| 1 | L1₹33.9 LAccepted-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC Being Lowest bidder | |
| 2 | L2₹35.4 L+₹1.1 L (3.31%)Rejected-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L2 | Rejected-Finance Being other than lowest bidder | |
| 3 | L3₹38.9 L+₹4.7 L (13.6%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest bidder | |
| 4 | L4₹42.7 L+₹8.4 L (24.7%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L4 | Rejected-Finance Being other than lowest bidder | |
| 5 | L5₹42.8 L+₹8.6 L (25.1%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest bidder |
| Sl No | Description | Qty | Unit | MS ENTERPRISES L3 | L and S ENTERPRISES L1 | omsai thermax engineers L2 | Srinivasa Consructions L6 | POWER CONSTRUCTION COMPANY L5 | MONA GENERATOR SEVICES PVT. LTD. L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S & F panel and its connections and supply and install, testing and commissioning of LT feeder panel, factory made cubicle type of suitable and 3.15 mm thick CRCA sheet outdoor type vermin proof with Aluminium bus bar of suitable size, Al strip 3 phase and neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories are fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/ exit boxes for all incoming and outgoing cables with suitable cable glands incl PCC foundation etc complete testing and commissioning complete and consisting the following | 1 | Each | 1,81,693 ₹1,81,693 | 1,80,000 ₹1,80,000 | 1,62,000 ₹1,62,000 | 1,25,000 ₹1,25,000 Lowest | 1,53,000 ₹1,53,000 | 1,51,849 ₹1,51,849 |
| 1.01(a) MCCB 4 Pole 400 Amps 36 KA -01 No. Microprocessor release (Incoming) (b) MCCB 4 Pole 250 Amps 25 KA -01 No. Thermal magnetic release (Outgoing) (c) MCCB 4 Pole 63 Amps 16 KA -05 Nos. thermal magnetic release (Outgoing) (d) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/ 5A LT-CT operated complete - 01 Set (e) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/ walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces. | |||||||||
| 2.00 | S & F panel and its connections and supply and install, testing and commissioning of LT feeder panel, factory made cubicle type of suitable and 3.15 mm thick CRCA sheet outdoor type vermin proof with Aluminium bus bar of suitable size, Al strip 3 phase and neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories are fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/ exit boxes for all incoming and out going cables with suitable cable glands incl PCC foundation etc complete testing and commissioning complete and consisting the following | 1 | Each | 1,28,693 ₹1,28,693 | 1,44,000 ₹1,44,000 | 1,17,000 ₹1,17,000 | 90,000 ₹90,000 Lowest | 1,44,000 ₹1,44,000 | 1,17,967 ₹1,17,967 |
| 2.01(a) MCCB 4 Pole 160 Amps 36 KA -01 No. Microprocessor release (Incoming) (b) MCCB 4 Pole 100 Amps 16 KA -02 Nos. Thermal magnetic release (Outgoing) (c) MCCB 4 Pole 63 Amps 16 KA -01 No. thermal magnetic release (Outgoing) (d) MCCB 4 Pole 32 Amps 16 KA -02 Nos Thermal magnetic release (Outgoing) (e) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 200/ 5A LT-CT operated complete - 01 Set (f) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a)All existing incoming and outgoing cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item. (b) The cost shall also be include the breaking of floors/ walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces. | |||||||||
| 3.00 | Supply, Installation, test and Commissioning factory fabricated, outdoor type, LT FEEDER PILLAR BOX Double Door, Both side openable made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof, Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :– | 6 | Each | 36,693 ₹2,20,158 | 27,000 ₹1,62,000 | 30,600 ₹1,83,600 | 25,000 ₹1,50,000 Lowest | 32,000 ₹1,92,000 | 32,788 ₹1,96,728 |
| 3.01(a) Aluminium bas bar 150 amps - 01 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 100 amps,415 volt,25 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 No | |||||||||
| 4.00 | Supply, Installation, test and Commissioning factory fabricated, out door type,LT FEEDER PILLAR BOX Double Door, Both side openable made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof, Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :– | 5 | Each | 35,993 ₹1,79,965 | 25,200 ₹1,26,000 | 29,700 ₹1,48,500 | 24,000 ₹1,20,000 Lowest | 30,000 ₹1,50,000 | 30,578 ₹1,52,890 |
| 4.01(a) Aluminium bas bar 100 amps - 01 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 63 amps,415 volt,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As INCOMING - 01 No | |||||||||
| 5.00 | Supply and lay in trenches/ fixed to walls/ poles etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 4 Core 16 Sqmm incl taking out of existing cable all as directed. | 1,200 | RM | 183 ₹2,19,600 | 171 ₹2,05,200 | 108 ₹1,29,600 Lowest | 257 ₹3,08,400 | 210 ₹2,52,000 | 224 ₹2,68,800 |
| 5.01 | All as per item no 5.00 above but 4 Core 25 Sqmm | 1,300 | RM | 263 ₹3,41,900 | 234 ₹3,04,200 | 162 ₹2,10,600 Lowest | 322 ₹4,18,600 | 269 ₹3,49,700 | 294 ₹3,82,200 |
Tender Value
₹43.0 L
EMD Value
₹85,940
Closing Date
19 Jan 2026, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
SPECIAL REPAIR TO CONVERSION OF LT OH LINE TO LT UG CABLE AT OML (MILKHA SINGH ENCLAVE) AND JCOS CLUB AT MCEME AND PROVISION OF 40KVA UPS AND CONNECTED ITEMS IN THE LONGTERM RICU OF MH SECUNDERABAD UNDER AGE EM II OF GE (U) SECUNDERABAD
2025_MES_746492_1
GE (U)/SEC/TOKEN/65 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹85,940
Yes
16 Mar 2026
29 Dec 2025
27 Jan 2026
29 Dec 2025
19 Jan 2026
12 Jan 2026
(a) MCCB 4 Pole 400 Amps 36 KA -01 No. Microprocessor release (Incoming) (b) MCCB 4 Pole 250 Amps 25 KA -01 No. Thermal magnetic release (Outgoing) (c) MCCB 4 Pole 63 Amps 16 KA -05 Nos. thermal magnetic release (Outgoing) (d) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/ 5A LT-CT operated complete - 01 Set (e) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/ walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces.
(a) MCCB 4 Pole 160 Amps 36 KA -01 No. Microprocessor release (Incoming) (b) MCCB 4 Pole 100 Amps 16 KA -02 Nos. Thermal magnetic release (Outgoing) (c) MCCB 4 Pole 63 Amps 16 KA -01 No. thermal magnetic release (Outgoing) (d) MCCB 4 Pole 32 Amps 16 KA -02 Nos Thermal magnetic release (Outgoing) (e) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 200/ 5A LT-CT operated complete - 01 Set (f) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a)All existing incoming and outgoing cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item. (b) The cost shall also be include the breaking of floors/ walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces.
Supply, Installation, test and Commissioning factory fabricated, outdoor type, LT FEEDER PILLAR BOX Double Door, Both side openable made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof, Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 150 amps - 01 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 100 amps,415 volt,25 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 No
Supply, Installation, test and Commissioning factory fabricated, out door type,LT FEEDER PILLAR BOX Double Door, Both side openable made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof, Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 100 amps - 01 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 63 amps,415 volt,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As INCOMING - 01 No
Supply and lay in trenches/ fixed to walls/ poles etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 4 Core 16 Sqmm incl taking out of existing cable all as directed.
All as per item no 5.00 above but 4 Core 25 Sqmm
All as per item no 5.00 above but 3.5 Core 35 Sqmm
All as per item no 5.00 above but 3.5 Core 50 Sqmm
All as per item no 5.00 above but 3.5 Core 70 Sqmm
All as per item no 5.00 above but 3.5 Core 95 Sqmm
M&L in replacement of earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron earth strip 32 mm x 6 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, (in any type of strata) charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. Note:- (i) GI strip 32x6 mm and GI pipe 40mm dia light grade up to 7.5 mtr length shall be deemed to include in this items rate. (ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contractor.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/ Steel pole, laying of cable in trenches etc and getting out in Hard / Dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Spreading riddled earth (after preparation of excavated earth) in Cable duct with sand cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge Note:- Punned thickness 18 CM (6.25 Cm below cable and 11.75 cm above cable) will be measured for payment purpose. Quoted rate inclusive of all arrangement as mentioned.
Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
S & F in replacement of Pole mounted junction box of size 200 x 140 x 95 mm outdoor type fixed with Aluminium Strip of Size 20 x 3mm - 2 No and 6 amp MCB SP complete incl fixing arrangements with suitable size clamps, nut & bolts for fixing on pole all as specified and directed. Make Syntex Catpart No GS-JB-2014 and equivalent make of Hensel
Supply and fixing in replacement off multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 1.5 Sqmm, 3 core from pole junction box/ nearest point of connection to street light inside/ outside pole complete all as specified.
Supply and laying GI tubing light grade of size 40 mm for cable protection on road/ drain/ floor/ pole including necessary clamps 40x4 all as specified and directed.
Supply and laying GI tubing light grade of size 50 mm for cable protection on road/ drain/ floor/ pole including necessary clamps all as specified and directed.
Supply and laying GI tubing light grade of size 80 mm for cable protection on road/ drain/ floor/ pole including necessary clamps all as specified and directed.
Cutting the existing road/ PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil up to 75% road portion and 25% shall be made with cement concrete 1:2:4 using 20 mm graded aggregate stone complete all as specified and directed.
Dismantling cross arms of M.S. channel or angle sections etc. complete and setting aside for reuse with in 50m all as specified and directed.
Dismantling insulators any type, any size all as specified and directed.
Dismantling stay assembly complete. (demolition of concrete, etc. and excavation measured separately)
Dismantling of ACSR or AAC conductors all as specified and directed.
Supply, installation, testing, and commissioning of a 40 KVA, 480VDC online UPS system designed for three-phase input and three-phase output configuration including with isolation transformer. The system shall have a minimum overall efficiency of 96% and a power factor not less than 0.9. It shall employ advanced IGBT-based inverter and rectifier technology or better version to ensure high reliability, superior voltage regulation, and low harmonic distortion. The UPS shall provide clean and uninterrupted power to critical loads, incorporating comprehensive protection features against overload, short-circuit, input/output voltage fluctuations, and battery faults. It shall include digital or microprocessor-based control with user-friendly monitoring and display arrangements for key parameters such as input/output voltage, current, frequency, load percentage, and battery status. The UPS system shall be supported by a dedicated battery bank consisting of 40 No’s 12V, 65Ah sealed maintenance-free (SMF) batteries, arranged in appropriate to achieve the required 480VDC configuration. The battery bank shall be capable of providing a minimum backup of 30 minutes at full rated load. All batteries shall be supplied with manufacturer’s test certificates and shall conform to relevant IS/IEC standards. The battery bank shall be installed on a sturdy, powder-coated, corrosion-resistant rack, designed to accommodate all batteries with adequate spacing for ventilation, safety, and maintenance access. Suitable interconnecting copper cables with proper insulation and crimped terminations shall be provided for series and parallel connections. The scope also includes battery circuit breaker, proper earthing arrangements, and all accessories required for safe and reliable operation. (Contd...)
The complete system including UPS, battery bank, battery racks, interconnecting cables, breakers, and accessories shall be supplied, installed, tested, and commissioned at site, inclusive of all transportation, handling, and associated installation charges, to deliver a fully functional and compliant system. Warranty: The contractor shall submit written warranty for UPS system shall be covered under a comprehensive on-site warranty for a period of 1 (one) year from the date of commissioning and for SMF batteries shall carry a warranty of 2 (two) years from the date of supply or commissioning.
M&L of earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron earth strip 32 mm x 6 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, (in any type of strata) charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. Note:- (i) GI strip 32x6 mm and GI pipe 40mm dia light grade up to 7.5 mtr length shall be deemed to include in this items rate. (ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contractor.
Supply and fixing of 65 mm dia HDPE pipes, PN-10 grade, complete with clamps/supports and all fixing accessories, for cable routing and protection, including proper alignment, connection, testing, and commissioning, complete as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
TENDER.pdf
Tender Documents • 0.81 MB
BOQ_835890.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .