Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹24.0 L+₹1.2 L (5.25%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹24.2 L+₹1.4 L (6.20%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹25.9 L+₹3.0 L (13.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
10 Oct 2023, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
SPL REPAIR TO BLDG NO T-10A (COOK HOUSE AND DINING HALL) AT BALNOI, SPL REPAIR TO BLDG NO T-46 AND T-30 AT JWG AND PROVN OF CENTRAL SOLAR HEATING POINT (03 X 300 LPD) AT K NALLAH UNDER GE 881 EWS
2023_MES_618466_1
GE/PNH-43/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹57,000
Yes
6 Jan 2024
12 Sept 2023
17 Oct 2023
12 Sept 2023
10 Oct 2023
26 Sept 2023
Amount
B&R PORTION:- Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc. finished even & fair, complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in flooring by maintaining requires gradient/undulation, finished even & fair without using extra cement, complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, including filled the joints with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.11Sqm but n exc. 0.18Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.18 Sqm but n exc. 0.38Sqm in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.18 Sqm but n exc. 0.38Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed.
M&L for glazed ceramic coloured tiles (450x300mm) x 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick back coat layer in cement mortar 1:4, complete all as specified and directed by Engr-In-Charge.
Demolition of cement concrete (reinforced) in any description, complete all as specified and directed.
M&L for chequered cement concrete tiles 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed with grey cement mixed with pigments, laid over and including 15mm thick screed bed in CM 1:6, complete all as specified and directed.
Demolition of stone slab laid bedded and pointed in any mortar of any description or any thickness in floors, aprons etc complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 20-25mm thick , bedded and jointed with grey cement slurry and pointed with grey cement with admixture or pigment to match the shade of Kota stone slab as approved by GE, laid over and including screed bed or bedding layer of mortar 20mm thick in Cement Mortar (1:6) including cutting, grinding and mirror polishing, complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for rendering 15mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 with mixing of liquid water proofing admixture @ 200 ml/50kg of cement and finished the surface even and smooth without using extra cement, complete all as specified and directed. Note: WPC shall be measured and paid separately
M&L for 15mm thick rendering in CM 1:6 on other than fair faces of brick or stone masonry wall surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces, chajja and suspended work & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 10mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces, chajja and suspended work & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
S&F box type steel window glazed and gauged (combination) with side hung/ top hung shutter including box type/ projecting type hinges and steel peg stay, handle and locking arrangement (02 Nos MS tower bolts 150 mm long for each leaf) and frame made out of 1.25mm thick pressed steel frame complete including necessary cooler arrangement in window and guard bars including one coat of red oxide zinc primer and all as per sample kept at GE office and complete all as specified and directed by Engg-in-charge.
Supply only liquid water proofing admixture complete all as specified and directed.
M&L for preparation of newly plastered / unplastered surfaces of wall including cornices pilaster etc, and applying two coats of cement base paint over a coat of white wash complete all as specified and directed.
M&L for preparation of new plastered / unplastered surface of wall including cornices pilaster etc, and applying two coats of oil bound distemper over and including 1 mm thick wall care putty, complete all as specified and directed.
M&L for complete removal of existing treatement from wall plaster and applying two coats of oil bound distemper white or any tint, over and including 1 mm thick wall care putty, complete all as specified and directed.
S&F in repair 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and directed.
M&L for preparation of old plastered/ un-plastered wall surfaces including brooming down or steel wire brushing, scraping down, smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots, and applying one coat of cement base paint, complete all as specified and directed.
M&L for complete removal of existing treatement from wall plaster and applying two coats of cement base paint, complete all as specified and directed.
S&F Steel windows or ventilators comprising of tubular frame and shutter made out of 1.25mm thick pressed steel frame with glazed & gauged shutters (combination), side hung / top hung type with or without glazing bars as directed including box type / projecting type hinges and steel peg stay, handle, MS tower bolts 150mm long for each leaf and 8 mm square grill/guard bars at spacing as directed and welded to MS flat iron frame work, PCC blocks for hold fast etc complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm and not exceeding 4 Sqm each, complete all as specified and directed.
S&F factory made pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc. with one shop coat of primer complete all as specified and directed.
S&F 35mm thick 2nd class hard wood plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and directed.
S&F 35mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of pink primer, complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beading, complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area not exceeding 1.5 Sqm , complete all as specified and directed.
Dismantling timber in scantling 40 sqcm and over in section unframed work, complete all as specified and directed.
Dismantling of timber scantling under 40sqcm in section unframed work as in fillets, rails, posts, rafters, purlins etc, complete all as specified and directed.
S&F Sheet glass ordinary quality, 4mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and directed.
Dismantling framed trusses span not exc 10 mtr complete all as specified and directed,
S&F aluminium anodised, barrel tower bolts of extruded section of size 150mm complete all as specified and directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section of cast aluminium alloy complete all as specified and directed.
S&F aluminium alloy handles, cast type, anodised of size 150mm and fixed, complete all as specified and directed.
Taking up or down steel tubing of 15 mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed.
M & L for plain cement concrete 1:2:4 type B-2, using 40mm graded crushed stone aggregates as in surfaces channels and drain complete all as specified and directed.
S&F GI tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and directed.
Taking up or down steel tubing of 20 mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed.
S&F GI tubing of 20 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and directed.
S&F in repair 20mm bore gun metal globe or gate valve (ISI marked) with iron wheel head,screwed both ends for iron pipe complete all as specified and directed.
S&F in repair bib tap 15 mm bore with flange, Brass CP, with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule complete all as specified and directed.
M&L for Vitrified coloured tiles 10 mm thick, premium quality (square/rectangular) area of each tile not exc 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM (1:6), complete all as specified and as directed.
All as per Item No 50 above but as in skirting/dados including 10mm thick screed bed in CM (1:4), complete all as specified and as directed.
S&F rotational moulded polyethylene water storage tanks triple layer (Cylindrical vertical with closed top) hoisted and fixed in position all as spd in SSR Pt-I, of capacity 1000 Ltrs incl with 20mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule, including dismantling existing water tank and removing from site complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for walling of random rubble stone/boulder masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
All as per item No. 54 above, but except stone complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 20mm to face stones (lime and sand stone) and dressing of face beds and joints, complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed.
M&L for cement concrete (1:2:4) type-B-1 (using 20mm graded stone crushed aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C1 using 20m graded crushed stone aggregate as in bed block or for embedding of holdfasts, complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) any thickness including cover fillets complete all as specified and directed.
S&F anodised aluminium snap grid frame work for false ceiling of size 605 x 605mm complete all as specified and directed.
S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L for 4mm thick non asbestos fibre cement building fixed or laid/inserted to timber/GI/aluminium framework fixed in ceiling with screws complete all as specified and directed.
Dismantling plain or corrugated steel sheeting/AC sheets, any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter and similar works fixed with self tapping screws complete all as specified.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
M&L for rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410 W(Gde E 250), quality B complete, complete all as specified and directed.
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connected plate confirming to Fe 410W(Gde E-250), quality 'A' complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
S&F 4 mm thick E-board (Classic) including fixing of frame work made up of special MS section, galvanized sheet with zinc coating cellular intro painting and consisting of angle cleats of size 25 mm wide, 1.6 mm thick with flag fixing to the ceiling with dash fastener 12.5 mm x 40 mm long or with 2 mm dia GI wire or fixed with bolts in GI channel main of size 35x25x0.5 mm thick and cross runner of size 25x25x0.5mm for fixing E-board of size 600x600mm x4 mm thick including fixing of E-board with ceiling section and perimeter of channel 25x25x1mm thick, 27mm high flange of 20mm to 30mm long extra including application of two coats of oil emulsion distemper, complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for TMT bars 6mm to 8 mm dia and cut to length bent to shape and binding with MS wire (annealed) not less than 0.9mm Dia complete all as specified and directed.
S&F in repair 25 mm dia stainless steel curtain rod (16 gauge) complete all as specified and directed.
S&F in repair fancy type decorative brackets for curtain rod complete all as specified and directed.
Formwork to sides and floor or roof beams, beam haunching girders bressummers, lintels cantilevers incl supports, overhangs, etc also splays between floors and beams, etc complete all as specified and directed.
E&M PORTION: Supply, installation, testing and commissioning of "Solar Hot Water System" (Flat plate collector) based on indirect transfer of heat of capacity 300 LPD with electrical back up 0f 4 KW complele all as specified and directed.
S&F rotational moulded polyethylene water storage tanks triple layer (Cylindrical vertical with closed top) hoisted and fixed in position all as spd in SSR Pt-I, of capacity 1000 Ltrs incl with 20mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule, complete all as specified and directed.
Supply, laying and jointing hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore with all fittings complele all as specified and directed.
S&F Stop / Angle cock (ISI Marked), cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore, complete all as specified and directed. Make-Jaquar Cat Part No:-CON-059KN or Equaivalent cat part of make as specified in P.S.
S&F bib tap 15 mm bore with flange, Brass CP, with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule complete all as specified and directed.
M&L for fabrication of stand for mounting cold water storage tank of capacity 1000 ltr, vertical type, using joist, channel, equal angle iron or tee sections fixed independently (Fe-410 W Gde E-250 quality A) without connecting plates including necessary welding, bending etc and painting with two coat of black colour enamelled paint over a coat of red oxide primer complete all as specified and directed.
Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
All as per srl item No 84 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC/poly carbonate, insulated body, complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair switch piano flush type 16 Amp one way, (ISI marked), complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 3 pin, 6 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 5 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 5 and 15 Amp flush type universal, complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed.
Supply and fixing in repair inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Havells cat part No. LHEXACP7FN1W020 or equivalent make as specified in PS
S & F in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing in repair LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver including suitable bracket fixed to wall/ pole complete with IP 65/66 protection complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 12 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store, complete all as specified and directed.
M&L for hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
S&F in replacement dome type angle holder made out of poly carbonate with metal lamp holder ISI marked with back plate fixed on PVC square block with 9 watt LED complete all as specified and directed.
S&F Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat of circular of size 16 Sqmm 2 core including taking down existing old service connection, complete all as specified and directed.
Supply, laying , jointing and testing in repair of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 16 sqmm 2 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed. Make: Finolex / KEI Industries Pvt Ltd / Polycab / Gloster / Universal Cables. Note: Excavation, earthwork, sand cushioning, brick protection shall be measured & paid for separately.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in any type of soil complete all as specified and directed.
Returning, filling in surplus spoil including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning to under ground cable providing with a layer of Sand 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : Punning thickness of 18 cm will be measured for payment purpose)
M&L for Burnt bricks locally available, sub class 'B', laid flat for protection of under ground cable complete all as specified and directed at site.
S&F in repair Tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete of size 40 mm bore, complete all as specified and directed.
Modh Hafiz Khan
narayan construction
VIKAS ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .