Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC HOUSE NO RA 288 GANDHI CHOWK SADAR BAZAR KARNAL HARYANA 132001 | KARNAL | HARYANA | 132001 | ₹1.1 Cr | L1 | Accepted-AOC LOA issued |
Tender Value
₹1.2 Cr
EMD Value
₹2.3 L
Closing Date
23 Dec 2024, 5:00 pmClosed
AMIT GOYAL
ED - Karnal
Providing Lighting System at various Tiraths under Pundri constituency ( Sakra, Chandlana, Barot, Bandrana, Kaul, Bhana, Jadola, Jajanpur, Hajwana, Karora, Mohna, Sangroli, Pharal, Pabnawa, Rasina, Saleempur Mehdood, Habri, Teontha) Recall
2024_HRY_417073_1
2024F949C695 3ECA 4F65 A5B5 D14FF9F81548665BAR
Open Tender
Electrical Works
Works
150 days
RASINA HABRI TEONTHA MOHNA BHANA KARORA BAND
2 documents required · 2 mandatory
₹15,000
₹2.3 L
Yes
22 May 2025
12 Dec 2024
24 Dec 2024
12 Dec 2024
23 Dec 2024
12 Dec 2024
Amount
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA [Through Rate]
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate]
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate]
[23.22.3.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.3. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. TPN enclosure suitable for TP , TPN or FP MCB [Through Rate]
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
[23.22.5.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.7. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs FOUR POLE [Through Rate]
[23.27.3]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate]
[23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
[23.5.6.4]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate]
[23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate]
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
[24.1.14]EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size. [Through Rate]
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
[24.13.14]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 14. 10 Sq mm 2core (Arm.) [Through Rate]
[24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]
[24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate]
[24.13.5]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 5. 4 Sq mm 4 core (UnArm.) [Through Rate]
[24.4.15.2]STREET LIGHT 15.2. B.S.E.N. 10025 High Masts "Supply, installation, testing and commissioning of 16 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip, galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 9/12 nos. luminaire loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 nos. steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete in all respect upto entire satisfaction of Engineer -in-Charge Thickness of Top and Bottom Section = 3 mm & 4mm (minimum) Top Dia = 150 mm and Bottom Dia = 410mm Thickness of Galvanization - Top = 65 micron (minimum) and Bottom = 85 micron (minimum)" [Through Rate]
[24.4.2.2]STREET LIGHT 2.2. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole 90 cm long, with 20 cm high suitable size pole cap [Through Rate]
[24.4.5]STREET LIGHT 5. Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box including painting and necessary connections. [Through Rate]
[24.4.8.4]STREET LIGHT 8.4. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 6 Metre Long pole with top dia 75 mm and bottom dia 150 mm with base plate of size 275 x 275 x 16 mm [Through Rate]
[24.5.1.1]MISCELLANEOUS ITEMS 1.1. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 1.5 sqmm [Through Rate]
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
[24.9.2]RCC FOUNDATIONS FOR HIGH MAST OCTAGONAL POLES 2. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 75 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for high mast octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 16m high mast pole [Through Rate]
[32.70.1]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 1. Above 1 kWp and up to 10 Kwp [Through Rate]
S/E/T/C of 72 Watt LED street light Luminaries with pressure die cast aluminium housing with lens and accessories required to complete the job in all respect including erection on existing pole for fixing including connection of the same up to the entire satisfaction of Engineer-in-Charge of the work (Make as per approved list)
Supply, erection and commissioning of Timelite 63 A. 3 pole / 230V Astronomical time switch Indo Asian make automatic Timer ON/OFF the street light, pillars, wall, MS pedestal where ON/OFF point is available cabinet is fabricated from 22 gauge MS sheet painted, wiring, connection ON/OFF from the bottom of the cabinet the lite DB IP 54 protection complete with Digital timer, 32A. TPN MCB (Indo-Asian), fuse unit, indication lamp suitable for switch from rectifier system, switching system Bakelite connector 32A. Digital timer, auto / manual system, time setter, fiber sheet rubber and plastic components, wiring and component fitting, chemical (Epoxy) including the cost of labour and petty material etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of the work.
S/E/T/C of 150 W LED Flood light Flood Light Luminaire 10 degree Calcius to 50 degree Calcius, operating voltage range-140V - 270V Housed in pressure Die cast Aluminum alloy for housing (Heat-sink) for effective thermal management sturdiness and corrosion resistance IP66 protected covered tempered protective toughened glass, thermal shock and impact resistance, fix to the housing with SS screws having lumen efficacy of LED = 120 lm/W with Colour 5700K, PPC lens for uniformity inbuilt potted LED driver (SMPS based constant current supply) lower THD open circuit protection, over voltage protection, surge protection, and other safety test as per IS:15885 and BIS comply make as per approved list attached complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work.
S/E/T/C of 200W LED Flood light Flood Light Luminaire 10 degree Calcius to 50 degree Calcius, operating voltage range-140V - 270V Housed in pressure Die cast Aluminum alloy for housing (Heat-sink) for effective thermal management sturdiness and corrosion resistance IP66 protected covered tempered protective toughened glass, thermal shock and impact resistance, fix to the housing with SS screws having lumen efficacy of LED = 120 lm/W with Colour 5700K, PPC lens for uniformity inbuilt potted LED driver (SMPS based constant current supply) lower THD open circuit protection, over voltage protection, surge protection, and other safety test as per IS:15885 and BIS comply make as per approved list attached complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work.
S/E/T/C of Decorative 4 mtr height make of Galvanised mild steel tubes having (1000mm x 140mm x 4mm) dia at bottom and (3000mm x 75mm x 3mm) dia at top with cast aluminium of Twinkle make, model Luxmax-pole-140-75 with EMB-Z4 and equivalent make of Mayfair with primer coated and painted with polyurothane paint included service window at the bottom with 25 amp connector terminal and a MCB, with mild steel base plate size 210 mm x 210 mm and 4 no. mounting hole and 16 mm 18` long hot dip galvanised L-shape foundation nuts and bolt in suitable size 300 mm x 300 mm x 1000 mm deep CC foundation of ration 1:2:2 with Single Arm Bracket (BKT-3133-500) and Clipper LED fitting - 40 Watt. to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of the work. (N.S)
Supply and Erection of double arms bracket made of 32mm dia GI pipe B class ISI 0.900 mtr. Long with 25mm dia bottom pipe GI with coller pipe (GI) 90mm dia 20cm Long with MS nipple as required for fixing of fitting duly welded at end of bracket top covered with ornamental cap duly welded, painted 2 coats of aluminium paints on bracket and golden paint of ornamental cap including the cost of labour and petty material etc. complete in all respect upto the entire satisfaction of Engineer-incharge. Bracket duly erected on existing Octagonal pole.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .