Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAdmitted-Finance 171 CHIKLOD ROAD JAHANGIRABAD BHOPAL MP 462008 | BHOPAL | BHOPAL | MADHYA PRADESH | 462008 | L1 | Admitted-Finance | |
| 2 | L2₹19.5 L+₹3.0 L (18.0%)Admitted-Finance 221 BISARIYA COMPLEX ZONE II M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical FIRST FLOOR 1115 SECTOR 17B 1115 FIRST FLOOR SECTOR 17B GURUGRAM GURGAON HARYANA HARYANA GURGAON HARYANA 122002 | GURUGRAM | HARYANA | 122002 | - | Rejected-Technical The agency has submitted an electrical license issued by the Government of NCT Delhi, which is not in accordance with the NIT criteria. |
| Sl No | Description | Qty | Unit | COOL TECH ENTERPRISES L1 | Weartech Engineers Pvt Ltd L2 |
|---|---|---|---|---|---|
| 1.00Ductable AC :- Supply installation testing and commissioning of, air cooled ductable air conditioning unit of following capacity with scroll compressor of approved make suitable for operation on 3 phase 415 V, 50 Hz AC supply. Comprising of copper condenser, and aluminum fins, and first charge refrigerant including electrical panel. The indoor comprising of fan, fan motor, copper tube, aluminum finned cooling coil, drain pan, filter, controls, safety with ecofriendly gas R410/R410A excluding connection copper pipe of required size, insulation, stand for outdoor unit, connection copper lead wire, condensed water outlet pipe complete etc as required. Outdoor/indoor units should be of same make (brand) complate as required. | |||||
| 1.10 | 8.75 - 8.5 TR three phase | 3 | No. | 1,99,000 ₹5,97,000 | 1,95,000 ₹5,85,000 Lowest |
| 2.00Ducting:- Supply and fixing of site fabricated GI sheet metal ducts in accordance with the approved shop drawings and as required as per specifications. GI sheet will be as per IS-277. All necessary GI /MS supports using thread rods (as directed). Angle, flat, and anchor bolts, food grade neoprene gaskets, food grade adhesive included in the scope. | |||||
| 2.10 | 20G | 70 | sq.m | 1,500 ₹1,05,000 Lowest | 1,600 ₹1,12,000 |
| 3.00Thermal insulation :- Supplying and fixing of following thickness of mat finish closed cell nitrile rubber (class “1”) insulation on existing duct after applying two coats of cold setting adhesive complete as per specifications and as required | |||||
| 3.10 | 19 mm thick | 75 | sq.m | 950 ₹71,250 | 550 ₹41,250 Lowest |
| 4.00Internal duct acoustic insulation: - Supply, installation, testing and commissioning of internal duct acoustic insulation with open cell structured class "O" fire retardant nitrile rubber with density 140 - 180 kg/m³ and specs as per RISAC chart specification sheet inside of the AHU supply air ducting up to 4 mtr. length from AHU mouth as per the specifications, it should have antimicrobial properties | |||||
| 4.10 | 10 mm thick | 75 | sq.m | 500 ₹37,500 Lowest | 900 ₹67,500 |
| 5.00Grills and diffusers cost | |||||
| 5.10 | Supplying & fixing of powder coated extruded
aluminum square diffuser without volume control
damper complete as required. | 5 | sq.m | 9,500 ₹47,500 | 9,000 ₹45,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹39,000
Closing Date
18 Jun 2026, 3:00 pmClosed
Superintending Engineer, AIIMS Bhopal
Office of the Superintending Engineer, 4th Floor, Kautilya Bhawan, AIIMS, Saket Nagar, Bhopal, 462020.
Supply, installation, testing and commissioning of Air Conditioning of HVAC, Electrical and sound system (with speaker control) of Palliative care at 3rd floor of Hospital Building in AIIMS Bhopal.
2026_IMSBP_910429_1
10/NIT/SE/E/ABEU/ AIIMS/BPL/2025-26/Retender1
Open Tender
Electrical Works
Item Rate
60 days
AIIMS
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹39,000
Office of the Superintending Engineer,AIIMS Bhopal
1 Oct 2026
27 May 2026
19 Jun 2026
27 May 2026
18 Jun 2026
8 Jun 2026
2 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Ductable AC :- Supply installation testing and commissioning of, air cooled ductable air conditioning unit of following capacity with scroll compressor of approved make suitable for operation on 3 phase 415 V, 50 Hz AC supply. Comprising of copper condenser, and aluminum fins, and first charge refrigerant including electrical panel. The indoor comprising of fan, fan motor, copper tube, aluminum finned cooling coil, drain pan, filter, controls, safety with ecofriendly gas R410/R410A excluding connection copper pipe of required size, insulation, stand for outdoor unit, connection copper lead wire, condensed water outlet pipe complete etc as required. Outdoor/indoor units should be of same make (brand) complate as required. | |||||
| 1.1 | 8.75 - 8.5 TR three phase | 3 | No. | 1.25 | ₹3.75 |
| 2Ducting:- Supply and fixing of site fabricated GI sheet metal ducts in accordance with the approved shop drawings and as required as per specifications. GI sheet will be as per IS-277. All necessary GI /MS supports using thread rods (as directed). Angle, flat, and anchor bolts, food grade neoprene gaskets, food grade adhesive included in the scope. | |||||
| 2.1 | 20G | 70 | sq.m | 100 | ₹7,000 |
| 3Thermal insulation :- Supplying and fixing of following thickness of mat finish closed cell nitrile rubber (class “1”) insulation on existing duct after applying two coats of cold setting adhesive complete as per specifications and as required | |||||
| 3.1 | 19 mm thick | 75 | sq.m | 10 | ₹750 |
| 4Internal duct acoustic insulation: - Supply, installation, testing and commissioning of internal duct acoustic insulation with open cell structured class "O" fire retardant nitrile rubber with density 140 - 180 kg/m³ and specs as per RISAC chart specification sheet inside of the AHU supply air ducting up to 4 mtr. length from AHU mouth as per the specifications, it should have antimicrobial properties | |||||
| 4.1 | 10 mm thick | 75 | sq.m | 10 | ₹750 |
| 5Grills and diffusers cost | |||||
| 5.1 | Supplying & fixing of powder coated extruded
aluminum square diffuser without volume control
damper complete as required. | 5 | sq.m | 100 | ₹500 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
BOQ_956850.xls
BOQ • 0.42 MB
finalpallativecare.pdf
Tender Documents • 6.98 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .