528.11 Lowest | 243.63 ₹7,813.21 |
| 10.00 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels.(Ch. No. 9.6) | 84.24 | sqm | 424.75 ₹35,780.94 Lowest | 440.84 ₹37,136.36 |
Tender Value
₹27.0 L
EMD Value
₹54,100
Closing Date
5 Sept 2025, 1:00 pmClosed
Executive Engineer Lehal Canal Division Patiala
Executive Engineer Lehal Canal Division WRD Punjab Patiala
Estimate for reconstruction of zilledari office and JE headquaters office Building at Biroke Rest House
2025_WR_147342_2
47 dated 12.08.2025
Open Tender
Civil Works - Canal
Item Rate
60 days
Mansa
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
₹54,100
Yes
25 Oct 2025
29 Aug 2025
5 Sept 2025
29 Aug 2025
5 Sept 2025
29 Aug 2025
Amount
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation. (6.6)
Cement concrete 1:8:16 with stone aggregate 40 mm gauge mechanically mixed. (Ch. No. 10.6 b ii)
Cement concrete 1:3:6 with stone aggregate 40 mm gauge mechanically mixed. M-10
First class burnt brick work laid in cement sand mortar 1:3 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:3 in first storey upto 4 metres above plinth level
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete.
Supply & Fixing of japani Sheet frames (Chowkats) (Ch. No. 18.51) a Doors and windows frame of size 118mm x 60mm with 40 mm
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
Centering & shuttering for R.C.C. work in foundation & plinth. (Ch. No. 9.1)
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels.(Ch. No. 9.6)
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. (Ch. No. 9.8)
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling. (Ch. No. 14.3)"
Providing and laying vitrified floor tiles of 600mm x 600mm ch 14.113
Terracing consiting of tiles 22.86 x11.43 x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. (Ch. No. 13.13 (i) )
Providing and Fixing 110 mm dia UPVC Rain water pipe of 4 Kgf./sqm etc. Ch. No. 13.74
Providing and Fixing 110 mm dia UPVC bend for Rain water pipe etc. Ch. No. 13.75 a
Providing and Fixing 110 mm dia UPVC Coupling/Sockete for Rain water pipe etc. Ch. No. 13.76 a
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.(Ch. No. 13.55)
Bottom khura on ground 1.2m X 0,6m cosisting of bricks on edge etc.(Ch. No. 13.51)
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.(Ch. No. 13.45)
Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects. (Ch. No. 18.27)
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. 18.25 (b) Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area"
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)(Ch. No. 17.23 ii)
Extra for smooth exposed concrete finish of R.C.C. slab
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish
Distempering with acrylic washable oil bound distempering (16.10)
Finishing walls with acrylic smooth exterior paint of required shade with two coats applied @ 1.67 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm (16.59)
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. (16.15)
Painting two coats including priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade (16.16+16.17) Rs. 28+Rs. Rs. 66 = Rs.
Painting two coats including priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work (16.20+16.17) Rs. 24+Rs. Rs. 66 = Rs. 90/-
12.5 mm thick cement plaster 1:4 (Ch. No. 15.9)
RCC M-25 in sub str complete as per drawing and Technical Specifications using batching plant upto ht 5mtr
Curtain rod 25mm dia aluminum pipe with brackets fixed in position including nails and screws etc.
Providing and fixing steel rings chromeplated 3.80 cm. dia. for curtains. (Market Rate)"
Providing ceiling Fan
Providing LED Tube light of 10W
Providing SOLAR LED EXTERIOR LIGHTS
Providing Office Chair at JE Room zilledar Room and patwari room
Providing Office Table at JE Room,zilledar and patwari room
Providing Office Almira at JE Room,zilledar and patwari room
Providing Air Cooler at JE Room zilledar and patwari room
Deodar wood doors shutter windows shutter including hinges, screw and cords etc. Complete fixed in position
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:- ((i) ) Wiring fan point (Without fan box)
((ii)) Wiring light point
((v)) Wiring 6Amp. Plug control comprising wall socket point
((vi)) Wiring 16/20Amp. power plug control point
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- ((xi)) 6/10amp. One Way Modular Switch (One Module)
((xiii)) 16/20amp. One Way Modular Switch with Indicator (One Module)
((xv)) 6amp. 2/3 Universal Modular Shuttered Socket (two Module)
((xvi)) 16/20amp. Universal Modular Shuttered Socket (two Module)
((xviii)) Step type Modular Electronic Fan Regulator 100watts (One Module)
((xxvii)) Bakelite Batten Holder (Large size)
((xxxii)) Supply and erection of Modular Cover Frame (Complete set) on the existing metal box including fixing and connection of existing switches and sockets and other petty material etc:- ((a)) Modular Cover Frame One or Two Module
((b)) Modular Cover Frame Three Module
((c)) Modular Cover Frame Four Module
((d)) Modular Cover Frame Six Module
((e)) Modular Cover Frame Eight Module
((xxxiv)) Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):- (a) Powder Coated Concealed Metal Box with Brass Lugs One/Two Module
(b) Powder Coated Concealed Metal Box with Brass Lugs Three Module
(c) Powder Coated Concealed Metal Box with Brass Lugs four Module
(d) Powder Coated Concealed Metal Box with Brass Lugs Six Module
e) Powder Coated Concealed Metal Box with Brass Lugs Eight Module
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB‘s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs: ((ii)) MCB Single Pole 6-32amp. (10kA, Curve-C)
((xvi)) MCB Four Pole 50, 63amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB‘s/ RCBO‘s/ RCCB‘s: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO‘s/ RCCB‘s in the distribution board (For SP&N distribution board with provision DP MCB‘s/ RCCB‘s/ RCBO‘s as incomer and SP MCB‘s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB‘s/ RCCB‘s/ RCBO‘s as incomer and SP MCB‘s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- ((xvi)) Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS: 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCBs as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.: ((a)) TP&N Double Door Vertical DBs 4 way each (With provision of FP MCCB upto 125amp)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- ((i)) Heavy Gauge PVC Conduit Pipe 20mm dia. (On Surface)
((ii)) Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- ((i)) Overall size 1sq.mm (Un-sheathed)
((ii)) Overall size 1.5sq.mm (Un-sheathed)
((iii)) Overall size 2.5sq.mm (Un-sheathed)
((iv)) Overall size 4sq.mm (Un-sheathed)
DISMANTLING WIRING POINTS & FITTINGS: Dismantling old wiring points including necessary repairs to wall etc:- ((i)) Fan, light or call bell point
((ii)) Wall socket, power plug point
XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:- ((xxii)) Overall size 25sq.mm (3½ Core) Armoured (Underground)
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. ii)) Size 550 mm x 400 mm x815mm
Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. (i)) Vitreous chinaware standard white pedestal for wash hand basin
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. ( A) Single Socket Type A (b) 110mm o/d single socket SWR UPVC pipe lines laid complete
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. ((a)) Size 75 mm x 75 mm
Providing and fixing in position automatic brass Ball Cock in tanks. (B) Brass Ball Cock with rod and Plastic Ball ((ii)) 20mm i/d
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. ((i)) Triple Layer Tanks
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. (a) CPVC SDR 11 Pipe & fitting 16mm o/d
b) SDR 11 CPVC pipes & fittings 20mm o/d
c) CPVC SDR 11 Pipe & fitting 25mm o/d
Cutting holes upto 23cm square for pipes in flooring and roofs of bricks, tiles with lime concrete or cement concrete and making good the same & finishing according to existing finish where required (b) Through floor or roof 11.5cm thick
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc.and making good to its original condition but excluding cost of lead joining (B) For 110mm o/d pipes (ii) Single Tee With Door
(vi) Vent Cowls
(viii) Coupler
(x) P Trap/Floor Trap 110mm x 75mm
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. (i)) C.P. Brass extension piece, 25mm long to 50mm long
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. ((ii)) C.P. brass Bib cock foam flow without flange
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. ((c)) C.P.brass 15mm Angle valve without flange
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. ((a)) PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut
Providing and fixing in position GI tank nipple of approved make (to the aapproval of EIC) in PVC wtater storage tanks complete in all respects
Foot Rest for Manhole Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturers permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Providing and fixing RCC manhole covers only A) 560mm i/d RCC man hole cover only as per ISI iii) Medium duty
(48 A) Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. (1) With F.P.S. bricks
Cement concrete 1:4:8 with brick balast 40mm gauge (i) mixing by manual means
Cement concrete 1:2:4 With stone ballast or shingle i) mixing by manual means
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc
PLASTERING & POINTING Cement rendering on plaster 1mm thick
PLASTERING & POINTING 12.5 mm thick cement plaster 1:2
Providing and fixing in position H.C.I. soil waste vent or antisyphonage pipes to I.S.I. specification (IS:1729) of approved make (to the approval of Engineer-in-charge ) including cutting, jointing, wastage, but excluding cost of lead jointing.
Providing lead caulked joints to H.C.I. pipes and specials conforming to I.S.I. Specification (IS:1729) of approved make (to the approval of Engineer-in- charge ) including cost of lead yarn, fuel and tools etc.
Providing and fixing in position H.C.I specials for soil waste vent or anti syphonage pipes to I.S.I specifications (IS:1729) of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
SANITARY INSTALLATIONS Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. ((b)) Water Cooler Full Steel Body 60/80 ltr Capacitywithout Stablizer
Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. (a) Boring with 150mm id Housing Pipe (1) Upto 150 m depth BGL
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. a)) 100mm internal dia.
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – in-charge. ((a)) 100 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. ((a)) 100 mm nominal size dia.
Providing and installing submersible motor 1.5 HP along with assembly and electrical connections complete in all respects
THE SAHOKE COOP LABOUR AND CONSTRUCTION SOCIETY LTD (BID ID -679705)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .