Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC NEAR SHIV MANDIR VILLAGE RAJPURA KHARKARI TEHSIL AND DISTRICT BHIWANI 127031 | BHIWANI | HARYANA | 127031 | ₹2.4 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹2.6 CrRejected-Finance | ₹2.6 Cr | L2 | Rejected-Finance Rejected |
| 3 | L3₹2.7 CrRejected-Finance 858 SECTOR 23 127021 | BHIWANI | HARYANA | 127021 | ₹2.7 Cr | L3 | Rejected-Finance Rejected |
| 4 | L4₹2.8 CrRejected-Finance VPO BERLA TEHSIL AND DISTT CHARKHI DADRI HARYANA | CHARKI DADRI | HARYANA | 127022 | ₹2.8 Cr | L4 | Rejected-Finance Rejected |
| 5 | L5₹2.8 CrRejected-Finance | ₹2.8 Cr | L5 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | M/S SHREE BALAJI BUILDERS L3 | OM PARKASH CONT L4 | Sant Lal Contractor L2 | DHARAMBIR GROVER CONTRACTOR L5 | Ravinder Sharma Contractor L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00N.S. Item | ||||||||
| 1.01 | Design, Supply and erection of transformer of standard make Required 25 KVA 11/0.433 KVA rating outdoor type 11 KVA V.C.B, panel, G.O. switch, H. Pole , H.T metering panel, APFC panel, battery charges, 11 KVA substation, entire cable network from G.O. switch to H.T metering equipment and from H.T metering to Transformer. From transformer to main to L.T, panel earthling, safety equipment, fenced enclosure for transformer, and any other contingent thereto complete in all respect as per approved make and directions of Engineer-in-charge as per respective capacity. (500 KVA) | 1 | Each | 9,80,000 ₹9.8 L | 10,00,000 ₹10 L | 6,00,000 ₹6 L | 9,77,777 ₹9.8 L | 7,00,000 ₹7 L |
| 2.00 | Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge.
The rating should be at 1500 RPM.
a) Diesel Engine, b) Alternator, c) Battery 24 v.
d) Base Plate., e) suitable sq mm suitable core copper cable upto 40 metres., f) Tools, standard panel
g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT`s)
h) Metering set 60/5A/11 OV (Amp. Meter, Volt Meter)
i) Overload protection for DC-1 No., j) Battery Charger 24V DC
k)Copper bus bar of suitable size, I) KWH meter 96 sqmm size
m) Starting fuse button and key switch9on/off)
n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set
running, load on, De control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge (400 KVA) | 1 | Nos. | 43,00,000 ₹43 L | 43,00,000 ₹43 L | 35,00,000 ₹35 L | 39,77,777 ₹39.8 L | 34,00,000 ₹34 L |
Tender Value
₹3.0 Cr
EMD Value
₹5.9 L
Closing Date
2 Apr 2026, 3:00 pmClosed
VIJAY Kumar
Mandi Dabwali PHED
Repair of existing S/S tank at Old and 2nd water works, P/F of 400 KVA DG and 500 KVA Transformer at 2nd water works and all other works contingent thereto.
2026_HRY_507834_1
2026BDB97352 C158 4CA6 AEDA B3D768B6CECF586PUH
Open Tender
Civil Works
365 days
Mandi Dabwali
2 documents required · 2 mandatory
₹15,000
₹5.9 L
Yes
15 Jun 2026
12 Mar 2026
2 Apr 2026
12 Mar 2026
2 Apr 2026
12 Mar 2026
N.S. Item
Design, Supply and erection of transformer of standard make Required 25 KVA 11/0.433 KVA rating outdoor type 11 KVA V.C.B, panel, G.O. switch, H. Pole , H.T metering panel, APFC panel, battery charges, 11 KVA substation, entire cable network from G.O. switch to H.T metering equipment and from H.T metering to Transformer. From transformer to main to L.T, panel earthling, safety equipment, fenced enclosure for transformer, and any other contingent thereto complete in all respect as per approved make and directions of Engineer-in-charge as per respective capacity. (500 KVA)
Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Diesel Engine, b) Alternator, c) Battery 24 v. d) Base Plate., e) suitable sq mm suitable core copper cable upto 40 metres., f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT`s) h) Metering set 60/5A/11 OV (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No., j) Battery Charger 24V DC k)Copper bus bar of suitable size, I) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, De control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge (400 KVA)
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Item Description
HSR Item
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.15 MB
BOQ_586602.xls
BOQ • 0.27 MB
777955Z152036.pdf
Additional Documents • 1.91 MB
Download all tender documents and submit your bid