| 1 | L1₹16.7 LAccepted-AOC AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.8 L+₹17,475 (1.05%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹17.1 L+₹42,270 (2.54%)Rejected-AOC DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹19.1 L+₹2.4 L (14.5%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹20.4 L+₹3.7 L (22.3%)Rejected-AOC | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
15 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 874 EWS C/O 56 APO
GE 874 EWS C/O 56 APO
WINTER PREPERATION FOR EXTERNAL ELECTRIC SUPPLY FOR THE AREA OF AGE BR I AND AGE BR II UNDER GE 874 EWS
2021_MES_497430_1
GE 874/EWS-61/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kupwara
As per NIT and tender documents
6 documents required · 6 mandatory
₹500
GE 874 EWS
₹50,000
Yes
17 Feb 2022
24 Dec 2021
17 Jan 2022
24 Dec 2021
15 Jan 2022
8 Jan 2022
24 Dec 2021 - 31 Dec 2021
60 days
Amount
E/M Portion
Excavation in trenches n. exc. 1.5m wide and n.exc. 1.5m in depth for foundation laying of pole stay assembly and laying of LT cable in any type of soil and getting out complete all as specified and directed.
All as item No 1 Above but depth beyound the 1.5m for pole.
Returining filling in including spreading, levelling, watering and wall ramming in layers not exc 25cm thick in any type of soil complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified.
Material and labour for kiln burnt Sub class 'B' bricks laid dry, flat, width wise along the length of cable in trenches after sand cushioning for protection of under ground cable complete all as specified and directed.
Supply & Laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old unserviceable damaged cables of 16 Sqmm, 4 core. Make- Finolex/gloster/Havells.
Supply & Laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old unserviceable damaged cables of 35 Sqmm, 3.5 core. Make- Finolex/gloster/Havells.
Supply & Laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old unserviceable damaged cables of 50 Sqmm, 3.5 core. Make- Finolex/gloster/Havells.
Supply & Laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old unserviceable damaged cables of 95 Sqmm, 3.5 core. Make- Finolex/gloster/Havells.
M&L Cable end termination joint outdoor heat shrinkable type suitable for straight through alu conductor , 11KV XLPE of 50 to 95 sqmm x 3.5 core cross sectional area including testing and commissiong etc complete all as specified Make - Raychem/ Denson
M&L Cable end termination joint outdoor heat shrinkable type suitable for end joint alu conductor , 11KV XLPE of 50 to 95 sqmm x 3.5 core cross sectional area including testing and commissiong etc complete all as specified Make - Raychem/ Denson
M&L for GI pipe, light grade 40mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for GI pipe, light grade 50mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
Cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, including taking down unserviceable/old cross arms, complete all as specified and directed.
Supply & fixing LT, PVC line spacer/separator for 2 wire complete all as specified and directed by Engr-in-Charge.
Supply & fixing LT, PVC line spacer/separator for 3 wire complete all as specified and directed by Engr-in-Charge.
Supply & fixing LT, PVC line spacer/separator for 4 wire complete all as specified and directed by Engr-in-Charge.
M & L for pin type, porcelain, vitreous, white or brown insulator including one galvanised mild steel spindle, one galvanised iron washers and one galvanised iron nut, 133mm height, 125mm dia. Including taking down old unserviceable pin insulator complete all as specified.
M & L for shackle type insulator LT of size 90 cm dia and 75 mm high porcelain vitreous white, green or brown for working pressure 1100 volts grade including galvanised mild steel straps, washers, insulator bolts, washers and nuts all as specified and directed by Engineer-in-Charge. Section of straps 31 x 3 mm, dia of bolts 12 mm.Including taking down old unserviceable shackle type insulator complete all as specified.
Supply and fixing in replacement LED street light fitting, of capacity 45 watt with having high pressure die cast aluminium housing with sealed toughened glass cover suitable for pole mounting, protection IP66 including 2.5 sqmm copper cable three core for connection including taking down unserveciable street lights of any type any capacity from pole/ site all as specified and directed. Make Havells, Phillips, wipro.
Supply and fixing in replacement LED street light fitting, of capacity 60 watt with having high pressure die cast aluminium housing with sealed toughened glass cover suitable for pole mounting, protection IP66 including 2.5 sqmm copper cable three core for connection including taking down unserveciable street lights of any type any capacity from pole/ site all as specified and directed. Make Havells, Phillips, wipro.
Supply and replacement of MCCB 63 Amp TPN 415 Volt breaking capcity 16kA. Make Havells Cat part No IHLGHF0063 or Equivelent Make of L & T or C&S.
Supply and replacement of MCCB 100 Amp TPN 415 Volt breaking capcity 16 kA. Make Havells Cat Part No IHLGHF0100 or Equivelent Make of L & Tor C&S
Supply and replacement of MCCB 160 Amp TPN 415 Volt breaking capcity 36 kA. Make Havells Cat Part IHLGHF0160 or Equivelent Make of L & Tor C&S
Supply and replacement of MCCB 200 Amp TPN 415 Volt breaking apcity 35 kA. Make Havells Cat part No IHLFN40200 or Equivelent Make of L & Tor C&S
S & F in replacement steel tubular swaged poles erected truly vertical or planted as strut complete with 300 x300x 6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap, bolts, nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II. type 410 SP-55 (11.0 metres long) including drilling of holes of reqd size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally & portion embedded in concrete, making five black & red bands at lower portion of pole each 300mm wide alternately, and making pole No. with black paint at suitable height all as specified and directed.
Plain Cement concrete in Bed of poles streets and stays 1:4:8 type D-2 using 40 mm graded crushed stone aggregate all as specified directed.
Plain Cement concrete 1:2:4 type C-2 using 40 mm graded crushed stone aggregate as in pole coping and stay assembly all as specified directed.
Plain Cement concrete in foundation of poles streets and stays 1:3:6 type C-2 using 40 mm graded crushed stone aggregate all as specified directed.
M&L in replacement of Stay assembly for electric pole complete with accessories as shown in electrical plate No 1 of SSR Pt-I and drg using loop type insulator, stay clamps, stay rod of 16 mm dia including stay wire of size 7/3.15 mm (excavation and concrete to be measured separately)
Earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore light grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point / Transformer neutral/ Body/ LT panel etc. and testing on completion, complete all as specified & directed.
Restretching of ACSR conductor and GI wire of any size and on any type of poles carrying upto six conductors in a span including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including re-fixing/re-adjusting line spans, line separators, cross arms on poles all as specified.
Cutting /Trimming/ Chopping of tree trenches along the overhead lines upto 3 m from elect lines clearance on both sides of HT/LT lines and disposing off the cut tree/ branches site to a distance not exc. 50 m and clearing the site as directed.
Supply and fixing aluminium thimble of size 70 to 190 Sqmm, all as specified and directed.
Supply and fixing copper thimble of size 25 to 50 Sqmm, all as specified and directed.
Supply only in replacement of off load changover switch 415 volt in sheet metal enclosure 3/4 pole of capacity from 63 Amp to 250 Amp complete all as specified and directed by Engr-in-Charge
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 05 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, all as specified and directed.
POPULARHARDWARESTORE
M/S ASHRAF CONSTRUCTIONS
M/S ABDUL AHAD SHAH
AAKASH CONTRACTORS
M/S S. D. BUILDERS
M/S MIR BUILDERS
M/S ABDUL AZIZ MIR
Bidder Name
M/S ABDUL AHAD SHAH
M/S S. D. BUILDERS
FG CONSTRUCTION
M/S ASHRAF CONSTRUCTIONS
M/S MIR BUILDERS
POPULARHARDWARESTORE
M/S ABDUL AZIZ MIR
AAKASH CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .